Dual-Energy Computed Tomography Compared to Lung Perfusion Scintigraphy to Assess Pulmonary Perfusion in Patients Screened for Endoscopic Lung Volume Reduction.
Gietema, Hester A; Walraven, Kim H M; Posthuma, Rein; Mitea, Cristina; Slebos, Dirk-Jan; Vanfleteren, Lowie E G W.
Afiliação
  • Gietema HA; Department of Radiology and Nuclear Medicine, GROWSchool for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht, The Netherlands.
  • Walraven KHM; Department of Pulmonology, NUTRIMSchool of Nutrition and Translational Research in Metabolism, Maastricht University Medical Center+, Maastricht, The Netherlands.
  • Posthuma R; Department of Pulmonology, NUTRIMSchool of Nutrition and Translational Research in Metabolism, Maastricht University Medical Center+, Maastricht, The Netherlands.
  • Mitea C; Department of Pulmonology, Maastricht University Medical Center+, Maastricht, The Netherlands.
  • Slebos DJ; CIRO+, Center of Expertise for Chronic Organ Failure, Horn, The Netherlands.
  • Vanfleteren LEGW; Department of Radiology and Nuclear Medicine, GROWSchool for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht, The Netherlands.
Respiration ; 100(12): 1186-1195, 2021.
Article em En | MEDLINE | ID: mdl-34375973
ABSTRACT

BACKGROUND:

Endoscopic lung volume reduction (ELVR) using one-way endobronchial valves is a technique to reduce hyperinflation in patients with severe emphysema by inducing collapse of a severely destroyed pulmonary lobe. Patient selection is mainly based on evaluation of emphysema severity on high-resolution computed tomography and evaluation of lung perfusion with perfusion scintigraphy. Dual-energy contrast-enhanced CT scans may be useful for perfusion assessment in emphysema but has not been compared against perfusion scintigraphy.

AIMS:

The aim of the study was to compare perfusion distribution assessed with dual-energy contrast-enhanced computed tomography and perfusion scintigraphy. MATERIAL AND

METHODS:

Forty consecutive patients with severe emphysema, who were screened for ELVR, were included. Perfusion was assessed with 99mTc perfusion scintigraphy and using the iodine map calculated from the dual-energy contrast-enhanced CT scans. Perfusion distribution was calculated as usually for the upper, middle, and lower thirds of both lungs with the planar technique and the iodine overlay.

RESULTS:

Perfusion distribution between the right and left lung showed good correlation (r = 0.8). The limits of agreement of the mean absolute difference in percentage perfusion per region of interest were 0.75-5.6%. The upper lobes showed more severe perfusion reduction than the lower lobes. Mean difference in measured pulmonary perfusion ranged from -2.8% to 2.3%. Lower limit of agreement ranged from -8.9% to 4.6% and upper limit was 3.3-10.0%.

CONCLUSION:

Quantification of perfusion distribution using planar 99mTc perfusion scintigraphy and iodine overlays calculated from dual-energy contrast-enhanced CTs correlates well with acceptable variability.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Enfisema Pulmonar / Enfisema / Iodo Limite: Humans Idioma: En Revista: Respiration Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Enfisema Pulmonar / Enfisema / Iodo Limite: Humans Idioma: En Revista: Respiration Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Holanda