Your browser doesn't support javascript.
loading
Comparative performance analysis of mussel-inspired polydopamine, polynorepinephrine, and poly-α-methyl norepinephrine in electrochemical biosensors.
Bisht, Neha; Patel, Monika; Mondal, D P; Srivastava, Avanish Kumar; Dwivedi, Neeraj; Dhand, Chetna.
Afiliação
  • Bisht N; CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India.
  • Patel M; CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India.
  • Mondal DP; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
  • Srivastava AK; CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India.
  • Dwivedi N; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
  • Dhand C; CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India.
Mikrochim Acta ; 191(8): 456, 2024 07 09.
Article em En | MEDLINE | ID: mdl-38980419
ABSTRACT
Polydopamine (PDA) has garnered significant interest for applications in biosensors, drug delivery, and tissue engineering. However, similar polycatecholamines like polynorepinephrine (PNE) with additional hydroxyl groups and poly-α-methylnorepinephrine (PAMN) with additional hydroxyl and methyl groups remain unexplored in the biosensing domain. This research introduces three innovative biosensing platforms composed of ternary nanocomposite based on reduced graphene oxide (RGO), gold nanoparticles (Au NPs), and three sister polycatecholamine compounds (PDA, PNE, and PAMN). The study compares and evaluates the performance of the three biosensing systems for the ultrasensitive detection of Mycobacterium tuberculosis (MTB). The formation of the nanocomposites was meticulously examined through UV-Visible, Raman, XRD, and FT-IR studies with FE-SEM and HR-TEM analysis. Cyclic voltammetry and differential pulse voltammetry measurements were also performed to determine the electrochemical characteristics of the modified electrodes. Electrochemical biosensing experiments reveal that the RGO-PDA-Au, RGO-PNE-Au, and RGO-PAMN-Au-based biosensors detected target DNA up to a broad detection range of 0.1 × 10-8 to 0.1 × 10-18 M, with a low detection limit (LOD) of 0.1 × 10-18, 0.1 × 10-16, and 0.1 × 10-17 M, respectively. The bioelectrodes were proved to be highly selective with excellent sensitivities of 3.62 × 10-4 mA M-1 (PDA), 7.08 × 10-4 mA M-1 (PNE), and 6.03 × 10-4 mA M-1 (PAMN). This study pioneers the exploration of two novel mussel-inspired polycatecholamines in biosensors, opening avenues for functional nanocoatings that could drive further advancements in this field.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Técnicas Biossensoriais / Nanopartículas Metálicas / Técnicas Eletroquímicas / Limite de Detecção / Ouro / Grafite / Indóis Limite: Animals Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Técnicas Biossensoriais / Nanopartículas Metálicas / Técnicas Eletroquímicas / Limite de Detecção / Ouro / Grafite / Indóis Limite: Animals Idioma: En Revista: Mikrochim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia