Your browser doesn't support javascript.
loading
Incremental shuttle walk test: is it able to detect exercise-induced bronchospasm in young adult asthmatics?
Labadessa, Ivana Gonçalves; Garcia-Araujo, Adriana Sanches; Arcuri, Juliano Ferreira; Rizzatti, Fabiola Paula Galhardo; Borghi-Silva, Audrey; Pires Di Lorenzo, Valéria A.
Afiliação
  • Labadessa IG; Physiotherapy Department, Federal University of São Carlos - UFSCar, São Carlos, Brazil.
  • Garcia-Araujo AS; Physiotherapy Department, Federal University of São Carlos - UFSCar, São Carlos, Brazil.
  • Arcuri JF; Physiotherapy Department, Federal University of São Carlos - UFSCar, São Carlos, Brazil.
  • Rizzatti FPG; Paulista School of Medicine, Federal University of São Paulo, São Paulo, Brazil.
  • Borghi-Silva A; Physiotherapy Department, Federal University of São Carlos - UFSCar, São Carlos, Brazil.
  • Pires Di Lorenzo VA; Physiotherapy Department, Federal University of São Carlos - UFSCar, São Carlos, Brazil.
J Asthma ; 59(8): 1568-1576, 2022 08.
Article em En | MEDLINE | ID: mdl-34252355
OBJECTIVE: To determine the accuracy of incremental Shuttle Walking Test (ISWT) in detecting exercise-induced bronchospasm (EIB) in adults with asthma and to verify whether there is an association of the drop in FEV1 between ISWT and cardiopulmonary exercise testing with constant-load CPET-CL. METHODS: In this cross-sectional study 32 individuals with asthma performed two ISWTs, an incremental cardiopulmonary exercise test (CPET-I) and a constant-load cardiopulmonary exercise test (CPET-CL) with na interval of 48 h between tests. Spirometric measurements were obtained 5, 10, 15, 20 and 30 min after exercise; an FEV1 decline > 10% was considered EIB. RESULTS: Fifteen individuals had EIB in both tests [χ2 = 9.41; κ = 0.46 p < 0.002 (95% CI: 0.201-0.708)], with moderate agreement. There was a significant correlation between the greatest variation in the drop in FEV1 between the ISWT and the CPET-CL (r = 0.48; p < 0.01). There was a significant difference for ventilation maintenance time above 40% of Maximum Voluntary Ventilation between the groups of positive EIB (p = 0.001) and negative EIB (p = 0.001) and for ventilatory demand (positive EIB group) (p = 0.008) between ISWT vs CPET-CL. Moreover, assuming CPET-CL as the criterion test, ISWT presented a sensitivity of 62.5% and specificity was 100%. CONCLUSION: ISWT showed moderate accuracy in detecting EIB in adults with asthma and was able to show similar metabolic and ventilatory demand presented in CPET-CL.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Asma Induzida por Exercício Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Revista: J Asthma Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Asma / Asma Induzida por Exercício Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Humans Idioma: En Revista: J Asthma Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil