Your browser doesn't support javascript.
loading
Gadolinium K-edge angiography with a spectral photon counting CT in atherosclerotic rabbits.
Boccalini, Sara; Dessouky, Riham; Rodesch, Pierre-Antoine; Lacombe, Hugo; Yagil, Yoad; Lahoud, Elias; Erhard, Klaus; Brendel, Bernhard; Coulon, Philippe; Langlois, Jean-Baptiste; Chaput, Frederic; Parola, Stephane; Boussel, Loic; Lerouge, Frederic; Si-Mohamed, Salim; Douek, Philippe C.
Afiliação
  • Boccalini S; Lyon University, Université Claude Bernard Lyon 1, 69100 Villeurbanne, France; Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France. Electronic address: sara.boccalini@chu-lyon.fr.
  • Dessouky R; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France; Department of Radiology, Faculty of Medicine, Zagazig University, 44519, Zagazig, Egypt.
  • Rodesch PA; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France.
  • Lacombe H; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France.
  • Yagil Y; Philips Medical Systems, 31004 Haifa, Israel.
  • Lahoud E; Philips Medical Systems, 31004 Haifa, Israel.
  • Erhard K; Philips Research, 22335 Hamburg, Germany.
  • Brendel B; Philips Research, 22335 Hamburg, Germany.
  • Coulon P; Philips Healthcare, 92156 Suresnes, France.
  • Langlois JB; CERMEP Centre d'Imagerie du Vivant, 69500 Bron, France.
  • Chaput F; Laboratoire de Chimie, Université de Lyon, École Normale Supérieure de Lyon, Université Claude Bernard Lyon 1, CNRS UMR 5182, 69364 Lyon, France.
  • Parola S; Laboratoire de Chimie, Université de Lyon, École Normale Supérieure de Lyon, Université Claude Bernard Lyon 1, CNRS UMR 5182, 69364 Lyon, France.
  • Boussel L; Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France.
  • Lerouge F; Laboratoire de Chimie, Université de Lyon, École Normale Supérieure de Lyon, Université Claude Bernard Lyon 1, CNRS UMR 5182, 69364 Lyon, France.
  • Si-Mohamed S; Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France.
  • Douek PC; Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France; Lyon University, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, 69100 Villeurbanne, France.
Diagn Interv Imaging ; 104(10): 490-499, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37248095
ABSTRACT

PURPOSE:

The purpose of this study was to investigate the feasibility of gadolinium-K-edge-angiography (angio-Gd-K-edge) with gadolinium-based contrast agents (GBCAs) as obtained with spectral photon counting CT (SPCCT) in atherosclerotic rabbits. MATERIALS AND

METHODS:

Seven atherosclerotic rabbits underwent angio-SPCCT acquisitions with two GBCAs, with similar intravenous injection protocol. Conventional and angio-Gd-K-edge images were reconstructed with the same parameters. Regions of interest were traced in different locations of the aorta and its branches. Hounsfield unit values, Gd concentrations, signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated and compared. The maximum diameter and the diameter of the aorta in regard to atherosclerotic plaques were measured by two observers. Images were subjectively evaluated regarding vessels' enhancement, artefacts, border sharpness and overall image quality.

RESULTS:

In the analyzable six rabbits, Gd-K-edge allowed visualization of target vessels and no other structures. HU values and Gd concentrations were greatest in the largest artery (descending aorta, 5.6 ± 0.8 [SD] mm), and lowest in the smallest (renal arteries, 2.1 ± 0.3 mm). While greater for conventional images, CNR and SNR were satisfactory for both images (all P < 0.001). For one observer there were no statistically significant differences in either maximum or plaque-diameters (P = 0.45 and all P > 0.05 in post-hoc analysis, respectively). For the second observer, there were no significant differences for images reconstructed with the same parameters (all P < 0.05). All subjective criteria scored higher for conventional images compared to K-edge (all P < 0.01), with the highest scores for enhancement (4.3-4.4 vs. 3.1-3.4).

CONCLUSION:

With SPCCT, angio-Gd-K-edge after injection of GBCAs in atherosclerotic rabbits is feasible and allows for angiography-like visualization of small arteries and for the reliable measurement of their diameters.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Gadolínio Limite: Animals Idioma: En Revista: Diagn Interv Imaging Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Gadolínio Limite: Animals Idioma: En Revista: Diagn Interv Imaging Ano de publicação: 2023 Tipo de documento: Article