Your browser doesn't support javascript.
loading
Robot-Assisted Renal Surgery with the New Hugo Ras System: Trocar Placement and Docking Settings.
Prata, Francesco; Raso, Gianluigi; Ragusa, Alberto; Iannuzzi, Andrea; Tedesco, Francesco; Cacciatore, Loris; Civitella, Angelo; Tuzzolo, Piergiorgio; D'Addurno, Giuseppe; Callè, Pasquale; Basile, Salvatore; Fantozzi, Marco; Pira, Matteo; Prata, Salvatore Mario; Anceschi, Umberto; Simone, Giuseppe; Scarpa, Roberto Mario; Papalia, Rocco.
Afiliação
  • Prata F; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Raso G; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Ragusa A; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Iannuzzi A; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Tedesco F; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Cacciatore L; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Civitella A; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Tuzzolo P; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • D'Addurno G; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Callè P; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Basile S; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Fantozzi M; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Pira M; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Prata SM; Simple Operating Unit of Lower Urinary Tract Surgery, SS. Trinità Hospital, Sora, 03039 Frosinone, Italy.
  • Anceschi U; Department of Urology, IRCCS "Regina Elena" National Cancer Institute, 00144 Rome, Italy.
  • Simone G; Department of Urology, IRCCS "Regina Elena" National Cancer Institute, 00144 Rome, Italy.
  • Scarpa RM; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
  • Papalia R; Department of Urology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy.
J Pers Med ; 13(9)2023 Sep 13.
Article em En | MEDLINE | ID: mdl-37763140
The current literature relating to the novel HugoTM RAS System lacks consistent data concerning the bedside features of robot-assisted partial nephrectomy (RAPN). To describe the trocar placement and docking settings for RAPN with a three-arm configuration to streamline the procedure with HugoTM RAS, between October 2022 and April 2023, twenty-five consecutive off-clamp RAPNs for renal tumors with the HugoTM RAS System were performed. We conceived a trouble-free three-arm setting to ease and standardize RAPN trocar placement and docking settings with HugoTM RAS. Perioperative data were collected. Post-operative complications were reported according to the Clavien-Dindo classification. The eGFR was calculated according to the CKD-EPI formula. Continuous variables were presented as the median and IQR, while frequencies were reported as categorical variables. Off-clamp RAPNs were successfully performed in all cases without the need for conversion or additional port placement. The median age and BMI were 69 years (IQR, 60-73) and 27.3 kg/m2 (IQR, 25.7-28.1), respectively. The median tumor size and R.E.N.A.L. score were 32.5 mm (IQR, 26-43.7) and 6 (IQR, 5-7), respectively. Two patients were affected by cT2 renal tumors. The median docking and console time were 5 (IQR, 5-6) and 90 min (IQR, 68-135.75 min), respectively, with slightly progressive improvements in the docking time achieved. No intraoperative complications occurred alongside clashes between instruments or with the bed assistant. In experienced hands, this simplified three-instrument configuration of the HugoTM RAS System for off-clamp RAPN resulted in feasible and safe practice, providing patient-tailored trocar placement and docking with non-inferior peri-perioperative outcomes to other robotic platforms.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Pers Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Pers Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália