Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136.117
Filtrar
1.
PLoS One ; 19(4): e0300108, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38568899

RESUMO

Delving into the complexities of embodied cognition unveils the intertwined influence of mind, body, and environment. The connection of physical activity with cognition sparks a hypothesis linking motion and personality traits. Hence, this study explored whether personality traits could be linked to biomechanical variables characterizing running forms. To do so, 80 runners completed three randomized 50-m running-trials at 3.3, 4.2, and 5m/s during which their running biomechanics [ground contact time (tc), flight time (tf), duty factor (DF), step frequency (SF), leg stiffness (kleg), maximal vertical ground reaction force (Fmax), and maximal leg compression of the spring during stance (ΔL)] was evaluated. In addition, participants' personality traits were assessed through the Myers-Briggs Type Indicator (MBTI) test. The MBTI classifies personality traits into one of two possible categories along four axes: extraversion-introversion; sensing-intuition; thinking-feeling; and judging-perceiving. This exploratory study offers compelling evidence that personality traits, specifically sensing and intuition, are associated with distinct running biomechanics. Individuals classified as sensing demonstrated a more grounded running style characterized by prolonged tc, shorter tf, higher DF, and greater ΔL compared to intuition individuals (p≤0.02). Conversely, intuition runners exhibited a more dynamic and elastic running style with a shorter tc and higher kleg than their sensing counterparts (p≤0.02). Post-hoc tests revealed a significant difference in tc between intuition and sensing runners at all speeds (p≤0.02). According to the definition of each category provided by the MBTI, sensing individuals tend to focus on concrete facts and physical realities while intuition individuals emphasize abstract concepts and patterns of information. These results suggest that runners with sensing and intuition personality traits differ in their ability to use their lower limb structures as springs. Intuition runners appeared to rely more in the stretch-shortening cycle to energetically optimize their running style while sensing runners seemed to optimize running economy by promoting more forward progression than vertical oscillations. This study underscores the intriguing interplay between personality traits of individuals and their preferred movement patterns.


Assuntos
Intuição , Corrida , Humanos , Fenômenos Biomecânicos , Extremidade Inferior , Emoções
2.
Nat Commun ; 15(1): 2861, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570505

RESUMO

Tissue integrity is sensitive to temperature, tension, age, and is sustained throughout life by adaptive cell-autonomous or extrinsic mechanisms. Safeguarding the remarkably-complex architectures of neurons and glia ensures age-dependent integrity of functional circuits. Here, we report mechanisms sustaining the integrity of C. elegans CEPsh astrocyte-like glia. We combine large-scale genetics with manipulation of genes, cells, and their environment, quantitative imaging of cellular/ subcellular features, tissue material properties and extracellular matrix (ECM). We identify mutants with age-progressive, environment-dependent defects in glial architecture, consequent disruption of neuronal architecture, and abnormal aging. Functional loss of epithelial Hsp70/Hsc70-cochaperone BAG2 causes ECM disruption, altered tissue biomechanics, and hypersensitivity of glia to environmental temperature and mechanics. Glial-cell junctions ensure epithelia-ECM-CEPsh glia association. Modifying glial junctions or ECM mechanics safeguards glial integrity against disrupted BAG2-proteostasis. Overall, we present a finely-regulated interplay of proteostasis-ECM and cell junctions with conserved components that ensures age-progressive robustness of glial architecture.


Assuntos
Caenorhabditis elegans , Neuroglia , Animais , Caenorhabditis elegans/genética , Astrócitos , Fenômenos Biomecânicos , Proteostase , Matriz Extracelular/metabolismo , Junções Intercelulares
3.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562639

RESUMO

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Escápula , Amplitude de Movimento Articular , Fenômenos Biomecânicos
4.
Sci Data ; 11(1): 343, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580698

RESUMO

The sports industry is witnessing an increasing trend of utilizing multiple synchronized sensors for player data collection, enabling personalized training systems with multi-perspective real-time feedback. Badminton could benefit from these various sensors, but there is a scarcity of comprehensive badminton action datasets for analysis and training feedback. Addressing this gap, this paper introduces a multi-sensor badminton dataset for forehand clear and backhand drive strokes, based on interviews with coaches for optimal usability. The dataset covers various skill levels, including beginners, intermediates, and experts, providing resources for understanding biomechanics across skill levels. It encompasses 7,763 badminton swing data from 25 players, featuring sensor data on eye tracking, body tracking, muscle signals, and foot pressure. The dataset also includes video recordings, detailed annotations on stroke type, skill level, sound, ball landing, and hitting location, as well as survey and interview data. We validated our dataset by applying a proof-of-concept machine learning model to all annotation data, demonstrating its comprehensive applicability in advanced badminton training and research.


Assuntos
Desempenho Atlético , Esportes com Raquete , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Extremidade Inferior , Esportes com Raquete/fisiologia , Humanos
5.
Sci Rep ; 14(1): 7909, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575582

RESUMO

This retrospective study aimed to investigate the impact of lumbar disc herniation (LDH) on vertebral axial rotation (VAR) in the lumbar spine, focusing on both close and distant neighboring vertebrae. A total of 516 patients with LDH and an equal number of healthy individuals were included in the study, matched for age and gender. The degree of axial rotation for each lumbar spine vertebra was assessed using the Nash-Moe index. The results revealed that the prevalence of VAR in the lumbar spine was significantly higher in the LDH group compared to the Control group (65.7% vs 46.7%, P < 0.001). Among the LDH group, the L2 vertebra had the highest frequency of VAR (49.5%), followed by L1 (45.1%), and then L3 to L5 (33.6%, 8.9%, 3.1%, respectively). A similar pattern was observed in the Control group (L2, 39.8%; L1, 34.6%; L3, 23.2%; L4, 3.1%; L5, 0.8%). Furthermore, the study found that disc herniation was associated with a higher incidence of VAR not only in close neighboring vertebrae but also in distant neighboring vertebrae. This indicates that the biomechanical influence of LDH extends beyond just the immediate adjacent vertebrae. To identify potential risk factors for VAR in LDH patients, multivariate analysis was performed. The results revealed that age was an independent risk factor for VAR (OR 1.022, 95% CI [1.011, 1.034], P < 0.001). However, the duration of symptoms and presence of back pain were not found to be significant risk factors for VAR.


Assuntos
Deslocamento do Disco Intervertebral , Humanos , Deslocamento do Disco Intervertebral/epidemiologia , Estudos Retrospectivos , Rotação , Prevalência , Vértebras Lombares/diagnóstico por imagem , Fatores de Risco , Fenômenos Biomecânicos
6.
J Orthop Surg Res ; 19(1): 224, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575992

RESUMO

BACKGROUND: Rotator cuff (RC) tears are a common cause of shoulder dysfunction and pain, posing significant challenges for orthopedic surgeons. Grafts have been proposed as a solution to augment or bridge torn tendons, but optimal clinical outcomes are not always achieved due to poor graft integration, suboptimal mechanical properties, and immunological reactions. The aim of this study was to investigate the biomechanical, CT and histological results of RC reconstruction using an intrasynovial tendon autograft, in a chronic large tear subscapularis rabbit model. METHODS: Twenty-six adult male Zealand white rabbits were used in this study. Large defects in the subscapularis tendons were produced bilaterally in 20 rabbits. After 6 weeks, secondary procedures were performed to the right shoulder of the rabbits, which were reconstructed with an intrasynovial interposition autograft (graft group). The left shoulder did not undergo any further treatment (defect group). The specimens were randomly divided into two equal time groups and underwent biomechanical testing, CT analysis, and histological evaluation at 6, and 12 weeks after reconstruction. In addition, 6 rabbits that were not operated, were used as a control group. RESULTS: At 12 weeks post-repair, the graft group exhibited a significant increase in ultimate failure load compared to the defect group (p < 0.05). Furthermore, the 12-week graft group demonstrated comparable stiffness to that of the control group. CT analysis indicated no significant progression of intramuscular fat accumulation in both graft groups, in contrast to the 12-week defect group when compared to the control group. Finally, histological evaluation revealed a gradual integration of the graft with the host tissue at 12 weeks. CONCLUSION: Our study suggests that intrasynovial flexor tendon autografts hold promise as an effective interposition graft for the reconstruction of chronic large RC tears, as they improve the biomechanical and biological properties of the repaired tendon. Nonetheless, further investigations in preclinical large animal models are warranted to validate and extrapolate these findings to human studies.


Assuntos
Lesões do Manguito Rotador , Animais , Humanos , Coelhos , Masculino , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Autoenxertos , Cicatrização , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Tomografia Computadorizada por Raios X , Fenômenos Biomecânicos
7.
J Orthop Surg Res ; 19(1): 209, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561837

RESUMO

BACKGROUND: Previous studies have demonstrated the clinical efficacy of decompression alone in lower-grade spondylolisthesis. A higher rate of surgical revision and a lower rate of back pain relief was also observed. However, there is a lack of relevant biomechanical evidence after decompression alone for lower-grade spondylolisthesis. PURPOSE: Evaluating the biomechanical characteristics of total laminectomy, hemilaminectomy, and facetectomy for lower-grade spondylolisthesis by analyzing the range of motion (ROM), intradiscal pressure (IDP), annulus fibrosus stress (AFS), facet joints contact force (FJCF), and isthmus stress (IS). METHODS: Firstly, we utilized finite element tools to develop a normal lumbar model and subsequently constructed a spondylolisthesis model based on the normal model. We then performed total laminectomy, hemilaminectomy, and one-third facetectomy in the normal model and spondylolisthesis model, respectively. Finally, we analyzed parameters, such as ROM, IDP, AFS, FJCF, and IS, for all the models under the same concentrate force and moment. RESULTS: The intact spondylolisthesis model showed a significant increase in the relative parameters, including ROM, AFS, FJCF, and IS, compared to the intact normal lumbar model. Hemilaminectomy and one-third facetectomy in both spondylolisthesis and normal lumbar models did not result in an obvious change in ROM, IDP, AFS, FJCF, and IS compared to the pre-operative state. Moreover, there was no significant difference in the degree of parameter changes between the spondylolisthesis and normal lumbar models after undergoing the same surgical procedures. However, total laminectomy significantly increased ROM, AFS, and IS and decreased the FJCF in both normal lumbar models and spondylolisthesis models. CONCLUSION: Hemilaminectomy and one-third facetectomy did not have a significant impact on the segment stability of lower-grade spondylolisthesis; however, patients with LDS undergoing hemilaminectomy and one-third facetectomy may experience higher isthmus stress on the surgical side during rotation. In addition, total laminectomy changes the biomechanics in both normal lumbar models and spondylolisthesis models.


Assuntos
Fusão Vertebral , Espondilolistese , Humanos , Espondilolistese/cirurgia , Análise de Elementos Finitos , Vértebras Lombares/cirurgia , Laminectomia/métodos , Fusão Vertebral/métodos , Fenômenos Biomecânicos , Amplitude de Movimento Articular/fisiologia , Descompressão
8.
Sci Rep ; 14(1): 8160, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589521

RESUMO

To analyze the changing trend of CH and CRF values under different influencing factors in T2DM patients. A total of 650 patients with T2DM were included. We discovered that the course of T2DM, smoking history, BMI, and FBG, DR, HbA1c, TC, TG, and LDL-C levels were common risk factors for T2DM, while HDL-C levels were a protective factor. Analyzing the CH and CRF values according to the course of diabetes, we discovered that as T2DM continued to persist, the values of CH and CRF gradually decreased. Moreover, with the increase in FBG levels and the accumulation of HbA1c, the values of CH and CRF gradually decreased. In addition, in patients with HbA1c (%) > 12, the values of CH and CRF decreased the most, falling by 1.85 ± 0.33 mmHg and 1.28 ± 0.69 mmHg, respectively. Compared with the non-DR group, the CH and CRF values gradually decreased in the mild-NPDR, moderate-NPDR, severe-NPDR and PDR groups, with the lowest CH and CRF values in the PDR group. In patients with T2DM, early measurement of corneal biomechanical properties to evaluate the change trend of CH and CRF values in different situations will help to identify and prevent diabetic keratopathy in a timely manner.


Assuntos
Córnea , Diabetes Mellitus Tipo 2 , Humanos , Hemoglobinas Glicadas , Fenômenos Biomecânicos , Pressão Intraocular , Elasticidade , Tonometria Ocular
9.
BMC Musculoskelet Disord ; 25(1): 271, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589829

RESUMO

BACKGROUND: Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. METHODS: Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) - SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. RESULTS: Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. CONCLUSIONS: A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur , Humanos , Parafusos Ósseos/efeitos adversos , Fenômenos Biomecânicos , Fixadores Internos , Fixação Interna de Fraturas , Fraturas do Fêmur/etiologia , Peso Corporal
10.
PLoS One ; 19(4): e0301230, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38593122

RESUMO

BACKGROUND: Instrumented gait analysis (IGA) has been around for a long time but has never been shown to be useful for improving patient outcomes. In this study we demonstrate the potential utility of IGA by showing that machine learning models are better able to estimate treatment outcomes when they include both IGA and clinical (CLI) features compared to when they include CLI features alone. DESIGN: We carried out a retrospective analysis of data from ambulatory children diagnosed with cerebral palsy who were seen at least twice at our gait analysis center. Individuals underwent a variety of treatments (including no treatment) between sequential gait analyses. We fit Bayesian Additive Regression Tree (BART) models that estimated outcomes for mean stance foot progression to demonstrate the approach. We built two models: one using CLI features only, and one using CLI and IGA features. We then compared the models' performance in detail. We performed similar, but less detailed, analyses for a number of other outcomes. All results were based on independent test data from a 70%/30% training/testing split. RESULTS: The IGA model was more accurate than the CLI model for mean stance-phase foot progression outcomes (RMSEIGA = 11∘, RMSECLI = 13∘) and explained more than 1.5 × as much of the variance (R2IGA = .45, R2CLI = .28). The IGA model outperformed the CLI model for every level of treatment complexity, as measured by number of simultaneous surgeries. The IGA model also exhibited superior performance for estimating outcomes of mean stance-phase knee flexion, mean stance-phase ankle dorsiflexion, maximum swing-phase knee flexion, gait deviation index (GDI), and dimensionless speed. INTERPRETATION: The results show that IGA has the potential to be useful in the treatment planning process for ambulatory children diagnosed with cerebral palsy. We propose that the results of machine learning outcome estimators-including estimates of uncertainty-become the primary IGA tool utilized in the clinical process, complementing the standard medical practice of conducting a through patient history and physical exam, eliciting patient goals, reviewing relevant imaging data, and so on.


Assuntos
Paralisia Cerebral , Transtornos Neurológicos da Marcha , Criança , Humanos , Análise da Marcha , Estudos Retrospectivos , Paralisia Cerebral/cirurgia , Teorema de Bayes , Marcha , Amplitude de Movimento Articular , Imunoglobulina A , Fenômenos Biomecânicos , Transtornos Neurológicos da Marcha/terapia
11.
J R Soc Interface ; 21(213): 20230592, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593841

RESUMO

The mechanical characterization of the oesophagus is essential for applications such as medical device design, surgical simulations and tissue engineering, as well as for investigating the organ's pathophysiology. However, the material response of the oesophagus has not been established ex vivo in regard to the more complex aspects of its mechanical behaviour using fresh, human tissue: as of yet, in the literature, only the hyperelastic response of the intact wall has been studied. Therefore, in this study, the layer-dependent, anisotropic, visco-hyperelastic behaviour of the human oesophagus was investigated through various mechanical tests. For this, cyclic tests, with increasing stretch levels, were conducted on the layers of the human oesophagus in the longitudinal and circumferential directions and at two different strain rates. Additionally, stress-relaxation tests on the oesophageal layers were carried out in both directions. Overall, the results show discrete properties in each layer and direction, highlighting the importance of treating the oesophagus as a multi-layered composite material with direction-dependent behaviour. Previously, the authors conducted layer-dependent cyclic experimentation on formalin-embalmed human oesophagi. A comparison between the fresh and embalmed tissue response was carried out and revealed surprising similarities in terms of anisotropy, strain-rate dependency, stress-softening and hysteresis, with the main difference between the two preservation states being the magnitude of these properties. As formalin fixation is known to notably affect the formation of cross-links between the collagen of biological materials, the differences may reveal the influence of cross-links on the mechanical behaviour of soft tissues.


Assuntos
Esôfago , Projetos de Pesquisa , Humanos , Estresse Mecânico , Esôfago/fisiologia , Anisotropia , Fenômenos Biomecânicos , Resistência à Tração
12.
Prosthet Orthot Int ; 48(2): 213-222, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38595180

RESUMO

BACKGROUND: Nonsurgical guidelines recommend implementing a correctly fitted bra when managing back pain among larger breasted women. Achieving this is challenging with current bra solutions, sizing principles, and fitting approaches. Persistent wearing of an ill-fitting bra can cause negative health implications, including non-specific back pain. OBJECTIVES: This study investigated immediate and short-term biomechanical and pain responses to changing breast support garment among larger breasted women with non-specific back pain. METHODS: Participants (n = 24) performed a standing task, drop jumps, and seated typing tasks while bra and spinal kinematic data were recorded. Five breast support conditions were assessed: participants' usual bra (control), a professionally fitted bra in the immediate term (standard) and after 4 weeks wear (standard28), and a bra with an alternative design, measurement, and fitting approach in both the immediate term (alternative) and after 4 weeks wear (alternative28). A bra fit assessment and clinical pain/disability questionnaires were included. RESULTS: All participants failed the bra fit assessment in the control bra, compared with 87.5% (n = 21) in the standard and 4.2% (n = 1) in the alternative bras. The standard28 and alternative28 bras provided symptomatic relief, with the alternative28 bra improving a greater number of outcome measures. Reduced nipple-sternal-notch distance was observed only in the alternative28 bra condition. CONCLUSIONS: Symptomatic relief may be associated with the resting position of the breast tissue on the anterior chest wall. The alternative bra may provide potential clinical benefit if implemented as part of a nonsurgical or conservative pain management strategy. Alternative breast support garments should be considered to provide solutions to the problems associated with traditional bras.


Assuntos
Mama , Vestuário , Feminino , Humanos , Mama/fisiologia , Dor nas Costas/terapia , Inquéritos e Questionários , Fenômenos Biomecânicos
13.
BMC Musculoskelet Disord ; 25(1): 268, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582828

RESUMO

BACKGROUND: Knee osteoarthritis (KOA) is a prevalent and debilitating condition that markedly affects the sit-to-stand (STS) activity of patients, a prerequisite for daily activities. Biomechanical recognition of movements in patients with mild KOA is currently attracting attention. However, limited studies have been conducted solely on the observed differences in sagittal plane movement and muscle activation. AIM: This study aimed to identify three-dimensional biomechanical and muscle activation characteristics of the STS activity in patients with mild KOA. METHODS: A cross-sectional study was conducted to observe the differences between patients with mild KOA and a control group (CG). It was conducted to observe the differences in muscle activation, including root mean square (RMS%) and integrated electromyography (items), kinematic parameters like range of motion (ROM) and maximum angular velocity, as well as dynamic parameters such as joint moment and vertical ground reaction force (vGRF). RESULTS: Patients with mild KOA had a higher body mass index and longer task duration. In the sagittal plane, patients with KOA showed an increased ROM of the pelvic region, reduced ROM of the hip-knee-ankle joint, and diminished maximum angular velocity of the knee-ankle joint. Furthermore, patients with KOA displayed increased knee-ankle joint ROM in the coronal plane and decreased ankle joint ROM in the horizontal plane. Integrated vGRF was higher in both lower limbs, whereas the vGRF of the affected side was lower. Furthermore, patients showed a decreased peak adduction moment (PADM) and increased peak external rotation moment in the knee joint and smaller PADM and peak internal rotation moment in the ankle joint. The affected side exhibited decreased RMS% and iEMG values of the gluteus medius, vastus medialis, and vastus lateralis muscles, as well as a decreased RMS% of the rectus femoris muscle. Conversely, RMS% and iEMG values of the biceps femoris, lateral gastrocnemius, and medial gastrocnemius muscles were higher. CONCLUSION: The unbalanced activation characteristics of the anterior and posterior muscle groups, combined with changes in joint moment in the three-dimensional plane of the affected joint, may pose a potential risk of injury to the irritated articular cartilage.


Assuntos
Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/diagnóstico , Fenômenos Biomecânicos , Estudos Transversais , Extremidade Inferior/fisiologia , Músculo Esquelético/fisiologia , Articulação do Joelho/fisiologia , Eletromiografia
14.
BMC Oral Health ; 24(1): 425, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38582842

RESUMO

BACKGROUND: Clinical scenarios frequently present challenges when patients exhibit asymmetrical mandibular atrophy. The dilemma arises: should we adhere to the conventional All-on-4 technique, or should we contemplate placing vertically oriented implants on the side with sufficient bone mass? This study aims to employ three-dimensional finite element analysis to simulate and explore the biomechanical advantages of each approach. METHODS: A finite element model, derived from computed tomography (CT) data, was utilized to simulate the nonhomogeneous features of the mandible. Three configurations-All-on-4, All-on-5-v and All-on-5-o were studied. Vertical and oblique forces of 200 N were applied unilaterally, and vertical force of 100 N was applied anteriorly to simulate different masticatory mechanisms. The maximum von Mises stresses on the implant and framework were recorded, as well as the maximum equivalent strain in the peri-implant bone. RESULTS: The maximum stress values for all designs were located at the neck of the distal implant, and the maximum strains in the bone tissue were located around the distal implant. The All-on-5-o and All-on-5-v models exhibited reduced stresses and strains compared to All-on-4, highlighting the potential benefits of the additional implant. There were no considerable differences in stresses and strains between the All-on-5-o and All-on-5-v groups. CONCLUSIONS: With the presence of adequate bone volume on one side and severe atrophy of the contralateral bone, while the "All-on-4 concept" is a viable approach, vertical implant placement optimizes the transfer of forces between components and tissues.


Assuntos
Implantes Dentários , Humanos , Fenômenos Biomecânicos , Análise de Elementos Finitos , Estresse Mecânico , Análise do Estresse Dentário/métodos , Prótese Dentária Fixada por Implante , Mandíbula/diagnóstico por imagem , Atrofia
15.
Sensors (Basel) ; 24(5)2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38474946

RESUMO

Roller skiing is one primary form of training method as it is an off-snow equivalent to cross-country (XC) skiing during the dry land preseason training, but the results could only be applied to on-snow skiing with appropriate caution. The aim of this present study was to investigate the similarities and differences in roller skiing and on-snow skiing with the diagonal stride (DS) technique. Six youth (age: 14.3 ± 2.9 years) skiers participated in this study. Two high-definition video camcorders and FastMove 3D Motion 2.23.3.3101 were used to obtain the three-dimensional kinematic data. The cycle characteristics and joint angle ROM of the DS technique while skiing on different surfaces were similar. Almost all joint angle-time curves that were obtained from roller skiing showed a moderate-to-high degree of similarity to the angle-time curves obtained from on-snow skiing, except the hip adduction-abduction angle. The differences between roller skiing and on-snow skiing were mainly found in the body and calf anteversion angles, and the joint angles at critical instants. DS roller skiing can simulate DS on-snow skiing to a large extent in youth athletes. The hip movement, knee flexion, and calf anteversion at ski/roller ski touchdown and take-off, pole inclination at pole touchdown, body anteversion angle, and trunk anteversion angle at pole touchdown were the points that required caution when transferring preseason practice roller skiing to on-snow skiing.


Assuntos
Esqui , Humanos , Adolescente , Criança , Consumo de Oxigênio , Perna (Membro) , Fenômenos Biomecânicos , Movimento (Física)
16.
Sensors (Basel) ; 24(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38474980

RESUMO

This study investigates the biomechanical impact of a passive Arm-Support Exoskeleton (ASE) on workers in wool textile processing. Eight workers, equipped with surface electrodes for electromyography (EMG) recording, performed three industrial tasks, with and without the exoskeleton. All tasks were performed in an upright stance involving repetitive upper limbs actions and overhead work, each presenting different physical demands in terms of cycle duration, load handling and percentage of cycle time with shoulder flexion over 80°. The use of ASE consistently lowered muscle activity in the anterior and medial deltoid compared to the free condition (reduction in signal Root Mean Square (RMS) -21.6% and -13.6%, respectively), while no difference was found for the Erector Spinae Longissimus (ESL) muscle. All workers reported complete satisfaction with the ASE effectiveness as rated on Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST), and 62% of the subjects rated the usability score as very high (>80 System Usability Scale (SUS)). The reduction in shoulder flexor muscle activity during the performance of industrial tasks is not correlated to the level of ergonomic risk involved. This preliminary study affirms the potential adoption of ASE as support for repetitive activities in wool textile processing, emphasizing its efficacy in reducing shoulder muscle activity. Positive worker acceptance and intention to use ASE supports its broader adoption as a preventive tool in the occupational sector.


Assuntos
Exoesqueleto Energizado , Humanos , Projetos Piloto , Extremidade Superior/fisiologia , Músculo Esquelético/fisiologia , Ombro/fisiologia , Eletromiografia , Fenômenos Biomecânicos
17.
Sensors (Basel) ; 24(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38474989

RESUMO

The knee abduction moment (KAM) has been identified as a significant predictor of anterior cruciate ligament (ACL) injury risk; however, the cost and time demands associated with collecting three-dimensional (3D) kinetic data have prompted the need for alternative solutions. Wearable inertial measurement units (IMUs) have been explored as a potential solution for quantitative on-field assessment of injury risk. Most previous work has focused on angular velocity data, which are highly susceptible to bias and noise relative to acceleration data. The purpose of this pilot study was to assess the relationship between KAM and body segment acceleration during sport-specific movements. Three functional tasks were selected to analyze peak KAM using optical motion capture and force plates as well as peak triaxial segment accelerations using IMUs. Moderate correlations with peak KAM were observed for peak shank acceleration during single-leg hop; peak trunk, thigh, and shank accelerations during a deceleration task; and peak trunk, pelvis, and shank accelerations during a 45° cut. These findings provide preliminary support for the use of wearable IMUs to identify peak KAM during athletic tasks.


Assuntos
Lesões do Ligamento Cruzado Anterior , Esportes , Humanos , Projetos Piloto , Fenômenos Biomecânicos , Articulação do Joelho , Extremidade Inferior
18.
Sensors (Basel) ; 24(5)2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38475012

RESUMO

Motion reconstruction using wearable sensors enables broad opportunities for gait analysis outside laboratory environments. Inertial Measurement Unit (IMU)-based foot trajectory reconstruction is an essential component of estimating the foot motion and user position required for any related biomechanics metrics. However, limitations remain in the reconstruction quality due to well-known sensor noise and drift issues, and in some cases, limited sensor bandwidth and range. In this work, to reduce drift in the height direction and handle the impulsive velocity error at heel strike, we enhanced the integration reconstruction with a novel kinematic model that partitions integration velocity errors into estimates of acceleration bias and heel strike vertical velocity error. Using this model, we achieve reduced height drift in reconstruction and simultaneously accomplish reliable terrain determination among level ground, ramps, and stairs. The reconstruction performance of the proposed method is compared against the widely used Error State Kalman Filter-based Pedestrian Dead Reckoning and integration-based foot-IMU motion reconstruction method with 15 trials from six subjects, including one prosthesis user. The mean height errors per stride are 0.03±0.08 cm on level ground, 0.95±0.37 cm on ramps, and 1.27±1.22 cm on stairs. The proposed method can determine the terrain types accurately by thresholding on the model output and demonstrates great reconstruction improvement in level-ground walking and moderate improvement on ramps and stairs.


Assuntos
Algoritmos , , Humanos , Caminhada , Movimento (Física) , Aceleração , Fenômenos Biomecânicos , Marcha
19.
Sensors (Basel) ; 24(5)2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38475017

RESUMO

When performing lifting tasks at work, the Lifting Index (LI) is widely used to prevent work-related low-back disorders, but it presents criticalities pertaining to measurement accuracy and precision. Wearable sensor networks, such as sensorized insoles and inertial measurement units, could improve biomechanical risk assessment by enabling the computation of an adaptive LI (aLI) that changes over time in relation to the actual method of carrying out lifting. This study aims to illustrate the concepts and mathematics underlying aLI computation and compare aLI calculations in real-time using wearable sensors and force platforms with the LI estimated with the standard method used by ergonomists and occupational health and safety technicians. To reach this aim, 10 participants performed six lifting tasks under two risk conditions. The results show us that the aLI value rapidly converges towards the reference value in all tasks, suggesting a promising use of adaptive algorithms and instrumental tools for biomechanical risk assessment.


Assuntos
Algoritmos , Remoção , Humanos , Medição de Risco , Matemática , Fenômenos Biomecânicos
20.
Sensors (Basel) ; 24(5)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38475055

RESUMO

The study aims to construct an inertial measuring system for the application of amputee subjects wearing a prosthesis. A new computation scheme to process inertial data by installing seven wireless inertial sensors on the lower limbs was implemented and validated by comparing it with an optical motion capture system. We applied this system to amputees to verify its performance for gait analysis. The gait parameters are evaluated to objectively assess the amputees' prosthesis-wearing status. The Madgwick algorithm was used in the study to correct the angular velocity deviation using acceleration data and convert it to quaternion. Further, the zero-velocity update method was applied to reconstruct patients' walking trajectories. The combination of computed walking trajectory with pelvic and lower limb joint motion enables sketching the details of motion via a stickman that helps visualize and animate the walk and gait of a test subject. Five participants with above-knee (n = 2) and below-knee (n = 3) amputations were recruited for gait analysis. Kinematic parameters were evaluated during a walking test to assess joint alignment and overall gait characteristics. Our findings support the feasibility of employing simple algorithms to achieve accurate and precise joint angle estimation and gait parameters based on wireless inertial sensor data.


Assuntos
Amputados , Membros Artificiais , Humanos , Marcha , Caminhada , Amputação Cirúrgica , Joelho , Articulação do Joelho , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...