Humidity-Sensing Chipless RFID Tag with Enhanced Sensitivity Using an Interdigital Capacitor Structure.
Yeo, Junho; Lee, Jong-Ig; Kwon, Younghwan.
Afiliação
  • Yeo J; School of ICT Convergence, Daegu University, 201 Daegudae-ro, Gyeongsan 38453, Gyeongbuk, Korea.
  • Lee JI; Department of Applied Electronics Engineering, Dongseo University, Busan 47011, Korea.
  • Kwon Y; Department of Chemical Engineering, Daegu University, 201 Daegudae-ro, Gyeongsan 38453, Gyeongbuk, Korea.
Sensors (Basel) ; 21(19)2021 Sep 30.
Article em En | MEDLINE | ID: mdl-34640879
ABSTRACT
An eight-bit chipless radio frequency identification tag providing humidity sensing and identification information is proposed. A compact, enhanced-sensitivity resonator based on an interdigital capacitor (IDC) structure is designed for humidity sensing, whereas seven electric-field-coupled inductor capacitor (ELC) resonators are used for identification information. These eight resonators are placed in a two-by-four array arrangement. A step-by-step investigation for the effect of varying the number of elements and array configuration on the resonant frequency and radar cross-section (RCS) magnitude of the IDC resonator is conducted. The RCS value of the resonant peak frequency for the IDC resonator increases as the number of array elements placed nearby increases due to the mutual coupling among the elements, and the increase in the RCS value becomes larger as the number of arrays increases in the vertical direction. Polyvinyl alcohol (PVA) is coated on the IDC-based resonator at a thickness of 0.02 mm. A non-reflective temperature and humidity chamber is fabricated using Styrofoam, and the relative humidity (RH) is varied from 50% to 80% in 10% intervals at 25 °C in order to measure a bistatic RCS of the proposed tag. The humidity sensing performance of the IDC resonator in the proposed tag is measured by the shift in the resonant peak frequency and the RCS value, and is compared with a single ELC resonator. Experiment results show that when RH increased from 50% to 80%, the sensitivities of both the resonant peak frequency and the RCS value of the IDC resonator were better than those of the ELC resonator. The variation in the RCS value is much larger compared to the resonant peak frequency for both IDC and ELC resonators. In addition, the resonant peak frequency and RCS value of the PVA-coated IDC-based resonator change, whereas those of the other seven resonators without a PVA coating do not change.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2021 Tipo de documento: Article