Cerebral blood flow dynamics during cardiac surgery in infants.
Leth-Olsen, Martin; Døhlen, Gaute; Torp, Hans; Nyrnes, Siri Ann.
Afiliação
  • Leth-Olsen M; Department of Circulation and Medical Imaging (ISB), Faculty of Medicine and Health Sciences, NTNU-Norwegian University of Science and Technology, Trondheim, Norway. martin.leth-olsen@ntnu.no.
  • Døhlen G; Children's Clinic, St Olav's University Hospital, Trondheim, Norway. martin.leth-olsen@ntnu.no.
  • Torp H; Department of Pediatric Cardiology, Oslo University Hospital, Oslo, Norway.
  • Nyrnes SA; Department of Circulation and Medical Imaging (ISB), Faculty of Medicine and Health Sciences, NTNU-Norwegian University of Science and Technology, Trondheim, Norway.
Pediatr Res ; 2024 Apr 03.
Article em En | MEDLINE | ID: mdl-38570558
ABSTRACT

BACKGROUND:

In this pilot study, we investigated continuous cerebral blood flow velocity measurements to explore cerebrovascular hemodynamics in infants with congenital heart disease undergoing cardiac surgery.

METHODS:

A non-invasive transfontanellar cerebral Doppler monitor (NeoDoppler) was used to monitor 15 infants (aged eight days to nine months) during cardiac surgery with cardiopulmonary bypass. Numerical and visual analyses were conducted to assess trends and events in Doppler measurements together with standard monitoring equipment. The mean flow index, calculated as the moving Pearson correlation between mean arterial pressure and time averaged velocity, was utilized to evaluate dynamic autoregulation. Two levels of impaired autoregulation were defined (Mean flow index >0.3/0.45), and percentage of time above these limits were calculated.

RESULTS:

High quality recordings were achieved during 90.6% of the monitoring period. There was a significant reduction in time averaged velocity in all periods of cardiopulmonary bypass. All patients showed a high percentage of time with impaired dynamic autoregulation, with Mean flow index >0.3 and 0.45 73.71% ± 9.06% and 65.16% ± 11.27% respectively. Additionally, the system promptly detected hemodynamic events.

CONCLUSION:

Continuous transfontanellar cerebral Doppler monitoring could become an additional tool in enhancing cerebral monitoring in infants during cardiac surgery. IMPACT This pilot study demonstrates the feasibility of continuous transfontanellar Doppler monitoring of cerebral blood flow velocities during cardiac surgery in infants. It also demonstrates a high proportion of time with impaired cerebral autoregulation during cardiac surgery based on the Mean flow index. Continuous transfontanellar Doppler could become a useful tool to improve cerebral monitoring and provide new pathophysiological insight.