Your browser doesn't support javascript.
loading
Evaluation of fresh, frozen, and lyophilized fecal samples by SPME and derivatization methods using GC×GC-TOFMS.
Nam, Seo Lin; Tarazona Carrillo, Kieran; de la Mata, A Paulina; de Bruin, Olle M; Doukhanine, Evgueni; Harynuk, James.
Afiliação
  • Nam SL; Department of Chemistry, University of Alberta, T6G 2G2, Edmonton, Alberta, Canada.
  • Tarazona Carrillo K; Department of Chemistry, University of Alberta, T6G 2G2, Edmonton, Alberta, Canada.
  • de la Mata AP; Department of Chemistry, University of Alberta, T6G 2G2, Edmonton, Alberta, Canada.
  • de Bruin OM; DNA Genotek, Ottawa, Ontario, Canada.
  • Doukhanine E; DNA Genotek, Ottawa, Ontario, Canada.
  • Harynuk J; Department of Chemistry, University of Alberta, T6G 2G2, Edmonton, Alberta, Canada. james.harynuk@ualberta.ca.
Metabolomics ; 18(4): 25, 2022 04 15.
Article em En | MEDLINE | ID: mdl-35426515
ABSTRACT

INTRODUCTION:

Feces is a highly complex matrix containing thousands of metabolites. It also contains live bacteria and enzymes, and does not have a static chemistry. Consequently, proper control of pre-analytical parameters is critical to minimize unwanted variations in the samples. However, no consensus currently exists on how fecal samples should be stored/processed prior to analysis.

OBJECTIVE:

The effects of sample handling conditions on fecal metabolite profiles and abundances were examined using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS).

METHODS:

Solid-phase microextraction (SPME) and derivatization via trimethylsilylation (TMS) were employed as complementary techniques to evaluate fresh, frozen, and lyophilized fecal samples with expanded coverage of the fecal metabolome. The total number of detected peaks and the signal intensities were compared among the different handling conditions.

RESULTS:

Our analysis revealed that the metabolic profiles of fecal samples depend greatly on sample handling and processing conditions, which had a more pronounced effect on results obtained by SPME than by TMS derivatization. Overall, lyophilization resulted in a greater amount of total and class-specific metabolites, which may be attributed to cell lysis and/or membrane disintegration.

CONCLUSIONS:

A comprehensive comparison of the sample handling conditions provides a deeper understanding of the physicochemical changes that occur within the samples during freezing and lyophilization. Based on our results, snap-freezing at -80 °C would be preferred over lyophilization for handling samples in the field of fecal metabolomics as this imparts the least change from the fresh condition.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microextração em Fase Sólida / Metabolômica Idioma: En Revista: Metabolomics Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microextração em Fase Sólida / Metabolômica Idioma: En Revista: Metabolomics Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Canadá