Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 18.205
Filtrar
3.
JMIR Med Educ ; 10: e52679, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38619866

RESUMO

Despite the increasing relevance of statistics in health sciences, teaching styles in higher education are remarkably similar across disciplines: lectures covering the theory and methods, followed by application and computer exercises in given data sets. This often leads to challenges for students in comprehending fundamental statistical concepts essential for medical research. To address these challenges, we propose an engaging learning approach-DICE (design, interpret, compute, estimate)-aimed at enhancing the learning experience of statistics in public health and epidemiology. In introducing DICE, we guide readers through a practical example. Students will work in small groups to plan, generate, analyze, interpret, and communicate their own scientific investigation with simulations. With a focus on fundamental statistical concepts such as sampling variability, error probabilities, and the construction of statistical models, DICE offers a promising approach to learning how to combine substantive medical knowledge and statistical concepts. The materials in this paper, including the computer code, can be readily used as a hands-on tool for both teachers and students.


Assuntos
Bioestatística , Treinamento por Simulação , Humanos , Biometria , Estudantes , Saúde Pública
4.
BMC Oral Health ; 24(1): 436, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600486

RESUMO

The anatomy of furcation favours the bacterial retention and makes periodontal debridement as well as oral hygiene procedures difficult. Teeth that have lost attachment to a level of the furcation are said to have a furcal invasion or furcation involved.Involvement of furcation in a multi-rooted tooth poses a very different type of clinical situation in terms of establishment of diagnosis, determination of prognosis and of course planning the treatment modality.The present study was carried out on 200 selected extracted human first and second permanent molar teeth based on a predefined criteria. Teeth with prosthetic crowns, fused or fractured roots, those not fully developed, grossly carious or heavily restored at the cementoenamel junction (CEJ) were excluded from the study. The morphology of the root trunk was recorded by measuring various dimensions of the root trunk,including furcal angle and root trunk volume was calculated by using a custom made special apparatus. The furcation areas were debrided with different types of curettes in the market in order to see how best the instrument could be maneuvered in the furcation area. The data so obtained was statistically analysed using SPSS version 22. The highest root trunk volume and the longest root trunk length were found to be in the maxillary second molar. 48.60% furcations didn't allow instrument engagementof furcation area with standard area specific curettes. The proposal of inclusion of root trunk length (mm) is suggested in addition to classification of FI to have assess prognosis and appropriate treatment for of the involved tooth.


Assuntos
Defeitos da Furca , Raiz Dentária , Humanos , Raiz Dentária/anatomia & histologia , Dente Molar/cirurgia , Dente Molar/anatomia & histologia , Colo do Dente , Prognóstico , Biometria , Defeitos da Furca/cirurgia , Defeitos da Furca/diagnóstico
5.
Sensors (Basel) ; 24(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38610340

RESUMO

In this study, an internal fingerprint-guided epidermal thickness of fingertip skin is proposed for optical image encryption based on optical coherence tomography (OCT) combined with U-Net architecture of a convolutional neural network (CNN). The epidermal thickness of fingertip skin is calculated by the distance between the upper and lower boundaries of the epidermal layer in cross-sectional optical coherence tomography (OCT) images, which is segmented using CNN, and the internal fingerprint at the epidermis-dermis junction (DEJ) is extracted based on the maximum intensity projection (MIP) algorithm. The experimental results indicate that the internal fingerprint-guided epidermal thickness is insensitive to pressure due to normal correlation coefficients and the encryption process between epidermal thickness maps of fingertip skin under different pressures. In addition, the result of the numerical simulation demonstrates the feasibility and security of the encryption scheme by structural similarity index matrix (SSIM) analysis between the original image and the recovered image with the correct and error keys decryption, respectively. The robustness is analyzed based on the SSIM value in three aspects: different pressures, noise attacks, and data loss. Key randomness is valid by the gray histograms, and the average correlation coefficients of adjacent pixelated values in three directions and the average entropy were calculated. This study suggests that the epidermal thickness of fingertip skin could be seen as important biometric information for information encryption.


Assuntos
Epiderme , Dedos , Estudos Transversais , Epiderme/diagnóstico por imagem , Dedos/diagnóstico por imagem , Algoritmos , Biometria
6.
Sensors (Basel) ; 24(7)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38610479

RESUMO

In recent years, the advancement of generative techniques, particularly generative adversarial networks (GANs), has opened new possibilities for generating synthetic biometric data from different modalities, including-among others-images of irises, fingerprints, or faces in different representations. This study presents the process of generating synthetic images of human irises, using the recent StyleGAN3 model. The novelty presented in this work consists in producing generated content in both Cartesian and polar coordinate representations, typically used in iris recognition pipelines, such as the foundational work proposed by John Daugman, but hitherto not used in generative AI experiments. The main objective of this study was to conduct a qualitative analysis of the synthetic samples and evaluate the iris texture density and suitability for meaningful feature extraction. During this study, a total of 1327 unique irises were generated, and experimental results carried out using the well-known OSIRIS open-source iris recognition software and the equivalent software, wordlcoin-openiris, newly published at the end of 2023 to prove that (1) no "identity leak" from the training set was observed, and (2) the generated irises had enough unique textural information to be successfully differentiated between both themselves and between them and real, authentic iris samples. The results of our research demonstrate the promising potential of synthetic iris data generation as a valuable tool for augmenting training datasets and improving the overall performance of iris recognition systems. By exploring the synthetic data in both Cartesian and polar representations, we aim to understand the benefits and limitations of each approach and their implications for biometric applications. The findings suggest that synthetic iris data can significantly contribute to the advancement of iris recognition technology, enhancing its accuracy and robustness in real-world scenarios by greatly augmenting the possibilities to gather large and diversified training datasets.


Assuntos
Biometria , Iris , Humanos , Reconhecimento Psicológico , Software , Tecnologia
7.
J Refract Surg ; 40(4): e218-e228, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593257

RESUMO

PURPOSE: To assess agreement between a new aberrometer (Osiris-T; CSO) employing pyramid wavefront sensor technique and Scheiner-Smirnov aberrometer (OPD-Scan III; Nidek) on measuring ocular, corneal, and internal aberrations in healthy participants. METHODS: The measurements were conducted three times consecutively by an experienced examiner. The total root mean square (RMS) aberrations, higher order aberration RMS, coma Z3±1, trefoil Z3±3, spherical aberration Z40, and astigmatism II Z4±2 up to 7th order were exported in both 4-and 6-mm pupil zones. The parameters between the two devices were statistically compared using the paired t-test, and the differences assessed with Bland-Altman plots and 95% limits of agreement. RESULTS: This prospective study included 70 right eyes of 70 healthy participants with an average age of 25.94 ± 6.59 years (range: 18 to 47 years). The mean difference in the two devices ranged from 0.01 µm for astigmatism II Z4±2 to 0.63 µm for total RMS in 4 mm and from 0.01 to 1.41 µm in 6-mm pupil size. The Bland-Altman analysis of ocular, corneal, and internal aberrations indicated high agreement between the two devices and the maximum absolute values for 95% limits of agreement ranged from 0.03 to 1.06 µm for 4-mm pupil diameters and 0.12 to 1.13 µm for 6-mm pupil diameters. CONCLUSIONS: The newly developed pyramid wavefront sensor technique aberrometer demonstrated a high agreement with a Scheiner-Smirnov aberrometer when measuring ocular, corneal, and internal aberrations in healthy participants. Thus, the two aberrometers may be considered interchangeable for clinical applications. [J Refract Surg. 2024;40(4):e218-e228.].


Assuntos
Astigmatismo , Humanos , Adulto Jovem , Adulto , Estudos Prospectivos , Córnea , Pupila , Biometria , Topografia da Córnea , Refração Ocular
8.
Sci Rep ; 14(1): 8305, 2024 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594402

RESUMO

To investigate the associations between corneal curvature (CC) and other anterior segment biometrics in young myopic adults. In this retrospective multi-center study, 7893 young myopic adults were included. CC and other anterior segment biometrics were measured by Scheimpflug imaging (Pentacam). CC was defined as SimK at central 3 mm area, and other anterior segment biometrics included white-to-white corneal diameter (WTW), central corneal thickness (CCT), corneal volume (CV) at 3 mm, 5 mm, and 7 mm area, anterior corneal astigmatism (ACA), posterior corneal astigmatism (PCA), anterior corneal eccentricity (ACE) and asphericity (ACAP), posterior corneal eccentricity (PCE) and asphericity (PCAP), anterior chamber depth (ACD), and anterior chamber volume (ACV). Univariate regression analyses were used to assess the associations between CC and other anterior segment biometrics, and multivariate regression analyses were further performed to adjusted for age, gender and spherical equivalent. CC was higher in patients of female gender and higher myopia (all P < 0.05). Eyes in higher CC quartiles had lower WTW, thinner CCT, lower CV at 3 mm and 5 mm, lower ACD, and lower ACV (all P < 0.001), but had larger ACA, larger PCA, less PCE and less PCAP (all P < 0.001), compared to eyes in lower CC quartiles. The trends of CV at 7 mm, ACE and ACAP were inconsistent in different CC quartiles. After adjusting for age, gender and spherical equivalent with multivariate linear regression, CC was positively correlated to CV at 7 mm (ßs = 0.069), ACA (ßs = 0.194), PCA (ßs = 0.187), ACE (ßs = 0.072), PCAP (ßs = 0.087), and ACD (ßs = 0.027) (all P < 0.05), but was negatively correlated to WTW (ßs = - 0.432), CCT (ßs = - 0.087), CV-3 mm (ßs = - 0.066), ACAP (ßs = - 0.043), PCE (ßs = - 0.062), and ACV (ßs = - 0.188) (all P < 0.05). CC was associated with most of the other anterior segment biometrics in young myopic adults. These associations are important for better understanding of the interactions between different anterior segment structures in young myopic patients, and are also useful for the exploration of the pathogenesis of myopia.


Assuntos
Astigmatismo , Doenças da Córnea , Miopia , Adulto , Feminino , Humanos , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Astigmatismo/patologia , Biometria , Córnea/patologia , Doenças da Córnea/patologia , Miopia/patologia , Estudos Retrospectivos
9.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593262

RESUMO

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Assuntos
Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/diagnóstico , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Facoemulsificação/métodos , Óptica e Fotônica , Refração Ocular , Biometria/métodos
10.
Comput Biol Med ; 173: 108333, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522250

RESUMO

Nowadays, the use of biological signals as a criterion for identity recognition has gained increasing attention from various organizations and companies. Therefore, it has become crucial to have a biometric identity recognition method that is fast and accurate. In this paper, we propose a linear electrocardiogram (ECG) data preprocessing algorithm based on Kalman filters for rapid noise data filtering (wavelet transform filtering algorithm). Additionally, we introduce a generative network model called Data Generation Strategy Network (DRCN) based on generative networks. The DRCN is employed to augment training samples for convolutional classification networks, ultimately improving the classification performance of the model. Through the final experiments, our method successfully reduced the average misidentification rate of ECG-based identity recognition to 2.5%, and achieved an average recognition rate of 98.7% for each category, significantly surpassing previous achievements. In the future, this method is expected to be widely applied in the field of ECG-based identity recognition.


Assuntos
Algoritmos , Processamento de Sinais Assistido por Computador , Análise de Ondaletas , Biometria , Eletrocardiografia/métodos
11.
Sci Rep ; 14(1): 6787, 2024 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514709

RESUMO

The aim of this study was to investigate the anatomical and physiological ocular parameters in adolescents with myopia and to examine the relations between refractive error (SER), ocular biometry, body size and flexibility parameters in myopic adolescents. A cross-sectional study of 184 myopic adolescents, aged 15 to 19 years was conducted. Refractive error and corneal curvature measures of the eye were evaluated using an autorefractometer under cycloplegia. Central corneal thickness was determined by contact pachymetry. The ocular axial length, anterior and vitreous chamber depth, and lens thickness were measured using A-scan biometry ultrasonography. Height and body weight were measured according to a standardized protocol. Body mass index (BMI) was subsequently calculated. Beighton scale was used to measure joint flexibility. Body stature was positively correlated with ocular axial length (r = 0.39, p < 0.001) and vitreous chamber depth (r = 0.37, p < 0.001). There was a negative correlation between height and SER (r = - 0.46; p < 0.001). Beighton score and body weight had weak positive correlations with axial length and vitreous chamber depth, and a weak negative correlation with SER. A significantly more negative SER was observed in the increased joint mobility group (p < 0.05; U = 5065.5) as compared to normal joint mobility group: mean - 4.37 ± 1.85 D (median - 4.25; IQR - 6.25 to - 3.25 D) and mean - 3.72 ± 1.66 D (median - 3.50; IQR - 4.75 to - 2.25 D) respectively. There was a strong association between height and axial length, as well as SER. Higher degree of myopia significantly correlated with greater Beighton score (increased joint mobility).


Assuntos
Miopia , Erros de Refração , Adolescente , Humanos , Estudos Transversais , Olho/diagnóstico por imagem , Biometria , Peso Corporal , Segmento Anterior do Olho , Refração Ocular , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/anatomia & histologia , Comprimento Axial do Olho/diagnóstico por imagem
12.
J Refract Surg ; 40(3): e156-e163, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466761

RESUMO

PURPOSE: To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction. METHODS: This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and cataract surgery. The primary outcome measures were cumulative distribution of absolute refractive prediction error, absolute refractive prediction error, and refractive prediction error. These parameters were estimated post-hoc using the Camellin-Calossi, Shammas, Haigis-L, Barrett True-K with or without history, Masket, and Modified Masket formulas and their averages starting from biometric data, clinical records, postoperative refraction, and intraocular lens power implanted. RESULTS: Seventy-seven eyes from 77 patients were included. The Camellin-Calossi, Shammas, Haigis-L, Barrett True-K No History, Masket, Modified Masket, and Barrett True-K formulas showed a median absolute refractive error (interquartile range) of 0.25 (0.53), 0.51 (0.56), 0.44 (0.65), 0.45 (0.59), 0.40 (0.61), 0.60 (0.70), and 0.55 (0.76), respectively. The proportion of eyes with an absolute refractive error of ±0.25, 0.50, 0.75, 1.00, 1.50, and 2.00 diopters (D) for the Camellin-Calossi formula was 54.5%, 72.7%, 85.7%, 92.2%, 98.7%, and 100%, respectively. The cumulative distribution of the Camellin-Calossi formula showed the best qualitative performances when compared to the others. A statistically significant difference was identified with all of the others except the Haigis-L using a threshold of 0.25, with the Shammas, Modified Masket, and Barrett True-K at a threshold of 0.50 D and the Barrett True-K and Modified Masket at a threshold of 1.00 D. CONCLUSIONS: The Camellin-Calossi formula is a valid option for intraocular lens power calculation in eyes with prior myopic laser vision correction. [J Refract Surg. 2024;40(3):e156-e163.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lentes Intraoculares , Miopia , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Refração Ocular , Miopia/cirurgia , Biometria , Lasers , Óptica e Fotônica
13.
J Refract Surg ; 40(3): e182-e194, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466762

RESUMO

PURPOSE: To provide an up-to-date review of the agreement in automated white-to-white (WTW) measurement between the latest topographic and biometric devices. METHODS: In this systematic review, PubMed, Web of Science, and Scopus databases were searched for articles published between 2017 and 2023, focusing on WTW agreement studies on adult, virgin eyes, with or without cataract and no other ocular comorbidities. Studies evaluating WTW measurements performed with autokeratometers, manual calipers, or manual image analysis were excluded. When available, the following metrics for the agreement of WTW measurements between pairs of devices were included: mean difference ± standard deviation, 95% limits of agreement (LoA), LoA width, 95% confidence interval (95 CI%), and intraclass correlation coefficient (ICC). RESULTS: Forty-one studies, covering comparisons for 19 devices, were included. Altogether, 81 paired comparisons were performed for 4,595 eyes of 4,002 individuals. The mean difference in WTW measurements between devices ranged from 0.01 mm up to 0.96 mm, with varying CI. The 95% LoA width ranged from 0.31 to 2.45 mm (median: 0.65 mm). The majority of pairwise comparisons reported LoA wider than 0.5 mm, a clinically significant value for phakic intraocular lens sizing. CONCLUSIONS: Nearly all analyzed studies demonstrated the lack of interchangeability of the WTW parameter. The corneal diameter, assessed by means of grayscale en-face image analysis, tended to demonstrate the lowest agreement among devices compared to other measured biometric parameters. [J Refract Surg. 2024;40(3):e182-e194.].


Assuntos
Córnea , Lentes Intraoculares Fácicas , Adulto , Humanos , Topografia da Córnea/métodos , Câmara Anterior , Biometria/métodos , Reprodutibilidade dos Testes
14.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466765

RESUMO

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Assuntos
Cristalino , Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/métodos , Miopia/cirurgia , Acomodação Ocular , Câmara Anterior/diagnóstico por imagem , Pseudofacia/cirurgia , Tomografia de Coerência Óptica , Biometria
15.
PLoS One ; 19(3): e0286087, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38437206

RESUMO

The fundamental technology behind bitcoin, known as blockchain, has been studied and used in a variety of industries especially in finance. The security of blockchain is extremely important as it will affects the assets of the clients as well as it is the lifeline feature of the entire system that needs to be guaranteed. Currently, there is a lack of a methodical approach to guarantee the security and dependability of the private key during its whole life. Furthermore, there is no quick, easy, or secure way to create the encryption key. A biometric-based private key encryption and management framework (BPKEM) for blockchain is proposed not only to solve the private key lifecycle manag- ement problem, but also it maintains compatibility with existing blockchain systems. For the problem of private key encryption, a biometric-based stable key generation method is proposed. By using the relative invariance between facial and fingerprint feature points, this measure can convert feature points into stable and distinguishable descriptors, then using a reusable fuzzy extractor to create a stable key. The correct- ness and efficiency of the newly proposed biometric-based blockchain encryption tech- nique in this paper has been validated in the experiments.


Assuntos
Blockchain , Humanos , Biometria , Face , Indústrias , Manutenção
16.
BMC Ophthalmol ; 24(1): 143, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549060

RESUMO

AIM: To investigate the correlation of angles α and κ with the refractive and biological parameters in children. METHODS: This case-series study included 438 eyes of 219 children (males/females = 105/114, age: 3-15 years). Ocular biometric parameters, including axial length, corneal radius of curvature (CR), white-to-white distance (WTW), angle κ and angle α, were measured using IOL Master 700; auto-refraction were assessed under cycloplegia. The eyes were assigned to different groups based on CR, WTW, and gender to compare the angles α and κ, and analyze the correlations between the differences of biological parameters on angles α and κ. RESULTS: The means of axial length, CR, WTW, angle α, and angle κ were 23.24 ± 1.14 mm, 7.79 ± 0.27 mm, 11.68 ± 0.41 mm, 0.45 ± 0.25 mm, and 0.27 ± 0.22 mm, respectively. Angle α was correlated with CR and WTW (fixed effect coefficient [FEC] = 0.237, p = 0.015; FEC = -0.109, p = 0.003; respectively), and angle κ also correlated with CR and WTW (FEC = 0.271, p = 0.003; FEC = -0.147, p < 0.001, respectively). Comparing subgroups, the large CR and small WTW group had larger angles α (0.49 ± 0.27 vs. 0.41 ± 0.21, p < 0.001; 0.46 ± 0.27 vs. 0.44 ± 0.21, p < 0.05, respectively) and κ (0.29 ± 0.25 vs. 0.24 ± 0.15, p < 0.01; 0.29 ± 0.25 vs. 0.26 ± 0.19, p < 0.05, respectively). The differences in interocular angles α and κ showed correlation with interocular WTW (r = - 0.255, p < 0.001; r = - 0.385, p < 0.001). Eyes with smaller WTW tended to have larger angle κ (0.28 ± 0.27 vs. 0.25 ± 0.15, p < 0.05). CONCLUSION: The size of angle α/κ may be correlated to CR and WTW, and a larger WTW eye may suggest a smaller angle κ compared with the fellow eye.


Assuntos
Presbiopia , Refração Ocular , Criança , Humanos , Feminino , Masculino , Pré-Escolar , Adolescente , Testes Visuais , Córnea , Biometria , Comprimento Axial do Olho
17.
Int Ophthalmol ; 44(1): 160, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536560

RESUMO

PURPOSE: To compare anterior chamber angle (ACA) parameters measured by Anterior Segment Optical Coherence Tomography (ASOCT) and biometric parameters measured by Swept-Source (SS) OCT-based biometry among patients with suspected occludable angles and open angles. METHODS: An analytical, cross-sectional study was performed on subjects attending our ophthalmology outpatient department with suspected occludable angles (van Herick grades 0, 1, and 2) in group 1, and with open angles (van Herick grades 3 and 4) in group 2. Each subject underwent a complete ophthalmic examination to exclude any intraocular pathology like cataract. We recruited 128 eyes of 64 subjects, 34 in group 1 and 30 in group 2. Each eye was henceforth subjected to ASOCT (Spectralis, Heidelberg Engineering, Heidelberg) and SS-OCT-based optical biometry (IOL Master 700, Carl Zeiss Meditec AG). Anatomical parameters were recorded and compared between the two groups. RESULTS: The main outcome measures of the study included nine ASOCT parameters (central corneal thickness [CCT], lens vault, AOD750, ACA, TISA750 [nasal and temporal], and ACW) and five optical biometric parameters (CCT, ACD, WTW, LT, and axial length). We found a significant difference (p < 0.05) among all the anatomical parameters between the two groups, except CCT which was not significantly different (p = 0.297). CONCLUSIONS: ASOCT and SSOCT biometry overcome the challenges of gonioscopy and allow screening for angle closure disease in otherwise normal subjects. ASOCT may serve as an alternative to gonioscopy as it clearly separates occludable angles from open angles in a non-invasive and objective manner.


Assuntos
Glaucoma de Ângulo Fechado , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Pressão Intraocular , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/patologia , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Biometria , Gonioscopia , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia
18.
BMC Ophthalmol ; 24(1): 126, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504225

RESUMO

BACKGROUND: This study evaluates the impact of corneal power on the accuracy of 14 newer intraocular lens (IOL) calculation formulas in cataract surgery. The aim is to assess how these formulas perform across different corneal curvature ranges, thereby guiding more precise IOL selection. METHODS: In this retrospective case series, 336 eyes from 336 patients who underwent cataract surgery were studied. The cohort was divided into three groups according to preoperative corneal power. Key metrics analyzed included mean prediction error (PE), standard deviation of PE (SD), mean absolute prediction error (MAE), median absolute error (MedAE), and the percentage of eyes with PE within ± 0.25 D, 0.50 D, ± 0.75 D, ± 1.00 D and ± 2.00 D. RESULTS: In the flat K group (Km < 43 D), VRF-G, Emmetropia Verifying Optical Version 2.0 (EVO2.0), Kane, and Hoffer QST demonstrated lower SDs (± 0.373D, ± 0.379D, ± 0.380D, ± 0.418D, respectively) compared to the VRF formula (all P < 0.05). EVO2.0 and K6 showed significantly different SDs compared to Barrett Universal II (BUII) (all P < 0.02). In the medium K group (43 D ≤ Km < 46 D), VRF-G, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS recorded lower MAEs (0.307D to 0.320D) than Olsen (OLCR) and Castrop (all P < 0.03), with RBF3.0 having the second lowest MAE (0.309D), significantly lower than VRF and Olsen (OLCR) (all P < 0.05). In the steep K group (Km ≥ 46D), RBF3.0, K6, and Kane achieved significantly lower MAEs (0.279D, 0.290D, 0.291D, respectively) than Castrop (all P < 0.001). CONCLUSIONS: The study highlights the varying accuracy of newer IOL formulas based on corneal power. VRF-G, EVO2.0, Kane, K6, and Hoffer QST are highly accurate for flat corneas, while VRF-G, RBF3.0, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS are recommended for medium K corneas. In steep corneas, RBF3.0, K6, and Kane show superior performance.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Estudos Retrospectivos , Córnea , Olho Artificial , Biometria , Refração Ocular , Óptica e Fotônica , Comprimento Axial do Olho
19.
Optom Vis Sci ; 101(3): 157-163, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38546757

RESUMO

SIGNIFICANCE: Validation of new biometry instruments against the gold standard and establishing repeatability are important before being utilized for clinical and research applications. PURPOSE: This study aimed to investigate intersession repeatability of the MYAH optical biometer and corneal topographer and examine agreement with the Lenstar LS900 optical biometer in healthy young adults. METHODS: Forty participants (mean age, 25.2 ± 3.1 years) presented for two visits, 2 to 4 days apart. At each visit, measurements for right eyes were collected with the MYAH and Lenstar LS 900 and included axial length, corneal power, white-to-white distance, and pupil diameter. Bland-Altman analysis was used to assess the intrasession agreement between the MYAH and Lenstar for each parameter and intersession repeatability for the two devices. For each device, coefficient of variation and intraclass correlation coefficient were calculated, and paired t tests between visits were performed to assess intersession repeatability. RESULTS: Good agreement (mean difference [95% limits of agreement]) between the MYAH and Lenstar was found for axial length (-0.01 [-0.07 to 0.04] mm), corneal power (-0.02 D [-0.15 to 0.19 d]), white-to-white distance (-0.13 [-0.43 to 0.17] mm), and pupil diameter (-0.27 [-0.79 to 1.33] mm). The limits of agreement, coefficient of variations, and intraclass correlation coefficients for MYAH-measured parameters were -0.04 to 0.04, 0.06%, and >0.99 for axial length; -0.24 to 0.19, 0.18%, and >0.99 for corneal power; -1.05 to 1.15, 0.57%, and 0.96 for white-to-white distance; and -0.17 to 0.21, 7.0%, and 0.76 for pupil diameter, with no significant difference between visits (p>0.05 for all), indicating good intersession repeatability. Similar intersession repeatability was also noted for Lenstar. CONCLUSIONS: Findings show good intersession repeatability of the MYAH and good agreement with the Lenstar for axial length, corneal power, and white-to-white distance in young adults. Pupil diameter was more variable, likely due to the dynamic nature of the pupil. This study provides validation and supports the use of the MYAH for ocular biometry.


Assuntos
Biometria , Córnea , Adulto Jovem , Humanos , Adulto , Pupila
20.
BMC Ophthalmol ; 24(1): 107, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38448947

RESUMO

PURPOSE: To evaluate the association of body stature with ocular biometrics and refraction in preschool children. METHODS: A cross-sectional, school-based study was conducted in Shenzhen, China. Preschool children aged 3 to 6 from 10 randomly-selected kindergartens were recruited. Ocular biometric parameters, including axial length (AL), anterior chamber depth (ACD), vitreous chamber depth (VCD), corneal radius curvature (CR), axial length to corneal radius ratio (AL-to-CR ratio) and lens thickness (LT) were measured using non-contact partial-coherence laser interferometry. Cycloplegic refractions were obtained by a desktop autorefractor. Body height and weight were measured using standard procedures. The association between body stature and ocular biometrics were analyzed with univariable and multivariable regression model. RESULTS: A total of 373 preschoolers were included. AL, ACD, VCD, CR, and AL-to-CR ratio, were positively associated with height and weight (p < 0.05), whereas LT was negatively associated with height and weight (p < 0.01). No association was observed between stature and central cornea thickness and refraction. After adjusted for age and gender in a multivariable regression model, AL had positive associations with height (p < 0.01) and weight (p < 0.01). However, refraction had no significant association with stature parameters. CONCLUSION: Taller and heavier preschoolers had eyes with longer AL, deeper vitreous chamber, and flatter cornea. The significant associations between body stature and ocular biometric parameters reveal the driving influence of body development on the growth of eyeballs in preschoolers.


Assuntos
Segmento Anterior do Olho , Estatura , Pré-Escolar , Humanos , Estudos Transversais , Biometria , China/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...