LC-ESI-HRMS - lipidomics of phospholipids : Characterization of extraction, chromatography and detection parameters.
Rund, Katharina M; Carpanedo, Laura; Lauterbach, Robin; Wermund, Tim; West, Annette L; Wende, Luca M; Calder, Philip C; Schebb, Nils Helge.
Afiliação
  • Rund KM; Chair of Food Chemistry, Faculty of Mathematics and Natural Sciences, University of Wuppertal, Gaussstr. 20, 42119, Wuppertal, Germany.
  • Carpanedo L; Chair of Food Chemistry, Faculty of Mathematics and Natural Sciences, University of Wuppertal, Gaussstr. 20, 42119, Wuppertal, Germany.
  • Lauterbach R; Chair of Food Chemistry, Faculty of Mathematics and Natural Sciences, University of Wuppertal, Gaussstr. 20, 42119, Wuppertal, Germany.
  • Wermund T; Chair of Food Chemistry, Faculty of Mathematics and Natural Sciences, University of Wuppertal, Gaussstr. 20, 42119, Wuppertal, Germany.
  • West AL; School of Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, UK.
  • Wende LM; Chair of Food Chemistry, Faculty of Mathematics and Natural Sciences, University of Wuppertal, Gaussstr. 20, 42119, Wuppertal, Germany.
  • Calder PC; School of Human Development and Health, Faculty of Medicine, University of Southampton, Southampton, UK.
  • Schebb NH; National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University Hospital Southampton NHS Foundation Trust and University of Southampton, Southampton, UK.
Anal Bioanal Chem ; 416(4): 925-944, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38214704
ABSTRACT
Lipids are a diverse class of molecules involved in many biological functions including cell signaling or cell membrane assembly. Owing to this relevance, LC-MS/MS-based lipidomics emerged as a major field in modern analytical chemistry. Here, we thoroughly characterized the influence of MS and LC settings - of a Q Exactive HF operated in Full MS/data-dependent MS2 TOP N acquisition mode - in order to optimize the semi-quantification of polar lipids. Optimization of MS-source settings improved the signal intensity by factor 3 compared to default settings. Polar lipids were separated on an ACQUITY Premier CSH C18 reversed-phase column (100 × 2.1 mm, 1.7 µm, 130 Å) during an elution window of 28 min, leading to a sufficient number of both data points across the chromatographic peaks, as well as MS2 spectra. Analysis was carried out in positive and negative ionization mode enabling the detection of a broader spectrum of lipids and to support the structural characterization of lipids. Optimal sample preparation of biological samples was achieved by liquid-liquid extraction using MeOH/MTBE resulting in an excellent extraction recovery > 85% with an intra-day and inter-day variability < 15%. The optimized method was applied on the investigation of changes in the phospholipid pattern in plasma from human subjects supplemented with n3-PUFA (205 and 226). The strongest increase was observed for lipids bearing 205, while 224 bearing lipids were lowered. Specifically, LPC 205_00 and PC 160_205 were found to be strongest elevated, while PE 180_224 and PC 182_182 were decreased by n3-PUFA supplementation. These results were confirmed by targeted LC-MS/MS using commercially available phospholipids as standards.