Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.407
Filtrar
1.
BMC Oral Health ; 24(1): 416, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580975

RESUMO

OBJECTIVE: To investigate the status and related factors of sterilizers in dental health-care settings in Yunnan Province, with the aim of providing a theoretical basis for the health administrative department to formulate regional quality control programs and systems, proposing reasonable suggestions for optimizing the allocation of sterilizer resources in Yunnan's dental health-care settings, thereby improving resource utilization efficiency. METHODS: This cross-sectional survey was conducted in 2600 dental health-care settings in Yunnan Province in March 2020. Uni-variable linear regression, multi-variable linear regression, curve fitting and threshold effect analysis were used to understand the relationship between dental units and sterilizers. RESULTS: A total of 2600 dental health-care settings were included. The disinfection and sterilization work were mainly completed by the dental department in 1510(58.1%) institutions. 44(1.7%) institutions were not allocated sterilization equipment, and 1632 (62.8%) had only one sterilizer. The median allocation of sterilizers was 1.0. Uni-variable linear regression showed significant differences in covariates such as dental unit, dental handpiece, disinfection equipment, dentist, and dental assistant, which were more sensitive (p < 0.001) and statistically significant. The adjusted model was more stable in the multi-variable linear regression, and the differences in covariates between different settings were statistically significant. Curve fitting revealed an S-shaped curvilinear relationship between the number of dental units and sterilizers in oral healthcare settings. CONCLUSION: The disinfection and sterilization work was mainly completed by the dental department in dental health-care settings in Yunnan Province. Sterilizer allocation increases with the number of dental units, but some institutions have insufficient allocation of sterilizer and manpower resources, resulting in certain risks of infection control. Thus, it is necessary to strengthen supervision, inspection and regional quality control work in infection control of dentistry.


Assuntos
Desinfecção , Controle de Infecções , Humanos , Estudos Transversais , China , Instrumentos Odontológicos
2.
Shanghai Kou Qiang Yi Xue ; 33(1): 54-58, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38583025

RESUMO

PURPOSE: To compare the forming ability of four kinds of nickel-titanium instrument preparation resin for simulated curved root canal. METHODS: A total of 40 single bend resin simulated root canals were randomly divided into 4 groups with 10 in each group. Four kinds of nickel-titanium instruments (ProTaper, HyFlex EDM, WaveOne Gold and Reciproc Blue) were used for root canal preparation, and divided into group A, group B, group C and group D. The preparation time of the four groups was compared, the root canal images before and after preparation were analyzed by computer image analysis software, and the changes of the preparation time, curvature and curvature radius of the four groups were recorded. With the root tip as the center of the circle, the radius of 1-10 mm was selected as concentric circle arcs. The detection points were overlapping root canal intersection points. The resin removal amount and center positioning force of the inner and outer walls of the root canal at different detection points were recorded. Statistical analysis was performed with SPSS 20.0 software package. RESULTS: The root canal preparation time in group A was significant longer than that in group B, C and D(P<0.05), but there was no significant difference in the curvature and curvature radius of the root canal among the four groups (P>0.05). The removal amount of resin from the root canal wall in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 8, 9 and 10 mm, respectively. The removal amount of resin from the outer wall of the root canal in group C was significant lower than that in group A, B and D (P<0.05) when the distance from the detection point to the apical foramina was 5, 6, 7, 9 and 10 mm, respectively. The root tip offset of group A from the detection point to the apical hole of 1, 2, 3, 4, 6, 7, 8, 9 and 10 mm was significant greater than that of group B, C and D(P<0.05). CONCLUSIONS: Among the four instruments, ProTaper has the largest apical deviation, HyFlex EDM, WaveOne Gold and Reciproc Blue have better ability of root canal forming.


Assuntos
Cavidade Pulpar , Titânio , Níquel , Instrumentos Odontológicos , Preparo de Canal Radicular/métodos , Desenho de Equipamento
3.
São Paulo; s.n; 20240222. 152 p.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1531900

RESUMO

Introdução: Mucosite oral é um efeito colateral dos tratamentos oncológicos, caracterizado por lesões orais que vão de eritema a úlceras que podem causar dor intensa e restrição de dieta. É conhecida como condição limitante e de grande impacto na qualidade de vida (QV). Objetivo: Elaborar um novo instrumento para avaliar a QV relacionada à mucosite oral. Material e método: Pesquisa através de métodos mistos, iniciando com entrevistas qualitativas analisadas pelo método de Bardin e método Reinert, com o programa IRAMUTEQ, seguido do método Delphi com quatro rodas de entrevistas e discussões com especialistas. A primeira versão do instrumento passou por um pré-teste com 10 pacientes, com análise quantitativa e qualitativa, seguido de outra rodada de especialistas. Resultados: O material das entrevistas qualitativas apontou os termos dor e alimentação como centrais na experiência de mucosite oral, além de fornecerem várias palavras-chave para definição dos constructos. Baseado nesse material e na literatura, 4 especialistas formularam 34 perguntas enviadas para outros 10 especialistas de diferentes regiões e instituições brasileiras que analisaram a clareza, ortografia e necessidade de cada pergunta para o questionário. As alterações pertinentes foram realizadas, revisadas e novamente discutidas. A primeira versão foi apresentada a 10 pacientes que não participaram das entrevistas qualitativas e responderam o grau de entendimento e necessidade de cada pergunta. A análise final do pré-teste reformulou alguns tempos verbais e palavras de difícil compreensão, dando forma a versão final do instrumento. Discussão: Embora existam bons instrumentos para mensurar QV e mucosite oral, apresentamos novas questões sobre impactos financeiros, interrupção de tratamento, alteração de saliva, perda de peso relacionada diretamente com a mucosite oral e aspectos psicossociais. Conclusão: Foi elaborado um novo instrumento para mensurar os impactos mucosite oral em pacientes oncológicos.


Assuntos
Qualidade de Vida , Estomatite , Inquéritos e Questionários , Instrumentos Odontológicos
4.
J Endod ; 50(4): 520-526, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38311116

RESUMO

INTRODUCTION: This study aimed to evaluate the effects from the memory-triple (MT) heat treatment on the fatigue resistance of the Reciproc by comparison with the file systems of same geometry. METHODS: Reciproc files subjected to MT heat treatment technology were designated as Group RMT and were compared with the original Reciproc (Group REC) and Reciproc Blue (Group REB). Each NiTi file from 3 groups (n = 15) was operated reciprocally with a repetitive up-and-down movement in the curved canal with 4 mm of pecking distance inside of the simulated canal at body temperature. When each file fractured, the time until fracture was recorded. The length of the fractured fragment was measured. Fractured fragments were observed under scanning electron microscope (SEM) to evaluate the topographic features of the surface. Differential scanning calorimetry (DSC) analysis was performed to estimate phase transformation temperatures. One-way analysis of variance and Duncan post hoc comparison were applied to compare among the groups at a significance level of 95%. RESULTS: RMT showed significantly higher fracture resistance (P < .05), whereas there was no difference in fatigue resistance between REC and REB. SEM examination showed the files from the 3 groups had similar topographic features. RMT showed a peak of austenite peak (Ap) at a temperature (52°C) higher than body temperature, whereas REC and REB showed Ap at 37 and 32°C, respectively. CONCLUSIONS: Under the condition of this study, the new heat treatment technique of MT technology could enhance the fatigue fracture resistance of the reciprocating files made of M-wire and Blue-wire.


Assuntos
Temperatura Alta , Preparo de Canal Radicular , Falha de Equipamento , Estresse Mecânico , Instrumentos Odontológicos , Teste de Materiais , Desenho de Equipamento , Titânio
5.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
6.
Eur Endod J ; 9(2): 133 - 138, 2024 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-38268112

RESUMO

OBJECTIVE: To evaluate the impact of different file access angles and root canal curvature's location on the fatigue failure of One Curve (OC) and E3 Azure (EZ) NiTi files using a dynamic model at simulated body temperature. METHODS: Eighty new instruments with similar tip sizes and taper (#25/0.06) from two NiTi rotary systems, One Curve and E3 Azure, were tested at simulated body temperatures (37°C) using a custom-made dynamic cyclic fatigue device. Instruments were divided into four subgroups according to the location of root canal curvature (a coronal curve 5 mm from the root canal orifice and an apical curve 10 mm from the root canal orifice) and the angle of file access (0° or 30°). Instruments were operated in simulated stainless-steel canals having a 60° curve and a 3 mm radius. A custom-made device produced controlled vertical pecks during file rotation. Time to failure (sec) was registered, and the length of the fragment segments was measured (mm). Data were analysed statistically with One-Way ANOVA and Tukey post hoc tests. The significance level was set at 5%. All separated instruments were examined by scanning electron microscope. RESULTS: One-way ANOVA (p<0.05) found a significant difference among the tested instruments. Post Hoc analysis revealed lower cyclic fatigue resistance when the angle of file access was 30º, and the root canal curvature was located coronally for both files (p<0.0001). Three-way ANOVA showed that the angle of file access was the most influential contributor to cyclic fatigue, followed by the location of file curvature and, finally, the file type (p<0.0001). The fractographic examination revealed a predominantly ductile fracture mode for all tested instruments. The lengths of all fractured segments showed no significant difference (p>0.05), indicating an accurate trajectory during testing. CONCLUSION: OC files had superior cyclic fatigue resistance than EZ files; coronal curvatures negatively impacted cyclic fatigue resistance compared to apical curvatures, while the angle of file access presented the highest impact on dynamic cyclic fatigue.


Assuntos
Ligas , Ligas Dentárias , Instrumentos Odontológicos , Níquel , Titânio , Falha de Equipamento , Preparo de Canal Radicular
7.
J Endod ; 50(2): 213-219, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37924940

RESUMO

INTRODUCTION: The aim of this study was to evaluate the torsional resistance, cyclic fatigue resistance, and bending stiffness of nickel-titanium (NiTi) file systems with different heat treatments and cross-sectional designs. METHODS: WaveOne Primary treated with memory-triple (MT) heat treatment (WOMT) was compared with WaveOne Primary (WO) and WaveOne Gold Primary (WOG). Torsional resistance test was performed using a customized device, and the distortion angle, ultimate strength, and toughness were evaluated. For cyclic fatigue resistance test, the instruments were reciprocated with continuous 4 mm up-and-down movement until fracture in a customized device, and the time to fracture was compared. Fracture surfaces of each group were examined under the scanning electron microscope. Bending stiffness was measured using a custom-made device. The results were analyzed using one-way analysis of variance and the Tukey's post hoc comparison at a significance level of 95%. RESULTS: WOMT showed higher ultimate strength and toughness than the other systems (P < .05). WOMT also showed highest cyclic fatigue resistance among the tested groups (P < .05). WO had the highest bending stiffness than others, whereas WOMT had a larger residual angle than others (P < .05). CONCLUSIONS: This new MT heat treatment technique makes NiTi file more flexible and improves its mechanical properties. In addition, the effect of heat treatment on flexibility was found to be more significant than that of the cross-sectional area.


Assuntos
Ligas , Temperatura Alta , Titânio , Níquel , Instrumentos Odontológicos , Desenho de Equipamento , Preparo de Canal Radicular , Estresse Mecânico , Teste de Materiais , Torção Mecânica
9.
Int Endod J ; 57(1): 100-107, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37886883

RESUMO

AIM: This study compared intracanal removal of filling as well as the frequency and volume of extruded material after retreatment with either HyFlex or Reciproc instruments in mandibular teeth from cadavers. METHODOLOGY: The root canals of 14 pairs of contralateral single-rooted teeth in mandibles of cadavers were instrumented with Reciproc R40 and filled using lateral compaction. The mandibles were scanned in a micro-computed tomographic (micro-CT) device before and after retreatment procedures. The contralateral teeth were assigned to two groups (n = 14) according to the retreatment protocol using either HyFlex or Reciproc instrument systems. In the HyFlex group, the HyFlex Remover instrument was worked 3 mm short of the working length (WL), followed by HyFlex CM 40.04 and 50.04 at the WL. In the Reciproc group, the R50 instrument was worked up at the coronal two thirds, followed by two more cycles until the WL was reached. Pre- and post-operative micro-CT images were analysed for extrusion and intracanal removal of filling material. RESULTS: After retreatment, extrusion of filling material occurred in 11 (78%) and 14 (100%) teeth from HyFlex and Reciproc groups respectively (p > .05). A similar volume of extruded material was observed after retreatment with both systems (p > .05). A significant decrease in the intracanal filling volume was verified after retreatment with both tested systems (p < .05). However, residual filling material was found in all root canals, regardless of the system. The amount of filling material removed (HyFlex = 80.8%; Reciproc = 65.9%) and the operation time was similar between systems (p > .05). CONCLUSIONS: A high frequency of filling material extrusion was observed after retreatment with the two systems in a cadaver model, with no significant difference between them. Both protocols obtained similar efficacy in filling material removal procedures, although none completely cleaned the canals.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Guta-Percha , Obturação do Canal Radicular , Preparo de Canal Radicular , Instrumentos Odontológicos , Retratamento , Microtomografia por Raio-X/métodos , Cavidade Pulpar
10.
Artigo em Inglês | MEDLINE | ID: mdl-38082736

RESUMO

Dentistry is an essential practice to maintain the health of the oral cavity. Recent advances in digitization and technology for oral examinations have improved the speed and ease of disease diagnosis and dental treatment. Dental robotics has emerged as a new field of dentistry and offers numerous benefits to dental professionals and society. This paper proposes an innovative design of a dental robot setup with a preliminary study on a head model for the preparation of automated dental exploration in MATLAB and discusses further considerations for automation.


Assuntos
Robótica , Humanos , Automação , Instrumentos Odontológicos , Assistência Odontológica
11.
J Contemp Dent Pract ; 24(5): 337-341, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38149812

RESUMO

AIM: This in vitro study aimed to compare and evaluate the resistance to cyclic fatigue of a newly developed glide path file in a simulated double curvature canal in a cyclic fatigue-testing machine. METHODS: In this in vitro study, a static cyclic fatigue-testing machine with a simulated double curve was created and the samples were divided into the following three groups: Group I-HyFlex EDM; group II-TruNatomy file; and group III-Aurum G files and each instrument is continued to rotate in the canal and a number of cycles to failure (NCF) was calculated and Fractographic analysis was done using scanning electron microscope (SEM), and the results were statistically analyzed. RESULTS: Statistical analysis was done using parametric methods one-way analysis of variance (ANOVA) shows statistical significance between groups and then Tukey's HSD post hoc tests were used for multiple pairwise comparisons. TruNatomy glide path files had the highest cyclic fatigue resistance when compared to HyFlex EDM and Aurum G files. CONCLUSION: The selection of file systems in cleaning and shaping protocols is an enigma to endodontics. From the results of this study, it can be concluded that TruNatomy files had higher cyclic fatigue resistance than other glide path files are canals with double curvature, hence it is suitable for usage in root canals with extreme curvature. CLINICAL SIGNIFICANCE: The selection of file systems in cleaning and shaping protocols is an enigma to endodontics. This in vitro study explored the selection protocols for the execution of root canal preparation. Heat treatment of nickel-titanium (NiTi) endodontic files had improved the cyclic fatigue resistance significantly enhancing the clinical life of file systems.


Assuntos
Projetos de Pesquisa , Titânio , Preparo de Canal Radicular , Instrumentos Odontológicos , Falha de Equipamento
13.
J Contemp Dent Pract ; 24(9): 715-721, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38152947

RESUMO

AIM: This research was carried out with the objective of comparison between GenEndo, Protaper Gold, Hero Gold and EdgeFile X3 regarding the effect of different concentrations of NaOCl. MATERIALS AND METHODS: About 720 study specimens were included in the study. They were divided into four groups. Each group consisted of 180 files. Group A: GenEndo, Group B: Protaper Gold, Group C: Hero Gold, Group D: EdgeFile X3. Each group of instruments were further subdivided into nine subgroups (n = 20 for each subgroup). Testing of the cyclic fatigue was carried out in artificial canals which were prepared inside the blocks of stainless steel. The stainless steel blocks with artificial canals were established in a receiver that was packed with experimental solutions like distilled water, 5.25% NaOCl and 2.5% NaOCl. The adjustment of temperature was done at 25, 37, and 60°C. The rotation of the instrument was carried out inside the artificial canal as per the instructions of the manufacturer. The instrument was rotated until it got fractured. The time taken by the instrument to fracture was recorded in seconds. The number of cycles to fracture (NCF) was analyzed with the help of the equation (NCF = time to fracture × rpm/60). Surfaces at the site of fracture were examined with the help of a scanning electron microscope (EVOLS10, ZEISS) at magnification (300x and 2000x). RESULTS: It was noticed that there was a statistically significant increase in cyclic fatigue when sodium chloride was used as an endodontic irrigant instead of distilled water. The increase in cyclic fatigue was also observed when 5.25% sodium chloride was used instead of 2.5% sodium hypochlorite. Cyclic fatigue increased on change in temperature from 25 to 37°C and from 37 to 60°C. The difference was statistically significant (p < 0.05). It was observed that resistance against cyclic fatigue on treatment with different irrigation solutions at different temperatures was in the order of GenEndo > Protaper Gold > Hero Gold > EdgeFile X3. CONCLUSION: The resistance against cyclic fatigue in new NiTi rotary files can be affected significantly by different concentrations of sodium hypochlorite irrigant solution and the GenEndo rotary endodontic instrument has the maximum resistance against cyclic fatigue. CLINICAL SIGNIFICANCE: Irrigation of the root canal with irrigants, such as sodium hypochlorite (NaOCl) has been recommended strongly. NaOCl is used in the range of 0.5 and 6.5% concentration owing to its antimicrobial activity and tissue dissolution activities, particularly at higher temperatures. It has been postulated that fatigue of rotary endodontic instruments can be influenced by adjoining medium and their concentration.


Assuntos
Instrumentos Odontológicos , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Cloreto de Sódio , Hipoclorito de Sódio , Aço Inoxidável , Temperatura , Titânio , Água
14.
Aust Dent J ; 68 Suppl 1: S24-S38, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37960998

RESUMO

The introduction of nickel-titanium (NiTi) mechanical instruments dramatically changed clinical endodontics over the last few decades. Before NiTi, it was necessary to use more instruments to create an ideal root canal shape, and many approaches, sequences and techniques were developed over the years. Recently, NiTi endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments to improve their root canal preparation outcomes and reduce associated canal preparation risks during root canal treatment. Heat treatment is one of the most fundamental approaches to improving the fatigue resistance and flexibility of NiTi endodontic instruments. In addition, new kinematics have been developed to offer greater safety and efficiency. This narrative review describes the general properties and manufacturing of NiTi instruments, and the mechanical system evolution of NiTi instruments.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , Humanos , Preparo de Canal Radicular/métodos , Níquel , Titânio , Desenho de Equipamento , Teste de Materiais , Instrumentos Odontológicos
15.
BMC Oral Health ; 23(1): 825, 2023 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-37904159

RESUMO

BACKGROUND: The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of different heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures. METHODS: Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05). RESULTS: DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, VB, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05). CONCLUSIONS: Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, especially in the NCF values of instruments with a mixture of martensite/R-phase and austenite phases at the tested temperatures.


Assuntos
Temperatura Alta , Titânio , Humanos , Titânio/química , Níquel/química , Temperatura Corporal , Falha de Equipamento , Ligas Dentárias/química , Teste de Materiais , Instrumentos Odontológicos , Preparo de Canal Radicular , Estresse Mecânico
16.
Clin Oral Investig ; 27(11): 6291-6319, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37704917

RESUMO

OBJECTIVE: This systematic review/meta-analysis investigated the influence of NaOCl on cyclic fatigue resistance of endodontic NiTi instruments. MATERIALS AND METHODS: A systematic search until July 2022 in PubMed/MEDLINE, Embase, Scopus, Web of Science, SciELO, Cochrane Library, and grey literature was conducted. According to the PECOS strategy, only in vitro studies evaluating the effects of NaOCl on the cyclic fatigue resistance of NiTi instruments were eligible. Cyclic fatigue resistance was the primary outcome. A modified Joanna Briggs Institute's Checklist was used for risk of bias assessment. RESULTS: Of the 2,445 records screened, 37 studies were included. Most studies used simulated canals made of stainless-steel block with severe to moderate curvatures. NaOCl concentration varied from 1-6%, mainly at 37 °C. Regarding fatigue resistance, 23 studies using 1.2% to 6% NaOCl showed a reduction in the resistance compared to the control groups, especially when pre-heated. Four meta-analyses were performed according to the tested NiTi systems. The meta-analyses indicated that the PTU F2 files had higher reduction of fatigue resistance after exposure to 5.25% NaOCl; no differences between NaOCl and no immersion were observed for Reciproc R25, WaveOne 25.08, and WaveOne Gold Primary files. Included studies had low risk of bias. CONCLUSION: NaOCl appears to reduce cyclic fatigue resistance of certain NiTi files, especially when they are pre-heated, particularly in conventional NiTi files compared to some heat-treated instruments. It is possible that the temperature of the solution may have a greater influence on resistance than NaOCl itself. Important to note that an overall tendency toward no significant influence was observed among various systems. CLINICAL RELEVANCE: Precautions are necessary when a pre-heated high-concentration NaOCl is used to enhance its properties during root canal preparation, mainly using conventional wire.


Assuntos
Níquel , Hipoclorito de Sódio , Titânio , Preparo de Canal Radicular , Falha de Equipamento , Instrumentos Odontológicos , Desenho de Equipamento , Teste de Materiais
17.
Int Endod J ; 56(11): 1412-1428, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37698946

RESUMO

AIM: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Desenho de Equipamento , Estresse Mecânico , Preparo de Canal Radicular , Titânio/química , Metalurgia , Ouro , Teste de Materiais
18.
Am J Dent ; 36(4): 188-192, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37587029

RESUMO

PURPOSE: To evaluate the smoothness provided by a one-step finishing and polishing system and its maintenance after hydrothermal aging and brushing of a nanofilled resin composite. METHODS: 96 samples of the nanofilled composite Filtek Z350 XT were fabricated, which, after initial average roughness (Ra) analysis, were randomly distributed into three groups, according to the selected finishing and polishing system. The multi-step systems Sof-Lex (aluminum oxide discs) and Jiffy (bullet-shaped abrasive rubbers), and the one-step system OneGloss (bullet-shaped abrasive rubber) were used. After finishing and polishing, a new Ra measurement was performed, and then half of the samples from each group were stored in artificial saliva for 12 months, while the other half underwent aging processes associating hydrothermal cycles (10,000 cycles at 5-55°C) followed by brushing (5,500 strokes), with a mid-abrasive (Crest Cavity Protection) dentifrice slurry, simulating a 12-month period in the oral cavity. Final Ra measurements were performed, and data were analyzed by generalized linear model and Tukey's test (α= 5%). RESULTS: There was interaction between finishing and polishing system and aging (P< 0.001). The one-step abrasive rubber point provided significantly higher Ra values compared to the multi-step systems, and with the discs there was higher smoothness than with the rubber point sequence. This result was maintained after 12 months in artificial saliva, but after hydrothermal cycles followed by brushing, one-step and multi-step abrasive rubber points no longer significantly differed from each other. Only for the one-step system, hydrothermal cycles followed by brushing significantly reduced Ra. CLINICAL SIGNIFICANCE: Although hydrothermal cycles followed by brushing may have increased the smoothness of nanofilled composite finished and polished with the one-step system, only the multi-step system provided a surface within the roughness threshold to avoid biofilm retention.


Assuntos
Cárie Dentária , Borracha , Humanos , Biofilmes , Instrumentos Odontológicos , Saliva Artificial
19.
Aust Endod J ; 49(3): 592-598, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37592880

RESUMO

The aim of this study was to compare the cyclic fatigue resistance of nickel-titanium instruments inside single and double-curved canals at different temperatures. 160 HyFlex EDM #20.05 (HEDM), VDW.ROTATE #20.05 and #25.06, Mtwo #25.06 were randomised (n = 10) for the dynamic cyclic fatigue tests according to the curvature (i.e. single and double) at 20° ± 1°C and 35° ± 1°C. The number of cycles to fracture (NCF) was analysed by two-way ANOVA with p < 0.05. Fatigue resistance of all instruments significantly decreased at body temperature in single and double curvatures, except for HEDM in double curvature. The NCF was significantly lower in double curvature than single at both temperatures for all files, except for VDW.ROTATE #20.05 at 35° ± 1°C. Within the study limitations, temperature significantly impaired cyclic fatigue resistance of all files except HEDM #20.05 in double curvature. Similarly, double curvature had a detrimental effect on cyclic fatigue resistance of all files except for VDW.ROTATE #20.05 at body temperature.


Assuntos
Instrumentos Odontológicos , Níquel , Titânio , Temperatura Corporal , Ligas Dentárias , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Resistência à Flexão
20.
Rev. Asoc. Odontol. Argent ; 111(2): 1110871, mayo-ago. 2023. ilus
Artigo em Espanhol | LILACS | ID: biblio-1537147

RESUMO

El objetivo de esta comunicación es describir y analizar el sistema BlueShaper para la preparación quirúrgica mecaniza- da de los conductos radiculares. El sistema dispone de un set básico de 4 limas: Z1, Z2, Z3 y Z4, con un D0 de 0,14 mm, 0,17 mm, 0,19 mm y 0,25 mm respectivamente y conicidad variable que oscila entre el 2 y 10 %. La lima Z1 posee una aleación Pink, que le confiere mayor resistencia a la torsión y una gran capacidad de corte. Las limas Z2, Z3 y Z4 presentan una aleación Blue que aumenta la resistencia a la fatiga cíclica e incrementa su flexibilidad. Para conductos radiculares más amplios se incluyen, además, las limas Z5, Z6 y Z7. La empresa comer- cializa conos de gutapercha BlueShaper que se corresponden con las limas Z3, Z4, Z5, Z6 y Z7. El sistema de limas mul- tialeación Blue Shaper podría considerarse como un nuevo aporte clínico para la preparación mecánica de los conductos radiculares (AU)


The aim of this communication was to describe and analyze the BlueShaper system for the mechanized surgical preparation of root canals. The system has a basic set of 4 files: Z1, Z2, Z3 and Z4, with 0.14 mm, 0.17 mm, 0.19 mm and 0.25 mm DO respective- ly, and variable conicity ranging between 2 and 10 %. Z1 file has a Pink alloy, which gives it greater resistance to torsion and great cutting capacity. The Z2, Z3 and Z4 files feature a Blue alloy that increases resistance to cyclic fatigue and increases their flexibility. For larger root canals, the Z5, Z6 and Z7 files are also included. The company supplies specific BlueShaper ́s gutta-percha cones for Z3, Z4, Z5, Z6 and Z7 files. The BlueShaper multialloy file system could be consid- ered as a new clinical contribution for the mechanical prepa- ration of root canals (AU)


Assuntos
Preparo de Canal Radicular/instrumentação , Ligas Dentárias , Instrumentos Odontológicos , Rotação , Termodinâmica , Torção Mecânica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...