Your browser doesn't support javascript.
loading
The Scleral Cap Technique for Porous and Nonporous Orbital Implants.
Jordan, David R.
Afiliação
  • Jordan DR; University of Ottawa Eye Institute and the Ottawa Hospital, Ottawa, Ontario, Canada.
Ophthalmic Plast Reconstr Surg ; 39(1): 92-97, 2023.
Article em En | MEDLINE | ID: mdl-36598391
PURPOSE: To describe the results and potential benefit of a banked homologous donor scleral cap over the anterior surface of polyglactin 910 mesh-wrapped porous and nonporous orbital implants during enucleation and secondary orbital implant surgery. METHODS: This is a single center, retrospective, clinical case series of 83 patients who received a polyglactin 910 mesh (Vicryl knitted mesh, undyed, Ethicon, Sommerville, New Jersey, USA) wrapped bioceramic or polymethylmethacrylate orbital implant (sphere or mounded) following enucleation and secondary orbital implant surgery by one surgeon over a 10-year period. A homologous donor scleral cap (approximately 1.5 × 1.5 cm diameter) was also placed over the anterior mesh-wrapped implant surface as an additional barrier. A minimum of 1-year follow up was required to be included in the study. The author analyzed patient demographics, type of surgery, implant type, implant size, follow-up duration, and presence or absence of implant exposure. The data from patients with greater than 1-year follow up are detailed in this report. RESULTS: The author identified 100 patients in his case files that had a scleral cap put in place over their implant. Seventeen patients were either lost to follow up or did not have at least a 1-year follow up, leaving 83 patients (44 enucleations, 39 secondary implants) that were followed for 12 to 120 months (average 60.5 months). There were no cases of implant exposure identified in either group of patients during this time period. CONCLUSIONS: Implant exposure can occur anytime post implant placement with a porous or nonporous orbital implant. This review suggests that a homologous donor scleral cap (approximately 1.5 × 1.5 cm diameter) over the polyglactin 910 mesh-wrapped implant surface may help prevent implant exposure. Patients with porous and nonporous orbital implants should be followed on a long-term basis as exposure can occur at anytime postsurgery, even several years later.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Orbitários Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Revista: Ophthalmic Plast Reconstr Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Orbitários Tipo de estudo: Etiology_studies / Observational_studies Limite: Humans Idioma: En Revista: Ophthalmic Plast Reconstr Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Canadá