A novel surgical technique for revision anterior cruciate ligament reconstruction using an isolated rectus femoris tendon autograft.
Arch Orthop Trauma Surg
; 144(6): 2723-2730, 2024 Jun.
Article
em En
| MEDLINE
| ID: mdl-38753014
ABSTRACT
INTRODUCTION:
Only a few anatomic studies have described an isolated rectus femoris tendon autograft for anterior cruciate ligament (ACL) reconstruction. This study aims to demonstrate a new surgical technique utilising the rectus femoris tendon for ACL reconstruction. This study hypothesises that the rectus tendon autograft will yield satisfying postoperative outcomes in terms of stability, with minimal complications at the harvest site.METHODS:
This retrospective study investigated the outcomes of 28 revision ACL reconstructions using a rectus tendon autograft with a mean follow-up of 41.7 (range, 24.0-64.8) months. A 3 cm longitudinal incision was used to harvest the rectus tendon with an open tendon stripper. Intraoperative collected data included the length of the tendon and thickness of a 4-fold graft. Further outcome parameters include anterior cruciate ligament stability and range of motion. Additionally, postoperative complications, especially donor site morbidity, were documented in type and frequency.RESULTS:
The mean tendon length measured 32.4 cm (range, 30-35 cm). After preparing a 4-fold graft, the mean diameter was 9.2 mm (range, 8.0-10 mm) at the tibial and 9.0 mm (range, 7.5-10 mm) at the femoral end. Stability evaluated by the Lachman test improved significantly from 2 (Interquartile range (IQR), 2-3) preoperatively to 0 (IQR, 0-1) postoperatively (p < .001). Rerupture of the anterior cruciate ligament graft was observed in 2 patients (7.1%). Four patients showed a persistent extension deficit of about 5 degrees postoperatively. Two of them underwent revision surgery due to a Cyclops lesion. Only one patient complained of prolonged pain at the harvest site (3.6%).CONCLUSION:
The 4-fold rectus tendon represents a novel autograft technique in revision ACL reconstruction. This study provides evidence of appropriate graft dimensions and satisfying postoperative outcomes regarding stability. The technique is associated with a low complication rate at the harvest site. STUDYDESIGN:
Case series; Level of evidence, IV.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Reoperação
/
Tendões
/
Reconstrução do Ligamento Cruzado Anterior
/
Autoenxertos
Limite:
Adolescent
/
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Arch Orthop Trauma Surg
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Áustria