Your browser doesn't support javascript.
loading
Enhanced morphological assessment based on interocular asymmetry analysis for keratoconus detection.
Dong, Ruilan; Liu, Yan; Zhang, Yu; Chen, Yueguo.
Afiliação
  • Dong R; Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, China.
  • Liu Y; Beijing Key Laboratory of Restoration of Damaged Ocular Nerve, Peking University Third Hospital, Beijing, China.
  • Zhang Y; Peking University Institute of Laser Medicine, Beijing, China.
  • Chen Y; Department of Ophthalmology, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing, 100191, China.
Graefes Arch Clin Exp Ophthalmol ; 262(3): 913-926, 2024 Mar.
Article em En | MEDLINE | ID: mdl-37792068
ABSTRACT

PURPOSE:

To clarify the interocular asymmetry of corneal morphological descriptors and evaluate its discriminant ability of keratoconus (KC).

METHODS:

This retrospective study recruited 344 normal participants and 290 KC patients, randomized to training and validation datasets. Interocular correlation and agreement were evaluated on 44 corneal morphological descriptors derived from Schiempflug tomography. Logistic regression models were constructed using binocular data and of which diagnostic performance was evaluated using the area under receiver operating characteristics curve (AUC), net reclassification improvement (NRI), and integrated discrimination improvement (IDI).

RESULTS:

Interocular agreement of corneal descriptors is better in the normal than in KC except for dimensions of cornea and anterior chamber. The interocular asymmetry increases along with the severity of KC. Interocular asymmetry in maximum anterior keratometry, mean anterior keratometry and higher-order aberrations of anterior surface show high AUC above 0.950. Binocular logistic regression index reaches an AUC of 0.963 with high specificity (95.2%) and brings gain to monocular parameters in distinguishing the normal eyes from KC (NRI = 0.080 (0.042 ~ 0.118), P < 0.001) and IDI = 0.071 (0.049 ~ 0.092), P < 0.001). Interocular asymmetry benefits even more in subclinical keratoconus (SKC) detection reflected by NRI (0.4784 (0.2703-0.6865), P < 0.001) and IDI (0.2680 (0.1495-0.3866), P < 0.001) measures.

CONCLUSION:

Interocular asymmetry is a well-characterized feature of KC and related to the severity. It is feasible to apply the interocular asymmetry in diagnosis of KC and SKC as a replenishment of monocular parameters and in progression tracking.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ceratocone Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ceratocone Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Graefes Arch Clin Exp Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China