Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
1.
Braz. dent. sci ; 23(1): 1-6, 2020. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1049407

RESUMO

Objective: this study aimed to evaluate the effects of irrigants and dry canal on the accuracy of electronic apex locator (EAL) in locating simulated root perforations. Material and methods: twenty singlerooted, mandibular premolars were decoronated at CEJ, and the contents were removed with a barbed broach. The canals were instrumented up to a size of 15 K-file. The roots were artificially perforated at 4 mm from the anatomic apex. The actual length (AL) up to the perforation site was determined. The electronic length (EL) of perforations was obtained by Root ZX mini and iRoot in the dry canal and in the presence of 5.2% NaOCl, SmearOff, and 0.9% sodium chloride using a size 20 K-file. The differences between the EL and AL of the perforations were calculated. Statistical analyses using Friedman and Wilcoxon signed-rank tests were used to analyse the data with the level of significance set at p <0.05. Results: there were significant differences in different canal conditions with both Root ZX mini and i Root. Measurements in dry canals were significantly longer for both apex locators (p <0.05). Measurements with NaOCl were significantly shorter for both apex locators (p < 0.05). Both apex locators produced significantly accurate values for Saline and Smear OFF (p < 0.05). Conclusions: in this study, both Root ZX mini and i Root were affected by different canal conditions. The most accurate measurements were seen in the presence of saline and SmearOFF. (AU)


Objetivo: este estudo teve como objetivo avaliar os efeitos de irrigantes e canal seco na precisão do localizador apical eletrônico (EAL) em localizar perfurações radiculares simuladas. Material e métodos: vinte pré-molares inferiores unirradiculares tiveram suas coroas removidas na altura da JEC e o tecido pulpar removido com um extirpa nervos. Os canais foram instrumentados até a largura de uma lima k 15. As raízes foram perfuradas artificialmente a 4 mm do ápice anatômico. O comprimento real (AL) até o local da perfuração foi determinado. O comprimento eletrônico (EL) das perfurações foi obtido pelo Root ZX mini e iRoot no canal seco e na presença de 5,2% de NaOCl, SmearOff e 0,9% de cloreto de sódio usando uma lima K tamanho 20. As diferenças entre o EL e o AL das perfurações foram calculadas. Análises estatísticas, utilizando os testes de sinais por postos de Friedman e Wilcoxon, foram realizadas para analisar os dados com o nível de significância estabelecido em p < 0,05. Resultados: houve diferenças significativas nas diferentes condições do canal, tanto no Root ZX mini quanto no i Root. As medidas em canais secos foram significativamente maiores nos dois localizadores apicais (p < 0,05). As medidas com NaOCl foram significativamente mais curtas para os dois localizadores apicais (p<0,05). Ambos os localizadores apicais produziram valores significativamente precisos para Saline e Smear OFF (p < 0,05). Conclusões: neste estudo, tanto o Root ZX mini quanto o i Root foram afetados por diferentes condições do canal. As medidas mais precisa foram observadas na presença de soro fisiológico e SmearOFF. (AU)


Assuntos
Hipoclorito de Sódio , Dente Pré-Molar , Equipamentos Odontológicos , Produtos para Higiene Dental e Bucal
2.
Acta cir. bras ; 34(1): e20190010000008, 2019. graf
Artigo em Inglês | LILACS | ID: biblio-983687

RESUMO

Abstract Purpose: To create a question and answer tool on patents on EMHO. Methods: Was used the Thinking Design methodology divided into four phases: Discovery, Definition, Development and Delivery. Discovery Phase: Desk research was carried out in: SciELO, Pubmed, LILACS, Google and Google Scholar. Once the target audience was selected, the interviews were conducted. Definition Phase: the interviewees' difficulties were mapped, on an Excel spreadsheet. Development Phase: a brainstorming was conducted with the public interviewed. Delivery Phase: the prototype, validation and final elaboration of the tool were made. Results: Discovery Phase: 10 inventors were identified and the interviews were carried out. Definition Phase: 80% of the interviewees determined lack of information as one of the problems. The main content was defined as: the patent process, from the beginning of the idea to the deposit (70%), search for precedence (40%) and informing partners (30%). Development Phase: with the brainstorming, the tool type was defined as an interactive site. Delivery Phase: a prototype with content framework and an interactive video was presented for validation. After approval, the interactive website was developed, which was made available to the public. Conclusion: A question and answer tool on patents in EMHO was developed.


Assuntos
Humanos , Patentes como Assunto , Equipamentos Odontológicos/normas , Equipamentos e Provisões Hospitalares/normas , Inquéritos e Questionários , Estudos Retrospectivos , Pesquisa Qualitativa , Inventores
3.
Rev. estomat. salud ; 25(2): 10-16, 20180000.
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-884127

RESUMO

Objetivo: El propósito de esta investigación fue evaluar el comportamiento del sistema de ajuste locator asociado con una prótesis parcial removible (PPR) con extensión distal inferior por medio del método de análisis de elementos finitos (MEF). Materiales y Métodos: Se diseñó un modelo clase II Kennedy tridimensional utilizando un Software CAD de Solid Works 2010 (SolidWorks Corp., Concord, MA, USA), y posteriormente se procesó y analizó a través Software ANSYS versión 14. Se modelo un (1) implante Tapered Screw-Vent® (ref. TSVB10 Zimmer Dental-Carlsbad, CA, USA) de 10mm de longitud x 3.7mm de diámetro con una plataforma de 3.5mm, de hexágono interno con su respectivo tornillo de fijación; este se ubicó en el diente 37 como pilar posterior de una PPR, cuyo conector mayor fue una barra lingual colada (aleación cromo cobalto), con base combinada (metal/acrílico), con dientes a reemplazar (37, 36 y 35). Se evaluaron los esfuerzos von Mises en una carga 400N. Este análisis permitió valorar el comportamiento de las diferentes estructuras protésicas modeladas y los efectos generados en las interfases hueso-implante. Resultados: Se observaron diferencias entre los valores von Mises en todas las estructuras y ante las cargas no hubo deformaciones permanentes en ninguna de ellas. Estructuras como el hueso mostraron microdeformaciones en valores normales. Conclusiones: El comportamiento de la conexión PPR-implante, mostró una distribución de esfuerzos favorable al utilizar una PPR, sometiéndola a carga en dirección vertical.


Aim: The purpose of this research was to evaluate the behavior of the system locator settings associated with distal extension removable partial denture lower (PPR) by finite element analysis (FEA). Materials and Methods: A Class II Kennedy 3D model using a CAD software Solid Works 2010 (SolidWorks Corp., Concord, MA, USA), and subsequently processed and analyzed by ANSYS Software version Model 14. One (1) was designed implant Tapered Screw -Vent® (ref TSVB10 Zimmer Dental-Carlsbad,CA,USA.) length x 10mm diameter 3.7mm with a 3.5mm platform, internal hexagon with its respective screw fixation; this was located at the tooth 37 as a rear pillar of a PPR, whose major connector was a lingual bar casting (alloy cobalt chromium), based combined (metal/ acrylic) with teeth to replace (37, 36 and 35). Efforts were evaluated von Mises in a 400N load. This analysis allowed assessing the performance of various prosthetic structures modeled and generated effects on bone-implant interface. Results: Differences between the values von Mises in all structures and loads were observed before there was no permanent deformation in any of them. Structures such as bone showed in normal values microstrain Conclusions: The behavior of the PPRimplant connection, showed a favorable distribution efforts by using a PPR, subjecting it to load in the vertical direction


Assuntos
Humanos , Equipamentos Odontológicos , Implantes Dentários , Materiais Dentários , Modelos Dentários , Prótese Dentária , Odontologia , Prostodontia , Doença de Dent , Assistência Odontológica , Implantação Dentária , Oclusão Dentária , Prostodontia
4.
Acta odontol. latinoam ; 31(3): 138-143, 2018. tab
Artigo em Inglês | LILACS | ID: biblio-987353

RESUMO

Biofilm on dental unit waterlines can spread microbial contamination in the water. The aim of this study was to investigate microbial contamination of water from supplies and dental units before and after the implementation of a protocol for microbial quality improvement and maintenance of dental unit water. The microbial load was evaluated in water from 27 taps and dental units (reservoirs, airwater syringes and highspeed outputs without handpieces) using the Petrifilm™ system (total aerobic bacteria and fungi) and conventional culture media (enterobacteria and Legionella spp.). The bacterial load in water samples from taps and reservoirs was within the parameter established by Brazilian legislation (<500CFU/mL); but the bacterial load in samples from airwater syringes and highspeed outputs without handpieces was not. The imple mentation of the protocol for the maintenance of microbial quality in dental unit water reduced bacterial load in highspeed outputs without handpieces (p=0.004). Enterobacteria and Legionella spp. were not isolated from any of the water samples from taps and dental units (AU)


Biofilme nas linhas d'água de equipos odontológicos pode propagar contaminação microbiana na água. O objetivo deste estudo foi investigar a contaminação microbiana da água de abastecimentos e equipos odontológicos antes e após a implemen tação de um protocolo para melhoria e manutenção da qualidade microbiológica da água de equipos odontológicos. Avaliouse a carga microbiana da água de 27 torneiras e equipos (reservatórios, seringas tríplice e alta rotação sem as peças de mão) de uma clínica odontológica por meio do sistema Petrifilm™ (bactérias aeróbias totais e fungos) e meios de cultura convencionais (enterobactérias e Legionella spp.). A carga bacteriana em amostras de água das torneiras e reservatórios estava dentro do parâmetro estabelecido pela legislação brasileira (<500 UFC/mL), mas a carga bacte riana das seringas tríplices e das saídas dos alta rotação sem as peças de mão não estava. A implementação do protocolo para manutenção da qualidade da água dos equipos reduziu a carga bacteriana nas saídas dos alta rotação sem as peças de mão (p=0,004). Enterobactérias e Legionella spp. não foram isoladas de qualquer das amostras de água das torneiras e dos equipos odontológicos (AU)


Assuntos
Microbiologia da Água , Contaminação de Equipamentos , Biofilmes , Equipamentos Odontológicos , Qualidade da Água , Brasil , Contagem de Colônia Microbiana , Análise Estatística , Meios de Cultura , Protocolos
5.
Rev. Ateneo Argent. Odontol ; 56(1): 49-58, jun. 2017. ilus
Artigo em Espanhol | LILACS | ID: biblio-869407

RESUMO

La radiología odontológica ha jugado un rol fundamental en el diagnóstico odontológico. El avance en la adquisición y procesado de la imagen digital produjo el desarrollo de nuevas tecnologías que han revolucionado el manejo del intercambio de la información en odontología. Las radiografías intraorales y extraorales se han adaptado a esa revolución digital. La búsqueda automatizada, el acceso a la literatura en formato electrónico y el intercambio de texto, imágenes y sonido en tiempo real son algunas de las características que lo hacen un elemento imprescindible dentro de la práctica en salud y los actuales estándares de la atención odontológica. El reciente desarrollo de la tomografía computada de haz cónico ha reemplazado el uso de la tomografía computada médica en odontología. En este artículo se hace una introducción en los métodos actuales y en cómo han cambiado el diagnóstico radiológico en odontología.


Dental radiology has played a fundamental role in the dental diagnosis. The advance of the acquisition and processing of the digital image produced the development of new technologies that have revolutionized the management of the information exchange in dentistry. Intraoral and extraoral radiographies have adapted to this digital revolution. The automated search, access to literature in electronic format and the interchange of text, images and sound in real time, are some of the features that make an essential element within the practice in health and the standard of dental care. The recent development of cone beam computerized tomography has replaced the use of computed tomography in dentistry. This article is an introduction to the current methods employed and how they have changed the radiological diagnosis in dentistry.


Assuntos
Humanos , Diagnóstico por Imagem , Radiografia Dentária , Tomografia Computadorizada de Feixe Cônico/métodos , Consultórios Odontológicos , Doenças da Boca/diagnóstico por imagem , Equipamentos Odontológicos/normas , Radiografia Panorâmica/métodos , Especialidades Odontológicas , Tecnologia Odontológica
6.
Rev. Ateneo Argent. Odontol ; 55(1): 57-63, 2016. ilus
Artigo em Espanhol | LILACS | ID: lil-794293

RESUMO

En odontología, para la obtención de imágenes radiográficas intraorales por métodos convencionales, se utilizan paquetes radiográficos que contienen en su interior a la película radiográfica. Luego de la exposición del paquete radiográfico a los rayos X se realiza el procesado, lo cual requiere el uso de líquidos reveladores y fijadores, que son las sustancias químicas que harán posible la visualización de la imagen.Tanto el paquete radiográfico como lo líquidos de procesado presentan en su constitución elementos que, por sus características, pueden ser incluidos enel rubro de “elementos peligrosos” para la salud y para el medio ambiente. En este trabajo de divulgación se pretende realizar un análisis de las características que hacen a la peligrosidad de cada uno de los componentes del paquete radiográfico y de los líquidos —revelador y fijador— usados en el procesado, lo cual es necesario conocer para el manejo seguro y adecuado de este tipo de elementos...


Assuntos
Humanos , Exposição a Produtos Químicos , Radiografia Dentária/efeitos adversos , Radiografia Dentária/instrumentação , Radiografia Dentária/normas , Águas Residuárias/legislação & jurisprudência , Contaminação Química , Equipamentos Odontológicos/normas , Eliminação de Resíduos Perigosos , Filme para Raios X/normas
7.
Ortodontia ; 48(6): 546-554, nov.-dez.2015. ilus, tab
Artigo em Português | LILACS | ID: lil-783994

RESUMO

Diante da grande oferta de ortodontistas no mercado, a diferenciação é almejada por todos. Essa diferenciação passa por altas cargas horárias em cursos de especialização e atualização, até a estruturação e design do consultório. A modernização dos processos internos da clínica pode reduzir o tempo gasto com atividades repetitivas, além de auxiliar no marketing positivo. No entanto, a aquisição de equipamentos tecnológicos sem o adequado planejamento pode gerar custos extras sem o retorno esperado, uma vez que toda mudança requer comprometimento e motivação da equipe. Muitos serviços estão disponíveis na internet para ajudar na melhoria dos serviços prestados e automatização das atividades. Desta forma, este artigo objetivou apresentar alguns desses serviços, bem como discutir a necessidade de equipamentos para um investimento consciente no consultório...


Faced with the wide range of orthodontists, differentiation is desired by everyone and goes through high workloads of specialization and refresher courses to the structuring and office design. The modernization of internal processes of the clinic can reduce the time spent on repetitive activities, and assist in the positive marketing. However, the acquisition of technological equipment without proper planning can generate extra costs without the expected return, since every change requires commitment and motivation of the team. Many services are available online to help improve services and automation of activities. This article presents some of these services, as well as discusses the need for equipment for conscious investment in the office...


Assuntos
Humanos , Consultórios Odontológicos/tendências , Informática Odontológica , Equipamentos Odontológicos/tendências , Equipamentos Odontológicos , Tecnologia Odontológica , Computadores , Internet
8.
Full dent. sci ; 6(23): 275-278, jul. 2015. tab, ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-773996

RESUMO

O enfisema subcutâneo consiste na entrada de ar nos tecidos moles e cavidades do corpo como resultado de um procedimento cirúrgico, patologia ou trauma. Em Odontologia representa uma condição rara. Os casos relatados geralmente têm relação com o uso de canetas de alta rotação, no entanto, também já foi descrito com o uso do jato de ar da seringa tríplice em procedimentos endodônticos e restauradores. Caracteriza-se pelo edema súbito e difuso que pode envolver a região periorbitária, bochechas, submandibular ou cervical. Este trabalho descreve um relato de caso clínico de enfisema subcutâneo em uma paciente submetida à remoção de enxerto autógeno de linha oblíqua mandibular com a utilização de caneta de alta rotação para reconstrução óssea de maxila previamente à colocação de implantes. No terceiro dia notou-se sensível melhora quanto ao inchaço periorbitário e regressão do mesmo nos dias subsequentes. Embora o enfisema subcutâneo seja pouco frequente e inócuo, normalmente se resolve sem sequelas de maneira espontânea dentro de alguns dias, pode migrar ao longo dos planos fasciais para estruturas profundas, podendo resultar em sérias complicações. O correto diagnóstico é fundamental a fim de evitar maiores complicações.


Subcutaneous emphysema is caused by the introduction of air into soft tissues and body cavities due to surgical procedure, disease or trauma. It is a rare condition in Dentistry. Cases of cutaneous emphysema are commonly associated with the use of high-speed handpieces, but cases associated with triple air syringes have also been described in endodontic and restorative procedures. It is characterized by a sudden and diffuse edema that may involve the periorbital region, cheeks, and submandibular and cervical regions. This study described a case report of subcutaneous emphysema that occurred during bone-graft harvesting from the oblique line for maxillary reconstruction prior to the placement of dental implants. Periorbital edema showed a marked improvement on the third postoperative day and gradual reduction on the subsequent days. Although subcutaneous emphysema is an uncommon and innocuous condition that usually resolves spontaneously in few days without leaving sequels, it may migrate along the fascial planes to deeper structures and result in serious complications. A correct diagnosis is extremely important to prevent major complications.


Assuntos
Humanos , Feminino , Adulto , Enfisema Subcutâneo/patologia , Equipamentos Odontológicos , Implantes Dentários , Transplante Ósseo/reabilitação , Tomografia Computadorizada por Raios X/instrumentação
9.
Rev. Soc. Odontol. La Plata ; 25(50): 21-26, jul. 2015. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-768629

RESUMO

Siendo la estética una condición prioritaria en la cultura occidental y uno de los parámetros objetivos de la misma la simetría, este trabajo analiza la relación de las líneas medias interincisal del maxilar superior e inferior con la línea media facial. La población analizada fueron los alumnos de tercero, cuarto y quinto año, durante los años 2011 y 2012, de la Facultad de Odontología UCALP-SOLP, con criterios de inclusión y exclusión. Se seleccionó una muestra aleatoria de 66 alumnos de ambos sexos, con una edad promedio (SD) de 22.85 (2.86) años. La coincidencia del maxilar superior respecto a las coincidencias del maxilar inferior son significativamente mayores, Pr (T>t)=0.00, con un nivel de significatividad del 5 por ciento. Las diferencias en el maxilar superior son significativamente menores a las del maxilar inferior, P<0.05).


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Assimetria Facial/diagnóstico , Assimetria Facial , Equipamentos Odontológicos , Equipamentos de Medição , Argentina , Estudos Transversais , Epidemiologia Descritiva , Estética Dentária , Reabilitação Bucal/métodos , Análise Estatística
10.
Braz. oral res. (Online) ; 29(1): 1-7, 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-777230

RESUMO

The present study aimed to assess the influence of curing distance on the loss of irradiance and power density of four curing light devices. The behavior in terms of power density of four different dental curing devices was analyzed (Valo, Elipar 2, Radii-Cal, and Optilux-401) using three different distances of photopolymerization (0 mm, 4 mm, and 8 mm). All devices had their power density measured using a MARC simulator. Ten measurements were made per device at each distance. The total amount of energy delivered and the required curing time to achieve 16 J/cm2 of energy was also calculated. Data were statistically analyzed with one-way analysis of variance and Tukey’s tests (p < 0.05). The curing distance significantly interfered with the loss of power density for all curing light devices, with the farthest distance generating the lowest power density and consequently the longer time to achieve an energy density of 16 J/cm2 (p < 0.01). Comparison of devices showed that Valo, in extra power mode, showed the best results at all distances, followed by Valo in high power mode, Valo in standard mode, Elipar 2, Radii-Cal, and Optilux-401 halogen lamp (p < 0.01). These findings indicate that all curing lights induced a significant loss of irradiance and total energy when the light was emitted farther from the probe. The Valo device in extra power mode showed the highest power density and the shortest time to achieve an energy density of 16 J/cm2 at all curing distances.


Assuntos
Luzes de Cura Dentária , Resinas Compostas/efeitos da radiação , Cura Luminosa de Adesivos Dentários/instrumentação , Cura Luminosa de Adesivos Dentários/métodos , Análise de Variância , Resinas Compostas/química , Equipamentos Odontológicos , Teste de Materiais , Polimerização/efeitos da radiação , Doses de Radiação , Equipamentos e Provisões para Radiação , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Fatores de Tempo
11.
Rev. ABENO ; 15(4): 37-44, 2015. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-880886

RESUMO

O estudo objetiva descrever e analisar a experiência de uma estratégia inovadora na disciplina de ergonomia odontológica, com uso de tecnologias digitais e método ativo de ensino-aprendizagem. Foi realizado um estudo observacional, descritivo em Laboratório de Ensaios Ergonômicos de um curso de Odontologia, sobre uma estratégia de aprendizado baseado em problemas (PBL) e emprego de filmagem de atendimento clínico. Participaram 20 alunos do último ano do curso de graduação e o estudo foi desenvolvido em duas etapas: na primeira, os acadêmicos tiveram aulas expositivas dialogadas sobre princípios ergonômicos na prática odontológica para introdução do assunto; na segunda etapa, os alunos foram divididos em dois grupos: um de observadores e outro de operadores para o atendimento a pacientes. Enquanto o grupo de operadores era filmado, o outro fazia observações em tempo real, em sala anexa, com visualização direta do ambiente de atendimento através de uma janela de vidro espelhado. O entendimento dos alunos e suas respostas aos estímulos para resolução de problemas ergonômicos foram verificados, permitindo ponderar sobre as vantagens do método de ensino. Observou-se boa participação dos acadêmicos nas atividades, com apontamento dos erros, resolução dos problemas posturais, de organização de bandeja e de todo o processo de trabalho. Os alunos corrigiam sua postura durante os atendimentos realizados após as primeiras observações, mantendo-as mais adequadas durante o trabalho. Em conclusão, a metodologia empregada, aliando a aprendizagem baseada em problemas e o uso de tecnologias digitais foi importante no ensino da ergonomia odontológica (AU).


This study aimed to describe and analyze an innovative strategy in the discipline of dental ergonomics, using digital technologies and active method of teaching-learning. An observational, descriptive study was performed in an Ergonomic Testing Laboratory, using the Problem Based Learning (PBL) strategy. The clinical care sessions were registered in film. Twenty undergraduate students participated and the study was developed in two stages: first, the students had a lecture on ergonomic principles in dental practice for introduction of the subject; in the second stage, they were divided into two groups, one of observers and the second of operators to patient care. While the latter group was filmed, the other made observations in real time, in an adjacent room, with direct visualization of the care environment through a mirrored glass window. There was good participation in academic activities, pointing errors, and resolution of postural problems, tray organization and the entire work process. Students corrected his stance during the care provided after the first observations, keeping the most suitable for the job. In conclusion, the strategy combining the problem-based learning and the use of digital technologies was important in the dental ergonomic education (AU).


Assuntos
Humanos , Equipamentos Odontológicos/estatística & dados numéricos , Educação em Odontologia , Ergonomia , Aprendizagem Baseada em Problemas/métodos , Brasil , Estudo Observacional , Riscos Ocupacionais
12.
Actas odontol ; 11(2): 35-42, dic.2014.
Artigo em Espanhol | LILACS | ID: lil-789794

RESUMO

En estos artículos los autores presentan una nueva línea de instrumentos de precisión usados en el procedimiento de laboratorio para la preparación de modelos set-up, corrección de modelos set-up y cirugía de modelos de acuerdo con el plan de tratamiento ortodóncico y quirúrgico. Se describen en este artículo el Set-Up Model Maker (SUM), el Occlusal Plane Reference (OPR) y el Surgical Model Accuracy Device (SMAD), y se explica su utilización a través del tratamiento de un caso clínico con clase III esquelética y mordida abierta...


In these articles the authors introduce a new line of precision instruments used in the laboratory procedure for set-up models preparation, set-up models correction and model surgery according to the orthodontic and surgery treatment plan. The Set-Up Model Maker (SUM), the Occlusal Plane Reference (OPR) and the Surgical Model Accuracy Device (SMAD) are described in this article, and its use is explained through the case report of a treatment of a skeletal class III case with open bite...


Assuntos
Humanos , Feminino , Adulto Jovem , Má Oclusão de Angle Classe III/reabilitação , Má Oclusão de Angle Classe III/terapia , Ortodontia Corretiva/instrumentação , Ortodontia Corretiva/métodos , Equipamentos Odontológicos , Equipamentos de Laboratório
13.
Odonto (Säo Bernardo do Campo) ; 22(43/44): 29-42, jan.-dez.2014. tab, graf
Artigo em Português | LILACS | ID: lil-790517

RESUMO

O custo dos materiais faz parte do cálculo do valor dos honorários odontológicos. As resinas compostas são materiais usualmente utilizados em restaurações dentárias diretas de dentes posteriores. O objetivo desse trabalho foi determinar e analisar o valor total do custo dos materiais de biossegurança utilizados em restaurações dentárias diretas em resina composta. O cálculo dos custos foi baseado no método de sistema de custeio variável. A lista dos materiais foi obtida por meio de consulta a uma banca juízes e baseada nos padrões de excelência comprovados na literatura para atendimento em equipe. Os valores dos materiais foram obtidos de uma média dos valores consultados no mercado fornecedor. O custo encontrado para a biossegurança foi de R$.8,85. Desse valor, os equipamentos de proteção individual (EPI) descartáveis para a equipe e paciente representaram 56,72%. Os valores encontrados podem ser utilizados no cálculo do valor final do procedimento restaurador, auxiliando na gestão de serviços odontológicos públicos ou privados...


The cost of the materials is part of the calculation of the value of dental fees. The composite resins are materials commonly used in direct posterior dental restorations. The aim of this study was to determine and to assess the total value of the cost of the biosafety materials used in composite resin posterior dental restorations. The calculation of costs was based on the method of variable costing system. A list of the materials was obtained by a panel of experts and based on the excellence standards established in the literature for dental team care. The values of the materials were obtained from an average of the values founded in the supplier market. The founded cost was R$.8.85 (in Brazilian current coin) for biosafety materials. Of this value, the personal protective equipment (PPE) disposable products for the team and patient accounted for 56.72 %. These values might be used in the calculation of the final value of the restorative procedure, aiding in the management of public or private dental care services...


Assuntos
Humanos , Equipamentos Odontológicos/economia , /economia , Resinas Compostas/química , Restauração Dentária Permanente/economia , Custos e Análise de Custo , Equipamento de Proteção Individual/economia , Valores de Referência
14.
Rev. Mus. Fac. Odontol. B.Aires ; 28(46): 3-5, dic. 2014. ilus
Artigo em Espanhol | LILACS | ID: lil-754626

RESUMO

La historia no es desechable como basura en los cestos del olvido. La utilidad inmediata que pretende el niño, y más de un odontólogo, es un falso concepto. No disponemos de toda la información necesaria para una tarea inmediata. Sumamos los datos pasados, agregamos nuestro propio aporte y ahí sí estamos listos para actuar.


Assuntos
História Antiga , História do Século XVIII , Equipamentos Odontológicos/história , História da Odontologia , Odontólogos/história
15.
Full dent. sci ; 5(20): 653-657, jul.-set. 2014. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-737458

RESUMO

Este artigo objetivou comparar, radiograficamente, a confiabilidade do Novapex® e do Propex II® no procedimento de Odontometria. O comprimento de trabalho de 30 elementos dentários foi determinado pela técnica radiográfica e pela localização foraminal eletrônica. Uma lima tipo K #15 foi introduzida em cada canal radicular, após preparo cervical, e quando da indicação do ápice dentário no painel de cada um dos aparelhos foi feita uma tomada radiográfica. A análise das imagens foi feita com o programa ImageTool3.00, a fim de serem comparados, entre os dispositivos, os comprimentos obtidos desde o final da lima ao ligamento periodontal. A análise dos dados se deu com o programa Statistica v.8.0. O teste de Wilcoxon revelou valores de p=0,305 e p= 0,823 quanto às medidas feitas nos diferentes intervalos de tempo entre o Novapex® e o Propex II®, respectivamente. A confiabilidade na detecção do forame apical foi de 76,6% para o Novapex e 70% para o Propex II, com tolerância de ± 0,5 mm. Contudo, quando comparados ao teste de Wilcoxon, não se observou diferença (p=0,687). A correlação entre os métodos, pelo teste de Spearman, indicou valor de p=0,091 e r=0,33. Os localizadores apicais se mostraram confiáveis ao que se destinam, sem diferenças estatisticamente significativas quando comparadas as performances de ambos na Odontometria.


This article aimed to compare the reliability of Novapex and Propex II in the Odontometry procedure by analyzing radiographs. The working length of 30 teeth was determined by the radiographic technique and by the electronic foramen localization. A K-type file #15 was introduced in each canal, and after cervical preparation, when the apex localization was indicated in the device's panel, an x-ray was made. The analysis of the images was performed with the program ImageTool 3.00, in order to compare the devices regarding the lengths obtained since the end of the file and the periodontal ligament. The data analysis was done with the program Statistica v.8.0. The Wilcoxon test revealed values of p=0.305 and p= 0.823 on the measures taken at different time intervals between the Novapex and the Propex II, respectively. The reliability in locating the apical foramen was 76.6% to the Novapex and 70% to the Propex II, with tolerance of ± 0.5 mm. However, when compared by Wilcoxon test there was no difference (p=0.687). The correlation between methods, by Spearman's test, indicated value of p=0.091 and r=0.33. Apex locators proved to be efficient without significant statistical difference when their performances in the Odontometry were compared.


Assuntos
Humanos , Ápice Dentário/cirurgia , Equipamentos Odontológicos , Odontometria/métodos , Radiografia Dentária/instrumentação , Endodontia , Estatísticas não Paramétricas
17.
Dent. press endod ; 4(1): 15-20, jan.-abr. 2014. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-722795

RESUMO

Introdução: o emprego de tomadas radiográficas tornou-se o método mais utilizado para a determinação do comprimento de trabalho, mesmo sendo amplamente reconhecido que a radiografia apresenta limitações. Com o intuito de se tornar cada vez mais precisa a identificação desse limite, têm sido desenvolvidos aparelhos eletrônicos que viabilizem, de maneira eficiente, a determinação do comprimento de trabalho. Objetivo: comparar in vitro a eficácia de dois localizadores apicais eletrônicos: o Root ZX e Apex DSP. Métodos: após a realização da abertura coronária e preparo dos terços cervical e médio do canal radicular, uma lima do tipo Kerr foi inserida no canal até a borda mais cervical do forame apical. Na sequência, os dentes foram incluídos em recipientes contendo alginato, juntamente com o grampo labial do localizador apical eletrônico, para a determinação do comprimento do dente com os aparelhos Root ZX e Apex DSP. Resultados: a comparação entre as medidas obtidas demonstrou uma precisão de 87,5% para o Root ZX, contra 77,5% do Apex DSP, não representando uma diferença estatisticamente significativa. Conclusão: o método eletrônico mostrou-se eficaz, representando uma alternativa satisfatória para a obtenção de um correto comprimento de trabalho.


Assuntos
Humanos , Equipamentos Odontológicos , Endodontia , Odontometria , Obturação do Canal Radicular/instrumentação , Preparo de Canal Radicular/instrumentação , Análise Estatística , Ápice Dentário , Tratamento do Canal Radicular/instrumentação
18.
Dent. press endod ; 4(1): 46-50, jan.-abr. 2014. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-722799

RESUMO

Introdução: radiografias intrabucais são uma importante ajuda investigativa na detecção de alterações na raiz dentária, incluindo fraturas radiculares verticais (FRV). Objetivo: avaliar a capacidade de radiografias convencionais e digitais, ortogonais e dissociadas para detectar FRV em dentes que apresentam diferentes condições do canal radicular. Métodos: sessenta dentes foram divididos em três grupos, considerando-se a condição do canal (não obturado, obturado com guta-percha e obturado com guta-percha e pino metálico). Em cada grupo, dez dentes foram artificialmente fraturados e dez dentes (controles), não foram fraturados. Realizaram-se radiografias convencionais (Kodak), e digitais (placas de fósforo – VistaScan Durr Dental), ortogonais e horizontalmente dissociadas. Usando um teste cego, três observadores calibrados realizaram avaliações em quatro tempos distintos. Valores modais foram utilizados para calcular a sensibilidade, especificidade e acurácia. A área sob a curva ROC (aucROC), e intervalos de confiança (IC ), foram usados para comparar o desempenho entre os sistemas radiográficos, bem como a influência de imagens ortogonais e combinadas (ortogonal mais dissociadas). Resultados: radiografias combinadas (ortogonal + dissociadas), apresentaram maior aucROC para ambas as imagens convencionais e digitais. Os ICs mostraram diferenças estatisticamente significativas entre as radiografias convencionais ortogonais e digitais combinadas (IC: 0,403-0,697 e 0,767-0,967, respectivamente). Além disso, quando apenas incidências ortogonais foram consideradas, radiografias digitais proporcionaram melhores resultados do que as convencionais (IC: 0,622-0,878 e 0,403-0,697, respectivamente). Conclusão: a forte tendência de melhores resultados dos testes de diagnóstico proporcionados pelas radiografias digitais sugere que o sistema digital, utilizando projeções combinadas, é mais apropriado para investigar FRV do que o convencional


Assuntos
Equipamentos Odontológicos , Diagnóstico por Imagem , Fraturas dos Dentes/diagnóstico , Radiografia Dentária , Radiografia Dentária Digital , Radiografia Dentária/métodos , Traumatismos Dentários
19.
Bauru; s.n; 2014. 218 p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-737475

RESUMO

O público infantil, na faixa etária de 0 - 5 anos, ainda é pouco assistido no que se refere aos recursos de acomodação para atendimento odontopediátrico. No mercado brasileiro o que se encontra disponível para esta finalidade, são produtos pouco funcionais para as crianças de zero a trinta e seis meses e que não atendem às exigências mínimas de adequação ergonômica, seja para o bom desempenho dos profissionais, ou para conforto, segurança e bem estar à criança. Este relatório de tese apresenta a pesquisa e desenvolvimento da maca infantil para atendimento odontopediátrico, sob a ótica do design aplicado à saúde, cujas bases se estruturaram nos conceitos de ergonomia, usabilidade e emotion design, com o objetivo de propor um equipamento adequado às características psicofísicas do público usuário. A pesquisa se desenvolveu sob duas vertentes de usuários pacientes e profissionais, observando os impactos psicofísicos, nesses dois públicos, da relação interface X usuário. Esta pesquisa ofereceu as prerrogativas para especificar os requisitos de projeto do design da maca, observando as necessidades evidenciadas para identificar as funções que a nova maca deverá desempenhar. O resultado apresentado exibe uma estrutura morfológica semelhante a da cadeira odontológica para adultos, porém seu dimensionamento é correspondente e apropriado ao público infantil de 0 - 5 anos. A proposta final foi incrementada com acessórios, cujas funções são de ajustar a posição da criança na da maca, oferecer os apoios necessários para acomodação confortável do pescoço e dos membros inferiores, além de proporcionar uma contenção confortável de movimentos bruscos do tronco, membros inferiores e cabeça, a fim de garantir a segurança da criança durante o seu atendimento. As cores empregadas têm objetivo lúdico e de adequação psicodinâmica ao contexto de uso da maca, para favorecer o comportamento colaborativo da criança durante o atendimento, além de contribuir para o desempenho...


Children in the age group from 0-5 years are still poorly assisted in what concerns suitable accommodation resources for pediatric dental care. The products available to this audience in the Brazilian market are little functional to the age group of 0-36 months. These products fail to meet minimum requirements for ergonomic adjustment in what concerns the professional performance or the childs welfare and safety. This research presents research and development of a stretcher for pediatric dental care, under the viewpoint of healthcare design. This kind of design is based upon ergonomics concepts, usability and emotion design. The aim is to present an equipment suitable to the psychophysics features of the target audience. The present research was developed considering both the professional and the patient approach. Psychophysics impact of interface versus user on both audiences were observed. It also propounds the prerogatives to establish the project requirements for the stretcher design, observing the identified needs in order to identify the functions this new stretcher should perform. The result exhibits a morphological structure similar to the adult targeted stretcher but its dimensioning is suitable and adequate to the age group of 0-5 years old. The final proposal was incremented with accessories whose functions are to adjust childs position in the stretcher, and to offer the necessary rests for neck and legs comfortable accommodation and, finally, to provide a comfortable contention of abrupt movements of the trunk, legs and head, in order to ensure the childs safety during its attendance. Colors were employed with a ludic and psychodynamics purpose, considering its application context and to favor a collaborative behavior of the child. In order to provide a safe and comfortable performance of the professional, the stretcher offers a pedal operated height adjustment and resources for its diminution and expansion therefore making it easier...


Assuntos
Humanos , Recém-Nascido , Lactente , Pré-Escolar , Equipamentos Odontológicos , Desenho de Equipamento , Cuidados Médicos , Lepidium/normas , Antropometria , Ergonomia , Valores de Referência , Reprodutibilidade dos Testes
20.
Rev. Mus. Fac. Odontol. B.Aires ; 27(45): 28-29, dic. 2013. ilus
Artigo em Espanhol | LILACS | ID: lil-722374

RESUMO

Se describe el desarrollo de dispositivos dentales precursores del torno dental. El ingenio de odontólogos del siglo XIX trata de lograr un movimiento más rápido al usar el instrumental para tallado


Assuntos
Odontólogos , Equipamentos Odontológicos/história , História da Odontologia , Reino Unido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA