IEEE Trans Biomed Eng ; 71(6): 1926-1936, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38241109

RESUMEN

OBJECTIVE: The objective of this work is to introduce and demonstrate the effectiveness of a novel sensing modality for contact detection between an off-the-shelf aspiration catheter and a thrombus. METHODS: A custom robotic actuator with a pressure sensor was used to generate an oscillatory vacuum excitation and sense the pressure inside the extracorporeal portion of the catheter. Vacuum pressure profiles and robotic motion data were used to train a support vector machine (SVM) classification model to detect contact between the aspiration catheter tip and a mock thrombus. Validation consisted of benchtop accuracy verification, as well as user study comparison to the current standard of angiographic presentation. RESULTS: Benchtop accuracy of the sensing modality was shown to be 99.67%. The user study demonstrated statistically significant improvement in identifying catheter-thrombus contact compared to the current standard. The odds ratio of successful detection of clot contact was 2.86 (p = 0.03) when using the proposed sensory method compared to without it. CONCLUSION: The results of this work indicate that the proposed sensing modality can offer intraoperative feedback to interventionalists that can improve their ability to detect contact between the distal tip of a catheter and a thrombus. SIGNIFICANCE: By offering a relatively low-cost technology that affords off-the-shelf aspiration catheters as clot-detecting sensors, interventionalists can improve the first-pass effect of the mechanical thrombectomy procedure while reducing procedural times and mental burden.


Asunto(s)
Trombosis , Vacio , Humanos , Trombosis/diagnóstico por imagen , Diseño de Equipo , Catéteres , Máquina de Vectores de Soporte , Robótica/instrumentación , Robótica/métodos
2.
IEEE Sens J ; 22(4): 3585-3594, 2022 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36034075

RESUMEN

Safe human-robot interaction requires robots endowed with perception. This paper presents the design of a multi-modal sensory array for continuum robots, targeting operation in semi-structured confined spaces with human users. Active safety measures are enabled via sensory arrays capable of simultaneous sensing of proximity, contact, and force. Proximity sensing is achieved using time-of-flight sensors, while contact force is sensed using Hall effect sensors and embedded magnets. The paper presents the design and fabrication of these sensors, the communication protocol and multiplexing scheme used to allow an interactive rate of communication with a high-level controller, and an evaluation of these sensors for actively mapping the shape of the environment and compliance control using gestures and contact with the robot. Characterization of the proximity sensors is presented with considerations of sensitivity to lighting, color, and texture conditions. Also, characterization of the force sensing is presented. The results show that the multi-modal sensory array can enable pre and post-collision active safety measures and can also enable user interaction with the robot. We believe this new technology allows for increased safety for human-robot interaction in confined and semi-structures spaces due to its demonstrated capabilities of detecting impending collision and mapping the environment along the length of the robot. Future miniaturization of the electronics will also allow possible integration in smaller continuum and soft robots.

3.
Soft Robot ; 4(3): 241-250, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29182083

RESUMEN

Soft robotic devices have significant potential for medical device applications that warrant safe synergistic interaction with humans. This article describes the optimization of an implantable soft robotic system for heart failure whereby soft actuators wrapped around the ventricles are programmed to contract and relax in synchrony with the beating heart. Elastic elements integrated into the soft actuators provide recoiling function so as to aid refilling during the diastolic phase of the cardiac cycle. Improved synchronization with the biological system is achieved by incorporating the native ventricular pressure into the control system to trigger assistance and synchronize the device with the heart. A three-state electro-pneumatic valve configuration allows the actuators to contract at different rates to vary contraction patterns. An in vivo study was performed to test three hypotheses relating to mechanical coupling and temporal synchronization of the actuators and heart. First, that adhesion of the actuators to the ventricles improves cardiac output. Second, that there is a contraction-relaxation ratio of the actuators which generates optimal cardiac output. Third, that the rate of actuator contraction is a factor in cardiac output.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Corazón/fisiología , Robótica/instrumentación , Animales , Fenómenos Biomecánicos , Ingeniería Biomédica , Gasto Cardíaco , Modelos Animales de Enfermedad , Insuficiencia Cardíaca/fisiopatología , Humanos , Contracción Miocárdica , Porcinos
4.
Sci Robot ; 2(12)2017 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-33157903

RESUMEN

Previous soft robotic ventricular assist devices have generally targeted biventricular heart failure and have not engaged the interventricular septum that plays a critical role in blood ejection from the ventricle. We propose implantable soft robotic devices to augment cardiac function in isolated left or right heart failure by applying rhythmic loading to either ventricle. Our devices anchor to the interventricular septum and apply forces to the free wall of the ventricle to cause approximation of the septum and free wall in systole and assist with recoil in diastole. Physiological sensing of the native hemodynamics enables organ-in-the-loop control of these robotic implants for fully autonomous augmentation of heart function. The devices are implanted on the beating heart under echocardiography guidance. We demonstrate the concept on both the right and the left ventricles through in vivo studies in a porcine model. Different heart failure models were used to demonstrate device function across a spectrum of hemodynamic conditions associated with right and left heart failure. These acute in vivo studies demonstrate recovery of blood flow and pressure from the baseline heart failure conditions. Significant reductions in diastolic ventricle pressure were also observed, demonstrating improved filling of the ventricles during diastole, which enables sustainable cardiac output.