Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.777
Filtrar
1.
Anal Chem ; 96(14): 5625-5632, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38556980

RESUMO

The robust point-of-care platform for sensitive, multiplexed, and affordable detection of allergen-specific IgE (sIgE) is an urgent demand in component-resolved diagnostics. Here, we developed a microfluidic immunosensing platform based on a rolling circle amplification-assisted DNA dendrimer probe for sensitive detection of multiple sIgEs. The versatile multichannel microfluidic whole blood analytical device integrates cell filtration, recombinant antigen-modified magnetic enrichment, and DNA dendrimer probe-amplified signal transduction for portable on-chip analysis. Three sIgEs against common oyster allergens were simultaneously detected in blood samples by simple smartphone-based imaging without any pretreatment. The quantitative detection of multiple allergen-specific antibodies on the platform was achieved with limits of detection of less than 50 pg/mL, exhibiting superior sensitivity compared to most point-of-care testing. The detection results of 55 serum samples and 4 whole blood samples were 100% consistent with the ELISA results, confirming the accuracy and stability of our platform. Additionally, the reversible combination of hexahistidine6-tag and Ni-IMAC magbead was elegantly utilized on the immunosensing platform for desired reversibility. With the advantages of general applicability, high sensitivity, and reversibility, the DNA dendrimer-based microfluidic immunosensing platform provides great potential for the portable detection of immune proteins as a point-of-care platform in disease diagnostics and biological analysis.


Assuntos
Dendrímeros , Microfluídica , DNA/metabolismo , Sondas de DNA , Alérgenos , Imunoglobulina E
2.
Analyst ; 149(7): 2114-2121, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38426487

RESUMO

In this study, we innovatively synthesized bipyridine ruthenium cluster nanosheets (RuMOFNCs), a novel metal-organic framework material that exhibits both fluorescence and electrochemiluminescence. Gold nanoparticles (AuNPs) were anchored onto RuMOFNCs via bipyridine chelation, enhancing optical signals and creating sites for attaching biologically functional probes. We employed tetraferrocene-modified DNA probes, linked via gold-sulfur (Au-S) bonds, to construct a dual-mode fluorescence-electrochemiluminescence biosensor. This sensor, exploiting exonuclease III (Exo III)-mediated cyclic amplification, inhibits the electron transfer from RuMOFNC to tetraferrocene, resulting in amplified fluorescence and electrochemiluminescence signals. The sensor demonstrates exceptional sensitivity for detecting the BRAF gene, with fluorescence and electrochemiluminescence detection limits of 10.3 aM (range: 0.1 fM to 1 nM) and 3.1 aM (range: 1 aM to 10 pM), respectively. These capabilities are attributed to RuMOFNCs' luminescence properties, tetraferrocene's quenching effect, and the specificity of base pairing. This study's findings hold substantial promise for biomedical research and clinical diagnostics, particularly in precision medicine and early disease detection.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Ouro/química , Proteínas Proto-Oncogênicas B-raf , Fluorescência , Nanopartículas Metálicas/química , Sondas de DNA/química , Técnicas Biossensoriais/métodos , Limite de Detecção , Medições Luminescentes , Técnicas Eletroquímicas
3.
Anal Chem ; 96(11): 4597-4604, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38456210

RESUMO

DNA assemblies are commonly used in biosensing, particularly for the detection and imaging of microRNAs (miRNAs), which are biomarkers associated with tumor progression. However, the difficulty lies in the exploration of high-sensitivity analytical techniques for miRNA due to its limited presence in living cells. In this study, we introduced a DNA nanosphere (DS) enhanced catalytic hairpin assembly (CHA) system for the detection and imaging of intracellular miR-21. The single-stranded DNA with four palindromic portions and extending sequences at the terminal was annealed for assembling DS, which avoided the complex sequence design and high cost of long DNA strands. Benefiting from the multiple modification sites of DS, functional hairpins H1 (modified with Cy3 and BHQ2) and H2 were grafted onto the surface of DS for assembling DS-H1-H2 using a hybridization reaction. The DS-H1-H2 system utilized spatial confinement and the CHA reaction to amplify fluorescence signals of Cy3. This enabled highly sensitive and rapid detection of miR-21 in the range from 0.05 to 3.5 nM. The system achieved a limit of determination (LOD) of 2.0 pM, which was 56 times lower than that of the control CHA circuit with freedom hairpins. Additionally, the sensitivity was improved by 8 times. Moreover, DS-H1-H2 also showed an excellent imaging capability for endogenous miR-21 in tumor cells. This was due to enhanced cell internalization efficiency, accelerated reaction kinetics, and improved biostability. The imaging strategy was shown to effectively monitor the dynamic content of miR-21 in live cancer cells and differentiate various cells. In general, the simple nanostructure DS not only enhanced the detection and imaging capability of the conventional probe but also could be easily integrated with the reported DNA-free probe, indicating a wide range of potential applications.


Assuntos
Técnicas Biossensoriais , DNA Catalítico , MicroRNAs , Nanosferas , Neoplasias , MicroRNAs/genética , MicroRNAs/química , DNA/genética , DNA/química , Hibridização de Ácido Nucleico , Sondas de DNA/química , Técnicas Biossensoriais/métodos , Limite de Detecção
4.
Anal Chem ; 96(11): 4402-4409, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38457775

RESUMO

The ultrasensitive DNA methyltransferase (Dam MTase) assay is of high significance for biomedical research and clinical diagnosis because of its profound effect on gene regulation. However, detection sensitivity is still limited by shortcomings, including photobleaching and weak signal intensities of conventional fluorophores at low concentrations. Plasmonic nanostructures with ultrastrong electromagnetic fields and fluorescence enhancement capability that can overcome these intrinsic defects hold great potential for ultrasensitive bioanalysis. Herein, a silica-coated gold nanostars (Au NSTs@SiO2)-based plasmon-enhanced fluorescence (PEF) probe with 20 "hot spots" was developed for ultrasensitive detection of Dam MTase. Here, the Dam Mtase assay was achieved by detecting the byproduct PPi of the rolling circle amplification reaction. It is worth noting that, benefiting from the excellent fluorescence enhancement capability of Au NSTs originating from their 20 "hot spots", the detection limit of Dam Mtase was reduced by nearly 105 times. Moreover, the proposed Au NST-based PEF probe enabled versatile evaluation of Dam MTase inhibitors as well as endogenous Dam MTase detection in GW5100 and JM110 Escherichia coli cell lysates, demonstrating its potential in biomedical analysis.


Assuntos
Técnicas Biossensoriais , DNA Metiltransferases Sítio Específica (Adenina-Específica) , DNA Metiltransferases Sítio Específica (Adenina-Específica)/análise , Dióxido de Silício , Ouro/química , Metilases de Modificação do DNA , Escherichia coli , Corantes Fluorescentes/química , DNA , Sondas de DNA/química
5.
Biosens Bioelectron ; 253: 116185, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38457863

RESUMO

Mechanical forces play an important role in cellular communication and signaling. We developed in this study novel electrochemical DNA-based force sensors for measuring cell-generated adhesion forces. Two types of DNA probes, i.e., tension gauge tether and DNA hairpin, were constructed on the surface of a smartphone-based electrochemical device to detect piconewton-scale cellular forces at tunable levels. Upon experiencing cellular tension, the unfolding of DNA probes induces the separation of redox reporters from the surface of the electrode, which results in detectable electrochemical signals. Using integrin-mediated cell adhesion as an example, our results indicated that these electrochemical sensors can be used for highly sensitive, robust, simple, and portable measurements of cell-generated forces.


Assuntos
Técnicas Biossensoriais , Técnicas Biossensoriais/métodos , DNA/genética , Adesão Celular , Sondas de DNA , Integrinas/metabolismo
6.
Methods Mol Biol ; 2784: 215-225, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38502489

RESUMO

DNA fluorescence in situ hybridization (FISH) enables the visualization of chromatin architecture and the interactions between genomic loci at a single-cell level, complementary to genome-wide methods such as Hi-C. DNA FISH uses fluorescent-labeled DNA probes targeted to the loci of interest, allowing for the analysis of their spatial positioning and proximity with microscopy. Here, we describe an optimized experimental procedure for DNA FISH, from probe design and sample preparation through imaging and image quantification. This protocol can be readily applied to querying the spatial positioning of genomic loci of interest.


Assuntos
Cromatina , DNA , Hibridização in Situ Fluorescente/métodos , DNA/genética , Cromatina/genética , Cromossomos , Sondas de DNA/genética , Corantes Fluorescentes
7.
Biosensors (Basel) ; 14(3)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38534243

RESUMO

Protein-based microarrays are important tools for high-throughput medical diagnostics, offering versatile platforms for multiplex immunodetection. However, challenges arise in protein microarrays due to the heterogeneous nature of proteins and, thus, differences in their immobilization conditions. This article advocates DNA-directed immobilization (DDI) as a solution, emphasizing its rapid and cost-effective fabrication of biosensing platforms. Thiolated single-stranded DNA and its analogues, such as ZNA® and PNA probes, were used to immobilize model proteins (anti-CRP antibodies and SARS-CoV nucleoprotein). The study explores factors influencing DDI-based immunosensor performance, including the purity of protein-DNA conjugates and the stability of their duplexes with DNA and analogues. It also provides insight into backfilling agent type and probe surface density. The research reveals that single-component monolayers lack protection against protein adsorption, while mixing the probes with long-chain ligands may hinder DNA-protein conjugate anchoring. Conventional DNA probes offer slightly higher surface density, while ZNA® probes exhibit better binding efficiency. Despite no enhanced stability in different ionic strength media, the cost-effectiveness of DNA probes led to their preference. The findings contribute to advancing microarray technology, paving the way for new generations of DDI-based multiplex platforms for rapid and robust diagnostics.


Assuntos
Técnicas Biossensoriais , Imunoensaio , DNA , Sondas de DNA , Proteínas , Antígenos , Biologia
8.
Talanta ; 273: 125909, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38490020

RESUMO

The in vitro detection of circulating tumor cells (CTCs) has been proven as a vital method for early diagnosis and evaluation of cancer metastasis, since the existence and number fluctuation of CTCs have shown close correlation with clinical outcomes. However, it remains difficult and technically challenging to realize accurate CTCs detection, due to the rarity of CTCs in the blood samples with complex components. Herein, we reported a CTCs in vitro detection strategy, utilizing a loop amplification strategy based on DNA tetrahedron and nicking endonuclease reaction, as well as the anti-background interference based on lanthanide metal luminescence strategy. In this work, a detection system (ATDN-MLLPs) composed of an aptamer-functionalized tetrahedral DNA nanostructure (ATDN) and magnetic lanthanide luminescent particles (MLLPs) was developed. ATDN targeted the tumor cells via aptamer-antigen recognition and extended three hybridizable target DNA segments from the apex of a DNA tetrahedron to pair with probe DNA on MLLPs. Then, the nicking endonuclease (Nt.BbvCI) recognized the formed double-strand DNA and nicked the probe DNA to release the target DNA for recycling, and the released TbNps served as a high signal-to-noise ratio fluorescence signal source for CTCs detection. With a detection limit of 5 cells/mL, CTCs were selectively screened throughout a linear response range of low orders of magnitude. In addition, the ATDN-MLLPs system was attempted to detect possible existence of CTCs in biological samples in vitro.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Células Neoplásicas Circulantes , Humanos , Endonucleases/química , Luminescência , DNA/genética , DNA/química , Sondas de DNA/química , Metais , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico/métodos
9.
Talanta ; 273: 125978, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38521021

RESUMO

According to the characteristics of DNA programming, the cascaded nucleic acid amplification technology with larger output can overcome the problem of insufficient sensitivity of single nucleic acid amplification technology, and it combines the advantages of two or even multiple nucleic acid amplification technologies at the same time. In this work, a novel cascade signal amplification strategy with strand displacement amplification (SDA) and cascade hybridization chain reaction (HCR) was proposed for trace detection of hAAG and VEGF165. HAAG-induced SDA produced a large amount of S2 to open H2 on Polystyrene (PS) nanospheres, thereby triggering cascade HCR to form DNA dendritic nanostructures with rich fluorescence (FL) signal probes (565 nm). It could realize the amplification of FL signals for the detection of hAAG. Moreover, many doxorubicin (Dox) were loaded into the GC bases of DNA dendritic nanostructures, and its FL signal was effectively shielded. VEGF165 specifically bound to its aptamer to form G-quadruplex structures, which released Dox to produce a high FL signal (590 nm) for detection of VEGF165. This work developed a unique multifunctional DNA dendritic nanostructure fluorescence probe, and cleverly designed a new "On-off" switch strategy for sensitive trace detection of cancer markers.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Limite de Detecção , DNA/genética , DNA/química , Hibridização de Ácido Nucleico , Sondas de DNA/genética , Técnicas de Amplificação de Ácido Nucleico , Aptâmeros de Nucleotídeos/química , Corantes Fluorescentes/química
10.
Methods Mol Biol ; 2784: 271-284, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38502492

RESUMO

Genomic instability is an important biomarker in the progression of cervical carcinoma. DBD-FISH (DNA breakage detection-fluorescence in situ hybridization) is a sensitive method that detects strand breaks, alkali-labile sites, and incomplete DNA excision repair in cells of the cervical epithelium. This technique integrates the microgel immersion of cells from a vaginal lesion scraping and the DNA unwinding treatment with the capacity of FISH integrated into digital image analysis. Cells captured within an agarose matrix are lysed and submerged in an alkaline unwinding solution that generates single-stranded DNA motifs at the ends of internal DNA strand breaks. After neutralization, the microgel is dehydrated and the cells are incubated with DNA-labeled probes. The quantity of a hybridized probe at a target sequence corresponds to the measure of the single-stranded DNA produced during the unwinding step, which is equivalent to the degree of local DNA breakage. DNA damage does not show uniformly throughout the entire DNA of a cell; rather, it is confined to specific chromosomal sites. In this chapter, an overview of the technique is supplied, focusing on its ability for assessing the association between DNA damage in specific sequences and in the progressive stages of cervical carcinoma.


Assuntos
Carcinoma , Microgéis , Neoplasias do Colo do Útero , Feminino , Humanos , DNA , Dano ao DNA , Sondas de DNA/genética , DNA de Cadeia Simples , Hibridização in Situ Fluorescente/métodos , Neoplasias do Colo do Útero/genética , Neoplasias do Colo do Útero/patologia
11.
Sci Rep ; 14(1): 5229, 2024 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-38433255

RESUMO

In the Anthropocene, plastic pollution has become a new environmental biotope, the so-called plastisphere. In the oceans, nano- and micro-sized plastics are omnipresent and found in huge quantities throughout the water column and sediment, and their large surface area-to-volume ratio offers an excellent surface to which hydrophobic chemical pollutants (e.g. petrochemicals and POPs) can readily sorb to. Our understanding of the microbial communities that breakdown plastic-sorbed chemical pollutants, however, remains poor. Here, we investigated the formation of 500 nm and 1000 nm polystyrene (PS) agglomerations in natural seawater from a coastal environment, and we applied DNA-based stable isotope probing (DNA-SIP) with the 500 nm PS sorbed with isotopically-labelled phenanthrene to identify the bacterial members in the seawater community capable of degrading the hydrocarbon. Whilst we observed no significant impact of nanoplastic size on the microbial communities associated with agglomerates that formed in these experiments, these communities were, however, significantly different to those in the surrounding seawater. By DNA-SIP, we identified Arcobacteraceae, Brevundimonas, Comamonas, uncultured Comamonadaceae, Delftia, Sphingomonas and Staphylococcus, as well as the first member of the genera Acidiphilum and Pelomonas to degrade phenanthrene, and of the genera Aquabacterium, Paracoccus and Polymorphobacter to degrade a hydrocarbon. This work provides new information that feeds into our growing understanding on the fate of co-pollutants associated with nano- and microplastics in the ocean.


Assuntos
Comamonadaceae , Poluentes Ambientais , Microbiota , Fenantrenos , Microplásticos , Plásticos , Poliestirenos , Sondas de DNA , Isótopos , DNA
12.
J Am Chem Soc ; 146(10): 6516-6521, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38411013

RESUMO

Regulatory modules for controlling the kinetics of toehold-mediated strand displacement (TMSD) play critical roles in designing dynamic and dissipative DNA chemical reaction networks (CRNs) but are hardwired into sequence designs. Herein, we introduce antitoehold (At), a plug-and-play module for reversible and continuous tuning of TMSD kinetics by temporarily occupying the toehold domain via a metastable duplex and base stacking. We demonstrate that kinetic control can be readily activated or deactivated in real time for any TMSD by simply adding At or anti-At. Continuous tuning of TMSD kinetics can also be achieved by altering the concentration of At. Moreover, the simple addition of At could readily reprogram existing TMSDs into a pulse-generation DNA CRN with continuous tunability. Our At approach also offers a new way for engineering continuously tunable DNA hybridization probes, which may find practical uses for discriminating clinically important mutations. Because of the simplicity, we anticipate that At will find wide applications for engineering DNA CRNs with diverse dynamic and dissipative behaviors, and DNA hybridization probes with tunable affinity and selectivity.


Assuntos
DNA , DNA/química , Hibridização de Ácido Nucleico , Cinética , Sondas de DNA
13.
Biosens Bioelectron ; 251: 116065, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38330772

RESUMO

Lipid nanoparticles (LNPs) containing ionizable cationic lipids are proven delivery systems for therapeutic nucleic acids, such as small interfering RNA (siRNA). It is important to understand the relationship between the interior pH of LNPs and the pH of the external environment to understand LNP formulation and function. Here, we developed a simple and rapid approach for determining the pH of the LNP core using a pH-sensitive fluorescent dye-based DNA probe. LNP siRNA systems containing pH-responsive DNA probes (LNP-siRNA&DNA) were generated by rapid mixing of lipids in ethanol and pH 4 aqueous buffer containing siRNA and DNA probes. We demonstrated that DNA probes were readily encapsulated in LNP systems and were sequestered into an environment at a high concentration as evidenced by an inter-probe FRET signal. It was shown that the pH of LNP encapsulated probes closely follows the pH increase or decrease of the external environment. This indicates that the clinically approved LNP RNA systems with similar lipid compositions (e.g., Onpattro and Comirnaty) are highly permeable to protons and that the pH of the interior environment closely mirrors the external environment. The pH-dependent response of the probe in LNPs was also confirmed under buffer conditions at various pHs. Furthermore, we showed that the pH-sensitive DNA probe can be incorporated into LNP systems at levels that allow the pH response to be monitored at a single LNP level using convex lens-induced confinement (CLiC) confocal microscopy. Direct visualization of the internal pH of single particles with the fluorescent DNA probe was achieved by CLiC for LNP-siRNA&DNA systems formulated under both high and normal ionic strength conditions.


Assuntos
Técnicas Biossensoriais , Lipossomos , Nanopartículas , Corantes Fluorescentes , Lipídeos/química , Nanopartículas/química , RNA Interferente Pequeno/química , DNA , Sondas de DNA
14.
Talanta ; 272: 125777, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38364565

RESUMO

Tyramine signal amplification (TSA) has made its mark in immunoassay due to its excellent signal amplification ability and short reaction time, but its application in nucleic acid detection is still very limited. Herein, an ultrasensitive microRNA (miRNA) biosensor by coupling hybridization-initiated exonuclease I (Exo I) protection and TSA strategy was established. Target miRNA is complementarily hybridized to the biotin-modified DNA probe to form a double strand, which protects the DNA probe from Exo I hydrolysis. Subsequently, horseradish peroxidase (HRP) is attached to the duplex via the biotin-streptavidin reaction and catalyzes the deposition of large amounts of biotin-tyramine in the presence of hydrogen peroxide (H2O2), followed by the conjugation of signal molecule streptavidin-phycoerythrin (SA-PE), which generates an intense fluorescence signal upon laser excitation. This method gave broad linearity in the range of 0.1 fM - 10 pM, yielding a detection limit as low as 74 aM. An increase in sensitivity of 4 orders of magnitude was observed compared to the miRNA detection without TSA amplification. This biosensor was successfully applied to the determination of miR-21 in breast cancer cells and human serum. By further design of specific DNA probes and coupling with the Luminex xMAP technology, it could be easily extended to multiplex miRNA assay, which possesses great application potential in clinical diagnosis.


Assuntos
Técnicas Biossensoriais , Exodesoxirribonucleases , MicroRNAs , Humanos , MicroRNAs/genética , Biotina , Estreptavidina , Peróxido de Hidrogênio , Técnicas Biossensoriais/métodos , Sondas de DNA/genética , Tiramina , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico/métodos
15.
Nat Commun ; 15(1): 1027, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310092

RESUMO

Fluorescent in situ hybridization (FISH) is a powerful method for the targeted visualization of nucleic acids in their native contexts. Recent technological advances have leveraged computationally designed oligonucleotide (oligo) probes to interrogate > 100 distinct targets in the same sample, pushing the boundaries of FISH-based assays. However, even in the most highly multiplexed experiments, repetitive DNA regions are typically not included as targets, as the computational design of specific probes against such regions presents significant technical challenges. Consequently, many open questions remain about the organization and function of highly repetitive sequences. Here, we introduce Tigerfish, a software tool for the genome-scale design of oligo probes against repetitive DNA intervals. We showcase Tigerfish by designing a panel of 24 interval-specific repeat probes specific to each of the 24 human chromosomes and imaging this panel on metaphase spreads and in interphase nuclei. Tigerfish extends the powerful toolkit of oligo-based FISH to highly repetitive DNA.


Assuntos
DNA , Sequências Repetitivas de Ácido Nucleico , Humanos , Hibridização in Situ Fluorescente/métodos , DNA/genética , Sequências Repetitivas de Ácido Nucleico/genética , Sondas de Oligonucleotídeos/genética , Sondas de DNA/genética , Oligonucleotídeos/genética
16.
Brief Bioinform ; 25(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38305453

RESUMO

Target enrichment sequencing techniques are gaining widespread use in the field of genomics, prized for their economic efficiency and swift processing times. However, their success depends on the performance of probes and the evenness of sequencing depth among each probe. To accurately predict probe coverage depth, a model called Deqformer is proposed in this study. Deqformer utilizes the oligonucleotides sequence of each probe, drawing inspiration from Watson-Crick base pairing and incorporating two BERT encoders to capture the underlying information from the forward and reverse probe strands, respectively. The encoded data are combined with a feed-forward network to make precise predictions of sequencing depth. The performance of Deqformer is evaluated on four different datasets: SNP panel with 38 200 probes, lncRNA panel with 2000 probes, synthetic panel with 5899 probes and HD-Marker panel for Yesso scallop with 11 000 probes. The SNP and synthetic panels achieve impressive factor 3 of accuracy (F3acc) of 96.24% and 99.66% in 5-fold cross-validation. F3acc rates of over 87.33% and 72.56% are obtained when training on the SNP panel and evaluating performance on the lncRNA and HD-Marker datasets, respectively. Our analysis reveals that Deqformer effectively captures hybridization patterns, making it robust for accurate predictions in various scenarios. Deqformer leads to a novel perspective for probe design pipeline, aiming to enhance efficiency and effectiveness in probe design tasks.


Assuntos
Aprendizado Profundo , RNA Longo não Codificante , Sondas de DNA/genética , Hibridização de Ácido Nucleico , Genômica
17.
Angew Chem Int Ed Engl ; 63(13): e202316434, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38192021

RESUMO

Aptamer-based probes are pivotal components in various sensing strategies, owing to their exceptional specificity and versatile programmable structure. Nevertheless, numerous aptamer-based probes usually offer only a single function, limiting their capacity to meet the diverse requirements of multi-faceted sensing systems. Here, we introduced supersandwich DNA probes (SSW-DNA), designed and modified on the outer surface of nanochannels with hydrophobic inner walls, enabling dual functionality: qualitative detection for on-site analysis and quantitative detection for precise analysis. The fragmented DNAs resulting from the target recognition, are subsequently identified through lateral flow assays, enabling robust on-site qualitative detection of microcystin-LR with an impressively low limit of detection (LOD) at 0.01 µg/L. Meanwhile, the nanochannels enable highly sensitive quantification of microcystin-LR through the current analysis, achieving an exceptionally low LOD at 2.5×10-7  µg/L, with a broad dynamic range spanning from 1×10-6 to 1×102  µg/L. Furthermore, the process of target recognition introduces just a single potential error propagation, which reduces the overall risk of errors during the entire qualitative and quantitative detection process. This sensing strategy broadens the scope of applications for aptamer-based composite probes, holding promising implications across diverse fields, such as medical diagnosis, food safety, and environmental protection.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Sondas de DNA , DNA , Limite de Detecção
18.
J Biol Chem ; 300(3): 105676, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38278326

RESUMO

Infectious diseases are one of the world's leading causes of morbidity. Their rapid spread emphasizes the need for accurate and fast diagnostic methods for large-scale screening. Here, we describe a robust method for the detection of pathogens based on microscale thermophoresis (MST). The method involves the hybridization of a fluorescently labeled DNA probe to a target RNA and the assessment of thermophoretic migration of the resulting complex in solution within a 2 to 30-time window. We found that the thermophoretic migration of the nucleic acid-based probes is primarily determined by the fluorescent molecule used, rather than the nucleic acid sequence of the probe. Furthermore, a panel of uniformly labeled probes that bind to the same target RNA yields a more responsive detection pattern than a single probe, and moreover, can be used for the detection of specific pathogen variants. In addition, intercalating agents (ICA) can be used to alter migration directionality to improve detection sensitivity and resolving power by several orders of magnitude. We show that this approach can rapidly diagnose viral SARS-CoV2, influenza H1N1, artificial pathogen targets, and bacterial infections. Furthermore, it can be used for anti-microbial resistance testing within 2 h, demonstrating its diagnostic potential for early pathogen detection.


Assuntos
Ensaios de Triagem em Larga Escala , Técnicas Microbiológicas , Técnicas de Diagnóstico Molecular , Hibridização de Ácido Nucleico , RNA , Sondas de DNA , Vírus da Influenza A Subtipo H1N1/genética , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Técnicas Microbiológicas/métodos , Técnicas Microbiológicas/normas , Ensaios de Triagem em Larga Escala/métodos , Ensaios de Triagem em Larga Escala/normas , RNA/análise , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Viroses/diagnóstico , Infecções Bacterianas/diagnóstico , Linhagem Celular Tumoral , Humanos
19.
RNA ; 30(4): 448-462, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38282416

RESUMO

This report describes a chemiluminescence-based detection method for RNAs on northern blots, designated Chemi-Northern. This approach builds on the simplicity and versatility of northern blotting, while dispensing of the need for expensive and cumbersome radioactivity. RNAs are first separated by denaturing gel electrophoresis, transferred to a nylon membrane, and then hybridized to a biotinylated RNA or DNA antisense probe. Streptavidin conjugated with horseradish peroxidase and enhanced chemiluminescence substrate are then used to detect the probe bound to the target RNA. Our results demonstrate the versatility of this method in detecting natural and engineered RNAs expressed in cells, including messenger and noncoding RNAs. We show that Chemi-Northern detection is sensitive and fast, detecting attomole amounts of RNA in as little as 1 sec, with high signal intensity and low background. The dynamic response displays excellent linearity. Using Chemi-Northern, we measure the reproducible, statistically significant reduction of mRNA levels by human sequence-specific RNA-binding proteins, PUM1 and PUM2. Additionally, we measure the interaction of the poly(A) binding protein, PABPC1, with polyadenylated mRNA. Thus, the Chemi-Northern method provides a versatile, simple, and cost-effective method to enable researchers to analyze expression, processing, binding, and decay of RNAs.


Assuntos
Proteínas de Ligação a RNA , RNA , Humanos , Northern Blotting , RNA Mensageiro/metabolismo , RNA/química , Sondas de Oligonucleotídeos , Sequência de Bases , Proteínas de Ligação a RNA/genética , Proteínas de Ligação a RNA/metabolismo , Sondas de DNA
20.
Analyst ; 149(3): 968-974, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38197474

RESUMO

DNA nanotechnology deals with the design of non-naturally occurring DNA nanostructures that can be used in biotechnology, medicine, and diagnostics. In this study, we introduced a nucleic acid five-way junction (5WJ) structure for direct electrochemical analysis of full-length biological RNAs. To the best of our knowledge, this is the first report on the interrogation of such long nucleic acid sequences by hybridization probes attached to a solid support. A hairpin-shaped electrode-bound oligonucleotide hybridizes with three adaptor strands, one of which is labeled with methylene blue (MB). The four strands are combined into a 5WJ structure only in the presence of specific DNA or RNA analytes. Upon interrogation of a full-size 16S rRNA in the total RNA sample, the electrode-bound MB-labeled 5WJ association produces a higher signal-to-noise ratio than electrochemical nucleic acid biosensors of alternative design. This advantage was attributed to the favorable geometry on the 5WJ nanostructure formed on the electrode's surface. The 5WJ biosensor is a cost-efficient alternative to the traditional electrochemical biosensors for the analysis of nucleic acids due to the universal nature of both the electrode-bound and MB-labeled DNA components.


Assuntos
Técnicas Biossensoriais , Ácidos Nucleicos , RNA Ribossômico 16S , DNA/química , Sondas de DNA/química , Nanotecnologia , Técnicas Eletroquímicas , Hibridização de Ácido Nucleico , Azul de Metileno/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...