Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros










Filtros aplicados

Intervalo de ano de publicação
1.
J. bras. pneumol ; 42(6): 447-452, Nov.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-841240

RESUMO

ABSTRACT Objective: To describe diagnostic and treatment aspects of hard metal lung disease (HMLD) and to review the current literature on the topic. Methods: This was a retrospective study based on the medical records of patients treated at the Occupational Respiratory Diseases Clinic of the Instituto do Coração, in the city of São Paulo, Brazil, between 2010 and 2013. Results: Of 320 patients treated during the study period, 5 (1.56%) were diagnosed with HMLD. All of those 5 patients were male (mean age, 42.0 ± 13.6 years; mean duration of exposure to hard metals, 11.4 ± 8.0 years). Occupational histories were taken, after which the patients underwent clinical evaluation, chest HRCT, pulmonary function tests, bronchoscopy, BAL, and lung biopsy. Restrictive lung disease was found in all subjects. The most common chest HRCT finding was ground glass opacities (in 80%). In 4 patients, BALF revealed multinucleated giant cells. In 3 patients, lung biopsy revealed giant cell interstitial pneumonia. One patient was diagnosed with desquamative interstitial pneumonia associated with cellular bronchiolitis, and another was diagnosed with a hypersensitivity pneumonitis pattern. All patients were withdrawn from exposure and treated with corticosteroid. Clinical improvement occurred in 2 patients, whereas the disease progressed in 3. Conclusions: Although HMLD is a rare entity, it should always be included in the differential diagnosis of respiratory dysfunction in workers with a high occupational risk of exposure to hard metal particles. A relevant history (clinical and occupational) accompanied by chest HRCT and BAL findings suggestive of the disease might be sufficient for the diagnosis.


RESUMO Objetivo: Descrever aspectos relacionados ao diagnóstico e tratamento de pacientes com doença pulmonar por metal duro (DPMD) e realizar uma revisão da literatura. Métodos: Estudo retrospectivo dos prontuários médicos de pacientes atendidos no Serviço de Doenças Respiratórias Ocupacionais do Instituto do Coração, localizado na cidade de São Paulo, entre 2010 e 2013. Resultados: Entre 320 pacientes atendidos no período do estudo, 5 (1,56%) foram diagnosticados com DPMD. Todos os pacientes eram do sexo masculino, com média de idade de 42,0 ± 13,6 anos e média de tempo de exposição a metal duro de 11,4 ± 8,0 anos. Os pacientes foram submetidos a avaliação clinica, história ocupacional, TCAR de tórax, prova de função pulmonar, broncoscopia com LBA e biópsia pulmonar. Todos apresentaram distúrbio ventilatório restritivo. O achado de imagem à TCAR de tórax mais frequente foi de opacidades em vidro fosco (em 80%). Em 4 pacientes, o LBA revelou presença de células gigantes multinucleadas. Em 3, foi diagnosticada pneumonia intersticial por células gigantes na biópsia pulmonar. Houve o diagnóstico de pneumonia intersticial descamativa associada à bronquiolite celular em 1 paciente e de pneumonite de hipersensibilidade em 1. Todos foram afastados da exposição e tratados com corticoide. Houve melhora em 2 pacientes e progressão da doença em 3. Conclusões: Apesar de ser uma entidade rara, a DPMD deve ser sempre considerada em trabalhadores com risco ocupacional elevado de exposição a metais duros. A história clínica e ocupacional associada a achados em TCAR de tórax e LBA sugestivos da doença podem ser suficientes para o diagnóstico.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Ligas/efeitos adversos , Ligas/toxicidade , Cobalto/efeitos adversos , Cobalto/toxicidade , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Profissionais/diagnóstico , Exposição Ocupacional/efeitos adversos , Tungstênio/efeitos adversos , Tungstênio/toxicidade , Corticosteroides/uso terapêutico , Biópsia , Doenças Pulmonares Intersticiais/tratamento farmacológico , Doenças Pulmonares Intersticiais/patologia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Doenças Profissionais/tratamento farmacológico , Doenças Profissionais/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
2.
Braz. dent. j ; 27(6): 739-743, Nov.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828077

RESUMO

Abstract The aim of this study was to analyze the tensile strength of two different resin cements used in passive cementation technique for implant-supported prosthesis. Ninety-six plastic cylinders were waxed in standardized forms, cast in commercially pure titanium, nickel-chromium and nickel-chromium-titanium alloys. Specimens were cemented on titanium cylinders using self-adhesive resin cement or conventional dual-cured resin cement. Specimens were divided in 12 groups (n=8) in accordance to metal, cement and ageing process. Specimens were immersed in distilled water at 37 °C for 24 h and half of them was thermocycled for 5,000 cycles. Specimens were submitted to bond strength test in a universal test machine EMIC-DL2000 at 5 mm/min speed. Statistical analysis evidenced higher tensile strength for self-adhesive resin cement than conventional dual-cured resin cement, whatever the used metal. Self-adhesive resin cement presented higher tensile strength compared to conventional dual-cured resin cement. In conclusion, metal type and ageing process did not influence the tensile strength results.


Resumo O objetivo deste estudo foi analisar a resistência à tração de dois diferentes cimentos resinosos usados na técnica de cimentação passiva de próteses implanto-suportadas. Noventa e seis cilindros plásticos foram encerados em formas padronizadas, fundidos em titânio grau 2 comercialmente puro e ligas de níquel-cromo e níquel-cromo-titânio. Amostras foram cimentadas sobre cilindros de titânio usando um cimento auto-adesivo ou um cimento convencional de dupla polimerização. Os espécimes foram divididos em 12 grupos (n=8) de acordo com o metal, cimento e processo de envelhecimento. Espécimes foram imersos em água destilada a 37 °C por 24 h e metade deles foi termociclado por 5,000 ciclos. Espécimes foram submetidos ao ensaio de tração numa máquina universal de ensaios (velocidade de 5 mm/min). Análise estatística evidenciou maior resistência à tração do cimento auto adesivo do que o cimento convencional de dupla polimerização, independente do metal utilizado. O cimento resinoso auto adesivo apresentou maior resistência à tração do que o cimento convencional de dupla polimerização. O tipo de metal e o processo de envelhecimento não tiveram influência nos resultados.


Assuntos
Ligas , Cimentação/métodos , Implantes Dentários , Cimentos de Resina , Resistência à Tração
3.
Braz. j. oral sci ; 15(4): 293-297, Oct.-Dec. 2016. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-875857

RESUMO

Aim: To assess the influence of aesthetic surface coating on load-deflection ratios in nickel-titanium (NiTi) orthodontic wires compared with uncoated wires.Methods: NiTi wires (0.016") from four different manufacturers (Morelli, Sorocaba, SP, Brazil; TP, La Porte, IN, USA; Eurodonto, Curitiba, PR, Brazil; Ortho Organizers, San Marcos, CA, USA) were divided into eight groups, according to presence or absence of coating: group 1, Morelli coated wire; group 2, Morelli uncoated; group 3, TP coated; group 4, TP uncoated; group 5, Eurodonto coated; group 6, Eurodonto uncoated; group 7, Ortho Organizers coated; group 8, Ortho Organizers uncoated. To determine the load-deflection ratio, a three-point bending test was performed in a AGS-X 250 KN (Shimadzu) universal testing machine.Results: The results showed that aesthetic coatings did not influence load-deflection ratio in NiTi orthodontic wires at 1-mm and 2-mm activation. However, comparison across the four tested brands revealed that Eurodonto coated wires exhibited the greatest force levels at 1-mm, 2-mm, and 3-mm deflection. At 3-mm deflection, Ortho Organizers coated wires exhibited lower force levels than all other tested brands, except for TP wires.Conclusions: We conclude that the load-deflection ratio of NiTi wires was not influenced significantly by aesthetic coatings, especially at lower activations (AU)


Assuntos
Ligas , Estética Dentária , Fios Ortodônticos , Ortodontia
4.
J. appl. oral sci ; 24(5): 496-502, Sept.-Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-797980

RESUMO

ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.


Assuntos
Ligas/química , Braquetes Ortodônticos , Fios Ortodônticos , Análise de Variância , Elasticidade , Fricção , Teste de Materiais , Níquel/química , Desenho de Aparelho Ortodôntico , Cimento de Policarboxilato/química , Valores de Referência , Estatísticas não Paramétricas , Titânio/química
5.
Clinics ; 71(5): 264-270, May 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-782834

RESUMO

OBJECTIVES: This study aimed to evaluate the safety and efficacy of a new nickel-titanium shape memory alloy compression anastomosis ring, NiTi CAR 27, in constructing an anastomosis for colorectal cancer resection compared with conventional staples. METHODS: In total, 234 consecutive patients diagnosed with colorectal cancer receiving sigmoidectomy and anterior resection for end-to-end anastomosis from May 2010 to June 2012 were retrospectively analyzed. The postoperative clinical parameters, postoperative complications and 3-year overall survival in 77 patients using a NiTi CAR 27 compression ring (CAR group) and 157 patients with conventional circular staplers (STA group) were compared. RESULTS: There were no statistically significant differences between the patients in the two groups in terms of general demographics and tumor features. A clinically apparent anastomotic leak occurred in 2 patients (2.6%) in the CAR group and in 5 patients (3.2%) in the STA group (p=0.804). These eight patients received a temporary diverting ileostomy. One patient (1.3%) in the CAR group was diagnosed with anastomotic stricture through an electronic colonoscopy after 3 months postoperatively. The incidence of postoperative intestinal obstruction was comparable between the two groups (p=0.192). With a median follow-up duration of 39.6 months, the 3-year overall survival rate was 83.1% in the CAR group and 89.0% in the STA group (p=0.152). CONCLUSIONS: NiTi CAR 27 is safe and effective for colorectal end-to-end anastomosis. Its use is equivalent to that of the conventional circular staplers. This study suggests that NiTi CAR 27 may be a beneficial alternative in colorectal anastomosis in Chinese colorectal cancer patients.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Colo Sigmoide/cirurgia , Anastomose Cirúrgica/instrumentação , Neoplasias Colorretais/cirurgia , Período Pós-Operatório , Grampeadores Cirúrgicos/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Equipamento , Segurança de Equipamentos/instrumentação , Ligas , Fístula Anastomótica/etiologia
6.
São Paulo; s.n; 2016. 72 p. ilus, tab. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867914

RESUMO

O presente estudo teve como objetivo avaliar a resistência à fadiga cíclica flexural dos instrumentos de níquel- titânio, Hyflex CM (Coltène, EUA) e TF Adaptive (SybronEndo, EUA) em diferentes situações experimentais. Todas as limas que foram selecionadas possuíam conicidade 0,04 e diâmetro de ponta 35. Utilizou-se um dispositivo desenvolvido especificamente para realizar o ensaio flexural dinâmico. Os instrumentos TF Adaptive foram divididos em 3 grupos de acordo com o ângulo de curvatura do ensaio: 45º, 60º e 90º e cada grupo subdividido em 2 subgrupos de acordo com o tipo de movimento: rotação contínua e Adaptive. Cada subgrupo era composto por 15 instrumentos TF Adaptive, totalizando 90 instrumentos. Quinze instrumentos Hyflex CM formavam o grupo 4, no ensaio com ângulo de curvatura 90 graus e rotação contínua. A simulação foi realizada em canais artificiais de aço com ângulo de 45, 60, 90 graus e raio 5m m. O número de ciclos e o tempo em segundos até a fratura foram tabulados e analisados. Entretanto, a fadiga cíclica flexural foi significante maior nos três grupos em movimento Adaptive. E as limas TF Adaptive em seu próprio movimento tiveram maior número de ciclos e tempo até a fratura quando comparadas as Hyflex CM no ensaio de 90 graus. Portanto, conclui-se que o sistema Adaptive (limas TF Adaptive + movimento Adaptive) foi mais seguro à resistência á fadiga flexural, e no ensaio de 90 graus o sistema Adaptive foi mais resistente quando comparado com as limas Hyflex CM no movimento de rotação contínua.


The aim of this work to evaluate the cyclic fatigue resistance flexural the instruments of nickel-titanium, HyFlex CM (Coltène, USA) and TF Adaptive (SybronEndo, USA) in different experimental situations. All files that were selected had 0.04 taper and tip diameter 35. We used a device developed specifically to perform the dynamic flexural test. The TF Adaptive instruments were divided into 3 groups according to the angle of curvature of the test: 45, 60 and 90 and further divided in two subgroups according to the type of movement: continuous rotation and Adaptive. Each group consisted of 15 instruments TF Adaptive totaling 90 instruments. Fifteen HyFlex CM instruments formed the group 4 in the trial of bend angle 90 degrees and continuous rotation. The simulation was performed in artificial steel angled channels 45, 60, 90 degrees and radius 5m m. The number of cycles and the time in seconds until fracture were tabulated and analyzed. However, the cyclical flexural fatigue was significantly greater in the three groups Adaptive motion. And the TF Adaptive files on your own movement had a higher number of cycles and time to fracture when the HyFlex CM compared in 90-degree test. Therefore, it is concluded that the adaptive system (TF Adaptive Motion + Adaptive files) was safer resistance to flexural fatigue, and 90 degrees test Adaptive system is more resistant when compared with the HyFlex files into continuous.


Assuntos
Humanos , Masculino , Feminino , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico , Fraturas Ósseas/prevenção & controle , Instrumentos Odontológicos/efeitos adversos , Instrumentos Odontológicos/estatística & dados numéricos , Instrumentos Odontológicos , Ligas/efeitos adversos
7.
Bauru; s.n; 2016. 94 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-881415

RESUMO

A atresia maxilar é um quadro de desarranjo de desenvolvimento do arco dentário presente em diversos tipos de má oclusão, desde as alterações transversais mais simples e puras até as formas mais graves, contemplando as divergências verticais e sagitais. O diagnóstico desta atresia, muitas vezes, é simplificado na presença ou não de mordida cruzada posterior, sendo ela unilateral ou bilateral. No entanto, faz-se necessário uma avaliação mais criteriosa que compreenda não só a própria alteração de forma do arco dentário, mas também as modificações oclusais subsequentes, como relação sagital de classe II ou III de Angle ou as discrepâncias verticais. Uma das possíveis formas de tratamento ortodôntico está ligada as expansões rápidas da maxila, método de incrementos ósseos por meio de forças ortopédicas, quando o indivíduo ainda apresenta potencial de crescimento craniofacial, ou seja, crianças e adolescentes. Já na vida adulta, esta possibilidade de ganhos ortopédicos não mais está presente e a opção não cirúrgica é o tratamento ortodôntico compensatório, por meio de expansão dentoalveolar do arco maxilar. O objetivo deste trabalho foi descrever os resultados de expansão dentoalveolar, obtidos utilizando-se o arco auxiliar de expansão em TMA (tungstênio, molibdênio e alloy), a partir de medidas lineares e angulares obtidas, bem como a integridade da cortical óssea vestibular desta área. Foi realizado um estudo retrospectivo de análise de tomografias computadorizadas, contidas na documentação ortodôntica de 13 pacientes tratados em uma clínica particular, realizadas antes e após a realização desta mecânica de expansão dentoalveolar. Para esta expansão, estes pacientes foram submetidos à instalação de um sobre-arco utilizado por vestibular como um arco auxiliar, sendo justaposto e unido ao fio de nivelamento principal (0,017x0,025 Termoativado) em cinco pontos, sendo 2 pontos nas entradas do tubo dos primeiros molares, 2 pontos entre os pré-molares e 1 ponto entre os incisivos centrais, por meio de fio de amarrilho 0,010 aço. Os resultados apresentaram ganhos estatisticamente significantes para aumento da distância das cúspides ao plano vertical mediano de todos os dentes medidos, bem como aumento da inclinação vestibular destes. A cortical óssea demonstrou adaptação, tendo deslocamento na mesma direção do movimento dentário, porém em menor quantidade. O aumento transversal das distâncias inter-dentárias também apresentou aumentos significativos e condizentes com a literatura. Desta forma, o arco auxiliar de expansão demonstrou-se eficiente para expansão dentoalveolar no paciente adulto, por meio de aumento da inclinação vestibular, com deslocamento dentário maior que o movimento de crista óssea, apresentado ganhos transversais significantes.(AU)


The Maxillary constriction is a developmental disorder present in various types of malocclusion, from the most simple and pure transverse changes to the most severe forms, causing vertical and sagittal problems. This malocclusion diagnosis is often simplified in the presence or not of posterior crossbite, which can be uni or bilateral. However, a complete evaluation must include not only the dental arch form changes, but also the subsequent occlusal modifications, such as sagittal relationships of Class II or III malocclusions and vertical discrepancies. Maxillary constriction treatment can be performed by rapid maxillary expansion, using orthopedic forces when there is still craniofacial growth. In adults, the possibility of orthopedic changes is no longer present and the non-surgical option is compensatory orthodontic treatment with dentoalveolar expansion, when the disorder magnitude allows. The objective of this study was to evaluate the effects of dentoalveolar expansion, obtained with a TMA (tungsten and molybdenum alloy) auxiliary expansion archwire, by means of linear and angular measurements, and the integrity of the buccal cortical bone in the posterior area. A retrospective analysis of CT scans, of orthodontic records of 13 patients treated at a private clinic, performed immediately before and after the auxiliary expansion archwire, was used. For the expansion, the patients underwent installation of a secondary arch combined with the primary archwire (0.017x0.025-inch heatactivated Ni-Ti), ligated in five points. Two points in the first molar tube entries, 2 points between the premolars and 1 point between the central incisors, with a 0.010- inch steel ligature wire. The results showed statistically significant transverse increase and buccal inclination for all teeth. The cortical bone showed adaptability and displacement in the same direction of tooth movement, but in smaller amounts. Thus, the auxiliary expansion arch wire proved to be effective to correct dentoalveolar constriction in adult patients, by increasing the buccal dental inclination with larger displacements than the bone crest adaptation and with significant transverse gains.(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Processo Alveolar/anatomia & histologia , Má Oclusão/terapia , Aparelhos Ortodônticos , Técnica de Expansão Palatina/instrumentação , Ligas/uso terapêutico , Molibdênio/uso terapêutico , Odontometria , Desenho de Aparelho Ortodôntico , Valores de Referência , Estudos Retrospectivos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Tungstênio/uso terapêutico
8.
Braz. dent. j ; 26(6): 624-629, Nov.-Dec. 2015. graf
Artigo em Inglês | LILACS | ID: lil-769560

RESUMO

The aim of this study was to compare the percentage of non-instrumented area of root canals prepared with different enlargements using single-file reciprocating systems (Reciproc and WaveOne) and a conventional multi-file rotary (BioRaCe) system by micro-computed tomographic analysis. Thirty mesial roots of mandibular molars with moderate curvature (10° to 20°) presenting a type II Vertucci canal configuration and similar internal volume were chosen and scanned at an isotropic resolution of 14.16 µm. The sample was assigned to 3 groups (n=10) according to the system used for root canal preparation: Reciproc, WaveOne, and BioRaCe groups. Second and third scans were taken after the canals were prepared with instruments sizes 25 and 40, respectively. The recorded images of the surface area voxels of the canals, before and after preparation were examined from the furcation level to the apex to quantify the non-instrumented surface. Statistical data were compared using GLM for repeated-measures with a significance level set at 5%. Instrumentation systems did not influence the percentage of untouched root canal surfaces (p=0.690) whilst a significant reduction in the percentage of static voxels was observed after the enlargement of the root canal (p=0.010) in all groups (p=0.507). None of the systems was able to prepare the entire surface area of the mesial root canal of mandibular molars. The increased final apical size resulted in a significant positive effect on the shaping ability of the tested systems.


Resumo O objetivo deste estudo foi comparar a porcentagem de área não-instrumentada de canais radiculares preparados com diferentes ampliações utilizando sistemas reciprocantes de lima única (Reciproc e WaveOne) e um sistema rotatório convencional de múltiplas limas (BioRaCe) usando a análise da micro tomografia computadorizada. Trinta raízes mesiais de molares inferiores com curvatura moderada (10º a 20º) apresentando a configuração classe II de Vertucci e semelhança de volume do canal foram selecionadas e escaneadas em uma resolução isotrópica de 14,16 µm. A amostra foi dividida em 3 grupos (n=10) de acordo com o sistema utilizado para a preparação do canal radicular: grupo Reciproc, grupo WaveOne e grupo BioRaCe. Segundo e terceiro escaneamentos foram realizados após os canais serem preparados com instrumentos tamanhos 25 e 40, respectivamente. As imagens registradas de voxels da área de superfície dos canais, antes e após o preparo, foram examinadas desde o nível da furca até o ápice para quantificar a superfície não instrumentada. Os dados foram comparados estatisticamente através de GLM para medidas repetidas com um nível de significância de 5%. Os sistemas de instrumentação não influenciaram o percentual de superfícies não tocadas dos canais radiculares (p=0,690), enquanto que uma redução significativa no percentual de voxels estáticos foi observada após o alargamento do canal radicular (p=0,010) em todos os grupos (p=0,507). Nenhum dos sistemas foi capaz de preparar toda a área de superfície do canal mesial dos molares inferiores. O aumento do tamanho final apical resultou num efeito positivo significativo sobre a capacidade de modelar dos sistemas testados.


Assuntos
Humanos , Ligas , Preparo de Canal Radicular , Microtomografia por Raio-X/métodos
9.
Rev. bras. epidemiol ; 18(supl.2): 132-145, Out.-Dez. 2015. tab
Artigo em Inglês | LILACS | ID: lil-776705

RESUMO

Resumo: Objetivo: Analisar as recomendações relacionadas aos comportamentos saudáveis e a adoção das práticas recomendadas entre indivíduos hipertensos e diabéticos. Métodos: Foram analisadas recomendações relacionadas aos comportamentos saudáveis segundo local do último atendimento (atenção básica; outros estabelecimentos públicos; estabelecimentos do setor privado). Os efeitos de ter um diagnóstico de hipertensão ou diabetes sobre a adoção das práticas recomendadas foram analisados por modelos de regressão logística multivariada, usando sexo, idade, e grau de escolaridade como variáveis de controle, e os seguintes desfechos: uso atual de produtos de tabaco; prática regular de atividade física no lazer; consumo recomendado de hortaliças e frutas; percepção de baixo consumo de sal; consumo frequente de doces; consumo excessivo de álcool. Resultados: Aproximadamente, 88% dos hipertensos receberam recomendações de ter uma alimentação saudável, 91% de ingerir menos sal, 83% de praticar atividade física regular, e 76% de não fumar. Entre os diabéticos, todas as recomendações relacionadas à alimentação foram muito frequentes, 95% para o hábito de ter uma alimentação com frutas e hortaliças. O efeito de ter um diagnóstico de hipertensão foi significativo para o não uso de produtos de tabaco e percepção de baixo consumo de sal. O diagnóstico de diabetes influenciou principalmente o hábito de não consumir doces frequentemente. Conclusão: Evidenciou-se que os hipertensos e diabéticos dão prioridade a não usar hábitos nocivos à saúde do que adotar práticas que lhe trarão benefícios. É preciso promover não só os efeitos adversos dos hábitos nocivos, mas também os benefícios dos comportamentos saudáveis para o envelhecimento com qualidade.


Abstract: Objective: To analyze healthy life style recommendations given in health care and the adoption of healthy behaviors among hypertension and diabetes patients. Methods: We analyzed the recommendations according to the place of the last health care visit (primary health care, other public facilities, and private health care facilities). The effects of having a diagnosis of hypertension or diabetes on the adoption of healthy practices were analyzed by multivariate logistic regression models, using sex, age, and educational level as control variables, and the following outcomes: current use of tobacco products; regular physical activity during leisure time; recommended intake of fruits and vegetables; perception of low salt intake; frequent consumption of sweets; and excessive alcohol consumption. Results: Approximately 88% of hypertension patients received recommendations to have a healthy diet, 91% to eat less salt, 83% to practice regular physical activity, and 76% to not to smoke. Among diabetic patients, all recommendations related to nutrition were very frequent, reaching 95% for the habit of having fruits and vegetables regularly. The effect of having a diagnosis of hypertension was significant for non-use of tobacco products and perception of low salt intake. The diagnosis of diabetes mainly influenced the habit of not consuming sweets often. Conclusion: Results evidenced that people with diagnosis of hypertension and diabetes give priority to not use (stop) harmful health behaviors than to adopt practices that will bring benefits to their health. It is necessary to promote not only the adverse effects of harmful habits, but also the benefits of healthy behaviors to aging well.


Assuntos
Animais , Cobaias , Ligas , Materiais Biocompatíveis , Diamante , Ouro , Próteses Neurais , Cimento de Óxido de Zinco e Eugenol
10.
Braz. oral res. (Online) ; 29(1): 1-8, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777219

RESUMO

This study aims at comparing conventional and nickel-free metal bracket surface characteristics with elemental composition by scanning electron microscopy (SEM), using energy dispersive spectroscopy (EDS). The sample consisted of 40 lower incisor brackets divided into four groups: ABZ = conventional brackets, Kirium Abzil 3M® (n = 10); RL = conventional brackets, Roth Light Morelli® (n = 10); NF = nickel-free brackets, Nickel-Free Morelli® (n = 10); and RM = nickel-free brackets, Roth Max Morelli® (n = 10). Qualitative evaluation of the bracket surface was performed using SEM, whereby surface features were described and compared. The elemental composition was analyzed by EDS. According to surface analysis,groups ABZ and RL showed a homogeneous surface, with better finishing, whereas the surfaces in groups NF and RM were rougher. The chemical components with the highest percentage were Fe, Cr and C. Groups NF and MR showed no nickel in their composition. In conclusion, the bracket surface of the ABZ and RL groups was more homogeneous, with grooves and pores, whereas the surfaces in groups NF and RM showed numerous flaws, cracks, pores and grooves. The chemical composition analysis confirmed that the nickel-free brackets had no Ni in their composition, as confirmed by the manufacturer’s specifications, and were therefore safe to use in patients with a medical history of allergy to this metal.


Assuntos
Metais/química , Níquel/química , Braquetes Ortodônticos , Análise de Variância , Ligas/química , Corrosão , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Espectrometria por Raios X , Estatísticas não Paramétricas , Propriedades de Superfície
11.
Dental press j. orthod. (Impr.) ; 19(3): 114-119, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-723151

RESUMO

OBJECTIVE: To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. MATERIAL AND METHODS : Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a ligating wire 0.10-in was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. RESULTS: Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P < 0.05), which also differed from each other (P < 0.05). As for the type of wire, 0.019 x 0.025-in steel wire (5.67 ± 3.97) showed lower means (P < 0.05) than 0.16-in NiTi wire (8.26 ± 10.92) and 0.016 x 0.021-in NiTi wire (8.51 ± 7.95), which did not differ from each other (P > 0.05). No statistical differences (P > 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. CONCLUSIONS: Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied .


OBJETIVO: comparar a resistência ao atrito entre braquetes autoligáveis e braquetes convencionais, variando o tipo de fio. MÉTODOS: foram usados braquetes incisivos Abzil Kirium Capelozza e Easy Clip. Uma ligadura elastomérica ou um fio ligável de 0,010" foi usado para ligação do fio no braquete Abzil. Três tipos de ligas de fio ortodôntico foram avaliadas: fio de NiTi de 0,016"; fio de NiTi de 0,016" x 0,022"; e fio de aço de 0,019" x 0,025". Dez observações foram feitas para cada combinação "braquete-fio-inclinação". Os braquetes foram montados em um aparelho especial, posicionados a 90° em relação ao fio, e testados em duas inclinações. O teste de atrito foi realizado na máquina universal de ensaios, a 5mm/min e com 10mm de deslocamento. As médias (em MPa) foram submetidas aos testes ANOVA e de Tukey, a 5% de significância. As superfícies dos fios e dos braquetes foram observadas no MEV. RESULTADOS: o braquete com amarrilhos metálicos (16,48 ± 8,31MPa) apresentou médias mais altas que o braquete com ligaduras elastoméricas (4,29 ± 2,16MPa) e o braquete autoligável (1,66 ± 1,57) (p < 0,05), os quais também diferiram entre si (p < 0,05). Quanto ao tipo do fio, o fio de aço de 0,019" x 0,025" (5,67 ± 3,97MPa) apresentou médias mais baixas (p < 0,05) que os fios de NiTi de 0,016" (8,26 ± 10,92MPa) e de 0,016" x 0,022" (8,51 ± 7,95), os quais não diferiram entre si (p > 0,05). Nenhuma diferença estatística (p > 0,05) foi encontrada entre inclinações de zero (7,76 ± 8,46) e cinco (7,19 ± 7,93) graus. Concluão: o atrito foi influenciado pelo tipo de braquete e sistemas de ligaduras. Diferentes aspectos morfológicos foram observados para os braquetes e fios estudados. .


Assuntos
Humanos , Ligas Dentárias/química , Materiais Dentários/química , Elastômeros/química , Desenho de Aparelho Ortodôntico , Braquetes Ortodônticos , Fios Ortodônticos , Ligas/química , Análise do Estresse Dentário/instrumentação , Fricção , Teste de Materiais , Microscopia Eletrônica de Varredura , Níquel/química , Estresse Mecânico , Propriedades de Superfície , Aço Inoxidável/química , Titânio/química
13.
Acta cir. bras ; 28(1): 10-18, jan. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-662342

RESUMO

PURPOSE: To investigate the compatibility of a new model of self-expandable tracheal stent in rats. METHODS: A new device of polyurethane covered and non - covered stent was placed in the trachea of Wistar rats. Animals were distributed in two groups: the polyurethane covered and non-covered group. Macroscopic parameters included position within the tracheal lumen, adherence to the mucosa, degree of dilatation, permeability and internal diameter. Microscopic findings evaluated were: incorporation, inflammatory activity, granulation tissue and epithelial revetment injuries. The observation follow-up was six weeks. All parameters were quantified based on determined score values. Incorporation of the stents was evaluated based on the observation if the stent was fixed into the trachea or if it could be removed. Degree of dilatation was performed by external diameter measurements. Granulation tissue was evaluated by measurements of height of the tissue growing into the tracheal lumen. RESULTS: 100% of non-covered stents had total attachment to mucosa and 100% of polyurethane covered type had adherence only. Regarding dilatation, granulation tissue, inflammatory activity and internal diameter measurements, there were no significant differences between the groups. Pathological tracheal wall injuries were present in both groups. CONCLUSION: Both models of stent demonstrated biocompatibility with the trachea. Rats are suitable for an experimental model of tracheal stent study.


Assuntos
Animais , Feminino , Masculino , Ratos , Materiais Biocompatíveis/uso terapêutico , Stents , Traqueia/cirurgia , Ligas/uso terapêutico , Teste de Materiais , Modelos Animais , Poliuretanos/uso terapêutico , Ratos Wistar , Reprodutibilidade dos Testes , Traqueia/patologia
14.
Braz. dent. sci ; 16(2): 37-43, 2013. ilus, tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-698288

RESUMO

Objective: The aim of this study was to evaluate the tensile and hardness mechanical properties, as well as the composition and microstructure of three different alloys used for implant prosthestic components casting. Methods: The alloys were divided into three groups: Tilite (Tilite), Vera (Verabond) and Malloy (DanCeramalloy). For the tensile test, the specimens (n = 10) of each group were evaluated in “alter” form and the maximum load fracture, the deformation at maximum load and Young´s modulus were determined. The data was subjected to one-way ANOVA and Turkey’s test. For the hardness test, five discs from each group were evaluated for Vickers hardness. The data was analyzed using multiple regression ANOVA followed by the Turkey’s test. The significance level was set at 5% (α = 0.05). The composition and microstructure was determined through analysis of two specimens from each group by metallographic analysis (MEV/EED). Results: With regards to maximum load tensile, the deformation and the Young´s Modulus the three alloys evaluated were statistically similar. Regarding hardness, Tilite showed significant higher values than the others alloys. Conclusion: All the examined alloys can be used in implant prosthetic components and the presence of the element Ti did not influence the mechanical behavior of the alloy


Objetivo: O objetivo deste estudo foi avaliar as propriedades mecânicas de tensão e dureza, assim com a composição e microestrutura de três diferentes ligas utilizadas em componentes protéticos de implantes. Métodos: As ligas foram divididas em três grupos: Tilite (Tilite), Vera (Verabond) e Malloy (DanCeramalloy). Para o teste de tensão, os espécimes (n = 10) de cada grupo foram avaliados em forma modificada e a força máxima de fratura, a deformação em carga máxima e o módulo de Young foram determinados. Os dados foram submetidos ao teste ANOVA a um fator e teste de Tukey. Cinco discos de cada grupo foram avaliados para o teste de dureza Vickers. Os dados foram analisados utilizando o teste ANOVA de regressão múltipla, seguido do teste de Tukey. O nível de significância adotado foi de 5% (α = 0,05). A composição e microestrutura foram determinados em dois espécimes de cada grupo por meio de análise metalográfica (MEV/EED). Resultados: Não houve diferenças estatísticas entre as três ligas estudadas em relação à força de tensão máxima, à deformação e ao modulo Young. Em relação à dureza, Tilite mostrou valores estatisticamente superiores em comparação às outras ligas. Conclusão: Todas as ligas examinadas podem ser utilizados em componentes protéticos de implantes e a presença do elemento Titânio não influenciou o comportamento das ligas.


Assuntos
Ligas , Testes de Dureza , Próteses e Implantes , Resistência à Tração
16.
Braz. dent. j ; 23(4): 387-393, 2012. tab
Artigo em Inglês | LILACS | ID: lil-658015

RESUMO

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.


Desinfetantes químicos são normalmente associados a métodos mecânicos para remover manchas e reduzir a formação do biofilme. Este estudo avaliou o efeito de desinfetantes na liberação de íons metálicos e na rugosidade superficial do titânio comercialmente puro, ligas metálicas e resina acrílica termopolimerizável, simulando 180 ensaios de imersões. Espécimes em formato de discos foram confeccionados com titânio comercialmente puro (Tritan), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Os espécimes (n=5) foram imersos nestas soluções: hipoclorito de sódio a 0,05%, Periogard, Cepacol, Corega Tabs, Medical Interporous e Polident. Como controle, foi utilizada a água deionizada. A análise quantitativa de liberação de íons metálicos foi realizada por meio de espectrometria de massa com plasma indutivamente acoplado (ELAN DRC II). O rugosímetro (Surftest SJ-201P) foi utilizado para medir a rugosidade superficial (µm). Os dados foram registrados antes e depois das imersões e avaliados por ANOVA com dois fatores e teste de Tukey (α=0,05). A liberação de níquel provou ser mais expressiva nas ligas Vi-Star e Fit Cast-V após a imersão em Medical Interporous. Houve diferença significante na rugosidade superficial da resina (p=0,011) após a imersão. O Cepacol causou maior rugosidade superficial de forma significativa. Os produtos de imersão não influenciaram nos resultados da rugosidade do metal (p=0,388). Pode-se concluir que as ligas metálicas testadas podem ser consideradas seguras para a fabricação de próteses removíveis, mas as soluções desinfetantes como o Cepacol e a pastilha Medical Interporous para a imersão diária da prótese devem ser utilizados com cautela, pois causaram maior rugosidade superficial da resina e maior liberação de íons, respectivamente.


Assuntos
Humanos , Bases de Dentadura , Ligas Dentárias/química , Higienizadores de Dentadura/química , Resinas Acrílicas/química , Ligas/química , Alumínio/análise , Berílio/análise , Boratos/química , Cetilpiridínio/química , Clorexidina/análogos & derivados , Clorexidina/química , Ligas de Cromo/química , Cromo/análise , Ácido Cítrico/química , Desinfetantes de Equipamento Odontológico/química , Materiais Dentários/química , Teste de Materiais , Metais/análise , Metais/química , Molibdênio/análise , Níquel/análise , Espectrofotometria Atômica , Propriedades de Superfície , Hipoclorito de Sódio/química , Sulfatos/química , Titânio/análise , Titânio/química
17.
Rev. clín. pesq. odontol. (Impr.) ; 6(2): 141-146, maio-ago. 2010. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-617377

RESUMO

OBJECTIVE: Based in the premise that Ti-6Al-4V orthodontic mini-implants can release metal ions into the body fluids, this research is aimed assess the cytotoxic effect of orthodontic mini-implant on L929 fibroblast cells. MATERIAL AND METHODS: Eighteen orthodontic mini-implants made of Ti-6Al-4V alloy were divided into 6 groups: 1 (golden colour, SIN), 2 (silver colour, SIN), 3 (Neodent™), 4 (INP™), 5 (Mondeal™), and 6 (Titanium Fix™). The mini-implants were immersed into Eagle’s minimum essential medium for 24 hours, where supernatant removal and contact with L929 fibroblasts were performed. Cytotoxicity was evaluated in four different periods of time: 24, 48, 72, and 168 hours. After being in contact with the mini-implants immersed, the cells were incubated for further 24 hours and then 100 ml of 0.01% neutral-red staining solution were added. After this period of time, they were fixed and a spectrophotometer was used for counting the viable cells. RESULTS: After the 24 hours period, statistical differences were found by comparing groups 1 and 2 to groups 3,4,5, and C+ (p < 0.05). After the 48 hours period, groups 1 and 2 were shown to be statistically different in relation to groups 3, 4, and C+. After the 72 hours period, statistical differences were found only in group 1 compared to groups 4, 5, 6, CC, and C+ (p < 0.05). After 7 days, no statistical differences were found between the mini-implants. CONCLUSION: Although mini-implants are made of the same alloy, there are differences in their cytotoxicity because of the different concentrations of chemical elements used for manufacturing them.


OBJETIVO: Baseando-se na premissa de que mini-implantes ortodônticos podem liberar íons metálicos nos fluidos corporais, pesquisou-se o efeito citotóxico de mini-implantes ortodônticos em fibroblastos L929. MATERIAL E MÉTODO: Dezoito mini-implantes ortodônticos confeccionados em liga Ti-6Al-4V foram divididos em seis grupos: 1 (dourados, SIN), 2 (prateados SIN), 3 (Neodent), 4 (INP), 5 (Mondeal) e 6 (Titanium Fix). Os mini-implantes foram imersos em meio mínimo essencial Eagle por 24 horas, onde efetuou-se remoção do supernadante e contato com fibroblastos L929. A citotoxicidade foi avaliada em 4 diferentes tempos: 24, 48, 72 e 168 horas. Após contato com os mini-implantes imersos, as células foram incubadas por mais 24 horas; então, 100 ml de solução corante neutra-vermelha foram adicionados. Após, foram fixadas e um espectrofotômetro foi usado para contar as células viáveis. RESULTADOS: Após o período de 23 horas, compararam-se os grupos 1 e 2 aos grupos 3, 4, 5 e C+. Após 72 horas, diferenças estatísticas foram encontradas somente no grupo 1, comparado aos grupos 4, 5, 6, CC e C+ (p < 0,05). Após 7 dias, não foram encontradas diferenças estatisticamente significantes entre os diversos mini-implantes.


Assuntos
Humanos , Animais , Ratos , Ligas/toxicidade , Materiais Dentários/toxicidade , Procedimentos de Ancoragem Ortodôntica/métodos , Titânio/química , Titânio/toxicidade , Análise de Variância , Sobrevivência Celular , Fatores de Tempo
18.
J. bras. pneumol ; 36(1): 148-151, jan.-fev. 2010. ilus
Artigo em Português | LILACS | ID: lil-539445

RESUMO

A pneumoconiose por metal duro, descrita pela primeira vez em 1964, é uma doença difusa causada por inalação de partículas de cobalto. A doença pode se manifestar de três formas diferentes: asma ocupacional, doença intersticial e alveolite alérgica. Relata-se um caso de um jovem do sexo masculino, afiador de ferramentas, com quadro de tosse seca e dispnéia progressiva há um ano, apresentando-se à admissão com pneumotórax espontâneo bilateral. O diagnóstico foi confirmado através de biópsia pulmonar a céu aberto.


Hard metal pneumoconiosis, first described in 1964, is a diffuse disease caused by the inhalation of cobalt particles. The disease can manifest as occupational asthma, interstitial disease or allergic alveolitis. We report the case of a young male, working as a tool sharpener, who presented with dry cough and progressive dyspnea for one year, as well as with spontaneous bilateral pneumothorax at admission. The diagnosis was confirmed by open lung biopsy.


Assuntos
Adulto , Humanos , Masculino , Ligas/toxicidade , Cobalto/toxicidade , Exposição Ocupacional , Pneumoconiose/patologia , Pneumotórax/etiologia , Tungstênio/toxicidade , Pneumoconiose/complicações
19.
Artigo em Português | LILACS | ID: lil-552759

RESUMO

Este artigo sucintamente descreve a evolução da liga metálica “inteligente”, com memória de forma na área de Saúde. A confecção de grampos de Judet em nitinol ocorreu no Laboratório de Transformação Mecânica da UFRGS (LdTM) e a simples verificação das qualidades superelásticas e de memória de forma foram contempladas no LdTM e no HCPA pela equipe envolvida no projeto. A título de ilustração, demonstramos com um caso clínico a aplicabilidade do grampo de Judet no cenário de instabilidade da parede torácica, a qual, além de prejudicar a mecânica respiratória, apresenta uma alta taxa de mortalidade. Os resultados preliminares evidenciaram a transformação provocada pelo calor, ocasionando o fechamento das garras dos grampos de Judet, que se manteve firme e sem alteração da consistência com o tempo, permitindo antever sua aplicabilidade num modelo experimental. Grampos de Judet em Nitinol são apresentados teoricamente como vantajosos em relação aos já existentes em aço inoxidável 316L, especialmente pela facilidade de manuseio e possível simplificação do procedimento cirúrgico. Detalhes no acabamento permitem a biocompatibilidade e o engenheiro projetista de materiais deve compatibilizar as ligas de níquel e titânio (NiTi) utilizadas nos grampos. O nitinol possui amplo emprego no cenário médico-odontológico e há normas técnicas bem definidas. A epidemiologia do trauma e a gravidade das lesões associadas à instabilidade da parede torácica evidenciam a oportunidade de estudos nessa direção. Concluímos sobre a necessidade de prosseguir para uma avaliação experimental, agregando a mensuração de parâmetros viscosos e viscoelásticos da mecânica respiratória, especialmente em seu componente de parede torácica (cw).


The aim of this article is to briefly describe the incorporation of nitinol (NiTi) – an intelligent nickel-titanium alloy presenting shape memory – for use in medical applications. Nitinol Judet staples were developed at the Mechanical Processing Laboratory (LdTM) at Universidade Federal do Rio Grande do Sul. Simple confirmation assays of superelasticity and shape memory were performed at the LdTM and Hospital de Clínicas de Porto Alegre by the project team. A clinical case was used to demonstrate the applicability of nitinol Judet staples in the treatment of flail chest, a condition characterized by respiratory mechanics associated with fairly high mortality. The initial observation revealed a transformation resulting from heat exposure causing the closure of staple prongs. With time, the consistency of the Judet staples remained unchanged, indicating the feasibility of an experimental model employing these staples. The advantages of NiTi-made Judet staples in relation to 316L stainless steel staples are outlined, with emphasis on the ease of use and possible simplification of the surgical procedure. Finishing details ensure biocompatibility, with a focus on specific adaptations in the NiTi alloy employed to manufacture the staples; nevertheless, nitinol is widely employed in medicine and dentistry, with well-defined standards. The epidemiology of trauma and the severity of lesions associated with flail chest provide an opportunity for the proposed studies. The experimental assessment of nitinol Judet staples must now address viscosity and viscoelastic parameters of respiratory mechanics, especially concerning the chest wall.


Assuntos
Humanos , Materiais Biocompatíveis , Músculos Respiratórios/lesões , Parede Torácica/lesões , Stents/efeitos adversos , Stents , Ligas , Músculos Respiratórios/patologia , Stents/normas , Técnicas de Sutura
20.
J. bras. pneumol ; 35(12): 1254-1258, dez. 2009. ilus
Artigo em Português | LILACS | ID: lil-537086

RESUMO

A doença pulmonar por metal duro é uma pneumonia intersticial por células gigantes relacionada com a exposição à poeira composta por metais duros. Neste artigo é relatado o caso de um profissional da indústria petrolífera, diagnosticado com doença pulmonar por metal duro com base na documentação clínica, radiológica, funcional pulmonar e anatomopatológica.


Hard metal lung disease, which manifests as giant cell interstitial pneumonia, is caused by exposure to hard metal dust. We report the case of an oil industry worker diagnosed with hard metal lung disease. The diagnosis was based on the clinical, radiological and anatomopathological analysis, as well as on pulmonary function testing.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Ligas/toxicidade , Cobalto/toxicidade , Doenças Pulmonares Intersticiais/patologia , Doenças Profissionais/patologia , Exposição Ocupacional/efeitos adversos , Tungstênio/toxicidade , Poeira , Células Gigantes de Corpo Estranho/patologia , Doenças Pulmonares Intersticiais/etiologia , Doenças Profissionais/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA