Absolute calibration of a streaked optical pyrometer at nanosecond time scale with a luminescent concentrator.
Nourry-Martin, M; Denoeud, A; Chollet, C; Bonneau, M; Vinci, T; Ravasio, A; Brygoo, S; Darbon, S; Balembois, F.
Afiliação
  • Nourry-Martin M; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Denoeud A; Université Paris-Saclay, Institut d'Optique Graduate School, CNRS, Laboratoire Charles Fabry, 91127 Palaiseau, France.
  • Chollet C; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Bonneau M; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Vinci T; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Ravasio A; LULI, CNRS, CEA, Sorbonne Université, Ecole Polytechnique-Institut Polytechnique de Paris, F-91128 Palaiseau, France.
  • Brygoo S; LULI, CNRS, CEA, Sorbonne Université, Ecole Polytechnique-Institut Polytechnique de Paris, F-91128 Palaiseau, France.
  • Darbon S; CEA, DAM, DIF, F-91297 Arpajon, France.
  • Balembois F; CEA, DAM, DIF, F-91297 Arpajon, France.
Rev Sci Instrum ; 94(8)2023 Aug 01.
Article em En | MEDLINE | ID: mdl-38065135
ABSTRACT
The Streaked Optical Pyrometer (SOP) is a visible diagnostic widely used to study the warm dense matter regime at high energy laser facilities, gas guns, or ion accelerators. It is usually coupled with a Velocity Interferometer System for Any Reflector (VISAR) diagnostic for simultaneous shock wave velocity, reflectivity, and temperature measurements to study the Equation of State (EOS) of materials. While VISAR is a well-mastered technology that provides velocity measurements with low relative uncertainties (close to percent), SOP diagnostics still suffer from high imprecision. In this article, we present a new calibration method in order to obtain absolute temperature measurements with reduced uncertainties. This approach is based on a novel light source a CeYAG luminescent concentrator pumped by LEDs. This device produces enough optical power for calibration at the nanosecond sweep duration of the streak camera. As a demonstration, it has first been installed at the LULI facility and tested on quartz samples shocked at temperatures above 4000 K.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2023 Tipo de documento: Article País de afiliação: França