Your browser doesn't support javascript.
loading
Mechanical evaluation of a threaded interference interlocking mechanism for angle-stable intramedullary nailing.
Am J Vet Res ; 85(7)2024 Jul 01.
Article em En | MEDLINE | ID: mdl-38848749
ABSTRACT

OBJECTIVE:

To assess the fatigue and load-to-failure mechanical characteristics of an intramedullary nail with a threaded interference design (TID) in comparison to a commercially available veterinary angle-stable nail with a Morse taper bolt design (I-Loc) of an equivalent size.

METHODS:

10 single interlocking screw/bolt constructs of TID and I-Loc implants were assembled using steel pipe segments and placed through 50,000 cycles of simulated, physiologic axial or torsional loading. Entry torque, postfatigue extraction torque, and 10th, 25,000th, and 50,000th cycle torsional toggle were assessed. Each construct was then loaded to failure in the same respective direction as fatigue testing. Four complete constructs of each design were then assessed using a synthetic bone analog with a 50-mm central defect via nondestructive torsional and axial loading followed by axial load to failure.

RESULTS:

All constructs were angle stable at all time points and withstood fatigue loading. Median insertional torque, extraction torque-to-insertion torque ratio, and torsional yield load were 33%, 33%, and 72.5% lower, respectively, for the TID interlocking screws. No differences in torsional peak load, torsional stiffness, axial yield load, axial stiffness, or axial peak load were identified. No differences in complete construct angle stability, torsional stiffness, axial peak load, axial stiffness, or axial yield load were identified. CLINICAL RELEVANCE The TID had an inferior torsional yield load when compared to I-Loc implants but generated angle stability and sustained simulated physiologic fatigue loading. The TID may be a suitable mechanism for generating angle stability in interlocking nails.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pinos Ortopédicos / Torque / Fixação Intramedular de Fraturas Limite: Animals Idioma: En Revista: Am J Vet Res Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pinos Ortopédicos / Torque / Fixação Intramedular de Fraturas Limite: Animals Idioma: En Revista: Am J Vet Res Ano de publicação: 2024 Tipo de documento: Article