Your browser doesn't support javascript.
loading
On-Field Evaluation of Mouthpiece-and-Helmet-Mounted Sensor Data from Head Kinematics in Football.
Holcomb, Ty D; Marks, Madison E; Pritchard, N Stewart; Miller, Logan E; Rowson, Steve; Bullock, Garrett S; Urban, Jillian E; Stitzel, Joel D.
Afiliação
  • Holcomb TD; Department of Biomedical Engineering, Wake Forest School of Medicine, 575 Patterson Avenue, Suite 530, Winston-Salem, NC, 27101, USA.
  • Marks ME; Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Winston-Salem, NC, USA.
  • Pritchard NS; Department of Biomedical Engineering, Wake Forest School of Medicine, 575 Patterson Avenue, Suite 530, Winston-Salem, NC, 27101, USA.
  • Miller LE; Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Winston-Salem, NC, USA.
  • Rowson S; Department of Biomedical Engineering, Wake Forest School of Medicine, 575 Patterson Avenue, Suite 530, Winston-Salem, NC, 27101, USA.
  • Bullock GS; Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Winston-Salem, NC, USA.
  • Urban JE; Department of Biomedical Engineering, Wake Forest School of Medicine, 575 Patterson Avenue, Suite 530, Winston-Salem, NC, 27101, USA.
  • Stitzel JD; Virginia Tech-Wake Forest School of Biomedical Engineering and Sciences, Winston-Salem, NC, USA.
Ann Biomed Eng ; 2024 Jul 25.
Article em En | MEDLINE | ID: mdl-39058402
ABSTRACT

PURPOSE:

Wearable sensors are used to measure head impact exposure in sports. The Head Impact Telemetry (HIT) System is a helmet-mounted system that has been commonly utilized to measure head impacts in American football. Advancements in sensor technology have fueled the development of alternative sensor methods such as instrumented mouthguards. The objective of this study was to compare peak magnitude measured from high school football athletes dually instrumented with the HIT System and a mouthpiece-based sensor system.

METHODS:

Data was collected at all contact practices and competitions over a single season of spring football. Recorded events were observed and identified on video and paired using event timestamps. Paired events were further stratified by removing mouthpiece events with peak resultant linear acceleration below 10 g and events with contact to the facemask or body of athletes.

RESULTS:

A total of 133 paired events were analyzed in the results. There was a median difference (mouthpiece subtracted from HIT System) in peak resultant linear and rotational acceleration for concurrently measured events of 7.3 g and 189 rad/s2. Greater magnitude events resulted in larger kinematic differences between sensors and a Bland Altman analysis found a mean bias of 8.8 g and 104 rad/s2, respectively.

CONCLUSION:

If the mouthpiece-based sensor is considered close to truth, the results of this study are consistent with previous HIT System validation studies indicating low error on average but high scatter across individual events. Future researchers should be mindful of sensor limitations when comparing results collected using varying sensor technologies.