Your browser doesn't support javascript.
loading
Multimodal preoperative imaging for transcatheter mitral valve replacement in the domestic sheep model.
Carney, John P; Bianco, Richard W.
Afiliação
  • Carney JP; Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Minneapolis, 425 East River Parkway KE B18, Minneapolis, MN, 55455, USA. carne115@umn.edu.
  • Bianco RW; Experimental Surgical Services Laboratory, Department of Surgery, University of Minnesota Minneapolis, 425 East River Parkway KE B18, Minneapolis, MN, 55455, USA.
Sci Rep ; 14(1): 11745, 2024 05 23.
Article em En | MEDLINE | ID: mdl-38778204
ABSTRACT
Preclinical in vivo evaluation is an essential step in the progression of new cardiac devices into patient use, with studies predominantly performed in the domestic sheep model. A growing area of interest in cardiac device development is transcatheter mitral valve replacement (TMVR). Clinically, multimodal imaging, or computed tomography (CT) and echocardiography (echo) are used extensively to preoperatively determine mitral valve morphology prior to an intervention, but there is no description on how these modalities can be implemented to support preclinical studies. The purpose of this study is to apply clinically relevant CT and echo acquisition and assessment techniques to a large group of naive research sheep in order to analyze and report modality-related effects on mitral valve dimensional reference intervals in the sheep model. To this end, fifty-five adult domestic sheep underwent preoperative CT and echo exams and resultant images were analyzed using a landmark-based multiplanar measurement protocol and compiled into a master dataset for statistical analysis. We found moderate agreement between CT and echo-derived measurements of the mitral valve in sheep and propose the first clinically-relevant dimensional indices for the sheep's naive mitral valve which can be used to guide future studies evaluating novel TMVR devices. This study is the first of its kind in proposing a reproducible method for detailed examination of the mitral valve in the sheep model using clinically-relevant multimodal imaging. As in patients, CT and echo can reveal accurate native mitral valve dimensions in the sheep prior to preclinical TMVR studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Tomografia Computadorizada por Raios X / Implante de Prótese de Valva Cardíaca / Imagem Multimodal / Valva Mitral Limite: Animals Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Tomografia Computadorizada por Raios X / Implante de Prótese de Valva Cardíaca / Imagem Multimodal / Valva Mitral Limite: Animals Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos