[Diagnostic significance of intravenous digital subtraction angiography of the supra-aortic extracranial vascular system. Comparative study of i.v. DSA and plain film angiography]. / Diagnostische Aussagekraft der intravenösen digitalen Subtraktionsangiographie des supraaortalen extrakraniellen Gefässsystems. Eine vergleichende Studie von i.v. DSA und Blattfilmangiographie.
Rofo
; 141(6): 624-8, 1984 Dec.
Article
em De
| MEDLINE
| ID: mdl-6440227
Digital intravenous subtraction angiography (DSA) and conventional film angiography were used to evaluate the diagnostic reliability of DSA-examinations. In 90% of 650 DSA-angiogramms the image quality was diagnostic. For 124 carotid angiographies a comparison of both methods was possible and gave a sensitivity of 87%, a specificity of 96% and an accuracy of 90% for the DSA examinations. The authors believe that digital subtraction angiography is suitable as a screening method for supraaortal vascular occlusive diseases.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Arteriopatias Oclusivas
/
Angiografia
/
Doenças das Artérias Carótidas
/
Ataque Isquêmico Transitório
Tipo de estudo:
Diagnostic_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
De
Revista:
Rofo
Ano de publicação:
1984
Tipo de documento:
Article