Your browser doesn't support javascript.
loading
UiO-66-NH2 Metal-Organic Framework for the Detection of Alzheimer's Biomarker Aß (1-42).
Fan, Qingqing; Wang, Junrong; Biazik, Joanna M; Geng, Shu; Mazur, Federico; Li, Yuhuan; Ke, Pu Chun; Chandrawati, Rona.
Afiliação
  • Fan Q; School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, New South Wales 2052, Australia.
  • Wang J; School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, New South Wales 2052, Australia.
  • Biazik JM; Electron Microscopy Unit, Mark Wainwright Analytical Centre, The University of New South Wales, Sydney, New South Wales 2052, Australia.
  • Geng S; School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, New South Wales 2052, Australia.
  • Mazur F; School of Chemical Engineering and Australian Centre for Nanomedicine (ACN), The University of New South Wales, Sydney, New South Wales 2052, Australia.
  • Li Y; Liver Cancer Institute, Zhongshan Hospital, Key Laboratory of Carcinogenesis and Cancer Invasion, Ministry of Education, Fudan University, Shanghai 200032, China.
  • Ke PC; Nanomedicine Center, The Great Bay Area National Institute for Nanotechnology Innovation, 136 Kaiyuan Avenue, Guangzhou 510700, China.
  • Chandrawati R; Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, Victoria 3052, Australia.
ACS Appl Bio Mater ; 7(1): 182-192, 2024 01 15.
Article em En | MEDLINE | ID: mdl-38126321
ABSTRACT
Neurodegenerative disorders pose a significant challenge to global healthcare, with Alzheimer's disease (AD) being one of the most prevalent forms. Early and accurate detection of amyloid-ß (Aß) (1-42) monomers, a key biomarker of AD pathology, is crucial for effective diagnosis and intervention of the disease. Current gold standard detection techniques for Aß include enzyme-linked immunosorbent assay and surface plasmon resonance. Although reliable, they are limited by their cost and time-consuming nature, thus restricting their point-of-care applicability. Here we present a sensitive and rapid colorimetric sensor for the detection of Aß (1-42) monomers within 5 min. This was achieved by harnessing the peroxidase-like activity of metal-loaded metal-organic frameworks (MOFs), specifically UiO-66-NH2, coupled with the strong affinity of Aß (1-42) to the MOFs. Various metal-loaded MOFs were synthesized and investigated, and platinum-loaded UiO-66-NH2 was identified as the optimal candidate for our purpose. The Pt-loaded UiO-66-NH2 sensor demonstrated detection limits of 2.76 and 4.65 nM Aß (1-42) monomers in water and cerebrospinal fluid, respectively, with a linear range from 0.75 to 25 nM (R2 = 0.9712), outperforming traditional detection techniques in terms of both detection time and complexity. Moreover, the assay was specific toward Aß (1-42) monomers when evaluated against interfering compounds. The rapid and cost-effective sensor may help circumvent the limitations of conventional detection methods, thus providing a promising avenue for early AD diagnosis and facilitating improved clinical outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Ácidos Ftálicos / Doença de Alzheimer / Estruturas Metalorgânicas Limite: Humans Idioma: En Revista: ACS Appl Bio Mater Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Ácidos Ftálicos / Doença de Alzheimer / Estruturas Metalorgânicas Limite: Humans Idioma: En Revista: ACS Appl Bio Mater Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália