Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 390
Filtrar
1.
Apunts, Med. esport (Internet) ; 55(206): 63-70, abr.-jun. 2020. tab, graf
Artigo em Inglês | IBECS | ID: ibc-191745

RESUMO

INTRODUCTION: The ACL injury is considered one of the most serious injuries and usually occurs in actions that include movements with changes of direction, jump and landing. It is a common injury between the young active population and the risk in women of suffering from non-contact injury is superior to that of men. Athletes who suffer from non-contact injuries of the ACL usually have common biomechanical profiles, with landings with large values in ground reaction force (GRF) and therefore, low cushioning on landing. OBJECTIVE: To determine possible correlations between GRF and muscular activation at lading after a jump. MATERIAL AND METHODS: The type of study carried out is an observational study in which, using surface electromyography (EMG), a force platform and an electrogoniometer, the aim is to assess muscle activation and its relationship with GRF (specifically the vertical component Fz). RESULTS: Correlations have been observed between the reaction force of the soil (Fz) in the moments where the reaction force of the soil is greater and the instant where the knee reaches maximum flexion after landing, with the activation of certain muscle groups and differences depending on the gender of the subject. DISCUSSION: The neuromuscular recruitment strategies in the phases of maximum GRF load and knee flexion are different depending on the sex of the individual, so it should be considered when scheduling prevention and recovery work. CONCLUSION: The evaluation of GRF and muscle activation patterns, allows to assess the dynamics of landing after a jump and to be able to detect different patterns according to sex, with the consequent importance that it can have in the injury mechanism


No disponible


Assuntos
Humanos , Masculino , Feminino , Adulto , Músculos/fisiologia , Movimento/fisiologia , Lesões do Ligamento Cruzado Anterior , Junção Neuromuscular/fisiologia , Força Muscular/fisiologia , Eletromiografia , Articulação do Joelho/fisiopatologia , Fenômenos Biomecânicos
2.
Neurología (Barc., Ed. impr.) ; 34(6): 396-407, jul.-ago. 2019. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-185457

RESUMO

Objetivo: Revisar la evidencia científica sobre la efectividad de la aplicación de estímulos auditivos en la fase de iniciación de la marcha y giro en pacientes con enfermedad de Parkinson. Métodos: Se realizó la búsqueda en las bases de datos Brain, PubMed, Medline, Cinahl, Scopus, Science Direct, Web of Science, Cochrane Database of Systematic Reviews, Biblioteca Cochrane Plus, CENTRAL, Trip Database, PEDro, DARE, OTSeeker y Google Académico. Se incluyeron estudios que analizasen la influencia de estímulos auditivos sobre el inicio y el giro de la marcha independiente en pacientes con enfermedad de Parkinson, publicados entre 2007 y 2016. Su calidad metodológica fue valorada mediante la escala Jadad. Resultados: Se seleccionaron 13 artículos, todos ellos de baja calidad (Jadad ≤ 2) que mostraron resultados positivos en relación con el uso de estímulos auditivos a alta frecuencia e intensidad sobre el inicio de la marcha y la ejecución de giros. En concreto, 1) mejoraron los parámetros espaciotemporales y cinemáticos, 2) disminuyeron la congelación, el tiempo de giro y las caídas y 3) aumentaron la velocidad de iniciación de la marcha, la activación muscular y la velocidad y cadencia de la marcha en los pacientes con EP. Conclusiones: Se requiere un mayor número de estudios y de mayor calidad metodológica para justificar y comprender en qué estadio los pacientes se beneficiarían más de esta señal sensorial, así como el tipo de guía auditiva y la frecuencia de estimulación más eficaz en la fase de iniciación de la marcha y de giro en pacientes con Parkinson


Objective: To review the available scientific evidence about the effectiveness of auditory cues during gait initiation and turning in patients with Parkinson's disease. Methods: We conducted a literature search in the following databases: Brain, PubMed, Medline, CINAHL, Scopus, Science Direct, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Library Plus, CENTRAL, Trip Database, PEDro, DARE, OTseeker, and Google Scholar. We included all studies published between 2007 and 2016 and evaluating the influence of auditory cues on independent gait initiation and turning in patients with Parkinson's disease. The methodological quality of the studies was assessed with the Jadad scale. Results: We included 13 studies, all of which had a low methodological quality (Jadad scale score ≤ 2). In these studies, high-intensity, high-frequency auditory cues had a positive impact on gait initiation and turning. More specifically, they 1) improved spatiotemporal and kinematic parameters; 2) decreased freezing, turning duration, and falls; and 3) increased gait initiation speed, muscle activation, and gait speed and cadence in patients with Parkinson's disease. Conclusions: We need studies of better methodological quality to establish the Parkinson's disease stage in which auditory cues are most beneficial, as well as to determine the most effective type and frequency of the auditory cue during gait initiation and turning in patients with Parkinson's disease


Assuntos
Humanos , Sinais (Psicologia) , Marcha/fisiologia , Movimento/fisiologia , Doença de Parkinson/complicações , Fenômenos Biomecânicos
3.
Rev. bioét. derecho ; (46): 37-84, jul. 2019. graf
Artigo em Português | IBECS | ID: ibc-184852

RESUMO

dÉ a pessoa que inaugura a existência jurídica do ser: sem ela é difícil se chegar a acordos acerca das especificidades de direitos e deveres. No entremeio dessa relação, o transhumanismo, filosofia que advoga por um ser humano melhorado de modo a transcender sua natureza biológica, encontra respaldo prático na interação da tecnologia com a biologia, resultando na ampliação paulatina dos modos de "ser" humano, onde o ciborgue emerge como potencial humano diferenciado em vulnerabilidades e potencialidades em comparação ao Homo sapiens moderno. Assim, a personalidade jurídica contemporaneamente considerada é afetada e repensar sua formulação faz-se necessário. Sustenta-se que as inéditas possibilidades de proteção e responsabilização do ciborgue implicam sua existência jurídica através de uma nova pessoa, a pessoa não-natural


Es la persona que inaugura la existencia jurídica del ser: sin ella, es difícil llegar a acuerdos sobre las especificidades de derechos y deberes. En el centro de esa relación, el transhumanismo, filosofia que defiende un ser humano mejorado de manera a transcender su natureza biológica, encuentra respaldo práctico en la interacción de la tecnología con la biología, culminando en la ampliación paulatina de los modos de "ser" humano, donde el ciborg emerge como potencial humano diferenciado en vulnerabilidades y potencialidades en comparación al Homo sapiens moderno. Así, la personalidad jurídica contemporánea considerada es afectada y repensar su formulación se hace necesario. Se sustenta que las inéditas posibilidades de protección y responsabilización del ciborg implican su existencia jurídica a través de una nueva persona, la persona no-natural


It is the person who inaugurates the legal existence of the being: without it, it is difficult to reach agreements on the specificities of rights and duties. In the midst of this relationship, transhumanism, a philosophy that advocates an improved human being to transcend his biological nature, finds practical support in the interaction of technology with biology, resulting in the gradual expansion of human "being" modes, where the cyborg emerges as a human potential differentiated in vulnerabilities and potentialities in front of modern Homo sapiens. Thus, the contemporary legal personality is affected and it is necessary to rethink its formulation. It is argued that the possibilities of protection and responsibility of the cyborg imply an unprecedented legal existence through a new person, the non-natural person


És la persona que inaugura l'existència legal de l'ésser: sense ella és difícil arribar a acords sobre les especificitats dels drets i deures. Enmig d'aquesta relació, el transhumanisme, filosofia que advoca per un ésser humà millorat per a transcendir la seva naturalesa biològica, troba suport pràctic en la interacció de la tecnologia amb la biologia, resultant en l'expansió gradual de les maneres de "ser" humà, on el cyborg emergeix com un potencial humà diferenciat en vulnerabilitats i potencialitats enfront de l'Homo sapiens modern. Així, la personalitat jurídica contemporània es veu afectada i és necessari replantejar-se la seva formulació. S'argumenta que les possibilitats de protecció i responsabilitat del ciborg impliquen una existència jurídica sense precedents a través d'una nova persona, la persona no natural


Assuntos
Humanos , Cibernética/ética , Inteligência Artificial/ética , Robótica/ética , Aptidão/ética , Adaptação Fisiológica , Ergonomia , Desenvolvimento Humano , Inteligência Artificial/legislação & jurisprudência , Robótica/legislação & jurisprudência , Direitos Humanos/legislação & jurisprudência , Fenômenos Biomecânicos
4.
Rev. andal. med. deporte ; 12(2): 108-112, jun. 2019. ilus
Artigo em Espanhol | IBECS | ID: ibc-184508

RESUMO

Objetivo: Examinar diferencias sobre los ángulos articulares de la cadera, rodilla, tobillo y retropie en corredoras con el síndrome de fricción de la banda iliotibial en el momento de la investigación, en comparación con corredoras sin historial de lesión en la rodilla ocasionada por la carrera. Método: Teniendo en cuenta los criterios de inclusión, en este estudio retrospectivo se estudiaron a un total de 30 corredoras amateurs, 15 sanas y 15 con el síndrome de fricción de la banda iliotibial. Mediante un análisis cinemático tridimensional, se registraron los ángulos 3D de las articulaciones del miembro inferior durante la carrera en suelo. Resultados: El grupo con síndrome de fricción de la banda iliotibial mostró menor flexión de la rodilla en el inicio del contacto (13.48º versus 17.17º P = 0.02) y mayor aducción de la cadera durante el despegue (-5.65 versus -2.68 P = 0.03) en comparación al grupo de corredoras sanas. No se observaron diferencias significativas en el ángulo máximo de aducción de la cadera (P = 0.95), ángulo máximo de rotación interna de la rodilla (P = 0.80) y ángulo máximo de eversión del retropié (P = 0.16) entre los grupos. Conclusiones: Las corredoras con síndrome de fricción de la banda iliotibial actual muestran un perfil cinemático asociado a su lesión, se sugiere una falta de movilidad en varios planos de movimiento


Objective: The purpose of this retrospective study was to determine how iliotibial band syndrome influences hip, knee, ankle and rear foot joint angle in female runners with iliotibial band syndrome and female runners with no history of knee injury at the moment of study. Method: In this retrospective study, the sample was composed of 30 recreational female runners (15 healthy runners and 15 with iliotibial band syndrome). A 3-D kinematic analysis was performed to measure 3D joint angles of the lower limb. Results: The iliotibial band syndrome group exhibited a reduced knee flexion angle at heel strike (13.48º vs. 17.17º p = 0.02) and greater hip adduction at toe-off (-5.65 vs. -2.68 p = 0.03) as compared to controls. In contrast, no significant differences were observed in peak hip adduction (p = 0.95), maximum knee internal rotation (p = 0.80) and maximum rearfoot eversion (p = 0.16) between the two groups. Conclusion: Female recreational runners with ITBS exhibit a specific kinematic profile suggestive of restricted movement at several planes


Objetivo: Examinar as diferenças nos ângulos articulares do quadril, joelho, tornozelo e dorso em corredores com a Síndrome de Atrito da Banda Iliotibial no momento da investigação, em comparação com corredores sem histórico de lesão no joelho causada pela corrida. Método: Considerando os critérios de inclusão, neste estudo retrospectivo foram estudados 30 corredores amadores, sendo 15 saudáveis e 15 com síndrome de Atrito da Banda Iliotibial. Por meio de uma análise cinemática tridimensional, os ângulos 3D das articulações do membro inferior foram registrados durante a corrida no solo. Resultados: O grupo com síndrome de atrito da banda iliotibial apresentou menor flexão de joelho no início do contato (13.48º versus 17.17º p = 0.02) e maior adução do quadril durante a decolagem (-5.65 versus -2.68 p = 0.03) em comparação com o grupo de corredores saudáveis. Não foram observadas diferenças significativas no ângulo máximo de adução do quadril (p = 0.95), ângulo máximo de rotação interna do joelho (p = 0.80) e ângulo máximo de eversão do retropé (p = 0.16) entre os grupos. Conclusões: Corredores com síndrome de fricção da banda iliotibial apresentam um perfil cinemático associado à sua lesão, sugerindo uma falta de mobilidade em vários planos de movimento


Assuntos
Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Síndrome da Banda Iliotibial/epidemiologia , Corrida/fisiologia , Traumatismos em Atletas/epidemiologia , Amplitude de Movimento Articular/fisiologia , Fenômenos Biomecânicos/fisiologia , Estudos Retrospectivos , Estudos de Casos e Controles , Artralgia/fisiopatologia
5.
Fisioterapia (Madr., Ed. impr.) ; 41(3): 123-130, mayo-jun. 2019. ilus, graf, tab
Artigo em Espanhol | IBECS | ID: ibc-183087

RESUMO

Introducción: La cuantificación del rango de movimiento de la rodilla es una medida clínicamente relevante en el ámbito sanitario, ya que su disminución puede alterar las actividades de la vida diaria. La obtención de una medida fiable del rango de movimiento nos permite valorar la eficacia de las intervenciones, así como la gravedad de la enfermedad. Por esto, el objetivo de este estudio fue conocer la fiabilidad intra e interevaluador de un protocolo para el rango de movimiento articular de la rodilla llevado a cabo con un sensor inercial en sujetos asintomáticos. Métodos: Se midió el rango de movimiento de 32 rodillas en sujetos asintomáticos, se realizaron 2 sesiones de medición, una por evaluador, en el mismo día. En cada sesión se hicieron un total de 8 mediciones (2 medidas para flexión en decúbito supino, 2 medidas para extensión en decúbito supino, 2 medidas para flexión en bipedestación y 2 para la extensión en bipedestación). Resultados: Para la fiabilidad interevaluador se consiguieron buenos resultados con un ICC superior a 0,79 para todos los movimientos. Los datos obtenidos para la fiabilidad intraevaluador en todos los movimientos fueron excelentes (ICC > 0,88). Conclusión: Este estudio obtuvo una excelente fiabilidad interevaluador e intraevaluador para los sujetos sanos midiendo con sensores inerciales


Introduction: The quantification of knee range of motion is a clinically relevant measurement in the healthcare setting, as its decrease can alter activities of daily living. Collecting reliable measurements of the range of motion allows us to evaluate the reliability of interventions, or the severity of the pathology. The objective of this study was to obtain the intra- and inter- rater reliability of a protocol for the knee the range of joint motion, measured with an inertial sensor in asymptomatic subjects. Methods: The range of motion of 32 asymptomatic knees was measured. Two measurement sessions were performed by two different evaluators. A total of 8 measurements were made in each session: 2 measurements for flexion in supine decubitus position, 2 measurements for extension in supine decubitus, 2 measurements for flexion in standing position and 2 measurements for extension in standing position. Results: For inter-rater reliability, good results were achieved, with an ICC > 0.79 for all movements. The obtained data for intra-rater reliability in all the movements was excellent, with an ICC > 0.88. Conclusion: This study obtained excellent inter-rater and intra-rater reliability for healthy subjects


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Reprodutibilidade dos Testes , Joelho/fisiologia , Atividade Motora/fisiologia , Movimento , Monitorização Fisiológica/métodos , Retroalimentação Sensorial , Acelerometria/métodos , Estudos Longitudinais , Decúbito Dorsal/fisiologia , Posição Ortostática , Fenômenos Biomecânicos
6.
Nutr. hosp ; 36(2): 412-419, mar.-abr. 2019. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-184337

RESUMO

Introducción: la auscultación cervical digital plantea la identificación espectrográfica del sonido, comprendiendo el fenómeno físico-acústico de procesos normales deglutorios. Por ello, se busca fundamentar los aspectos evaluativos de la auscultación cervical a partir de la estructuración de un perfil espectrográfico por secciones, definido según la consecución fisiológica en fase faríngea. Método: se utiliza el fonendoscopio electrónico modelo 3200 de la marca Littman(R), posicionado en el punto 11 del cuello, el cual permitirá dar paso a los procedimientos de análisis espectrográficos en conjunto con el software StethAssist. Los datos fueron tratados en el software Statgraphics Centurion, que suministró descripción estadística por medio de pruebas de independencia, además de un análisis comparativo realizado mediante una tabla de ANOVA y gráfico de cajas y bigotes. Resultados: se aplica la prueba-F en la tabla ANOVA. El valor p de la prueba-F es menor que 0,05, por lo que existe una relación estadística significativa entre las medias temporal de las secciones definidas, con un nivel del 95,0% de confianza. Al plantear la correlación entre los comandos biomecánicos de la fase faríngea y los sonidos que genera el transporte de alimento se precisan los tiempos hallados en el análisis espectrográfico de la onda acústica. Conclusiones: un perfil espectrográfico de la fase faríngea en sujetos normales proporciona al profesional parámetros de interpretación funcional de la deglución, aspecto relevante teniendo en cuenta las condiciones contextuales definidas en el problema. Se estima la auscultación cervical como una herramienta de acompañamiento terapéutico que puede definir comandos faríngeos alterados


Introduction: the digital cervical auscultation proposes the spectral identification of sound, including the physical-acoustic phenomenon of normal swallowing processes. For this reason, the evaluative aspects of cervical auscultation are based on the structuring of a spectrographic profile by sections, defined according to the physiological achievement in pharyngeal phase. Method: we use the electronic stethoscope, Littman(R) model 3200, positioned at point 11 of the neck, which will allow us to make way for the spectrographic analysis procedures in conjunction with the StethAssist software. The data were processed in the Statgraphics Centurion software, which provided statistical description by means of independence tests, in addition to a comparative analysis performed through an ANOVA table and box and whisker chart. Results: the F-test is applied in the ANOVA table; the p-value of the F-test is less than 0.05, so there is a statistically significant relationship between the temporal means of the defined sections, with a level of 95.0% confidence. When proposing the correlation between the biomechanical commands of the pharyngeal phase and the sounds generated by the transport of food, the times found in the spectral analysis of the acoustic wave are needed. Conclusions: a spectral profile of the pharyngeal phase in normal subjects provides the professional parameters of functional interpretation of swallowing, a relevant aspect taking into account the contextual conditions defined in the problem. Cervical auscultation is estimated as a therapeutic accompaniment tool, which can define altered pharyngeal commands


Assuntos
Humanos , Masculino , Feminino , Adulto , Deglutição/fisiologia , Auscultação , Fenômenos Biomecânicos/fisiologia , Pescoço/anatomia & histologia , Pescoço/fisiologia , Faringe/anatomia & histologia , Faringe/fisiologia , Valores de Referência
7.
Fisioterapia (Madr., Ed. impr.) ; 41(2): 89-94, mar.-abr. 2019. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-183335

RESUMO

Antecedentes: Estudios han relacionado la posible influencia entre los desequilibrios de la biomecánica del pie y el dolor lumbar crónico (CLBP). Según indican algunos autores la limitación del movimiento de la flexión dorsal (FD) de la articulación tibioperonea-astragalina del pie (TPA) puede presentarse como un factor de riesgo en el dolor lumbar crónico. Objetivo: Evaluar el dolor lumbar crónico en sujetos con pies pronadores con limitación de la flexión dorsal del tobillo en al menos un pie, frente a sujetos pronadores con movilidad normal del tobillo. Material y método: estudio descriptivo transversal con muestreo por conveniencia realizado en una muestra compuesta por 126 sujetos con dolor lumbar crónico y pies pronados. Se comparó un grupo de sujetos con CLBP que presentaron limitación de la flexión dorsal de al menos un tobillo, frente a otro grupo de pronadores con CLBP y rango de movimiento normal de tobillo. Como herramientas de valoración de la variable dependiente se utilizó la escala visual analógica (EVA) y el Índice de discapacidad por dolor lumbar de Oswestry (ODI). Resultados: Se encontró correlación positiva entre la limitación de FD de la TPA en sujetos pronadores con CLBP frente al grupo de pronadores con CLBP y FD normal (EVA 4 ± 0,22; ODI: 11,85% ± 1,21). La limitación del movimiento de FD de TPA parece mostrarse como un factor de riesgo en el CLBP (EVA 5,3 ± 0,22; ODI: 17,90% ± 1,42; valor de p ODI = 0,004; EVA 0,009). Conclusiones: Se evidencia un mayor CLBP en el grupo de pronadores con limitación de FD de al menos una TPA frente al grupo de sujetos pronadores con rango normal de movimiento


Background: The influence between the imbalances in foot biomechanics and chronic low back pain (CLBP) has been described in different studies. Some authors suggest that the reduced ankle (TPA) dorsiflexion (FD) can present as a risk factor in chronic low back pain. Objective: To evaluate low back pain in subjects with pronated feet and limited ankle dorsiflexion compared to those with pronated feet and normal mobility of ankle. Material and method: A cross-sectional study with convenience sampling was performed on 126 subjects with chronic low back pain and pronated feet. Participants were divided into two groups, both with pronated feet but one with reduced FD in at least one foot and the other with normal FD of TPA movement. A visual analogue scale (VAS) and the Oswestry Low Back Pain Index (ODI) were used as tools for assessing the dependent variable. Results: After the analysis of the data, a positive correlation was found between the limited FD of the movement of the TPA in pronated feet subjects with CLBP versus those who had normal mobility of TPA and pronated feet (VAS 4 ± 0,22; ODI: 11.85% ± 1.21). The limitation of the joint range of the ankle seemed to be a risk factor in CLBP in pronator subjects (VAS 5.3 ± 0.22; ODI: 17.90% ± 1.42) (ODI scale = 0.004, VAS 0.009). Conclusions: There is evidence of a higher rate of chronic lumbar pain in pronated patients with reduced ankle dorsiflexion as assessed with a VAS and the ODI scale


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Dor Lombar/fisiopatologia , Articulação do Tornozelo/fisiopatologia , Resistência à Flexão/fisiologia , Dor Crônica , Fenômenos Biomecânicos , Estudos Transversais , Estudos de Casos e Controles
8.
Rev. int. med. cienc. act. fis. deporte ; 19(73): 1-18, mar. 2019. ilus, graf, tab
Artigo em Espanhol | IBECS | ID: ibc-183149

RESUMO

El objetivo es determinar la existencia de indicadores visuales (preíndices) en el golpe de derecha desde el fondo de pista tras rebote en pared en padel para cada una de las posibles direcciones (derecha, centro e izquierda) mediante análisis cinemático. Han participado en el estudio cinco jugadores expertos de padel. Los valores encontrados para altura de la mano y la posición del talón izquierdo en el momento de inicio y final del movimiento se revelan como las zonas corporales que más información podrían proporcionar como pre-índices informacionales para el jugador en defensa (r=,896, p<,001 y r=,777, p<,001). Los datos confirman la existencia de tres patrones de movimiento en virtud de la dirección elegida (máxima altura de la mano y mayor ángulo del talón izquierdo respecto al plano transversal del cuerpo cuando la bola se dirige a la parte izquierda de la cancha, tomado como referencia el jugador que golpea)


Using a kinematic analysis, this study aims to find out the existence of visual signals (pre-cues) in drive strokes made from the back of the court after the ball hits a wall, considering each possible direction (right, centre and left). Five expert paddle tennis players took part in the study. The body areas that could be most useful to the defensive player as informative pre-cues (r=.896 p<.001 y r=.777 p<.001) were those related to the hand height and the position of the left heel, at the beginning and at the end of the movement. These data confirm the existence of three movement patterns according to the chosen direction (maximum hand height and most open left heel angle in relation to the transverse plane of the body when the ball goes to the left half of the court, with the striking player as reference)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Esportes com Raquete/fisiologia , Fenômenos Biomecânicos/fisiologia
9.
Rev. int. med. cienc. act. fis. deporte ; 19(73): 19-32, mar. 2019. tab
Artigo em Espanhol | IBECS | ID: ibc-183150

RESUMO

El principal objetivo ha sido detectar las diferencias biomecánicas de tres modelos de aterrizaje: a) aterrizaje discreto (AD), con misión de amortiguar un salto vertical, b) aterrizaje preparatorio al salto vertical (APS) y c) aterrizaje que precedía a una carrera (APC). Han participado 29 deportistas donde el salto constituye una habilidad básica. Se ha utilizado una plataforma de fuerza sincronizada a una cámara de vídeo que registraba el plano sagital de los saltos. Los resultados indican que los APS y APC amortiguan más los picos de fuerza de reacción vertical que los AD. El modelo cinemático utilizado para los APS fue similar al AD, aunque la mayor actividad neural y refleja propia del ciclo estiramiento-acortamiento para realizar el posterior salto vertical haría más eficiente la absorción de impactos. La estrategia utilizada para los APC muestra un incremento del riesgo de lesión como consecuencia del desplazamiento hacia delante de la tibia


The main objective of this study was to identify biomechanical differences among three landing styles: a) discrete landing (DL) from a drop jump; b) preparatory landing preceding jumping (LPJ), and c) landing preceding running (LPR). The sample was composed of 29 athletes who perform jumps routinely. Sagittal plane jump parameters were recorded using a camera synchronized with a force plate. Peak reaction forces were attenuated more efficiently in PL and LR, as compared to DL. The kinematic model used for PL was similar to that for DL. Yet, neural and reflex activity during muscle flexion-extension during DL makes impact absorption more efficient. LR is associated with an increased risk for injury as a result of the forward displacement of the tibia


Assuntos
Humanos , Masculino , Adulto Jovem , Esportes/fisiologia , Desempenho Atlético/fisiologia , Fenômenos Biomecânicos/fisiologia
10.
Rev. int. med. cienc. act. fis. deporte ; 19(73): 33-44, mar. 2019. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-183151

RESUMO

El objetivo de la presente investigación fue determinar la influencia de las variables relacionadas con la aplicación de fuerza y el desplazamiento del centro de masas en las diferencias en la altura saltada entre el salto sin contramovimiento (SJ) y el salto con contramovimiento (CMJ). Participaron veintiséis hombres, realizando tres SJ y tres CMJ con 90° de flexión de rodilla. El desplazamiento del centro de masas y la fuerza media durante la fase de propulsión fueron significativamente superiores en el CMJ en comparación con el SJ, explicando el 75% de la diferencia entre los dos saltos y teniendo un 30% más de influencia el desplazamiento del centro de masas. No hubo diferencias en la fuerza máxima. Los resultados sugieren la necesidad de examinar el desplazamiento del centro de masas para interpretar adecuadamente las diferencias entre el SJ y el CMJ cuando el criterio establecido es 90° de flexión de rodilla


The aim of this investigation was to determine the influences of force application related variables and center of mass displacement on jump height differences between squat jump (SJ) and countermovement jump (CMJ). Twenty six males performed three squat jumps and three countermovement jumps with a 90° knee flexion. The center of mass displacement during the upward movement phase and the average force were significantly greater in CMJ than in SJ. Both variables explained 75% of the differences in the flight height, having 30% more influence the center of mass displacement. There were no differences in peak force. The results of this research suggest the need to examine the center of mass displacement during SJ and CMJ when a 90°of knee flexion criteria is established


Assuntos
Humanos , Masculino , Adolescente , Adulto Jovem , Fenômenos Biomecânicos/fisiologia , Cinese/fisiologia , Resistência à Tração/fisiologia
11.
Rev. Soc. Andal. Traumatol. Ortop. (Ed. impr.) ; 36(1): 19-27, ene.-mar. 2019. ilus
Artigo em Espanhol | IBECS | ID: ibc-181164

RESUMO

El ángulo posterolateral (APL) de la rodilla presenta una anatomía compleja que permite mantener la estabilidad frente al varo, la rotación externa y la traslación posterior. Las lesiones del APL suelen pasar desapercibidas. Se relacionan con accidentes de tráfico y deportivos. La exploración física resulta fundamental en el diagnóstico. La gravedad de la lesión determina el tipo de tratamiento, conservador o quirúrgico. El tratamiento quirúrgico se asocia a una alta incidencia de complicaciones, como la artrofibrosis y la pérdida de movilidad


The posterolateral corner of the knee has a complex anatomy that allows maintaining stability against varus, external rotation and posterior translation. These injuries usually go unnoticed. They are related to traffic accidents and sports. The physical examination is fundamental in the diagnosis. The severity of the injury determines the type of treatment, conservative or surgical. Operative treatment is associated with a high incidence of complications, such as arthrofibrosis and loss of mobility


Assuntos
Humanos , Ligamentos Colaterais/lesões , Joelho/cirurgia , Traumatismos do Joelho/classificação , Traumatismos do Joelho/epidemiologia , Traumatismos do Joelho/diagnóstico por imagem , Ligamentos Colaterais/anatomia & histologia , Espectroscopia de Ressonância Magnética/métodos , Ultrassonografia/métodos , Fenômenos Biomecânicos/fisiologia
12.
Emergencias (Sant Vicenç dels Horts) ; 31(1): 36-38, feb. 2019. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-182434

RESUMO

Objetivos: Comparar la autoextracción (AE) frente a la AE con collarines en sujetos con bajo riesgo de lesión cervical. Método: Estudio de simulación mediante análisis biomecánico con sensores inerciales, determinando la desalineación de la columna cervical durante la AE con y sin collarines cervicales. Resultados: El desequilibrio fue 3,12 (DE 34,62) grados mayor con el collarín STIFNECK (SN) (IC al 95% de -15,33 a 21,57; p =0,7234) que con AE y también 5,95 (DE 31,76) grados mayor con collarín X-COLLAR (XC) (IC al 95% de -10,98 a 22,87; p = 0,4654) que con AE. Cuando comparamos la AE con los diferentes tipos de collarines, observamos que con el collarín XC se produjeron 2,83 (DE 12,10) grados de desalineación más que con el collarín SN (IC al 95% de -3,62 a 9,27; p = 0,3650). Conclusiones: La desalineación de la columna cervical mediante la AE es similar a la provocada cuando se aplican collarines cervicales


Objective: To compare self-extraction with and without a cervical collar in subjects at low risk of cervical spine injuries. Methods: Simulation study analyzing biomechanical data from inertial sensors to detect misalignment of the cervical spine during self-extraction with and without a cervical collar. Results: Misalignment was a mean (SD) 3.12 (34.62) degrees greater during self-extraction with a Stiffneck collar in place (95% CI, -15.33 to 21.57 degrees; P=.7234) than during extraction without a collar. Misalignment was also greater, by 5.95 (31.76) degrees, with an X-collar in place (95% CI, -10.98 to 22.87; P=.4654) than without a collar. The between-collar comparison of differences showed that misalignment was 2.83 (12.10) degrees greater with the X-collar (95% CI, -3.62 to 9.27 degrees; P=.3650). Conclusion: Misalignment of the cervical spinal column is similar during self-extraction with or without a cervical collar in place


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Acidentes de Trânsito , Vértebras Cervicais/lesões , Lesões do Pescoço/prevenção & controle , Traumatismos da Coluna Vertebral/prevenção & controle , Restrição Física/instrumentação , Equipamentos de Proteção , Fenômenos Biomecânicos , Voluntários Saudáveis , Lesões do Pescoço/etiologia , Avaliação de Resultados em Cuidados de Saúde , Traumatismos da Coluna Vertebral/etiologia , Risco
13.
Rev. int. cienc. podol. (Internet) ; 13(2): 47-54, 2019. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-186915

RESUMO

En los últimos cuarenta años la popularidad de salir a correr o hacer running se ha incrementado notablemente. Su popularidad y el gran número de lesiones hace que el running sea la actividad física más estudiada por el área de la biomecánica. En la práctica clínica, se utilizan principalmente software de análisis de movimiento 2D para analizar la cinemática. Younext Direct Motion Capture(R) (Podoactiva S.L., Huesca) es un software que analiza los parámetros cinemáticos durante la carrera en el plano sagital. El objetivo general de este estudio fue determinar la fiabilidad y repetibilidad de la cinemática angular de la rodilla y del tobillo de la carrera en el plano sagital en población sana utilizando Younext Direct Motion Capture(R). Estudio piloto observacional de concordancia. 8 sujetos (5 varones y 3 mujeres) fueron filmados mientras corrían en una cinta de correr, obteniendo tres grabaciones del ciclo de la carrera de cada participante en la primera sesión. Se realizó una segunda sesión de grabaciones a los 7 días del primer registro para volver a grabar siguiendo el mismo protocolo. Se calculó el coeficiente de correlación intraclase (ICC) para determinar la fiabilidad intra-sesión e inter-sesión del software a la hora de medir la cinemática de la rodilla y del tobillo. Se obtuvo una fiabilidad intra-sesión e inter-sesión casi perfectas (ICC> 0,81) tanto para tobillo como para rodilla. Este estudio demostró que el software Younext Direct Motion Capture(R) es fiable para analizar la cinemática angular de la rodilla y del tobillo de la carrera en población adulta sana


The popularity of running has increased remarkably the past forty years. Its popularity and the large number of injuries make running the most studied physical activity in the area of biomechanics. In clinical practice, joint kinematics during running are primarily quantified by two-dimensional motion-analysis software. Younext Direct Motion Capture(R) (Podoactiva S.L., Huesca) is a software that analyzes the kinematic parameters during the running in the sagittal plane. The main goal of this study was to determine the reliability and repeatability of the angular kinematics of the knee and ankle in the sagittal plane in a healthy population using Younext Direct Motion Capture (R). Observational pilot study of concordance. 8 subjects (5 men and 3 women) were filmed while running on a treadmill, obtaining three recordings of the running cycle of each participant in the first session. A second session of recordings was made 7 days after the first recording to re-record following the same protocol. The intraclass correlation coefficient (ICC) was calculated to determine the intra-session reliability and inter-session reliability of the software when measuring the kinematics of the knee and the ankle. Very good intra-session and inter-session reliability (ICC> 0.81) were obtained for both ankle and knee measurements. This study showed that Younext Direct Motion Capture(R) software is reliable for analyzing the angular kinematics of the knee and ankle during running in a healthy adult population


Assuntos
Humanos , Masculino , Feminino , Adulto , Fenômenos Biomecânicos/fisiologia , Joelho/fisiologia , Tornozelo/fisiologia , Corrida/fisiologia , Projetos Piloto , Algoritmos , Intervalos de Confiança
14.
Rev. int. cienc. podol. (Internet) ; 13(2): 77-86, 2019. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-186919

RESUMO

Background: El embarazo es un momento en la vida de la mujer cuyos cambios fisiológicos, hormonales, y morfológicos generan grandes cambios corporales. Estos cambios se producen en un periodo de tiempo muy corto y provocan una pérdida de estabilidad y de cambios cinemáticos y cinéticos en su marcha que generan caídas y molestias musculoesqueléticas en el miembro inferior y pie. Métodos: Se ha realizado una revisión de la literatura científica para identificar los posibles estudios científicos sobre la marcha y embarazo. Se han consultado los principales buscadores y bases de datos biomédicas: Medline-pubmed, Enfispo, Scielo y Science Direct(R). El periodo de búsqueda estuvo comprendido febrero-junio de 2018. Resultados: En nuestra búsqueda hallamos 912 resúmenes de artículos con las palabras clave seleccionadas. 892 artículos de los anteriormente mencionados fueron excluidos tras leerlos por no cumplir los criterios de selección del estudio. Por lo tanto, obtuvimos 20 relevantes. Conclusión: Existen estudios experimentales que evidencian cambios en la cinemática, cinética de la marcha del tronco, pelvis, miembro inferior y pie en el embarazo y postparto


Background: Pregnancy is a moment in a woman's life whose physiological, hormonal, and morphological changes generate great bodily changes. These changes occur in a very short period of time and cause a loss of stability and a series of kinematic and kinetic changes in their gait that cause falls and musculoskeletal discomfort in the lower limb and foot. Methods: A review of the scientific literature has been carried out to identify possible scientific studies on gait and pregnancy. The main biomedical search engines and databases were consulted: Medline-Pubmed, Enfispo, Scielo and Science Direct®. The search period was comprised February-June 2018. Results: In our search we found 912 summaries of articles with the selected keywords. 892 articles of the aforementioned were excluded after reading them because they did not meet the selection criteria of the study. Therefore, we obtained 20 relevant. Conclusion: There are experimental studies that show changes in the kinematics, kinetics of the trunk, pelvis, lower limb and foot in pregnancy and postpartum


Assuntos
Humanos , Feminino , Gravidez , Adulto , Marcha/fisiologia , Fenômenos Fisiológicos Musculoesqueléticos , Caminhada/fisiologia , Fenômenos Biomecânicos , Extremidade Inferior/fisiologia , Epidemiologia Experimental , Podiatria/tendências
15.
Rev. int. med. cienc. act. fis. deporte ; 18(72): 605-619, dic. 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-180234

RESUMO

Se analizó la relación entre las penalizaciones técnicas obtenidas en la ejecución de un elemento gimnástico aislado con el nivel competitivo de las gimnastas, sus características antropométricas y las variables temporales y angulares más importantes analizadas en dicha habilidad. Fueron seleccionadas 29 gimnastas (17,1 ± 3,1 años) procedentes de distintos niveles competitivos. Tres entrenadores evaluaron la ejecución mediante una adaptación del Código de Puntuación. Se observaron asociaciones significativas directas e indirectas (p < 0,05): bajo índice de adiposidad (rho = 0,643), tiempo total de batida (rho = 0,619), tiempo total de vuelo (rho = - 0,596), máxima amplitud articular de caderas (rho = - 0,902) y máxima extensión de los tobillos (rho = - 0,738). La valoración de las penalizaciones así como el uso del nivel competitivo y del Salto Zancada como test específico han resultado ser herramientas útiles para la valoración del rendimiento


The aim of this study was to analyze the relationship between the following aspects: the technical penalties obtained in the execution of an isolated gymnastics element, the competitive level of the gymnasts, their anthropometric characteristics, and the most important temporal and angular variables analyzed in this skill. Twenty nine gymnasts (aged 17.1 ± 3.1 years) from different competition levels were selected. Three coaches evaluated the execution through an adaptation of the Code of Points. Significant direct and indirect associations were observed (p < 0.05): low adiposity index (rho = 0.643), take-off total time (rho = 0.619), flight total time (rho = - 0.596), maximum range of motion of the hips (rho = - 0.902), and maximum extension of ankles (rho = - 0.738). The assessment of penalties as well as the use of competitive level and Split Leap as specific tests, have demonstrated to be useful tools for evaluating performance


Assuntos
Humanos , Feminino , Adolescente , Adulto Jovem , Desempenho Atlético/fisiologia , Ginástica/fisiologia , Fotogrametria/métodos , Desempenho Atlético/normas , Ginástica/normas , Antropometria/métodos , Fenômenos Biomecânicos , Análise Estatística , Análise de Variância
16.
Med. oral patol. oral cir. bucal (Internet) ; 23(6): e646-e655, nov. 2018. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-176386

RESUMO

Background: The purpose of this study was to evaluate nanohardness and viscoelastic behavior of dentin surfaces treated with two canal sealer cements for dentin remineralization. Material and Methods: Dentin surfaces were subjected to: I) 37% phosphoric acid (PA) or II) 0.5 M ethylenediaminetetraacetic acid (EDTA) conditioning prior to the application of two experimental hydroxyapatite-based cements, containing sodium hydroxide (calcypatite) or zinc oxide (oxipatite), respectively. Samples were stored in simulated body fluid during 24 h or 21 d. The intertubular and peritubular dentin were evaluated using a nanoindenter to assess nanohardness (Hi). The load/displacement responses were used for the nano-dynamic mechanical analysis to estimate complex modulus (E*) and tan delta (δ). The modulus mapping was obtained by imposing a quasistatic force setpoint to which a sinusoidal force was superimposed. AFM imaging and FESEM analysis were performed. Results: After 21 d of storage, dentin surfaces treated with EDTA+calcypatite, PA+calcypatite and EDTA+oxipatite showed viscoelastic discrepancies between peritubular and intertubular dentin, meaning a risk for cracking and breakdown of the surface. At both 24 h and 21 d, tan δ values at intertubular dentin treated with the four treatments performed similar. At 21 d time point, intertubular dentin treated with PA+oxipatite achieved the highest complex modulus and nanohardness, i.e., highest resistance to deformation and functional mineralization, among groups. Conclusions: Intertubular and peritubular dentin treated with PA+oxipatite showed similar values of tan δ after 21 d of storage. This produced a favorable dissipation of energy with minimal energy concentration, preserving the structural integrity at the dentin surface


No disponible


Assuntos
Humanos , Cemento Dentário/fisiologia , Calcificação Fisiológica , Dentina/metabolismo , Cimentos para Ossos/química , Cimento de Fosfato de Zinco/administração & dosagem , Fenômenos Biomecânicos , Teste de Materiais
17.
Radiología (Madr., Ed. impr.) ; 60(5): 387-393, sept.-oct. 2018. ilus
Artigo em Espanhol | IBECS | ID: ibc-175299

RESUMO

Objetivo: El avance en aplicaciones clínicas en tomografía computarizada se ha acompañado de mejoras en herramientas de posproceso avanzado. Además de las reconstrucciones multiplanares, planares curvas, de proyección de máxima intensidad y de las reconstrucciones volumétricas, muy recientemente se ha desarrollado la reconstrucción cinemática como técnica que, basada en modelos matemáticos que simulan la de propagación de los haces de luz a través de un volumen de datos, permite obtener imágenes tridimensionales de gran realismo. En este trabajo se ilustran y comparan ejemplos de reconstrucciones cinemáticas respecto a reconstrucciones volumétricas clásicas en pacientes con patología cardiovascular, de manera que se pueden establecer fácilmente las diferencias entre ambos tipos de reconstrucción. Conclusión: la reconstrucción cinemática es un nuevo modo de representar la imagen tridimensional, que facilita la explicación y la comprensión de los hallazgos


Objective: Advances in clinical applications of computed tomography have been accompanied by improvements in advanced post-processing tools. In addition to multiplanar reconstructions, curved planar reconstructions, maximum intensity projections, and volumetric reconstructions, very recently kinematic reconstruction has been developed. This new technique, based on mathematical models that simulate the propagation of light beams through a volume of data, makes it possible to obtain very realistic three dimensional images. This article illustrates examples of kinematic reconstructions and compares them with classical volumetric reconstructions in patients with cardiovascular disease in a way that makes it easy to establish the differences between the two types of reconstruction. Conclusion: Kinematic reconstruction is a new method for representing three dimensional images that facilitates the explanation and comprehension of the findings


Assuntos
Humanos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Cardiopatias/diagnóstico por imagem , Fenômenos Biomecânicos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos
18.
Angiol. (Barcelona) ; 70(3): 106-112, mayo-jun. 2018. graf, ilus
Artigo em Espanhol | IBECS | ID: ibc-177963

RESUMO

Objetivos: La marcha es la forma de desplazamiento del ser humano. La interrelación fisiológica entre el sistema muscular y vascular ha sido poco estudiada. Conocemos la importancia de la bomba soleogemelar sobre el sistema venoso durante la marcha, por lo que proponemos un método de estudio de la hemodinámica venosa durante la marcha, un estudio que trata de correlacionar los hallazgos hemodinámicos con la secuencia de contracción y relajación muscular durante la marcha. Material y métodos: Realizamos un estudio descriptivo prospectivo sobre un total de 50 adultos sanos en el Laboratorio de Análisis del Movimiento del Hospital Universitario Infantil Niño Jesús de Madrid. El sistema de captura del movimiento fue el SMART-D de BTS Bioengineering, formado por 8 cámaras optoeléctricas y un software para reconstrucción en 3 D. Se realizó EMG de superficie (EMGs) (Free EMG 300 de BTS Bioengineering) de los músculos gastrocnemio medial y lateral, y de los músculos tibial anterior y posterior. Los sujetos caminaron sobre una cinta sin fin BH (modelo Marathon) y se realizó ecodoppler venoso poplíteo (Nemio MX Toshiba) durante la marcha. Resultados: Se estudió a 29 varones (58%) y a 21 (42%) mujeres, con una media de edad de 32 años. Se realizó el análisis y correlación del estudio de la marcha con la EMGs y el ecodoppler venoso y se obtuvo una onda positiva en el ecodoppler que se correlaciona con la contracción excéntrica del músculo gastrocnemio medial, que estabiliza la rodilla; una segunda onda de presión negativa como consecuencia del cierre valvular y relajación muscular y una tercera onda de presión positiva correlacionada con la contracción concéntrica del músculo gastrocnemio medial durante la flexión plantar y de la rodilla durante la fase de despegue de la marcha. Conclusiones: Describimos un método de análisis de la bomba muscular gemelar en relación con la hemodinámica venosa y el efecto fisiológico de la bomba muscular sobre el sistema venoso profundo


Objectives: The gait is the pattern of movement of the human being. The physiological interrelation between the muscular and vascular system has not been sufficiently studied. The importance of the soleus-calf muscle pump on the venous system during walking is known; therefore a method is proposed in order to study venous haemodynamics during walking. The aim of the study is to correlate the haemodynamic findings with the muscle contraction and relaxation sequence during walking. Material and methods: A prospective descriptive study was conducted on a total of 50 healthy adults in the Movement Analysis Laboratory of the Niño Jesús Children's University Hospital in Madrid. The movement capture system was the SMART-D of BTS-Bioengineering, consisting of 8 optoelectronic cameras and software for 3 D reconstruction. A surface electromyography (EMGs) was performed, using a Free EMG 300 (BTS Bioengineering) of the medial and lateral gastrocnemius muscle and the anterior and posterior muscle. The subjects walked on a treadmill (BH Marathon) and a popliteal venous Doppler ultrasound (Nemio MX Toshiba) was performed whilst walking. Results: The study included a total of 50 participants, with a mean age of 32 years, and 29 (58%) men and 21 (42%) women. The analysis and correlation of the study was performed, with the EMGs and the venous Doppler ultrasound, with a positive wave being obtained with the Doppler ultrasound that correlated with the eccentric contraction of medial gastrocnemius muscle, stabilising the knee. There was a second wave of negative pressure as a consequence of valvular closure and muscle relaxation. A third wave of positive pressure was then recorded that correlated with the concentric contraction of the medial gastrocnemius muscle during plantar and knee flexion during the take-off phase of the gait. Conclusions: The haemodynamic evaluation of the venous system by non-invasive tests can provide an objective basis for the diagnosis, evolution, and prognosis of patients with chronic venous insufficiency


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Eletromiografia/métodos , Ecocardiografia Doppler , Velocidade do Fluxo Sanguíneo , Marcha/fisiologia , Insuficiência Venosa/diagnóstico por imagem , Fenômenos Biomecânicos , Hemodinâmica/fisiologia , Estudos Prospectivos , Voluntários Saudáveis
19.
Rehabilitación (Madr., Ed. impr.) ; 52(1): 10-20, ene.-mar. 2018. tab, ilus, graf
Artigo em Espanhol | IBECS | ID: ibc-171601

RESUMO

Introducción. La diplejía espástica se caracteriza por la presencia de espasticidad, y como consecuencia de la misma aparecen una serie de alteraciones que obligan a optar por las soluciones más eficientes para el control motor durante la marcha. El objetivo ha sido la caracterización de la marcha en pacientes con diplejía espástica mediante análisis cinemático 3D, así como la descripción del movimiento de la cabeza, para comprobar si existe cierta homogeneidad en el patrón motor entre los sujetos de estudio a lo largo de los múltiples ciclos de marcha analizados. Material y métodos. Se analizó la marcha de 9 pacientes con diplejía espástica mediante técnicas de fotogrametría-vídeo 3D y frecuencia de muestreo 100Hz. Se ha definido un modelo mecánico original para calcular la proyección de los sistemas de referencia de los segmentos corporales a los planos sagital y frontal, así como los ángulos que forman con el plano horizontal. Resultados. La representación gráfica de los ángulos calculados en el plano sagital y frontal permite identificar la presencia de determinados patrones cinemáticos «tipo» asociados a los movimientos de los segmentos corporales. Los niveles del coeficiente de variación para los eventos definidos del ciclo de la marcha tienen valores entre 1,41 y 19,76%. Conclusiones. Los procedimientos metodológicos propuestos han permitido la caracterización cinemática del patrón motor de la marcha en los sujetos analizados. Se identificó la presencia de patrones motores relativamente homogéneos asociados a los movimientos de los segmentos corporales (AU)


Introduction. Spastic diplegia is characterised by the presence of spasticity, leading to a number of alterations requiring the most efficient solutions for motor control during gait. The aim of this study was to characterise gait through 3D kinematic analysis in patients with spastic diplegia, as well to describe head movement, to determine whether there is some homogeneity in the motor pattern between study subjects throughout the multiple gait cycles analysed. Material and methods. We analysed gait in 9 patients with spastic diplegia by means of photogrammetry-3D video and 100Hz sampling frequency. An original mechanical model was defined to calculate the projection of the reference systems of the body segments into the sagittal and frontal planes, as well as the angles formed with the horizontal plane. Results. The graphic representation of the angles calculated in the sagittal and frontal planes identified the presence of certain "typical" kinematic patterns associated with the movements of the body segments. The coefficient of variation levels for the defined gait cycle events were between 1.41% and 19.76%. Conclusions. The proposed methodological procedures allowed kinematic characterisation of gait motor pattern in the analysed subjects. These procedures identified the presence of relatively homogenous motor patterns associated with the movements of the body segments (AU)


Assuntos
Humanos , Marcha/fisiologia , Paralisia Cerebral/fisiopatologia , Espasticidade Muscular/fisiopatologia , Fenômenos Biomecânicos , Velocidade de Caminhada/fisiologia , Espasticidade Muscular/reabilitação , Transtornos Motores/reabilitação
20.
Rev. int. cienc. podol. (Internet) ; 12(2): 83-92, 2018. tab
Artigo em Espanhol | IBECS | ID: ibc-172773

RESUMO

El Hallux Valgus es una de las patologías más frecuentes en la actualidad. Existen numerosas técnicas quirúrgicas para su corrección. El objetivo de este trabajo fue realizar una revisión bibliográfica entorno a dos de las técnicas más empleadas, la osteotomía de Chevron, junto a su modificación, y la osteotomía de Scarf, para determinar cuál obtiene mejores resultados. La técnica de Chevron se realiza mediante un corte en forma de V de 60º horizontal centrada en la cabeza del primer metatarsiano, a continuación, se desplaza la cabeza metatarsal lateralmente con la finalidad de estrechar el antepié, reduciendo el ángulo intermetatarsiano (AIM). La modificación de esta técnica consiste en incorporar un brazo plantar más largo, con el objetivo de incrementar la corrección de este ángulo. La osteotomía de Scarf tiene forma de «Z» horizontal en el eje del primer metatarsiano. El fragmento más distal se traslada hacia lateral, disminuyendo también el AIM. Tras la realización de esta revisión se observó una heterogeneidad de resultados. Se requiere mayor número de estudios y de mejor calidad para determinar la dominancia de una técnica sobre otra. La mayoría de los estudios revisados no obtuvieron diferencias significativas entre ambas técnicas. Solo hay una leve superioridad de la técnica de Chevron, basada en la corrección de los ángulos AIM y ángulo del hallux valgus (AHV), la sencillez de la técnica, la osteosínteis y el coste económico total. Sin embargo, la mayoría de los autores coinciden en que los buenos resultados dependen de la experiencia del cirujano


Hallux Valgus is one of the most common pathologies today. There are many surgical techniques for their correction. The objective of this work was to carry out a literature review of two of the most frequently used techniques, The Chevron osteotomy, along with its modification, and the Scarf osteotomy, to determine which one obtains better results. The Chevron technique is performed by a V-shaped cut of 60° horizontal centered on the head of the first metatarsal, then moves the metatarsal head laterally with the purpose of narrowing the forefoot, reducing the intermetatarsal angle (IMA). The modification of this technique consists of incorporating an extended plantar limb, in order to increase the correction of this angle. The Scarf osteotomy has a horizontal «Z» shape on the axis of the first metatarsal. The most distal fragment moves to the side, also decreasing the AIM. Following this review, a heterogeneity of results was observed. More and better studies are required to determine the dominance of one technique over another. Most of the studies reviewed did not obtain significant differences between the two techniques. There is a slight preference of Chevron, based on IMA correction and hallux valgus angle (HVA), the simplicity of the technique, the osteosynthesis and the cost-effectiveness. However, most authors agree that satisfactory results depend on the experience of the surgeon


Assuntos
Humanos , Osteotomia/métodos , Hallux Valgus/cirurgia , Fenômenos Biomecânicos , Resultado do Tratamento , Análise Custo-Benefício , Custos de Cuidados de Saúde/estatística & dados numéricos , Artrometria Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA