Your browser doesn't support javascript.
loading
Evaluation of the oscillometric method for noninvasive blood pressure measurement during cuff deflation and cuff inflation with reference to intra-arterial blood pressure.
Celler, Branko G; Yong, Andy; Rubenis, Imants; Butlin, Mark; Argha, Ahmadreza; Rehan, Rajan; Avolio, Alberto.
Afiliação
  • Celler BG; Biomedical Systems Research Laboratory, University of New South Wales.
  • Yong A; Concord Repatriation Hospital, Cardiology, University of Sydney.
  • Rubenis I; Faculty of Medicine, Health and Human Sciences, Macquarie University.
  • Butlin M; Concord Repatriation Hospital, Cardiology, University of Sydney.
  • Argha A; Faculty of Medicine, Health and Human Sciences, Macquarie University.
  • Rehan R; Graduate School of Biomedical Engineering, University of New South Wales, Sydney, Australia.
  • Avolio A; Concord Repatriation Hospital, Cardiology, University of Sydney.
J Hypertens ; 42(7): 1235-1247, 2024 Jul 01.
Article em En | MEDLINE | ID: mdl-38690876
ABSTRACT
There is little quantitative clinical data available to support blood pressure measurement accuracy during cuff inflation. In this study of 35 male and 5 female lightly anaesthetized subjects aged 64.1 ±â€Š9.6 years, we evaluate and compare the performance of both the oscillometric ratio and gradient methods during cuff deflation and cuff inflation with reference to intra-arterial measurements. We show that the oscillometric waveform envelopes (OWE), which are key to both methods, exhibit significant variability in both shape and smoothness leading to at least 15% error in the determination of mean pressure (MP). We confirm the observation from our previous studies that K1 Korotkoff sounds underestimate systolic blood pressure (SBP) and note that this underestimation is increased during cuff inflation. The estimation of diastolic blood pressure (DBP) is generally accurate for both the ratio and the gradient method, with the latter showing a significant increase during inflation. Since the gradient method estimates SBP and DBP from points of maximum gradient on each OWE recorded, it may offer significant benefits over the ratio method. However, we have shown that the ratio method can be optimized for any data set to achieve either a minimum mean error (ME) of close to 0 mmHg or minimum root mean square error (RMSE) with standard deviation (SD) of <5.0 mmHg. We conclude that whilst cuff inflation may offer some advantages, these are neither significant nor substantial, leaving as the only benefit, the potential for more rapid measurement and less patient discomfort.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oscilometria / Pressão Sanguínea / Determinação da Pressão Arterial Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Hypertens Ano de publicação: 2024 Tipo de documento: Article