Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 18.682
Filtrar
1.
Sci Rep ; 14(1): 7724, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565922

RESUMO

Transarticular external skeletal fixation (TESF) is repeatedly used for temporary stabilisation of tarsal joint in cats. Hence, this study aimed to evaluate the use of temporary modified type II TESF for management of talocrural instability (TCI) in cats without joint arthrodesis and to rate short-term outcomes and complications. Medical records of all cats treated for TCI between January 2012 and December 2021 were reviewed. Information was collected including signalment, degree of lameness, type of TCI, accompanying soft tissue and bone injuries, and post-operative follow-up assessment including time of frame removal, complications, degree of lameness, range of joint motion and ankylosis. Surgical management didn't involve debridement of the articular cartilage. Eighty-five percent of cats had satisfactory joint stability at the time of frame removal. Eighteen cats exhibited minor complications, six cats had major complications, and 8 cats showed persistent lameness. All cats showed reduction of joint motion range by 20°-30° directly after frame removal while returned to normal in 79% of cats 4 weeks later. Variable degrees of joint ankylosis were reported. In conclusion, this study supports the use of temporary modified type II TESF for management of TCI in cats without joint involvement as an excellent alternative to tarsal arthrodesis.


Assuntos
Anquilose , Luxações Articulares , Gatos , Animais , Fixadores Externos/veterinária , Coxeadura Animal , Fixação de Fratura , Luxações Articulares/cirurgia , Anquilose/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
2.
Proc Inst Mech Eng H ; 238(4): 403-411, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38602217

RESUMO

External fixation is an essential surgical technique for treating trauma, limb lengthening and deformity correction, however infection is common, with infection rates ranging from 4.5 to 100% of cases. Throughout the literature researchers and clinicians have highlighted a relationship between excessive movement of the pin and skin and an increase in the patient's risk of infection, however, currently no studies have addressed this role of pin-movement on pin-site wounds. This preliminary study describes a novel in vitro pin-site model, developed using a full-thickness human skin equivalent (HSE) model in conjunction with a bespoke mechanical system which simulates pin-movement. The effect of pin-movement on the wound healing response of the skin equivalents was assessed by measuring the expression of pro-inflammatory cytokines. Six human skin equivalent models were divided into three test groups: no pin as the control, static pin-site wound and dynamic pin-site wound (n = 3). On day 3 concentrations of IL-1α and IL-8 showed a significant increase compared to the control when a static fixation pin was implanted into the skin equivalent (p < 0.05) and (p < 0.005) respectively. Levels of IL-1α and IL-8 increased further in the dynamic sample compared to the static sample (p < 0.05) and (p < 0.0005). This study demonstrates for the first time the application of HSE model to study external-fixation pin-movement in vitro. The results of this study demonstrated pin-movement has a negative effect on soft-tissue wound-healing, supporting the anecdotal evidence reported in the literature, however further analysis of wound heading would be required to verify this hypothesis.


Assuntos
Fixadores Externos , Fixação de Fratura , Humanos , Fixação de Fratura/métodos , Infecção da Ferida Cirúrgica/terapia , Interleucina-8 , Pinos Ortopédicos , Cicatrização/fisiologia
3.
J Orthop Surg Res ; 19(1): 231, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589910

RESUMO

BACKGROUND: Internal and external fixation are common surgical procedures for treating fractures. However, the impact of different surgical approaches (including internal and external fixations) on patients' psychological status and Quality of Life (QoL) is rarely examined. Herein, we aimed to investigate the effects of internal and external fixation on anxiety, depression, insomnia, and overall mental and physical health in Distal Radius Fractures (DRF) patients. METHODS: We performed a retrospective study on 96 fracture patients who underwent internal fixation (57 patients) or external fixation (39 patients). The Visual Analog Scale (VAS), the Hospital Anxiety and Depression Scale (HADS), the Athens Insomnia Scale (AIS), and the Medical Outcomes Study Short Form 36 (SF-36) questionnaire were used to assess the patients' pain, anxiety, depression, sleep, and QoL before surgery and at seven days, one month, and three months post-surgery. RESULTS: The VAS scores were significantly lower in the Internal Fixation Group (IFG) than in the External Fixation Group (EFG) on the seventh day and one month postoperatively (P < 0.05). Although both groups showed no significant anxiety, depression, or insomnia before surgery (P > 0.05), the EFG showed significantly higher HADS-A, HADS-D, and AIS scores than the IFG at seven days and one and three months postoperatively (P < 0.05). Additionally, changes in HADS-A, HADS-D, and AIS scores were most significant at day seven post-surgery in the EFG (P < 0.05). Furthermore, no significant difference was found between the two groups in the average Physical Component Summary (PCS) and Mental Component Summary (MCS) scores before surgery (P > 0.05). However, both groups showed positive changes in PCS and MCS scores at postoperative day seven and one and three months postoperatively, with the IFG having significantly higher average PCS and MCS scores compared to the EFG (P < 0.05). CONCLUSION: Compared to external fixation, internal fixation did not significantly impact patients' emotions regarding anxiety and depression in the early postoperative period, and physical and mental health recovery was better during the postoperative rehabilitation period. Furthermore, when there are no absolute indications, the impact on patients' psychological well-being should be considered as one of the key factors in the treatment plan during surgical approach selection.


Assuntos
Fraturas Ósseas , Distúrbios do Início e da Manutenção do Sono , Humanos , Qualidade de Vida , Distúrbios do Início e da Manutenção do Sono/etiologia , Fixadores Externos , Estudos Retrospectivos , Fixação de Fratura/efeitos adversos , Fixação Interna de Fraturas/efeitos adversos , Fenômenos Físicos
4.
J Pak Med Assoc ; 74(3): 440-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38591274

RESUMO

Objective: To determine the combined column tibial plateau fracture treated with a hybrid external fixator in terms of knee functionality, union outcome and complications. METHODS: The quasi-experimental study was conducted at the Department of Orthopaedic Surgery, Mayo Hospital, Lahore, Pakistan, from July 5, 2019, to December 31, 2021, and comprised patients of either gender aged 20-50 years who presented with 2-column or 3-column fractures of proximal tibia classified according to the 3-column classification system after being diagnosed using radiographs and three-dimensional computed tomography scan. Knee function, union and complications, like neural, vascular, infection, delayed union, nonunion, malunion and implant failure, were evaluated. The Knee Society Score was used to assess knee function, and modified Rasmussen score for the union, while complications were assessed clinically on the 2nd, 6th, 12th, 16th, 24th, 36th weeks and one year post-operatively. Data was analysed using SPSS 26. RESULTS: Of the 113 patients, 91(80.53%) were males and 22(19.47%) were females. The overall mean age was 35.56±9.00 years. From the 12th week to the 24th week 45(39.83%) patients had good and 59(52.21%) patients had excellent functional outcomes. Union outcome in the 16th and 24th week was good in 57(50.44%) patients and excellent in 47(41.59%) patients. No neurovascular injury was observed. Superficial pin tract infection was observed in 21(18.6%) cases that healed with wound debridement and antibiotics. No delayed union, malunion and implant failure was observed. CONCLUSIONS: Good to excellent functional and union outcomes with minimum complications were observed with the hybrid external fixator.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Masculino , Feminino , Humanos , Adulto , Resultado do Tratamento , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixadores Externos , Fixação de Fratura/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
5.
BMC Musculoskelet Disord ; 25(1): 284, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609889

RESUMO

BACKGROUND: The purpose of the study was to assess and compare the clinical efficacy of bone transport with either circular or unilateral external fixators over an intramedullary nail in the treatment of tibial bone defects caused by infection. METHODS: Between May 2010 and January 2019, clinical and radiographic data were collected and analyzed for patients with bone defects caused by infection. Thirteen patients underwent bone transport using a unilateral external fixator over an intramedullary nail (Group A), while 12 patients were treated with a circular external fixator over an intramedullary nail (Group B). The bone and functional outcomes of both groups were assessed and compared using the Association for the Study and Application of the Method of the Ilizarov criteria, and postoperative complications were evaluated according to the Paley classification. RESULTS: A total of 25 patients were successfully treated with bone transport using external fixators over an intramedullary nail, with a mean follow-up time of 31.63 ± 5.88 months. There were no significant statistical differences in age, gender, previous surgery per patient, duration of infection, defect size, and follow-up time between Group A and Group B (P > 0.05). However, statistically significant differences were observed in operation time (187.13 ± 21.88 min vs. 255.76 ± 36.42 min, P = 0.002), intraoperative blood loss (39.26 ± 7.33 mL vs. 53.74 ± 10.69 mL, P < 0.001), external fixation time (2.02 ± 0.31 month vs. 2.57 ± 0.38 month, P = 0.045), external fixation index (0.27 ± 0.08 month/cm vs. 0.44 ± 0.09 month/cm, P = 0.042), and bone union time (8.37 ± 2.30 month vs. 9.07 ± 3.12, P = 0.032) between Group A and Group B. The excellent and good rate of bone and functional results were higher in Group A compared to Group B (76.9% vs. 75% and 84.6% vs. 58.3%). Statistically significant differences were observed in functional results (excellent/good/fair/poor, 5/6/2/0 vs. 2/5/4/1, P = 0.013) and complication per patient (0.38 vs. 1.16, P = 0.012) between Group A and Group B. CONCLUSIONS: Bone transport using a combined technique of external fixators over an intramedullary nail proved to be an effective method in treating tibial bone defects caused by infection. In comparison to circular external fixators, bone transport utilizing a unilateral external fixator over an intramedullary nail resulted in less external fixation time, fewer complications, and better functional outcomes.


Assuntos
Fixadores Externos , Osteopatia , Humanos , Estudos Retrospectivos , Fixação de Fratura , Fixadores Internos
7.
Artigo em Inglês | MEDLINE | ID: mdl-38537115

RESUMO

INTRODUCTION: External fixation of unstable ankle injuries is commonly done by orthopaedic surgeons. An improper technique can negate the benefits of the procedure and necessitate revision. This study sought to determine the risk factors for revision of external fixation of unstable ankle injuries. METHODS: Retrospective cohort at a level I academic trauma center of 120 consecutive patients underwent external fixation of an unstable ankle injury. Exclusion criteria included external fixation for reason other than fracture, inadequate intraoperative imaging, skeletal immaturity, and follow-up less than 30 days. Primary outcome measurement was revision of external fixation within 30 days. RESULTS: Ninety-seven patients met inclusion criteria. Eighteen (18.6%) underwent revision within 30 days of whom 5 (28%, P < 0.001) had a poor reduction intraoperatively. No patients with a good reduction required revision. Revised patients had a significantly higher talar tilt (P < 0.001) and were more likely to lack a first metatarsal pin (P = 0.018). Multivariate analysis revealed talar tilt >0.5° (odds ratio, 22.62; 95% confidence interval, 6.52 to 50.63) as an independent risk factor for revision. DISCUSSION: For external fixation of unstable ankle injuries, poor reduction quality is a risk factor for need for revision surgery. Orthopaedic surgeons should be critical of their final intraoperative assessment to prevent revision.


Assuntos
Traumatismos do Tornozelo , Fixação de Fratura , Humanos , Estudos Retrospectivos , Fixação de Fratura/métodos , Fixadores Externos , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fatores de Risco
8.
J Mech Behav Biomed Mater ; 153: 106488, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38437754

RESUMO

INTRODUCTION: This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS: A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS: Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION: An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Fenômenos Biomecânicos , Fixadores Externos , Fixação de Fratura/métodos , Ossos Pélvicos/cirurgia
9.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484095

RESUMO

CASE: A 23-year-old right-hand dominant man presented with a high-velocity gunshot wound injury to the right thumb with severe soft-tissue damage, vascular injury, and large osseous defect of the right thumb metacarpal. The patient was successfully treated with metacarpophalangeal joint arthrodesis and metacarpal reconstruction using definitive external fixation, an intramedullary Kirschner wire, and use of the Masquelet bone grafting technique. CONCLUSION: The authors' treatment approach for a mangled thumb injury with definitive external fixation and utilization of the Masquelet technique resulted in restoration of a large osseous defect, avoidance of infection, and limited loss of mobility.


Assuntos
Traumatismos da Mão , Procedimentos de Cirurgia Plástica , Ferimentos por Arma de Fogo , Humanos , Masculino , Adulto Jovem , Fixadores Externos , Fixação de Fratura/métodos , Traumatismos da Mão/cirurgia , Polegar/cirurgia , Ferimentos por Arma de Fogo/cirurgia
10.
Med Sci Monit ; 30: e944136, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38549240

RESUMO

BACKGROUND Tibial fractures, common in adults, are often treated with external or internal fixation methods. While effective, external fixation (EF) can lead to sexual dysfunction (SD), especially in young patients. This study aimed to assess SD in women undergoing EF versus internal fixation for tibial fractures. MATERIAL AND METHODS Sexual function and frequency of monthly sexual intercourse (SI) were evaluated using the Female Sexual Function Index (FSFI) before surgery, with the fixator, after at least 6 months following fixator removal in EF group, and after achieving bone union for at least 3 months in the IF group. RESULTS The EF group consisted of 107 (mean age 28.5 years; 19-40 years) and IF group consisted of 106 patients (mean age 32.1 years; 18-40 years). The duration of EF was an average of 4.7 months (range, 2.5-13 months). FSFI scores were significantly lower in the EF group compared to the IF group (9.33 versus 27.3, P<0.001). Also, there was no significant difference between the FSFI scores before EF and after EF was removed (34.22 versus 33.8, P=0.413). FSFI sub-group scores such as desire, arousal, lubrication, and orgasm were significantly lower in the EF group (P<0.001). The monthly average frequency of SI before surgery and after the removal of EF was 10.2 and 9.1, respectively, while this frequency was 2.56 when EF was present (P<0.001). CONCLUSIONS The quality and frequency of SI in women significantly deteriorate and decrease during the period of extremity fixation following tibial diaphyseal fractures treated with EF, but return to normal after removal.


Assuntos
Disfunções Sexuais Fisiológicas , Fraturas da Tíbia , Adulto , Humanos , Feminino , Estudos Retrospectivos , Fixadores Externos , Fraturas da Tíbia/complicações , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Fixação de Fratura/métodos , Resultado do Tratamento
12.
J Plast Reconstr Aesthet Surg ; 91: 276-283, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432085

RESUMO

BACKGROUND: The study aims to assess the safety and effectiveness of BoneTape™, a new resorbable bone fixation device, using a zygomatic fracture model in rabbits. METHODS: The study followed BoneTape™ samples and control (sham) groups over 2-, 6-, and 12-week periods post-zygomaticomaxillary (ZM) osteotomy and zygomaticofrontal (ZF) disarticulation. The osteotomized segments were analyzed for bone healing, inflammatory response, and tissue healing. µCT imaging and histological analysis were used to examine the axial alignment, offset, and quality of new bone formation. RESULTS: BoneTape™ samples demonstrated enhanced maintenance of the initial intraoperative positioning, reduced axial offset, and better alignment when compared with the control group, enabling stable bone healing under physiological loading conditions. Complete union was observed at 12-weeks in both groups. The BoneTape™ group experienced minimal immune and tissue reactions, classically associated with wound healing, and showed an increased number of giant cells at 6 and 12-weeks. CONCLUSION: BoneTape™ represents a promising advancement in osteosynthesis, demonstrating efficacy in maintaining stable zygomatic reconstruction and eliciting minimal immune response in a rabbit model. This study introduces BoneTape™ as a disruptive solution specifically designed for clinical application in cranio-maxillofacial fracture fixation, with the potential to eliminate the use of over-engineered solutions while offering benefits such as ease of application and fewer biologically disruptive steps.


Assuntos
Fraturas Cranianas , Fraturas Zigomáticas , Animais , Coelhos , Fraturas Zigomáticas/diagnóstico por imagem , Fraturas Zigomáticas/cirurgia , Fixadores Internos , Fixação Interna de Fraturas/métodos , Fraturas Cranianas/diagnóstico por imagem , Fraturas Cranianas/cirurgia , Fixação de Fratura , Placas Ósseas
13.
Proc Inst Mech Eng H ; 238(2): 187-197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38314816

RESUMO

This paper presents the outcome of a data review of patients treated with the IOS external fixation system at the Royal Stoke University Hospital: a fixation designed to meet four requirements for external fixation proposed in this paper. Demographic data and outcome were collected and assessed. From 69 initial patients, 64 patients (55 males and 9 females) had an average age of 35.9 years. The mean time to union was 127 days. There were no incidences of malunion, or refracture post fixation removal attributable to the treatment method. In addition, in this cohort, there was no incidence of pin tract infection resulting in osteomyelitis. Of all the factors assessed the only factor to have any significant effect on healing was smoking: an average delay of 31 days. An examination of RUST (radiographic union score tibia) and modified RUST scores illustrated a potential false negative of up to 80%. Hence, this study cannot support the use of either scoring system to diagnose fracture healing. IOS external fixation was shown to be an effective method for the treatment of unstable tibial fractures. The reduction at fixation removal was shown to be very good. There was no incidence of osteomyelitis. It is, therefore, suggested that appropriately used external fixation is a viable alternative to intramedullary nailing if designed and surgically applied using four design principles outlined in this paper. Furthermore, it is proposed that external fixation be designed and applied to meet these four principles.


Assuntos
Fixação Intramedular de Fraturas , Osteomielite , Fraturas da Tíbia , Masculino , Feminino , Humanos , Adulto , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tíbia , Fixação de Fratura/métodos , Consolidação da Fratura , Osteomielite/etiologia , Resultado do Tratamento , Fixadores Externos
15.
J Hand Surg Eur Vol ; 49(2): 215-225, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38315130

RESUMO

Distal radial fractures represent the most common fractures of the upper extremity. Operative treatment is performed for approximately one-third of distal radial fractures in the adult population. Complications following operative treatment of distal radial fractures vary depending on the treatment modality and can be stratified into preoperative and postoperative complications. Complications can occur in the near, intermediate and long term. The most common complications seen are tendon irritation and rupture, chronic regional pain syndrome (CRPS), carpal tunnel syndrome, ulnar or radial neuropathy, compartment syndrome, malunion, inadequate fixation or loss of fixation, symptomatic hardware, post-traumatic arthritis, stiffness and infection. Careful planning, treatment and patient selection can help to mitigate these complications.Level of evidence: V.


Assuntos
Síndrome do Túnel Carpal , Fraturas do Rádio , Adulto , Humanos , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Rádio/terapia , Síndrome do Túnel Carpal/cirurgia , Síndrome do Túnel Carpal/complicações , Fixação de Fratura , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Resultado do Tratamento , Placas Ósseas/efeitos adversos
16.
J Craniomaxillofac Surg ; 52(3): 279-282, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38320919

RESUMO

This retrospective analysis aimed to investigate the necessity of removing the wisdom tooth in cases of angle fractures of the mandible. The study retrieved 595 mandible fractures from January 2006 to December 2021 through the Hospital Inpatient Enquiry System, of which 303 involved a fracture through the angle of the mandible, including the wisdom tooth socket. Of these, 203 (66.9%) underwent open reduction and internal fixation with retention of the third molar. The authors found that only four (2%) patients returned for the removal of plates and the retained third molar during the follow-up period. Therefore, the authors concluded that wisdom teeth removal should remain an exception during open reduction and internal fixation of mandibular angle fractures unless they hinder fracture reduction, pose a potential infection risk, or interfere with occlusal stability.


Assuntos
Fraturas Mandibulares , Dente Impactado , Humanos , Fraturas Mandibulares/cirurgia , Dente Serotino/cirurgia , Estudos Retrospectivos , Mandíbula/cirurgia , Fixação de Fratura , Extração Dentária , Dente Impactado/cirurgia
17.
Injury ; 55(4): 111385, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38359710

RESUMO

Pilon fractures represent a challenging subset of tibial fractures. The management of AO/OTA Type C3 fractures remains complex due to associated complications and lack of clear guidelines for surgical timing and methods. A prospective cohort study was conducted to evaluate two staged treatment strategies for AO/OTA Type C3 tibial pilon fractures. The study focused on assessing surgical difficulty, complications, and patient prognosis. One group of patients received early internal fixation of the fibula and tibial posterior column combined with external fixation, while the other group received external fixation alone in the first stage. Patients who received early internal fixation of the fibula and tibial posterior column combined with external fixation had better outcomes, including lower rate of allogeneic bone grafting (67.74 % versus 94.64 %), reduced incidence of wound delay and skin necrosis (3.23 % versus 21.43 %), shorter surgical time (133.06 ± 23.99 min versus 163.04 ± 26.83 min), shorter hospital stay (13.77 ± 2.53 days versus 18.25 ± 3.67 days), and higher AOFAS (83.05 ± 8.68 versus 79.36 ± 8.92). Additionally, avoiding fibular shortening was shown to be crucial in preventing prolonged surgery and improving patient function. The study demonstrated that the staged treatment approach with early internal fixation led to shorter operative times, improved ankle function, and reduced complications, including a lower risk of infection. The findings support the use of this treatment to optimize outcomes in AO/OTA Type C3 pilon fractures.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Fraturas da Tíbia , Humanos , Estudos Prospectivos , Resultado do Tratamento , Traumatismos do Tornozelo/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Estudos Retrospectivos , Fixação de Fratura
18.
Injury ; 55(4): 111391, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38377672

RESUMO

OBJECTIVE: To analyze the application value of damage control strategies combining pre-hospital emergency treatment with in-hospital treatment for multiple injuries in treating pelvic fracture complicated by multiple injuries. METHODS: 120 patients with pelvic fracture complicated by multiple injuries admitted to our hospital from January 2020 to January 2023 were selected and divided into a damage control group (early temporary reduction after resuscitation, n = 60) and a control group (no reduction and resuscitation only, n = 60) by treatment methods. The control group was treated with conventional methods, while the damage control group was treated with the damage control strategy combining pre-hospital emergency treatment combined with in-hospital treatment in addition to conventional methods. The mortality rate, complication rate, fracture reduction quality, long-term efficacy, and patient satisfaction of the two groups were compared. RESULTS: The mortality rate of the damage control group was lower than that of the control group, and the difference has statistical significance (P<0.05); the incidence of infection, DIC, and MODS of the damage control group were lower than that of the control group, with the difference being statistically significant (P<0.05); the incidence of ARDS in the two groups is not that different (P>0.05); the fracture reduction quality and long-term therapeutic effect of patients in the two groups were statistically different, with the damage control group outperforming the control group in both aspects; the difference between the two groups in terms of patient satisfaction was statistically significant (P<0.05), with the patient satisfaction of the damage control group being higher than that of the control group. CONCLUSION: For patients with pelvic fracture, the application of the damage control strategy combining pre-hospital emergency treatment and in-hospital treatment is a boon to the standardization of the treatment process, the improvement of the treatment success rate and fracture reduction quality and the reduction of complications, and therefore is worth promoting in clinical practice. the early application of external fixation has helped with the definitive reduction at a time when the patuent was stable.


Assuntos
Fraturas Ósseas , Traumatismo Múltiplo , Ossos Pélvicos , Humanos , Fraturas Ósseas/terapia , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões , Fixação de Fratura/métodos , Resultado do Tratamento , Hospitais , Traumatismo Múltiplo/terapia , Traumatismo Múltiplo/cirurgia , Estudos Retrospectivos , Fixação Interna de Fraturas
19.
Injury ; 55(3): 111349, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38277877

RESUMO

PURPOSE: Sierra Leone is a low-income country located on the west coast of Africa where the majority of the population does not have free access to emergency medical and surgical services, the principal cause of open tibia fractures is motorcycle collision. Open fractures of the middle and distal third of the tibial segments, particularly those classified as type III B, represent a challenge for orthopedic surgeons because of the loss of soft tissue coverage. The Reverse Sural Fasciocutaneous Flap (RSFF) has been shown to be an ideal and reproducible option for the treatment of soft tissue defects. The main aim of this study was to demonstrate the experience in Resource Limited Settings (RLS) by means of a short series of the efficacy of using a combination of external fixation and RSFF in the treatment of grade III B open tibia fractures where plastic surgeons were not available. METHODS: This retrospective, descriptive, and non-experimental study included 8 patients who underwent surgical intervention between September 2020 and September 2021. RESULTS: The skin defects were of various sizes; the smallest size was 4 × 7 cm, and the biggest size of 12 × 18 cm. We obtained a success rate in seven of the eight cases. CONCLUSIONS: External fixation and reverse sural fasciocutaneous sural flap are excellent therapeutic options for the treatment of open grade III B diaphyseal and metaphyseal distal tibial fractures.


Assuntos
Fraturas Expostas , Procedimentos de Cirurgia Plástica , Lesões dos Tecidos Moles , Fraturas da Tíbia , Humanos , Região de Recursos Limitados , Fixadores Externos , Estudos Retrospectivos , Fixação de Fratura , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Fraturas Expostas/cirurgia , Lesões dos Tecidos Moles/cirurgia
20.
World Neurosurg ; 184: 112-118, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38266989

RESUMO

BACKGROUND: Combined triple atlas (C1)-axis (C2) fixation has been described in previous literature as a safe, effective, and minimally invasive procedure for complex atlas and odontoid fractures that allows for a greater range of motion compared with posterior approaches and atlanto-occipital fusion. However, it is rarely performed due to the occipital-cervical diastasis resulting from often-fractured C1 joint masses. No evidence-based consensus has been reached regarding the treatment of complex atlantoaxial fractures, and the choice of surgical strategy is based only on clinical experience. METHODS: We report the combined triple C1-C2 fixation technique with manual reduction of the joint masses during patient positioning on the operating table, which allowed for effective stabilization during a single surgical session. We describe our experience in the management of a 75-year-old patient presenting with an acute complex type II fracture of C1, which also involved 1 lateral mass, combined with a type II odontoid fracture and occipital-cervical diastasis. RESULTS: We provide a step-by-step guide for combined triple C1-C2 anterior fixation with manual fracture reduction and describe the clinical case of an acute complex type II fracture of C1, which also involved 1 lateral mass, combined with a type II odontoid fracture and occipital-cervical diastasis. CONCLUSIONS: Combined triple C1-C2 fixation represents a safe and efficient minimally invasive anterior approach for complex type II fractures of C1 with type II odontoid fractures. Manual reduction of the joint masses during patient positioning allows for effective stabilization in a single surgical session.


Assuntos
Fraturas Ósseas , Lesões do Pescoço , Processo Odontoide , Fraturas da Coluna Vertebral , Humanos , Idoso , Processo Odontoide/diagnóstico por imagem , Processo Odontoide/cirurgia , Processo Odontoide/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Parafusos Ósseos , Fixação de Fratura , Fixação Interna de Fraturas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...