Your browser doesn't support javascript.
loading
Mutual interference between 3,6-dichlorinated carbazole and p,p'-dichlorodiphenyltrichloroethane in gas chromatography mass spectrometry analysis.
Zhou, Shanshan; Su, Qi; Zhong, Dan; Guo, Jiehong; Liu, Jinsong; Li, An.
Afiliação
  • Zhou S; College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China. sszhou@zjut.edu.cn.
  • Su Q; College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China.
  • Zhong D; College of Environment, Zhejiang University of Technology, Hangzhou, 310014, China.
  • Guo J; School of Public Health, University of Illinois Chicago, Chicago, IL, 60612, USA.
  • Liu J; Department of Civil, Environmental, and Geospatial Engineering, Houghton, MI, 49931, USA.
  • Li A; Zhejiang Province of Environmental Monitoring Center, Hangzhou, 310012, China.
Environ Monit Assess ; 195(10): 1195, 2023 Sep 12.
Article em En | MEDLINE | ID: mdl-37698675
ABSTRACT
The widespread contamination of the environment by polyhalogenated carbazoles (PHCZs) has been increasingly observed during the past decade. Among numerous PHCZ congeners, 3,6-dichlorocarbazole (36-CCZ) is often among the most frequently detected at higher concentrations. Although the environmental level of the legacy pesticide p,p'-dichlorodiphenyltrichloroethane (p,p'-DDT) has been declining, it continues to be ubiquitously detected. These two compounds were found to interfere with each other during analyses using gas chromatography (GC) coupled with single- or triple-quadrupole low-resolution mass spectrometry (MS or MS/MS). The base peak in the mass spectra was that of m/z 235 for both compounds. In MS/MS with multiple reaction monitoring (MRM), the same transitions (235 → 200 and 235 → 165) were often used. Under the same GC operating conditions, the SH-I-5MS capillary column used in this work did not resolve the two compounds at baseline. Pre-treatment using cleanup column chromatography can fractionate the sample extract, with the two compounds separated in different fractions before instrumental analyses. Reversed-phase HPLC columns also work for resolving 36-CCZ and p,p'-DDT. Possible overlaps in GC retention and similarity in MS spectra might have caused data inaccuracy for 36-CCZ as well as p,p'-DDT in some studies published to date, and steps to avoid the interference should be taken into quality control protocols in future research and environmental monitoring.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DDT / Espectrometria de Massas em Tandem Tipo de estudo: Guideline Idioma: En Revista: Environ Monit Assess Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DDT / Espectrometria de Massas em Tandem Tipo de estudo: Guideline Idioma: En Revista: Environ Monit Assess Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China