Your browser doesn't support javascript.
loading
Biosafety assessments of hexafluoropropylene trimer derivative as a fluorinated cooling fluid for electronics.
Zhou, Yi-Tong; Zhang, Pei-Jie; Wang, Shu-Ping; Li, Chang-Hao; Zhang, Jia-Qing; Zhang, Wei-Xin; Zhao, Yuan-Di; Cao, Yuan-Cheng; Fan, Jin-Xuan.
Afiliação
  • Zhou YT; College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074 Hubei China.
  • Zhang PJ; College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074 Hubei China.
  • Wang SP; State Grid Anhui Electric Power Co., Ltd, Hefei, 518001 Anhui China.
  • Li CH; State Grid Anhui Electric Power Co., Ltd, Hefei, 518001 Anhui China.
  • Zhang JQ; State Grid Anhui Electric Power Co., Ltd, Hefei, 518001 Anhui China.
  • Zhang WX; State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, 430074 Hubei China.
  • Zhao YD; College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074 Hubei China.
  • Cao YC; State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, 430074 Hubei China.
  • Fan JX; College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074 Hubei China.
Toxicol Res ; 40(3): 431-440, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38911548
ABSTRACT
The Internet Data Center (IDC) is one of the most important infrastructures in the field of information technology. The cooling system for heat dissipation of IDC is indispensable due to it generates a large amount of heat during its calculation process, which may potentially harm its normal operation. Electronic fluorinated fluids have been widely used in cooling systems of IDC with stable physical and chemical properties. However, the biological toxicity of electronic fluorinated fluids has not been fully evaluated and there is a lack of unified safety standards, which may pose potential risks to the environment and human health. Here, hexafluoropropylene terpolymer (HFPT) as an example has been systematically studied, fully considering the application scenarios of data centers. Also, the emergency effects of fluorinated coolants in mammalian models from the perspectives of inhalation, skin contact, accidental entry into eyes, accidental ingestion, and chronic toxicity, are evaluated. Multiple in vivo experiments have proven that HFPT not only has stable physical and chemical properties, that can maintain the safe operation of IDC, but also has low physiological toxicity to mammals and can provide health benefits to data center staff and the assurance of surrounding environment. This study proves the good biological safety of electronic fluorinated fluids and provides a reference for environmental assessment and risk management of liquid cooling technology in IDC. Supplementary Information The online version contains supplementary material available at 10.1007/s43188-024-00234-3.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Toxicol Res Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Toxicol Res Ano de publicação: 2024 Tipo de documento: Article