Your browser doesn't support javascript.
loading
Multi-isocenter VMAT craniospinal irradiation using feasibility dose-volume histogram-guided auto-planning technique.
Zhang, Yun; Huang, Yuling; Lin, Jiafan; Ding, Shenggou; Gong, Xiaochang; Liu, Qiegen; Gong, Changfei.
Afiliação
  • Zhang Y; Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang 330029, China.
  • Huang Y; Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang 330029, China.
  • Lin J; Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang 330029, China.
  • Ding S; Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang 330029, China.
  • Gong X; Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang 330029, China.
  • Liu Q; Department of Electronic Information Engineering, 999 Xuefu Dadao, Honggutan District, Nanchang 330031, China.
  • Gong C; Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang 330029, China.
J Radiat Res ; 2023 May 04.
Article em En | MEDLINE | ID: mdl-37141634
ABSTRACT
This study aims to propose a novel treatment planning methodology for multi-isocenter volumetric modulated arc therapy (VMAT) craniospinal irradiation (CSI) using the special feasibility dose-volume histogram (FDVH)-guided auto-planning (AP) technique. Three different multi-isocenter VMAT -CSI plans were created, including manually based plans (MUPs), conventional AP plans (CAPs) and FDVH-guided AP plans (FAPs). The CAPs and FAPs were specially designed by combining multi-isocenter VMAT and AP techniques in the Pinnacle treatment planning system. Specially, the personalized optimization parameters for FAPs were generated using the FDVH function implemented in PlanIQ software, which provides the ideal organs at risk (OARs) sparing for the specific anatomical geometry based on the valuable assumption of the dose fall-off. Compared to MUPs, CAPs and FAPs significantly reduced the dose for most of the OARs. FAPs achieved the best homogeneity index (0.092 ± 0.013) and conformity index (0.980 ± 0.011), while CAPs were slightly inferior to the FAPs but superior to the MUPs. As opposed to MUPs, FAPs delivered a lower dose to OARs, whereas the difference between FAPs and CAPs was not statistically significant except for the optic chiasm and inner ear_L. The two AP approaches had similar MUs, which were significantly lower than the MUPs. The planning time of FAPs (145.00 ± 10.25 min) was slightly lower than that of CAPs (149.83 ± 14.37 min) and was substantially lower than that of MUPs (157.92 ± 16.11 min) with P < 0.0167. Overall, introducing the multi-isocenter AP technique into VMAT-CSI yielded positive outcomes and may play an important role in clinical CSI planning in the future.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Radiat Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Radiat Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China