Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.667
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 261, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570756

RESUMO

BACKGROUND: Non-operative management is typically indicated for extra-articular distal radius fractures. Conservative treatments such as Sugar tong splints (STs) and Muenster splints (MUs) are commonly used. However, there is limited research and outcome data comparing the two splint types. Therefore, this study aimed to investigate and compare the radiographic and clinical outcomes of treatment using STs and MUs. METHODS: In this retrospective comparative study, we aimed to evaluate and compare the radiographic and clinical outcomes of STs and MUs for the treatment of distal radius fractures. The study included 64 patients who underwent closed reduction (CR) in the emergency room and were treated with either STs or MUs splints (STs group: n = 38, MUs group: n = 26). Initial X-rays, post-CR X-rays, and last outpatient follow-up X-rays were evaluated. Radial height (RH), ulnar variance (UV), radial inclination (RI), and volar tilt (VT) were measured by a blinded investigator. The Quick DASH form was applied to measure patients' satisfaction after treatments. RESULTS: There were no significant differences in baseline characteristics, initial radiographic measurements, or radiographic measurements immediately after CR between the two groups. However, the overall radiological values deteriorated to some degree in both groups compared to the post-CR images. Furthermore, using a paired test, the STs group showed significant differences in RH and RI, and the MUs group showed significant differences in RH and UV between the last follow-up and post-CR images. CONCLUSIONS: The study concluded that there was no difference in clinical outcomes between the two splint types. However, both STs and MUs groups showed reduced radiographic parameters, and the MUs group showed a significant reduction of RH and UV in the treatment of distal radius fractures. LEVEL OF EVIDENCE: Level IV; Retrospective Comparison; Treatment Study.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Contenções , Açúcares , Fraturas do Rádio/terapia , Fraturas do Rádio/cirurgia , Amplitude de Movimento Articular , Placas Ósseas , Fixação Interna de Fraturas/métodos
3.
Int J Prosthodont ; 37(7): 31-40, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38489218

RESUMO

PURPOSE: To investigate the insertion/pull-out performance of splints produced by hand casting, thermoforming, milling, and 3D printing. MATERIALS AND METHODS: A total of 120 identical mandibular splints (n = 8 specimens per group) were manufactured with hand casting, thermoforming, milling, and 3D printing. The splints were stored in water at 37°C for 10 days and then placed onto cobalt-chromium arches and fixed on one side. Forces were applied to the other side (centric, perpendicular 50 N, 1 Hz) at two different positions (teeth 46 and 44/45) to pull out, and the test was then reset. The number of pull-out cycles until failure was recorded. The fracture behavior of the splints was investigated and characterized as fracture in the loading position, fracture at the fixation, or combined fracture. Splints were pulled off until fracture as a control (v = 1 mm/minute). Finite element analysis was used to verify the results. Statistical analyses were conducted with one-way ANOVA, post hoc Bonferroni, Pearson correlation, and Kaplan-Meier log-rank tests (α = .05). RESULTS: The mean pull-off cycles varied from 7,839 (V-Print) to 1,600,000 (Optimill) at the tooth 46 position (FDI numbering system) and from 9,064 (Splint Comfort) to 797,750 (Optimill) at the 44/45 position. Log-rank test showed significantly (P < .001) different pull-out cycles between the systems (chi-square: 61,792 to 122,377). The thickness of the splints varied between 1.6 ± 0.2 mm (Splint Comfort) and 2.3 ± 0.1 mm (V-Print). Thickness and number of cycles were correlated (Pearson: 0.164; P = .074). The pull-off forces of the control varied significantly (P ≤ .040), ranging from 13.0 N (Keysplint) to 82.2 N (Optimill) at the tooth 46 position and from 25.2 N (Keysplint) to 139.0 N (Optimill) at the 44/45 position. CONCLUSIONS: The milled and cast splints survived more pull-off cycles than the printed or thermoformed splints. The pullout performance showed differences among the tested splint systems and indicated the influence of the material properties and processing.


Assuntos
Contenções , Dente , Impressão Tridimensional , Teste de Materiais
4.
BMC Oral Health ; 24(1): 296, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38431564

RESUMO

BACKGROUND: Overerupted maxillary molars is common in adults, which can lead to insufficient intermaxillary vertical space ,great difficulty in prosthetic reconstruction ,and cause occlusal interference in movements.To reconstruct occlusal function, it is necessary to prepare enough space for prostheses. The aim of the present study was to evaluate the effect of space-adjustment occlusal splint on overerupted maxillary molars by clinical and electromyographic signals analysis. METHODS: Eighteen patients with overerupted maxillary molars were selected to wear space-adjustment occlusal splint suppressing overerupted maxillary molars for three months. Satisfaction was assessed by 5-point Likert; intermaxillary vertical space and the teeth transportation distance were measured in models; clinical periodontal status were evaluated by periodontal probing depth (PPT) and bleeding index (BI); electromyographic recordings of the masseter and anterior temporal muscles were monitored by Cranio-Mandibular K7 Evaluation System. RESULTS: All the patients were satisfied with the treatment effect (Likert scale ≧ 4). The intermaxillary space in edentulous areas after treatment showed statistically significant increasing when compared with those before treatment. PPT and BI showed no significant difference. No statistically significant differences were found in electromyographic activity of anterior temporal muscles, while a reduction of muscle activity in masseter in the contralateral side were detected in post-treatment evaluations compared with pre-treatment at mandibular rest position. CONCLUSIONS: Space-adjustment occlusal splint is an efficient treatment option on overerupted maxillary molars by intruding the maxillary molar to obtain adequate intermaxillary space for prostheses.


Assuntos
Dente Molar , Contenções , Adulto , Humanos , Dente Molar/cirurgia , Músculo Masseter/fisiologia , Músculo Temporal/fisiologia , Placas Oclusais , Eletromiografia
5.
BMC Oral Health ; 24(1): 363, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515064

RESUMO

BACKGROUND: Temporomandibular disorders (TMDs) encompass pain and dysfunction in the jaw, muscles, and adjacent structures. This study aimed to explore the quantitative (condylar position, morphology) and qualitative (bone mineral density (BMD)) therapeutic outcomes following a stabilization splint (S.S.) therapy in adult patients diagnosed with TMD (Arthralgia) with/without lateral mandibular asymmetry (MA) using cone beam computed tomography (CBCT). METHODS: In this retrospective clinical study, 60 adult TMD patients who received S.S. therapy were enrolled and allocated into the TMD group (TMDG) and TMD with MA group (TMD + MAG). The diagnosis was made according to the Diagnostic Criteria for TMD (DC/TMD) AXIS I. MA was measured from the mid-sagittal plane to the Menton point. CBCT was used to scan the temporomandibular joints pre- (T0) and post- (T1)-treatment for three-dimensional analysis. Intra- and intergroup statistical comparisons were performed using the Wilcoxon signed ranks and the Kruskal‒Wallis test. RESULTS: For quantitative comparisons, there was a statistically significant difference between T0 and T1 in the joint spaces of TMD + MAG (anterior, superior, posterior, and coronal lateral on the deviated side as well as in the superior, coronal medial joint space of the contralateral side). Morphologically, the deviated side had a narrower condylar width, reduced condylar height, and a steeper eminence angle. In contrast, the contralateral side tended to have a greater condylar length. For qualitative measurements, BMD also showed statistical significance between T0 and T1 in the majority of the condyle slopes (AS, SS, PS, and LS on the deviated side and in AS and MS on the contralateral side) of TMD + MAG. Additionally, only the AS and PS showed significance in TMDG. CONCLUSION: Multiple joint space widening (AJS and CMS) and narrowing (SJS, PJS, and CLS) could characterize the deviated side in TMD + MA. Factors like narrower condylar width, reduced condylar height, and steeper eminence angle on the deviated side can worsen TMD + MA. Proper alignment of the condyle-disc position is essential for optimal function and load distribution, potentially affecting bone mineral density (BMD). MA plays a prominent role in disturbing bone densities. S.S. therapy shows more evident outcomes in TMD + MAG (on the deviated side compared to the contralateral side) than the TMDG.


Assuntos
Côndilo Mandibular , Transtornos da Articulação Temporomandibular , Adulto , Humanos , Côndilo Mandibular/diagnóstico por imagem , Contenções , Estudos Retrospectivos , Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/diagnóstico por imagem , Transtornos da Articulação Temporomandibular/terapia , Tomografia Computadorizada de Feixe Cônico
6.
Trials ; 25(1): 193, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493121

RESUMO

BACKGROUND: Without surgical repair, flexor tendon injuries do not heal and patients' ability to bend fingers and grip objects is impaired. However, flexor tendon repair surgery also requires optimal rehabilitation. There are currently three custom-made splints used in the rehabilitation of zone I/II flexor tendon repairs, each with different assumed harm/benefit profiles: the dorsal forearm and hand-based splint (long), the Manchester short splint (short), and the relative motion flexion splint (mini). There is, however, no robust evidence as to which splint, if any, is most clinical or cost effective. The Flexor Injury Rehabilitation Splint Trial (FIRST) was designed to address this evidence gap. METHODS: FIRST is a parallel group, superiority, analyst-blind, multi-centre, individual participant-randomised controlled trial. Participants will be assigned 1:1:1 to receive either the long, short, or mini splint. We aim to recruit 429 participants undergoing rehabilitation following zone I/II flexor tendon repair surgery. Potential participants will initially be identified prior to surgery, in NHS hand clinics across the UK, and consented and randomised at their splint fitting appointment post-surgery. The primary outcome will be the mean post-randomisation score on the patient-reported wrist and hand evaluation measure (PRWHE), assessed at 6, 12, 26, and 52 weeks post randomisation. Secondary outcome measures include blinded grip strength and active range of movement (AROM) assessments, adverse events, adherence to the splinting protocol (measured via temperature sensors inserted into the splints), quality of life assessment, and further patient-reported outcomes. An economic evaluation will assess the cost-effectiveness of each splint, and a qualitative sub-study will evaluate participants' preferences for, and experiences of wearing, the splints. Furthermore, a mediation analysis will determine the relationship between patient preferences, splint adherence, and splint effectiveness. DISCUSSION: FIRST will compare the three splints with respect to clinical efficacy, complications, quality of life and cost-effectiveness. FIRST is a pragmatic trial which will recruit from 26 NHS sites to allow findings to be generalisable to current clinical practice in the UK. It will also provide significant insights into patient experiences of splint wear and how adherence to splinting may impact outcomes. TRIAL REGISTRATION: ISRCTN: 10236011.


Assuntos
Artropatias , Traumatismos dos Tendões , Humanos , Estudos Multicêntricos como Assunto , Ensaios Clínicos Pragmáticos como Assunto , Qualidade de Vida , Contenções , Traumatismos dos Tendões/diagnóstico , Traumatismos dos Tendões/cirurgia , Tendões/cirurgia , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
PLoS One ; 19(3): e0299816, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527030

RESUMO

This study evaluated the biomechanical performance of narrow-diameter implant (NDI) treatment in atrophic maxillary posterior teeth in aging patients by finite element analysis. The upper left posterior bone segment with first and second premolar teeth missing obtained from a patient's cone beam computed tomography data was simulated with cortical bone thicknesses of 0.5 and 1.0 mm. Three model groups were analyzed. The Regimen group had NDIs of 3.3 × 10 mm in length with non-splinted crowns. Experimental-1 group had NDIs of 3.0 × 10 mm in length with non-splinted crowns and Experimental-2 group had NDIs of 3.0 × 10 mm in length with splinted crowns. The applied load was 56.9 N in three directions: axial (along the implant axis), oblique at 30° (30° to the bucco-palatal plane compared to the vertical axis of the tooth), and lateral load at 90° (90° in the bucco-palatal plane compared to the vertical axis of the tooth). The results of the von Mises stress on the implant fixture, the elastic strain, and principal value of stress on the crestal marginal bone were analyzed. The axial load direction was comparable in the von Mises stress values in all groups, which indicated it was not necessary to use splinted crowns. The elastic strain values in the axial and oblique directions were within the limits of Frost's mechanostat theory. The principal value of stress in all groups were under the threshold of the compressive stress and tensile strength of cortical bone. In the oblique and lateral directions, the splinted crown showed better results for both the von Mises stress, elastic strain, and principal value of stress than the non-splinted crown. In conclusion, category 2 NDIs can be used in the upper premolar region of aging patients in the case of insufficient bone for category 3 NDI restorations.


Assuntos
Implantes Dentários , Maxila , Humanos , Análise de Elementos Finitos , Dente Pré-Molar/diagnóstico por imagem , Dente Pré-Molar/cirurgia , Maxila/diagnóstico por imagem , Maxila/cirurgia , Coroas , Contenções , Análise do Estresse Dentário , Estresse Mecânico , Fenômenos Biomecânicos
8.
Braz Oral Res ; 38: e017, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38477803

RESUMO

Occlusal stabilization splints are the most common treatment for controlling the deleterious effects of sleep bruxism. This study aimed to evaluate the effectiveness of a low-cost, mixed occlusal splint (MOS) compared to that of a rigid splint. A randomized clinical trial was performed on 43 adults of both sexes with possible sleep bruxism and satisfactory dental conditions. They were divided into rigid occlusal splint (ROS) (n = 23) and MOS (n = 20) groups. Masticatory muscle and temporomandibular joint (TMJ) pain intensity (visual analog scale), quality of life (WHOQOL-BREF), indentations in the oral mucosa, anxiety, and depression (HADS), number of days of splint use, and splint wear were evaluated. All variables were evaluated at baseline (T0), 6 months (T6), and 12 months (T12) after splint installation (T0), and splint wear was evaluated at T6 and T12. Student's t-test, Mann-Whitney U test, non-parametric Friedman's analysis of variance for paired samples and pairwise multiple comparisons, Pearson's chi-square test, two-proportion z-test, non-parametric McNemar's and Cochran's Q, and Wilcoxon tests were used (p < 0.05). In both groups, there was a decrease in TMJ pain and pain intensity over time and improvements in the quality of life scores. At T6, there was a higher rate of splint wear in the MOS group than in the ROS group (p = 0.023). The MOS showed a higher rate of wear than the rigid splint but had similar results for the other variables. Therefore, the use of a mixed splint appears to be effective in controlling the signs and symptoms of sleep bruxism.


Assuntos
Placas Oclusais , Bruxismo do Sono , Adulto , Feminino , Masculino , Humanos , Contenções , Qualidade de Vida , Espécies Reativas de Oxigênio
9.
BMC Musculoskelet Disord ; 25(1): 163, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383364

RESUMO

BACKGROUND: There is a controversy on the effectiveness of post-operating splinting in patients with carpal tunnel release (CTR) surgery. This study aimed to systematically evaluate various outcomes regarding the effectiveness of post-operating splinting in CTR surgery. METHODS: Multiple databases, including PubMed, EMBASE, CINAHL, Web of Science, and Cochrane, were searched for terms related to carpal tunnel syndrome. A total of eight studies involving 596 patients were included in this meta-analysis. The quality of studies was evaluated, and their risk of bias was calculated using the methodological index for non-randomized studies (MINORS) and Cochrane's collaboration tool for assessing the risk of bias in randomized controlled trials. Data including the visual analogue scale (VAS), pinch strength, grip strength, two-point discrimination, symptom severity score (SSS), and functional status scale (FSS) were extracted. RESULTS: Our analysis showed no significant differences between the splinted and non-splinted groups based on the VAS, SSS, FSS, grip strength, pinch strength, and two-point discrimination. The calculated values of the standardized mean difference (SMD) or the weighted mean difference (WMD) and a 95% confidence interval (CI) for different variables were as follows: VAS [SMD = 0.004, 95% CI (-0.214, 0.222)], pinch strength [WMD = 1.061, 95% CI (-0.559, 2.681)], grip strength [SMD = 0.178, 95% CI (-0.014, 0.369)], SSS [WMD = 0.026, 95% CI (- 0.191, 0.242)], FSS [SMD = 0.089, 95% CI (-0.092, 0.269)], and the two-point discrimination [SMD = 0.557, 95% CI (-0.140, 1.253)]. CONCLUSIONS: Our findings revealed no statistically significant differences between the splinted and non-splinted groups in terms of the VAS, SSS, FSS, grip strength, pinch strength, and two-point discrimination. These results indicate that there is no substantial evidence supporting a significant advantage of post-operative splinting after CTR.


Assuntos
Síndrome do Túnel Carpal , Humanos , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/cirurgia , Força da Mão , Força de Pinça , Contenções , Medição da Dor
10.
Eur J Orthod ; 46(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38376495

RESUMO

BACKGROUND: Juvenile idiopathic arthritis (JIA) frequently affects the temporomandibular joint (TMJ), which can alter mandibular growth and development and result in dentofacial deformities. OBJECTIVE: To assess the outcomes of orthopedic treatment with distraction splint (DS) in patients with JIA-related dentofacial deformity. METHODS: The retrospective study involved 30 patients with JIA and unilateral TMJ involvement, another study group of 20 patients with JIA and bilateral TMJ involvement, and a control group of 18 non-JIA orthodontic patients with Class II and III malocclusions. The inclusion criteria were DS treatment and cone-beam computed tomography (CBCT) scans before (T0) and 2 years after treatment (T1). Dentofacial morphology and deformity were evaluated based on a validated three-dimensional CBCT-based morphometric analysis. Intergroup differences in outcome measures were compared at T0 and T1, and intragroup changes between T0 and T1 were assessed using the Kruskal-Wallis test. RESULTS: Initial evaluations at T0 revealed significant differences between the unilateral and bilateral JIA groups and the control group for three out of eight dentofacial deformity variables: inter-side difference in total posterior mandibular height, mandibular axial angle, and posterior/anterior face height (ratio). At follow-up (T1), significant inter-group differences were only observed in total posterior mandibular height indicating that intergroup differences were less pronounced after splint treatment. Assessing inter-group changes between T0 and T1 showed that all parameters remained constant except posterior/anterior face height ratio, which significantly decreased between T0 and T1. CONCLUSIONS: The findings demonstrate the potential of DS treatment for patients with JIA and unilateral or bilateral TMJ involvement to generally support normal dentofacial growth or at least limit further deterioration of dentofacial deformities.


Assuntos
Artrite Juvenil , Deformidades Dentofaciais , Humanos , Artrite Juvenil/complicações , Artrite Juvenil/diagnóstico por imagem , Artrite Juvenil/terapia , Deformidades Dentofaciais/diagnóstico por imagem , Deformidades Dentofaciais/terapia , Estudos Retrospectivos , Contenções , Mandíbula/diagnóstico por imagem
11.
Clin Oral Investig ; 28(2): 141, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38340152

RESUMO

OBJECTIVES: Successful orthognathic surgery requires accurate transfer of the intraoperative surgical plan. This study aimed to (1) evaluate the surgical error of a novel intermediate splint in positioning the maxilla during maxilla-first orthognathic surgery and (2) determine factors influencing surgical error. MATERIALS AND METHODS: This prospective study examined 83 patients who consecutively underwent Le Fort I osteotomy for correction of skeletal class III deformity using a novel intermediate splint and a bilateral sagittal split osteotomy. Surgical error was the outcome variable, measured as the difference in postoperative translational and rotational maxillary position from the virtual plan. Measures included asymmetry, need and amount for mandibular opening during fabrication of intermediate splints, and planned and achieved skeletal movement. RESULTS: Mean errors in translation for vertical, sagittal, and transversal dimensions were 1.0 ± 0.7 mm, 1.0 ± 0.6 mm, and 0.7 ± 0.6 mm, respectively; degrees in rotation for yaw, roll, and pitch were 0.8 ± 0.6, 0.6 ± 0.4, and 1.6 ± 1.1, respectively. The transverse error was smaller than sagittal and vertical errors; error for pitch was larger than roll and yaw (both p < 0.001). Error for sagittal, transverse, and roll positioning was affected by the achieved skeletal movement (roll, p < 0.05; pitch and yaw, p < 0.001). Surgical error of pitch positioning was affected by planned and achieved skeletal movement (both p < 0.001). CONCLUSIONS: Using the novel intermediate splint when performing Le Fort I osteotomy allowed for accurate positioning of the maxilla. CLINICAL RELEVANCE: The novel intermediate splint for maxillary positioning can be reliably used in clinical routines.


Assuntos
Cirurgia Ortognática , Procedimentos Cirúrgicos Ortognáticos , Humanos , Maxila/cirurgia , Contenções , Estudos Prospectivos , Osteotomia de Le Fort/métodos , Procedimentos Cirúrgicos Ortognáticos/métodos , Imageamento Tridimensional/métodos , Cefalometria
12.
JAMA Netw Open ; 7(2): e2354359, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38306099

RESUMO

Importance: To date, there is currently no evidence-based medical support for the efficacy of topology-optimized splints in treating distal radius fractures. Objective: To assess the clinical efficacy and complication rates of topology-optimized splints in the treatment of distal radius fractures after closed manual reduction. Design, Setting, and Participants: This 12-week, multicenter, open-label, analyst-blinded randomized clinical trial (comprising a 6-week intervention followed by a 6-week observational phase) was carried out from December 3, 2021, to March 10, 2023, among 110 participants with distal radius fractures. Statistical analysis was performed on an intention-to-treat basis between June 3 and 30, 2023. Intervention: Participants were randomly assigned to 2 groups: the intervention group received topology-optimized splint immobilization and the control group received cast immobilization after closed manual reduction for 6weeks. After this period, immobilization was removed, and wrist rehabilitation activities commenced. Main Outcomes and Measures: The primary outcome was the Gartland-Werley (G-W) wrist score at 6 weeks (where higher scores indicate more severe wrist dysfunction). Secondary outcomes encompassed radiographic parameters, visual analog scale scores, swelling degree grade, complication rates, and 3 dimensions of G-W wrist scores. Results: A total of 110 patients (mean [SD] age, 64.1 [12.7] years; 89 women [81%]) enrolled in the clinical trial, and complete outcome measurements were obtained for 101 patients (92%). Median G-W scores at 6 weeks were 15 (IQR, 13-18) for the splint group and 17 (IQR, 13-18) for the cast group (mean difference, -2.0 [95% CI, -3.4 to -0.6]; P = .03), indicating a statistically significant advantage for the splint group. At 12 weeks, no clinically significant differences in G-W scores between the 2 groups were observed. Complication rates, including shoulder-elbow pain and dysfunction and skin irritation, were less common in the splint group (shoulder-elbow pain and dysfunction: risk ratio, 0.28 [95% CI, 0.08-0.93]; P = .03; skin irritation: risk ratio, 0.30 [95% CI, 0.10-0.89]; P = .02). Conclusions and Relevance: Findings of this randomized clinical trial suggest that patients with distal radius fractures that were managed with topology-optimized splints had better wrist functional outcomes and fewer complications at 6 weeks compared with those who received casting, with no difference at week 12. Therefore, topology-optimized splints with improved performance have the potential to be an advisable approach in the management of distal radius fractures. Trial Registration: Chinese Clinical Trial Registry: ChiCTR2000036480.


Assuntos
Artropatias , Fraturas do Rádio , Fraturas do Punho , Humanos , Feminino , Pessoa de Meia-Idade , Contenções , Fraturas do Rádio/terapia , Resultado do Tratamento , Dor
13.
J Mech Behav Biomed Mater ; 152: 106458, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38364445

RESUMO

OBJECTIVES: To investigate the influence of material and printing orientation on wear resistance and flexural properties of one low force SLA- and two DLP-printed splint materials and to compare these 3D-printed splints to a subtractively manufactured splint material. METHODS: Two DLP-printed (V-Print splint, LuxaPrint Ortho Plus) and one low force SLA-printed (Dental LT Clear) material, where specimens were printed in three printing orientations (0°, 45°, 90°), were investigated. In addition, one milled splint material (Zirlux Splint Transparent) was examined. A total of 160 specimens were produced for both test series. The two-body wear test was performed in a chewing simulator (80'000 cycles at 50 N with 5-55 °C thermocycling). Steatite balls were used as antagonists. The wear pattern was analyzed with a 3D digital microscope in terms of maximum vertical intrusion depth (mm) and total volume loss (mm³). The flexural properties were investigated by three-point bending in accordance with ISO 20795-1: 2013 (denture base polymers). The flexural strength (MPa) and the flexural modulus (MPa) were measured. Two-way ANOVA was performed to investigate the effects of the two independent variables material and printing orientation for the three 3D-printed materials. The comparison of the printing orientations within one material was carried out with one-way ANOVA with post-hoc Tukey tests. RESULTS: Two-way ANOVA revealed that wear and flexural properties are highly dependent on the 3D-printed material (p < 0.001). Across groups, a significant effect was observed for wear depth (p = 0.031) and wear volume (p = 0.044) with regard to printing orientation but this was not found for flexural strength (p = 0.080) and flexural modulus (p = 0.136). One-way ANOVA showed that both DLP-printed groups showed no significant differences within the printing orientations in terms of wear and flexural properties. Dental LT Clear showed that 90° oriented specimens had higher flexural strength than 0° oriented ones (p < 0.001) and 45° oriented specimens also showed higher values than 0° ones (p = 0.038). No significant differences were observed within the printing orientations for flexural modulus and wear behaviour within this group. T-tests showed that the milled splints exhibited statistically higher wear resistance and flexural properties compared to all three 3D-printed splint materials (p < 0.001) and that highly significant differences were found between the 3D-printed splint materials for both test series. CONCLUSION: Within the limitations of this in vitro study, it can be stated that wear behaviour and flexural properties are highly dependent on the 3D-printed material itself. Currently, milled splints exhibit higher wear resistance and flexural properties compared to 3D-printed splint materials. The printing orientation has a minor influence on the properties investigated. Nevertheless, two-way ANOVA also showed a significant influence of printing orientation in the wear test across groups and one-way ANOVA detected significant effects for SLA material in terms of flexural strength, with printing in 90° showing the highest flexural strength. Therefore, anisotropy was found in SLA material, but it can be limited with the employed printing parameters. Both DLP-printed materials showed no significant difference within the printing orientation.


Assuntos
Resistência à Flexão , Gastrópodes , Animais , Contenções , Análise de Variância , Anisotropia , Impressão Tridimensional
14.
J Oral Implantol ; 50(1): 50-64, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38329841

RESUMO

The choice of a splinted or nonsplinted implant-supported prosthesis should be based on solid scientific evidence that considers the conditions and needs of each patient. This review elaborates on the factors that directly influence clinical decisions between splinted or nonsplinted dental implants. Digital and manual searches of the published literature were conducted to identify studies that examined splinted prostheses (SPs) and nonsplinted prostheses (NSPs). The search terms used, alone or in combination, were "splinting prosthesis," "nonsplinting prosthesis," "prosthetic design," "stress distribution in dental implant," "implant loading," "implant occlusion," and "crestal bone resorption." Ninety-four studies were selected to compare and address the details emphasized in this study. Thirty-four reported articles were not directly related to restoration design but were reviewed to better understand the influence of mechanical risk factors, finite element analysis limits, and criteria for implant survival and treatment success. There are advantages and disadvantages of splinting implants together. NSPs are the ideal choice because they resemble natural teeth. Splinting a restored implant will cause the implant to appear as part of one unit and is indicated in more compromised situations, unfavorable conditions, or when pontic spaces and cantilevers are needed in implant prostheses.


Assuntos
Implantes Dentários , Humanos , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Resultado do Tratamento , Contenções
15.
Bone Joint J ; 106-B(3 Supple A): 130-136, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423088

RESUMO

Aims: Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients. Methods: A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem. Results: The design of the stem was found to have no significant influence on the rate of revision for either sex in the Young group. Uncemented collared stems had a significantly lower rate of revision compared with the other types of stem for females in the Mid-I group. There was a significantly higher rate of revision for uncemented stems in females in the Mid-II group compared with all other types of stem, while in males the rate for uncemented stems was only significantly higher than the rate for cemented stems. Cemented stems had a significantly lower revision rate compared with uncemented and short stems for both sexes in the Old cohort, as did females with collared stems. The rate of immediate postoperative mortality was similar for all types of stem in the Old age group, as were the American Society of Anesthesiologists grades. Conclusion: In patients aged > 80 years, uncemented and short stems had significantly higher revision rates compared with cemented and collared stems, especially in females. The design of the stem and type of fixation have to be analyzed in more detail than only considering cemented and uncemented fixation, in order to further improve the success of THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Feminino , Masculino , Humanos , Pessoa de Meia-Idade , Acetábulo , Período Pós-Operatório , Sistema de Registros , Contenções , Reoperação , Falha de Prótese , Desenho de Prótese
16.
Clin Oral Investig ; 28(1): 112, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38265487

RESUMO

OBJECTIVES: To assess the surgical accuracy of 3D virtually planned orthognathic surgery among patients with and without cleft. MATERIALS AND METHODS: This retrospective cohort study included cleft and non-cleft patients with class III malocclusion who underwent bimaxillary surgery. CBCT scans were acquired before and immediately after surgery. 3D virtual surgical planning (VSP) was performed using CBCT and digitalized dentition data. All orthognathic surgeries were performed by the same surgeons using interocclusal splints. The primary outcome variable was surgical accuracy, defined as the difference between the planned and surgically achieved maxillary movements, quantified in six degrees of freedom. Analysis of covariance was used to test for intergroup differences in surgical accuracy after correcting for differences in the magnitude of planned surgical maxillary movements. RESULTS: Twenty-eight cleft and 33 non-cleft patients were enrolled, with mean ages of 18.5 and 25.4 years, respectively (P=0.01). No significant gender difference was present between the groups (P=0.10). After adjustment for small differences in surgical movements, no significant differences in surgical accuracy were observed between cleft and non-cleft patients. CONCLUSION: The present study demonstrates that high surgical accuracy in maxillary movements can be achieved in both cleft and non-cleft patients using VSP and interocclusal splints. CLINICAL RELEVANCE: Orthognathic cases with cleft can be performed with 3D VSP to obtain a satisfactory surgical accuracy.


Assuntos
Exostose , Má Oclusão Classe III de Angle , Humanos , Adolescente , Adulto Jovem , Adulto , Estudos Retrospectivos , Movimento , Contenções
17.
J Indian Prosthodont Soc ; 24(1): 76-81, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38263561

RESUMO

AIM: Occlusal splint treatment is commonly used to treat a variety of temporomandibular disorders (TMDs), with efficacy ranging between 70% and 90%. Centric splints are effective in relieving muscular soreness in individuals with TMD. Electromyography (EMG) quantifies muscle activity and can be used as an accessory diagnostic tool to evaluate the efficiency of the splint on the masticatory complex. Electromyography is used for assessing patients with TMD and observing muscle electromyography. TMD patients have altered electromyographic (EMG) masticatory muscle activity because of its change in electrical activity index or because of the compensatory mechanism for the disorder. Therefore, this study serves to evaluate the efficacy of the centric stabilization splint on TMD using EMG. SETTINGS AND DESIGN: This cross-sectional study enrolled Ten TMD Patients with TMD, who underwent treatment with centric stabilization splint. MATERIALS AND METHODS: The study involved ten young adults with TMD aged 18-45 years who were recruited without regard to sex, religion, caste, or socioeconomic background. The participants were randomized to receive a flat-contact upper stabilization splint and pregelled EMG electrodes to assess the immediate impact of centric splints on TMDs. After 3 months of follow-up, muscle activity and muscle symmetrical activity were measured to assess improvement in the symptoms of TMD. STATISTICAL ANALYSIS USED: The Shapiro-Wilk test was used to assess the normality of the variables' distribution using SPSS 26.0. Symmetrical activity and treatment response were investigated using the Wilcoxon signed-rank test. RESULTS: It showed an improvement in the temporalis, masseter, and sternocleidomastoid muscles' resting EMG activity. A statistically significant improvement was seen in the EMG activity of the bilateral temporalis, right masseter, right sternocleidomastoid, and left digastric muscles while clenching. The masseter, sternocleidomastoid, and digastric muscles all displayed significantly enhanced symmetrical activity (P < 0.05). CONCLUSIONS: This research concludes that a centric stabilizing splint assists in relieving TMD symptoms. There was enhanced masticatory muscle activity both at rest and during function. Furthermore, there was an improvement in symmetrical activity of the masticatory muscles, which improved balance and enhanced the effective functioning of the masticatory complex.


Assuntos
Transtornos da Articulação Temporomandibular , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Estudos Transversais , Músculos da Mastigação , Músculos do Pescoço , Contenções
18.
Arch Phys Med Rehabil ; 105(4): 655-663, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38163530

RESUMO

OBJECTIVE: This study compares the clinical and ultrasonographic efficacy of 2 splint types, the lateral epicondylitis band (LEB) and the wrist extensor splint (WES), for treatment of lateral epicondylitis (LE). DESIGN: Randomized controlled single-blind trial. SETTING: Outpatient clinic. PARTICIPANTS: 159 participants diagnosed with unilateral LE based on clinical and ultrasonographic findings, and 2-12 weeks from symptom onset, were included (N=159). INTERVENTIONS: One group received joint-protection education-only (wait-and-see), while the other 2 groups were fit with splints: one the LEB and the other the WES. Both splint groups received joint-protection education. MAIN OUTCOME MEASURES: The primary outcome measure was the Patient-Rated Tennis Elbow Evaluation (PRTEE) questionnaire. Secondary outcome measures were the Visual Analog Scale (VAS) for pain, hand grip strength by dynamometry, algometric measurements, patient satisfaction, and selected ultrasonographic parameters (maximum tendon thickness measurements (MTTM) in the capitellar-radiocapitellar region and total ultrasonography scale score [TUSS]). All outcomes were assessed at baseline, 3-weeks, and 6-weeks post intervention initiation. RESULTS: Participants' mean age was 46.85±8.63 years. Of the participants, 40.88% (n=65) were male and 59.12% (n=94) were female. The baseline median (1Q-3Q) values of PRTEE-total scores were 58.5 (51-68) for the LEB, 63.5 (56.25-70.25) for the WES and 57 (48-68) for the education-only groups. At 6-weeks, the PRTEE-total scores had decreased by 44 points for those randomized to the LEB, 46 points to the WES and 7 points in the education-only groups(P<.001). While the LEB and WES approaches were superior to the wait-and-see approach in algometric measurements, VAS, and PRTEE scores (P<.05), no significant changes were found in MTTM and TUSS values. The LEB group was superior to the WES group in hand grip strength and patient satisfaction (P<.05). CONCLUSION: Using either splint for 6 weeks can be considered effective for the relief of pain and increased functionality in persons with subacute LE, although the LEB had a more positive effect on grip strength and patient satisfaction than the WES.


Assuntos
Artropatias , Cotovelo de Tenista , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Cotovelo de Tenista/terapia , Cotovelo de Tenista/tratamento farmacológico , Contenções , Força da Mão , Resultado do Tratamento , Estudos Prospectivos , Método Simples-Cego , Dor
19.
Clin Biomech (Bristol, Avon) ; 112: 106178, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38232471

RESUMO

BACKGROUND: Cervical collars restrict cervical spine movement to minimise the risk of spinal cord injury. Collars apply mechanical loading to the skin putting it at risk of skin damage. Indeed, cervical collar-related pressure ulcers are unacceptably prevalent, especially at the occiput, mandibles, and chin. Collar design and fit are often key considerations for prevention. METHODS: This comprehensive study evaluated four commercial prehospital and acute care cervical collars. Pressure, microclimate, transepidermal water loss and skin hydration were measured at the interface between the device and the skin. Range of motion restriction was measured to evaluate effective immobilisation. Head, neck, and shoulder morphology was evaluated using three-dimensional scans. FINDINGS: The occiput experienced significantly higher interface pressures than the chin and mandibles for most collar designs. Interface pressure at the occiput was significantly higher for the Stiffneck extrication collar compared to the other collar designs. The Stiffneck collar also provided the most movement restriction, though not significantly more than other designs. Relative humidity at the device skin interface was significantly higher for the Stiffneck and Philadelphia collars corresponding to closed cell foam padding, in contrast to the open cell foams lined with permeable fabric used in the other collars. Collar discomfort correlated with both occipital pressure and skin humidity. INTERPRETATION: The occiput is at increased risk of cervical collar-related pressure ulcers during supine immobilisation, especially for Stiffneck extrication collars. Lined open-cell foams could be used to minimise skin humidity and increase comfort.


Assuntos
Lesão por Pressão , Humanos , Lesão por Pressão/prevenção & controle , Lesão por Pressão/etiologia , Contenções , Pescoço , Vértebras Cervicais/lesões , Bioengenharia , Imobilização/efeitos adversos
20.
J Indian Prosthodont Soc ; 24(1): 15-24, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38263554

RESUMO

BACKGROUND: Disc displacement with reduction (DDwR) is among the common disc disorders of temporomandibular joint (TMJ), which can be managed conservatively by splint therapy. Anterior repositioning splint (ARS) is the most commonly prescribed splint by dental practitioners, but not getting a normal disc-condyle relationship always and other side effects lead to need of comparing with other occlusal splints. This review will help in informed decision-making by clinicians in choosing an appropriate splint type for patients. AIM: The aim is to compare the effectiveness of ARS in the management of DDwR with other occlusal splints for TMJ and muscle pain, TMJ noise, any adverse effects, regaining normal disc-condyle relationship. MATERIALS AND METHODS: We followed published protocol in the International prospective register of systematic reviews. Databases were searched till May 2023 using different search strategies as per the database. Title and abstract screening, followed by full-text screening and data extraction with risk of bias, was done by two independent reviewers in Covidence. Outcomes were reported as risk ratio (RR) or mean difference (MD) for dichotomous or continuous outcomes, respectively, using RevMan 5.4 (Review Manager 5.4) software. We used a random effect model for statistical analysis. Certainty of evidence was assessed using the Grading of Recommendation, Assessment, Development, and Evaluation Guideline Development Tool (GRADEpro GDT) software. RESULTS: A total of 1145 reports were found from a database search. After screening, four studies were included for systematic reviews. Other occlusal splints reported were sagittal vertical extrusion device and mandibular ARS, full hard stabilization splint of canine or centric stabilization type. Data of only two studies could be used for meta-analysis having 30 participants received ARS and 40 received other occlusal splints. We did not find evidence of any difference between ARS and other occlusal splints for TMJ clicking in short term (RR 1.25, 95% confidence interval [CI] 0.91-1.72) but a small difference in favor of other occlusal splint in long term (RR 2.40, 95% CI 1.04-5.55). No evidence of any difference was found between both treatments for TMJ pain in short term (MD-5.68, 95% CI-17.31-5.95) and long term (MD 0.00, 95% CI-2.86-2.86) and muscle pain in short term. The certainty of evidence for comparison of two treatments for different outcomes was of low or very low level. CONCLUSION: Evidence is uncertain that other occlusal splints reduced TMJ clicking slightly in comparison to ARS. For the remaining outcomes, no evidence of any difference was found between the two splints and it may be biased due to selection bias, inadequate blinding of participants, and outcome assessor.


Assuntos
Doenças das Cartilagens , Transtornos da Articulação Temporomandibular , Humanos , Placas Oclusais , Contenções , Odontólogos , Mialgia , Disco da Articulação Temporomandibular , Papel Profissional , Revisões Sistemáticas como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...