Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros










Filtros aplicados

Intervalo de ano de publicação
1.
Braz. j. microbiol ; 49(1): 128-137, Jan.-Mar. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889212

RESUMO

ABSTRACT We developed a loop-mediated isothermal amplification (LAMP) assay for the detection of Y. pestis by targeting the 3a sequence on chromosome. All 11 species of the genus Yersinia were used to evaluate the specificity of LAMP and PCR, demonstrating that the primers had a high level of specificity. The sensitivity of LAMP or PCR was 2.3 or 23 CFU for pure culture, whereas 2.3 × 104 or 2.3 × 106 CFU for simulated spleen and lung samples. For simulated liver samples, the sensitivity of LAMP was 2.3 × 106 CFU, but PCR was negative at the level of 2.3 × 107 CFU. After simulated spleen and lung samples were treated with magnetic beads, the sensitivity of LAMP or PCR was 2.3 × 103 or 2.3 × 106 CFU, whereas 2.3 × 105 or 2.3 × 107 CFU for magnetic bead-treated liver samples. These results indicated that some components in the tissues could inhibit LAMP and PCR, and liver tissue samples had a stronger inhibition to LAMP and PCR than spleen and lung tissue samples. LAMP has a higher sensitivity than PCR, and magnetic bead capture of DNAs could remarkably increase the sensitivity of LAMP. LAMP is a simple, rapid and sensitive assay suitable for application in the field or poverty areas.


Assuntos
Humanos , Peste/microbiologia , DNA Bacteriano/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Magnetismo/métodos , Yersinia pestis/isolamento & purificação , Yersinia pestis/classificação , Yersinia pestis/genética , DNA Bacteriano/isolamento & purificação , DNA Bacteriano/química , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade , Separação Imunomagnética , Primers do DNA/genética , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Magnetismo/instrumentação
3.
Braz. j. microbiol ; 45(4): 1255-1261, Oct.-Dec. 2014. ilus, tab
Artigo em Inglês | LILACS | ID: lil-741275

RESUMO

Magnetotactic bacteria (MTB) are of considerable interest because of their importance in the manufacture of various bioinspired materials. In order to find out the status of magnetotactic bacteria at three different sediment in Czech Republic, samples collected from both standing and running freshwaters were subjected to molecular diversity analysis by using 16S rRNA gene approach. Total community DNA from sediment sample was isolated and used for PCR, cloning and sequence analysis. Of the 24 analyzed sequences, six clones are closely related to Magnetobacterium sp. affiliated with the Nitrospira phylum which showed the dominance of Magnetobacterium phylotypes in the sample. This study will provide useful insight about the community structure of MTB in this particular geographical region. However more detailed and specific studies are warranted in order to properly assess the community structure of MTB's in fresh water sediments.


Assuntos
Bactérias/classificação , Bactérias/isolamento & purificação , Sedimentos Geológicos/microbiologia , Fenômenos Fisiológicos Bacterianos , Bactérias/genética , Análise por Conglomerados , República Tcheca , DNA Bacteriano/química , DNA Bacteriano/genética , DNA Ribossômico/química , DNA Ribossômico/genética , Água Doce/microbiologia , Locomoção , Magnetismo , Dados de Sequência Molecular , Filogenia , Reação em Cadeia da Polimerase , /genética , Análise de Sequência de DNA
4.
Rev. bras. anestesiol ; 64(3): 205-214, May-Jun/2014. tab
Artigo em Inglês | LILACS | ID: lil-715669

RESUMO

A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia), special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary.


Marcapasso (MP) é um sistema que consiste em um gerador de impulso e eletrodo ou eletrodos que conduzem o impulso elétrico para o coração do paciente. Códigos de MP e cardioversor desfibrilador implantável (CDI) foram criados para descrever o tipo de MP ou CDI implantado. Indicações para a implantação de MP e CDI foram descritas pelo Colégio Americano de Cardiologistas. Alguns MPs têm interruptores de circuitos magneticamente operados incorporados, porém a aplicação magnética pode causar efeitos adversos graves; portanto, os dispositivos devem ser considerados programáveis, salvo conhecimento em contrário. Quando um paciente portador de dispositivo é submetido a qualquer procedimento (com ou sem anestesia), precauções especiais devem ser tomadas, incluindo história/exame físico focados; perguntas sobre o MP antes e após o procedimento, uso de medicamentos de emergência/estimulação e desfibrilação temporárias; reprogramação do MP e desabilitação de certas funções, caso necessário; monitoração dos distúrbios metabólicos e eletrolíticos e evitar certos medicamentos e equipamentos que podem interferir na função do MP. Se houver previsão de interações com o dispositivo, considerar a suspensão do procedimento até que a fonte de interferência tenha sido eliminada ou controlada e todas as medidas corretivas devem ser tomadas para garantir o funcionamento adequado do MP. Após o procedimento, frequência e ritmo cardíacos devem ser monitorados continuamente, medicamentos e equipamentos de emergência devem ser mantidos de prontidão e pode ser necessário consultar um cardiologista ou serviço de MP-CDI.


El marcapasos (MP) es un sistema que consiste en un generador de impulso y un electrodo o electrodos que conducen el impulso eléctrico hacia el corazón del paciente. Se han creado códigos de MP y de desfibrilador automático implantables para describir el tipo de cada uno. El Colegio Norteamericano de Cardiólogos han descrito indicaciones para la implantación de MP y de desfibrilador automático implantable. Algunos MP tienen interruptores de circuitos magnéticos incorporados, sin embargo, la aplicación magnética puede causar efectos adversos graves; por tanto, los dispositivos deben ser considerados programables, salvo que se tenga un conocimiento diferente. Cuando un paciente portador de dispositivo se somete a cualquier procedimiento (con o sin anestesia), se deben tomar precauciones especiales, incluyendo historial/examen físico dirigidos; preguntas sobre el MP antes y después del procedimiento, uso de medicamentos de urgencia/estimulación y desfibrilación temporales; reprogramación del MP e inhabilitación de ciertas funciones del mismo, si fuere preciso; monitorización de los trastornos metabólicos y electrolíticos y evitar ciertos medicamentos y equipos que puedan interferir con la función del MP. Si hay alguna previsión de interacción con el dispositivo, considerar la suspensión del procedimiento hasta que la fuente de la interferencia haya sido eliminada o controlada. Se deben tomar todas las medidas correctivas para garantizar el funcionamiento adecuado del MP. Después del procedimiento, la frecuencia y el ritmo cardíacos deben ser monitorizados continuamente, y deben estar preparados los medicamentos y equipos de urgencia; y si fuera necesario, consultar con un cardiólogo o con el servicio de MP- desfibrilador automático implantable.


Assuntos
Humanos , Anestésicos/administração & dosagem , Desfibriladores Implantáveis , Marca-Passo Artificial , Anestesia/métodos , Desenho de Equipamento , Falha de Equipamento , Magnetismo
5.
Einstein (Säo Paulo) ; 11(2): 234-236, Apr.-June 2013. ilus
Artigo em Inglês | LILACS | ID: lil-679270

RESUMO

Accidental ingestion of magnetic foreign bodies has become more common due to increased availability of objects and toys with magnetic elements. The majority of them traverse the gastrointestinal system spontaneously without complication. However, ingestion of multiple magnets may require surgical resolution. The case of an 18-month girl who developed an intestinal fistula after ingestion of two magnets is reported.


A ingestão acidental de corpo estranho magnético tem sido mais observada, devido à disponibilidade cada vez maior de brinquedos e objetos com imãs. A maioria deles é eliminada pelo trato digestivo espontaneamente. Porém, a ingestão de duas ou mais peças podem desencadear situações de resolução cirúrgica. Relatamos aqui o caso de uma menina de 18 meses que desenvolveu fístula intestinal após a ingestão de 2 peças imantadas.


Assuntos
Humanos , Criança , Criança , Corpos Estranhos , Fístula Intestinal/etnologia , Jogos e Brinquedos/lesões , Magnetismo
6.
Medisan ; 15(12)dic. 2011. ilus
Artigo em Espanhol | LILACS | ID: lil-616428

RESUMO

Se exponen los elementos fundamentales encontrados en artículos originales, así como en sitios web especializados, actualizados y validados como confiables respecto al tema de los campos electromagnéticos. En el artículo se analizan algunos de los mecanismos físicos (primarios) de los campos electromagnéticos de extremada baja frecuencia (ELF-EMF por sus siglas en inglés de extremely low frequency-electromagnetic field) sobre las estructuras biológicas, pero también las evidencias sobre los efectos biológicos (secundarios) de estos campos, ejercidos sobre determinados tipos de tejidos, que pudieran explicar los resultados con el empleo de esta terapéutica en pacientes afectados por psoriasis.


The fundamental elements found in original articles, as well as in specialized web sites, updated and validated as reliable regarding the topic of the electromagnetic fields are exposed. Some of the physical mechanisms (primary) of the extremely low frequency electromagnetic fields (ELF-EMF extremely low frequency electromagnetic field, according to its initials in English) on the biological structures are analyzed in the paper. Evidences on the biological effects (secondary) of these fields on certain types of tissues that could explain the results with the use of this therapy in the treatment of patients affected by psoriasis are also analyzed.


Assuntos
Humanos , Campos Eletromagnéticos , Magnetismo , Psoríase/terapia
7.
Braz. j. infect. dis ; 15(6): 547-552, Nov.-Dec. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-610525

RESUMO

Nucleic acid amplification testing (NAT) was recently recommended by Brazilian legislation and has been implemented at some blood banks in the city of São Paulo, Brazil, in an attempt to reduce blood-born transmission of human immunodeficiency virus (HIV) and hepatitis C virus. OBJECTIVE: Manual magnetic particle-based extraction methods for HIV and HCV viral nucleic acids were evaluated in combination with detection by reverse transcriptase - polymerase chain reaction (RT-PCR) one-step. METHODS: Blood donor samples were collected from January 2010 to September 2010, and minipools of them were submitted to testing. ELISA was used for the analysis of anti-HCV/HIV antibodies. Detection and amplification of viral RNA was performed using real-time PCR. RESULTS: Out of 20.808 samples screened, 53 samples (29 for HCV and 24 for HIV) were confirmed as positive by serological and NAT methods. CONCLUSION: The manual magnetic bead-based extraction in combination with real-time PCR detection can be used to routinely screen blood donation for viremic donors to further increase the safety of blood products.


Assuntos
Humanos , HIV , Hepacivirus/isolamento & purificação , Magnetismo/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/sangue , Bancos de Sangue , Ensaio de Imunoadsorção Enzimática , HIV , Anticorpos Anti-HIV/sangue , Infecções por HIV/prevenção & controle , Hepacivirus/genética , Hepacivirus/imunologia , Anticorpos Anti-Hepatite C/sangue , Hepatite C/prevenção & controle , Tamanho da Partícula , Reação em Cadeia da Polimerase Via Transcriptase Reversa
8.
São Paulo; s.n; 2011. 74 p. ilus, tab, graf. (BR).
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-866075

RESUMO

Os magnetos de Neodímio Ferro Boro (Nd2Fe14B) apresentam excelentes propriedades magnéticas e compatibilidade biológica, embora sejam frágeis e possuam baixa resistência à corrosão. As forças de atração magnética de magnetos de terras raras têm sido empregadas em sistemas de retenção, principalmente associadas aos implantes osseointegráveis, em próteses bucais e próteses faciais, bem como em aparelhos ortodônticos. Este estudo avalia o comportamento das forças de repulsão magnética, em função do volume e comprimento do eixo magnético, quando submetidos a afastamentos, de modo que esta propriedade física seja empregada em odontologia. Vinte e quatro corpos de prova, com um ou dois pares de magnetos de Nd2Fe14B, com diferentes formas e volumes variados, foram submetidos a ensaio mecânico para mensuração das forças de repulsão magnética, em condições de afastamentos que variaram entre 0,0 e 20,0 mm. Os dados observados mostram que, considerando-se uma mesma área superficial de polo, a força de repulsão magnética varia em função do comprimento do eixo magnético. Os dados relativos ao afastamento foram submetidos a análise de variância (p0,05), tendo-se observado que o aumento da distância entre os magnetos diminui significantemente a força de repulsão magnética na maioria dos corpos de prova. No afastamento 0,0 mm as forças magnéticas de repulsão dos subgrupos mantêm uma sequência crescente a partir do subgrupo de menor volume de magnetos ao subgrupo de maior volume de magnetos, os quais permanecem nessa sequência nos afastamentos iniciais


A força de repulsão magnética gerada por magnetos pequenos varia menos em função do aumento do afastamento. Conclui-se que a variação da força de repulsão magnética, dada a mesma área superficial de polo, apresenta uma relação direta com o volume e com o eixo magnético onde, quanto maior o volume ou o comprimento do eixo magnético, maior a força de repulsão magnética. A relação direta entre volume e força de repulsão magnética não se altera frente aos afastamentos inicais, tendendo a se tornar imensurável com o aumento da distância. A força de repulsão magnética mantém uma relação inversa com a distância entre os pares de magnetos. Este ensaio mecânico indica que a força de repulsão magnética apresenta, assim como a força de atração magnética, uma curva hiperbólica de redução frente ao aumento do afastamento.


Neodymium Iron Boron (Nd2Fe14B) magnets exhibit excellent magnetic properties and demonstrate biological compatibility, despite of their fragility and low resistance to corrosion. The magnetic attraction forces of rare earth magnets have been used in retention systems mainly associated with osseointegrated implants, in oral and facial prostheses, as well as orthodontic appliances. This study evaluates the repulsion forces of magnets, varying volume and length of magnetic axis when subjected to vertical distance, in order to assess the usefulness of such physical property in clinical situations. Twenty-four specimens, with one or two pairs of Nd2Fe14B magnets, presenting different shapes and various volumes, were subjected to mechanical testing so as to measure magnetic repulsion forces, under conditions of vertical pole face separation ranging from 0.0 to 20.0 mm. Repulsive magnetic force varies depending on the length of the magnetic axis, when considering the same surface area of a pole. Analysis of Variance - (p0.05) indicated that by increasing the distance between the pairs of magnets, magnetic repulsion force significantly reduces in most of the specimens. Starting at a 0.0 mm distance, the magnetic repulsion forces keep an enhancing sequence from lower to higher magnetic volume, holding these characteristics during initials distances. Repulsion magnetic forces generated by small magnets varies less as the distance increases.


The results indicate the repulsion magnetic force variation, fixing the same pole surface area, presenting a direct relationship between volume and magnetic axis, since the increase of the volume or of the magnetic axis length leads to a higher magnetic repulsive force. The relationship between volume and magnetic repulsion force does not vary at initial distance. Nevertheless, when such distance increases, the force between the magnets significantly decreases. The magnetic repulsion force holds an inverse relationship with respect to the distance between magnets pairs. This mechanical test indicates that the magnetic repulsion force, as well the magnetic attraction force, present a hyperbolic curve of force reduction due to the increasing vertical distance.


Assuntos
Boro/análise , Ferro/análise , Magnetismo , Metais Terras Raras/análise , Neodímio/análise , Propriedades Físicas , Próteses e Implantes , Teste de Materiais/métodos
9.
Biol. Res ; 43(2): 243-250, 2010. ilus
Artigo em Inglês | LILACS | ID: lil-567539

RESUMO

The effect of extremely low frequency magnetic felds (50 Hz, 0.5 mT) - ELF-MF, on phosphate metabolism has been studied in the isolated ganglions of the garden snail Helix pomatia, after 7 and 16 days of snail exposure to ELF-MF. The infuence of ELF-MF on the level of phosphate compounds and intracellular pH was monitored by 31P NMR spectroscopy. Furthermore, the activity of enzymes involved in phosphate turnover, total ATPases, Na+/K+-ATPase and acid phosphatase has been measured. The exposure of snails to the ELF-MF for the period of 7 days shifted intracellular pH toward more alkaline conditions, and increased the activity of investigated enzymes. Prolonged exposure to the ELF-MF for the period of 16 days caused a decrease of PCr and ATP levels and decreased enzyme activity, compared to the 7-day treatment group. Our results can be explained in terms of: 1. increase in phosphate turnover by exposure to the ELF-MF for the period of 7 days, and 2. adaptation of phosphate metabolism in the nervous system of snails to prolonged ELF-MF exposure.


Assuntos
Animais , Campos Eletromagnéticos , Caracois Helix/metabolismo , Magnetismo , Sistema Nervoso/metabolismo , Fosfatos/metabolismo
10.
West Indian med. j ; 58(2): 87-91, Mar. 2009. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-672448

RESUMO

An attempt has been made to localize ranitidine loaded microspheres in the stomach by magnetic means. Since ranitidine undergoes metabolism by microbial enzymes in the intestine, it is ideal to localize the controlled drug delivery system within the stomach to get uniform release and absorption of the drug for the desired period. Gelatin magnetic microspheres loaded with 9.1, 17.9, 26.3 and 33.3% w/w of ranitidine hydrochloride were prepared by emulsification-cross linking technique. The formulated microspheres were characterized by magnetite content, particle size and in vitro drug release. The efficiency of microspheres to be localized in the stomach is tested in vivo in rats. The prepared microspheres were spherical and had a size distribution from 10 to 105 µm. The in vitro study revealed the capability of microspheres to release the drug over a period of 8 to 12 hours, depending on drug loading. The release was found to be diffusion controlled and followed fickian diffusion principle. The in vivo study showed the efficiency of microspheres to be retained in the stomach over a period of 8 hours.


Se ha hecho el intento por localizar las microesferas cargadas de ranitidina en el estómago mediante medios magnéticos. Como que la ranitidina experimenta metabolismo mediante enzimas microbianas en el intestino, resulta ideal localizar el sistema de administración del medicamento controlado dentro del estómago para alcanzar la liberación y absorción uniformes del medicamento por el período deseado. Microesferas de gelatina magnética cargadas con 9.1, 17.9, 26.3 y 33.3% p/p de hidrocloruro de ranitidina, fueron preparadas mediante una técnica de emulsificación-entrecruzamiento. Las microesferas formuladas se caracterizaron por su contenido de magnetita, el tamaño de las partículas y la liberación del medicamento in vitro. La eficiencia de las microesferas a ser localizadas en el estómago se prueba in vivo en ratas. Las microesferas preparadas eran esféricas y tenían una distribución de tamaño de 10 a 105 µm. El estudio in vitro reveló la capacidad de las microesferas para liberar la droga en un período de 8 a 12 horas, en dependencia de la carga de la droga. Se halló que la liberación estaba sujeta difusión controlada y seguía la ley de Fick para la difusión. El estudio in vivo mostró la eficiencia de las microesferas para ser retenidas en el estómago por un período de 8 horas.


Assuntos
Animais , Ratos , Antiulcerosos/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Magnetismo , Microesferas , Ranitidina/administração & dosagem , Antiulcerosos/metabolismo , Gelatina , Tamanho da Partícula , Ratos Wistar , Ranitidina/metabolismo , Estômago/metabolismo
11.
Acta odontol. latinoam ; 21(1): 77-83, 2008. ilus, graf
Artigo em Inglês | LILACS | ID: lil-546727

RESUMO

El objetivo del presente trabajo fue evaluar a diferentes tiemposen un modelo experimental en tibias de rata, el efecto de la exposición breve a campos electromagnéticos pulsantes(PEMF, del inglés Pulsed lectroMagnetic Fields) sobre la reparación y formación ósea peri-implantaria. Se utilizaron 60 ratas Wistar. En la cresta tibial derecha de cada animal se colocó un implante roscado de titanio comercialmentepuro y en la cresta tibial izquierda se efectuó una osteotomía. La mitad de los animales fueron tratados con PEMF (72 mT, 50Hz) dos veces por día (30 minutos por sesión), y la otra mitadconstituyó el grupo control. Las ratas se sacrificaron a los 5, 10 y 20 días postcirugía (n=10 por grupo). La mitad de las tibias derechas se descalcificaron,incluyeron en parafina y tiñeron con hemato xilina-eosina, mientras que al resto se las incluyó en metil-metacrilato y se realizaron cortes por desgaste. Se evaluó el área de osificación, el perímetro y el diámetro de las osteotomías mediante un analizadorde imágenes. Para evaluar la osificación peri-implante se obtuvo el porcentaje de osificación. Al día 10 el índice del área de osificación fue significativamentemayor en el grupo PEMF que en el control (190,6±13,6 vs. 147,9±6,3; p=0,012). Al día 20, las osteotomías del grupo PEMF estaban, en su mayor parte remodeladas. El porcentaje de osificación fue mayor en el grupo PEMF respecto al control (51,9±10,4 por ciento vs. 36±12.1 por ciento; p=0,018). La breve estimulación electromagnética pulsante diaria sería un tratamiento promisorio para facilitar la reparación ósea y peri-implantaria.


Assuntos
Ratos , Animais , Terapias Complementares , Osso e Ossos/cirurgia , Implantes Experimentais , Magnetismo , Regeneração Óssea/efeitos da radiação , Cicatrização/efeitos da radiação , Osteotomia , Ratos Wistar , Tíbia/cirurgia
12.
Rev. méd. Chile ; 134(10): 1315-1319, oct. 2006. ilus
Artigo em Espanhol | LILACS | ID: lil-439925

RESUMO

Accidental ingestion of foreign bodies in childhood is an increasing problem. Although many of them can be treated with an expectant approach, allowing their passage through the gastrointestinal tract, magnets must be extracted, due to their high rate of complications, such as perforation. We report three patients that ingested magnets. A five year-old male was operated with an extensive ulceration of the jejunum, where a cylindrical magnet was extracted. A four year-old female was operated with a perforation of the anterior wall of the stomach and three magnets were extracted from the peritoneal cavity. A four year-old female, was transferred from a hospital where she had been operated for a magnet ingestion that provoked three perforations in the small bowel.


Assuntos
Pré-Escolar , Feminino , Humanos , Masculino , Corpos Estranhos/etiologia , Perfuração Intestinal/etiologia , Jejuno/lesões , Jogos e Brinquedos , Acidentes Domésticos , Parede Abdominal/patologia , Ingestão de Alimentos , Endoscopia Gastrointestinal , Corpos Estranhos , Corpos Estranhos/cirurgia , Migração de Corpo Estranho/complicações , Perfuração Intestinal , Perfuração Intestinal/cirurgia , Magnetismo/instrumentação
13.
An. acad. bras. ciênc ; 78(3): 463-474, Sept. 2006. ilus, graf
Artigo em Inglês | LILACS | ID: lil-433714

RESUMO

Nós relatamos a aplicação de holografia não-axial e microscopia eletrônica de alta resolução para estudar os hábitos cristalinos de magnetossomos e a microestrutura magnética de dois morfotipos de cocos de bactérias magnetotáticas coletadas em uma lagoa salobra em Itaipu, Brasil. Itaipu-1, o organismo cocóide maior, contémduas cadeias separadas de magnetossomos atipicamente grandes; os cristais dos magnetossomos possuem projeções aproximadamente quadradas, comprimentos deaté 250 nm e são ligeiramente alongados na direção [111] (razão largura/comprimento de aproximadamente 0.9).Os cristais dos magnetossomos em Itaipu-3 possuemcomprimentos até 120 nm, maior alongamento na direção [111] (largura/comprimento ~ 0.6), e proeminentes facetas nas extremidades. Os resultados mostram que os hábitos cristalinos dos magnetossomos em Itaipu-1 eItaipu-3 são relacionados, diferindo apenas nos tamanhos relativos das suas faces cristalinas. Em ambos os casos, os cristais são alinhados com seus eixos de alongamento [111] paralelos à direção da cadeia. Em Itaipu-1, mas não em Itaipu-3, o posicionamento cristalográfico, perpendicular à direção [111], de cristais sucessivos na cadeia de magnetossomos parece estar sobre controlebiológico. Enquanto os magnetossomos grandes em Itaipu-1 são monodomínios magnéticos metaestáveis, em Itaipu-3 eles são monodomínios magnéticos permanentes como na maioria das bactérias.


Assuntos
Bactérias/ultraestrutura , Bactérias/química , Cristalização , Holografia , Magnetismo , Microscopia Eletrônica de Transmissão
14.
Arq. bras. oftalmol ; 68(5): 667-673, set.-out. 2005. ilus, tab
Artigo em Português | LILACS | ID: lil-417820

RESUMO

OBJETIVOS: Avaliação microscópica dos sinais da reação inflamatória causada pela fixação de implante orbitário (ímã, recoberto por ouro). MÉTODOS: Estudo experimental em 54 coelhas adultas, divididas em três grupos de 18, com 3 subgrupos de 6, avaliação com uma, três e seis semanas de pós-operatório. Fixação, no rebordo inferior da órbita, de implante (ímã e ouro) por meio de cola, parafuso ou fio inabsorvível (Mersilene 5.0®). As órbitas contralaterais (sem implante) compuseram o grupo-controle. RESULTADOS: Sinais histológicos de reação inflamatória à fixação orbitária do implante foram observados, com cianoacrilato, parafuso, ou sutura inabsorvível (Mersilene 5.0®), até a sexta semana pós-operatória, com predomínio do processo inflamatório crônico e fibrótico cicatricial, sem demonstrar diferenças estatisticamente significativas na maior parte dos casos. CONCLUSÃO: O exame histopatológico demonstrou, na maior parte das órbitas com e sem implante, presença de reação inflamatória aguda e crônica até a sexta semana pós-operatória, com predomínio de processo inflamatório crônico e fibrótico cicatricial, sem demonstrar, na maior parte dos casos, diferenças estatisticamente significante entre os grupos experimental e controle.


Assuntos
Animais , Feminino , Coelhos , Reação a Corpo Estranho/patologia , Ouro , Magnetismo/efeitos adversos , Órbita/cirurgia , Implantes Orbitários/efeitos adversos , Doença Aguda , Doença Crônica , Fibrose/patologia , Órbita/patologia , Fatores de Tempo
15.
Arq. bras. oftalmol ; 67(3): 519-525, maio-jun. 2004. ilus, tab
Artigo em Português | LILACS | ID: lil-361707

RESUMO

OBJETIVOS: Avaliação clínica dos sinais da reação inflamatória de fixação de implante orbitário (ímã recoberto por ouro) e avaliação macroscópica de sua resistência aos fluidos orgânicos. MÉTODOS: Estudo experimental em 54 coelhas adultas, divididas em três grupos de 18, com 3 subgrupos de 6 de acordo com o material usado para fixação, avaliação com uma, três e seis semanas de pós-operatório. Fixação, no rebordo inferior da órbita, de implante (ímã e ouro) por meio de cola ou parafuso ou fio inabsorvível (Mersilene 5.0®). As órbitas contralaterais (sem implante) compuseram o grupo-controle. Medidas da resistência à tração tangencial do implante fixado. RESULTADOS: Sinais clínicos de reação inflamatória à fixação orbitária do implante foram observados com cianoacrilato, parafuso, ou sutura inabsorvível (Mersilene 5.0®), até a sexta semana de pós-operatório, sendo mais intensa no grupo F (fixação com fio). A força de tração de 80 gf, independentemente do tipo de fixação, não produziu arrancamentos em 94,5 por cento dos implantes na primeira semana, 100 por cento na terceira semana e em 94,5 por cento dos casos na sexta semana. CONCLUSAO: Sinais clínicos de reação inflamatória do implante e sua fixação foram observados com cianoacrilato ou parafuso ou sutura inabsorvível (Mersilene 5.0®) até a sexta semana pós-operatória, sendo mais intensa no grupo F (fio). A resistência do implante aos fluídos orgânicos mostrou falha em 9,3 por cento (implante com dano).


Assuntos
Animais , Feminino , Coelhos , Ouro , Implantes Orbitários/efeitos adversos , Magnetismo , Nistagmo Patológico/cirurgia
16.
Rev. bras. psiquiatr ; 26(2): 100-102, jun. 2004. tab
Artigo em Português | LILACS | ID: lil-385231

RESUMO

OBJETIVO: A Estimulação Magnética Transcraniana (EMT) tem se mostrado útil como forma terapêutica para a depressão. Este artigo avalia os resultados da aplicação da EMT de baixa freqüência, duas vezes por semana, durante quatro semanas, em 10 pacientes com depressão, não responsivos ou intolerantes à utilização de antidepressivos. MÉTODOS: Trata-se de um estudo descritivo, ou não controlado, do tipo série de casos. Para diagnosticar a depressão, foram utilizados os critérios do DSM-IV. Com o intuito de avaliar uma possível melhora, utilizamos a escala de Hamilton-17 itens em três momentos: no início, meio e final do tratamento. Para análise estatística dos resultados, utilizamos o teste x², de Friedman. RESULTADOS: Foi observada melhora > 50 por cento na escala em cinco pacientes e > 75 por cento em três destes ao longo de todo o tratamento. CONCLUSÕES: O emprego da EMT de baixa freqüência, aplicada duas vezes por semana, pode ser seguro, prático e eficaz no tratamento da depressão, como um coadjuvante ao antidepressivo. Porém, não podemos afirmar se o efeito clínico apresentado se deve a uma potencialização dos antidepressivos ou a um efeito direto da EMT, já que esta não foi testada isoladamente.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Depressão/terapia , Magnetismo/uso terapêutico , Escalas de Graduação Psiquiátrica , Resultado do Tratamento
17.
Rev. bras. psiquiatr ; 26(2): 131-134, jun. 2004. tab
Artigo em Português | LILACS | ID: lil-385236

RESUMO

A Estimulação Magnética Transcraniana (no original, TMS, Transcranial Magnetic Stimulation) é uma nova técnica que tem sido utilizada para o tratamento de transtornos neuropsiquiátricos, principalmente depressão. É um tratamento que utiliza um aparelho estimulador que cria um campo magnético variável no tempo, aplicado sobre o crânio através de uma bobina de estimulação. O principal risco deste tratamento são as convulsões acidentais. A TMS é utilizada na maior parte dos estudos com estímulos subliminares. Convulsões podem ocorrer acidentalmente, especialmente quando os estímulos ultrapassam os parâmetros de segurança. Neste artigo, é feita uma detalhada revisão dos oito casos em que houve convulsões acidentais com o uso da TMS. Também são descritos os possíveis mecanismos de indução das convulsões e as características dos pacientes com maior risco de convulsões acidentais.


Assuntos
Humanos , Masculino , Feminino , Depressão/terapia , Magnetismo/efeitos adversos , Estimulação Física/métodos , Convulsões/etiologia , Estimulação Física/efeitos adversos , Fatores de Risco
18.
Arq. neuropsiquiatr ; 62(1): 21-25, mar. 2004. tab, graf
Artigo em Inglês | LILACS | ID: lil-357829

RESUMO

OBJETIVO: investigar o efeito de três meses de estimulação magnética transcraniana repetitiva (EMTr) de baixa freqüência, na epilepsia de difícil controle. MÉTODO: Cinco pacientes (quatro homens, uma mulher, idades entre 6 e 50 anos), participaram do estudo; suas crises epilépticas não puderam ser controlados por tratamento medicamentoso e não tinham indicação cirúrgica; a EMTr foi realizada duas vezes por semana durante três meses, sendo que os pacientes anotaram o número diário de crises neste período, assim como nos três meses anteriores e posteriores ao tratamento. A aplicação da EMTr foi feita no vértex com bobina circular, com intensidade 5 por cento abaixo do limiar motor. Durante as sessões de EMTr, 100 estímulos (5 séries de 20 estímulos, com um minuto de intervalo entre as séries) foram realizadas na freqüência de 0,3 Hz. RESULTADOS: A média diária de crises (MDC) decresceu em três pacientes e aumentou em dois durante o uso da EMTr; um destes casos foi tratado somente por um mês; o melhor resultado foi encontrado em um paciente com displasia cortical focal (redução de 43,09 por cento na MDC). Em todo o grupo de pacientes, houve decréscimo significativo na MDC de 22,8 por cento (p<0,01). CONCLUSAO: Embora o tratamento prolongado com a EMTr seja seguro e tenha sido registrado decréscimo moderado da MDC em um grupo de pacientes com epilepsia de difícil controle, respostas individuais de pacientes foram imprevisíveis e a relevância clínica deste método é provavelmente baixa. Nossos dados sugerem, contudo, que pacientes com lesões corticais focais podem ser beneficiar deste novo tipo de tratamento. Estudos futuros devem se concentrar neste grupo de pacientes.


Assuntos
Pessoa de Meia-Idade , Criança , Adolescente , Adulto , Humanos , Masculino , Feminino , Epilepsia , Magnetismo , Estimulação Elétrica , Eletroencefalografia , Fatores de Tempo , Resultado do Tratamento
19.
Rev. Asoc. Odontol. Argent ; 91(3): 237-241, jun.-jul. 2003. ilus
Artigo em Espanhol | LILACS | ID: lil-345499

RESUMO

Los sistemas de barras proporcionan mejores resultados en la confección de sobredentaduras. Los diseños de barras Hader o Dolder son los más utilizados. Podemos confeccionar barras sobre pilares transepiteliales o barras directamente sobre los implantes, utilizando elementos mecanizados o calcinables. Sobre las barras se prefiere colocar la mínima retención posible para la sobredentadura. Para el éxito del tratamiento es fundamental la pasividad de la barra


Assuntos
Retenção em Prótese Dentária , Revestimento de Dentadura , Prótese Dentária Fixada por Implante/métodos , Planejamento de Prótese Dentária , Encaixe de Precisão de Dentadura , Reembasamento de Dentadura , Ligas de Ouro , Magnetismo , Ajuste de Prótese , Resinas Acrílicas/química , Titânio
20.
Ortodoncia ; 67(133): 8-13, ene.-jun. 2003. graf
Artigo em Espanhol | LILACS | ID: lil-345475

RESUMO

Objetivos: el fin perseguido por esta investigación es actualizar y reconceptualizar el ciclo masticatorio con un estudio preorotóncico. Se prevee dar con nuevos conocimientos acerca del funcionamiento de la masticación y su influencia en la aparición y desarrollo de los trastornos temporomandibulares. Teniendo en cuenta estas premisas se pretende evaluar: a) objetivos generales: desarrollar protocolos de diagnóstico para lograr enfoques destinados a fomentar el control del paciente, manteniendo o incrementando su funcionamiento masticatorio sano. b) Objetivos específicos: determinar la existencia de patologías temporomandibulares a partir de los ciclos masticatorios. Poder desarrollar métodos diagnóstico preventivos para poder detectar tempranamente las afecciones temporomandibulares, patología que ha llevado en estos últimos tiempos a investigaciones que buscan solucionar estos problemas en la población. Implementar como herramienta de diagnóstico y verificación postratamiento, la evaluación de la eficacia masticatoria, movimientos y actividad muscular


Assuntos
Humanos , Masculino , Feminino , Mandíbula/fisiologia , Mastigação/fisiologia , Síndrome da Disfunção da Articulação Temporomandibular/diagnóstico , Argentina , Articulação Temporomandibular/fisiopatologia , Protocolos Clínicos , Colorimetria , Deglutição/fisiologia , Magnetismo , Má Oclusão/diagnóstico , Má Oclusão/prevenção & controle , Ortodontia Preventiva , Síndrome da Disfunção da Articulação Temporomandibular/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA