Your browser doesn't support javascript.
loading
Comparative Evaluation of Stress Distribution Against the Root Canal Wall at Three Different Levels by Using TruNatomy, XP-endo Shaper, F360, and 2Shape Files-A Finite Element Analysis.
Singh, Rimjhim; Dubey, Sandeep; Singh, Palak; Samant, Praveen Singh; Gupta, Rajat.
Afiliação
  • Singh R; Department of Conservative Dentistry and Endodontics, Babu Banarasi Das College of Dental Sciences, Babu Banarasi Das University, Lucknow, India.
  • Dubey S; Department of Conservative Dentistry and Endodontics, Babu Banarasi Das College of Dental Sciences, Babu Banarasi Das University, Lucknow, India.
  • Singh P; Department of Conservative Dentistry and Endodontics, Babu Banarasi Das College of Dental Sciences, Babu Banarasi Das University, Lucknow, India.
  • Samant PS; Department of Conservative Dentistry and Endodontics, Babu Banarasi Das College of Dental Sciences, Babu Banarasi Das University, Lucknow, India.
  • Gupta R; Department of Metallurgical Engineering, Indian Institute of Technology BHU (IIT-BHU) Varanasi, India.
Eur Endod J ; 9(3): 243-251, 2024 08 22.
Article em En | MEDLINE | ID: mdl-38619222
ABSTRACT

OBJECTIVE:

The aim of this in vitro study was to assess the stress distribution of novel endodontic rotary files of different cross sections and metallurgy against the root canal wall at three different levels by using finite element analysis.

METHODS:

A total of 60 novel NiTi rotary files were included in this study after being scanned for any surface deformities using a scanning electron microscope. The scanned files were assigned into 4 groups of 15 samples each based on their metallurgy and

design:

Group A-TruNatomy, Group B-XP-endo Shaper, Group C-F360, and Group D-2shape files. ANSYS® 15 Workbench finite element software (Canonsburg, Pennsylvania, United States) was used to numerically analyse the stress created by computer-aided models of these instruments on the dentinal wall of a simulated root canal to test the mechanical behaviour of these files. All data were analysed using one-way ANOVA with post hoc Tukey analysis, the Shapiro Wilk test, and Levene's test. The significance level was set at 5%.

RESULTS:

XP-endo Shaper files employed minimal stress on the surface of dentine during instrumentation, and F360 files exerted maximum stress on the dentinal wall. However, no statistically significant difference was found among the groups in relation to the amount of stress produced at the distinct levels of the root canal wall (p>0.05).

CONCLUSION:

There was no discernible difference in stress generation among the four groups in the current investigation. Therefore, it can be inferred that the upgrade in design and metallurgy of rotary files has the potential to downgrade the stress during the shaping of the canal and the menace of instrument breakage during their clinical usage.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise de Elementos Finitos Limite: Humans Idioma: En Revista: Eur Endod J Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise de Elementos Finitos Limite: Humans Idioma: En Revista: Eur Endod J Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia