Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Prev Cardiol ; 30(15): 1599-1607, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-37067048

RESUMEN

AIMS: The added value of advanced practitioner nurse (APN) care after ablation of atrial fibrillation (AF) is unknown. The present study investigates the impact of APN-led care on AF recurrence, patient knowledge, lifestyle, and patient satisfaction. METHODS AND RESULTS: Sixty-five patients undergoing AF ablation were prospectively randomized to usual care (N = 33) or intervention (N = 32) group. In addition to usual care, the intervention consisted of an educational session, three consultations spread over 6 months and telephone accessibility coordinated by the APN. Primary outcome was the AF recurrence rate at 6-month follow-up. Secondary outcomes were lifestyle factors (alcohol intake, exercise, BMI, smoking), patient satisfaction and AF knowledge measured at 1 and 6 months between groups and within each group. Study demographics at 1 month were similar, except AF knowledge was higher in the intervention group (8.6 vs. 7, P = 0.001). At 6 months, AF recurrence was significantly lower in the intervention group (13.5 vs. 39.4%, P = 0.014). Between groups, patient satisfaction and AF knowledge were significantly higher in the intervention group, respectively, 9.4 vs. 8.7 (P < 0.001) and 8.6 vs. 7.0 out of 10 (P < 0.001). Within the intervention group, alcohol intake decreased from 3.9 to 2.6 units per week (P = 0.031) and physical activity increased from 224.4 ± 210.7 to 283.8 ± 169.3 (P = 0.048). No changes occurred within the usual care group. Assignment to the intervention group was the only protective factor for AF recurrence [Exp(B) 0.299, P = 0.04] in multivariable-adjusted analysis. CONCLUSION: Adding APN-led care after ablation of AF improves short-term clinical outcome, patient satisfaction and physical activity and decreases alcohol intake.


The present study investigates the added value of advanced practitioner nurse (APN)-led care consisting of an educational session, three consultations spread over 6 months and telephone accessibility coordinated by the APN in patients after ablation of atrial fibrillation (AF). Main findings are The addition of nurse-led care after ablation of AF improves short-term clinical outcome, patient satisfaction and physical activity and decreases alcohol intake.Our study shows that integrating nurse-led care in the post-AF ablation setting is a relatively simple to implement, low-cost intervention with a major impact on patient outcomes and quality of care. These findings encourage including nurse-led care into routine AF ablation follow-up.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Rol de la Enfermera , Resultado del Tratamiento , Satisfacción del Paciente , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
2.
J Pers Med ; 13(2)2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36836420

RESUMEN

BACKGROUND: One of the reasons that high-frequency jet ventilation (HFJV) is used is due to the near immobility of thoracic structures. However, no study has quantified the movements of cardiac structures during HFJV compared with normal mechanical ventilation. METHODS: After ethical approval and written informed consent, we included 21 patients scheduled for atrial fibrillation ablation in this prospective crossover study. Each patient was ventilated with both normal mechanical ventilation and HFJV. During each ventilation mode, displacements of the cardiac structure were measured by the EnSite Precision mapping system using a catheter placed in the coronary sinus. RESULTS: The median [Q1-Q4] displacement was 2.0 [0.6-2.8] mm during HFJV and 10.5 [9.3-13.0] mm during conventional ventilation (p < 0.000001). CONCLUSION: This study quantifies the minimal movement of cardiac structures during HFJV compared to standard mechanical ventilation.

3.
Europace ; 20(3): 548-554, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28340057

RESUMEN

Aims: The therapeutical management of atrial fibrillation (AF) in the setting of Brugada syndrome (BS) might be challenging as many antiarrhythmic drugs (AADs) with sodium channel blocking properties might lead to to the development of ventricular arrhythmias. This study sought to evaluate the clinical outcome in a consecutive series of patients with BS having undergone pulmonary vein (PV) isolation by means of radiofrequency (RF) or cryoballoon (CB) ablation and the efficacy of catheter ablation for preventing inappropriate interventions delivered by implantable cardioverter defibrillators (ICD) on a 3-year follow up. Methods and results: Twenty-three consecutive patients with BS (13 males; mean age was 47 ± 18 years) having undergone PV isolation for drug-resistant paroxysmal AF were enrolled. Eleven patients (48%) had an ICD implanted of whom four had inappropriate shocks secondary to rapid AF. Over a mean follow-up period of 35.0 ± 25.4 months (median 36 months) the freedom from AF recurrence after the index PV isolation procedure was 74% without AADs. Patients with inappropriate ICD interventions for AF did not present futher ICD shocks after AF ablation. No major complications occurred. Conclusion: Catheter ablation is a valid therapeutic choice for patients with BS and paroxysmal AF considering the high success rates, the limitations of the AADs and the safety of the procedure, and it should be taken into consideration especially in those patients presenting inappropriate ICD shocks due to rapid AF.


Asunto(s)
Fibrilación Atrial/cirugía , Síndrome de Brugada/complicaciones , Ablación por Catéter , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Adulto , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/parasitología , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/terapia , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Am J Cardiol ; 120(8): 1332-1337, 2017 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-28823479

RESUMEN

Some previous studies have proposed the electrocardiographic Tpeak-Tend (TpTe) as a possible predictor of ventricular arrhythmic events in patients with Brugada syndrome (BrS). We sought to analyze the association between the parameters of repolarization dispersion (TpTe, TpTe/QT, TpTe dispersion, QTc, and QTd) and ventricular fibrillation/sudden cardiac death in a large cohort of patients with type 1 BrS. A total of 448 consecutive patients with BrS (men 61%, age 45 ± 16 years) with spontaneous (n = 96, 21%) or drug-induced (n = 352, 79%) type 1 electrocardiogram were retrospectively included. At the time of the diagnosis or during a mean follow-up of 93 ± 47 months (median 88 months), 43 patients (9%) documented ventricular arrhythmias. No significant difference was observed in TpTe, TpTe/QT, maximum TpTe, and TpTe dispersion between asymptomatic patients and those with syncope and malignant arrhythmias. TpTe/QT ratio did not also significantly differ between patients with ventricular fibrillation/sudden cardiac death and those asymptomatic ones. In conclusion, TpTe was not significantly prolonged in those patients with type 1 BrS presenting with unexplained syncope or malignant arrhythmic events during follow-up.


Asunto(s)
Síndrome de Brugada/complicaciones , Electrocardiografía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular/diagnóstico , Síndrome de Brugada/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología
5.
Am J Cardiol ; 120(2): 223-229, 2017 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-28532773

RESUMEN

Data evaluating the impact of the periprocedural administration of novel oral anticoagulants (NOACs) on complications in the setting of pulmonary vein (PV) isolation using cryoballoon (CB) is limited. In the present study, our aim was to analyze procedural characteristics and incidence of complications in those patients who underwent CB ablation for atrial fibrillation and the impact of NOACs on adverse events compared with vitamin K antagonists (VKAs). Consecutive patients with drug resistant atrial fibrillation who underwent PV isolation by CB as index procedure were retrospectively included in our analysis. In group I, 290 of 454 patients (63.9%) received VKAs (warfarin: n = 222 and acenocoumarol: n = 68), and in group II, 164 of 454 patients (36.1%) were treated with NOACs (rivaroxaban: n = 71; dabigatran: n = 60; and apixaban: n = 33). Age was significantly higher in the group II (62.8 ± 9.7 vs 58.6 ± 11.3; p <0.001). During the study period, 454 consecutive patients (male 71%, age 60.1 ± 10.9 years) were enrolled. Major complications occurred in 9 patients (2.0%): peripheral vascular complications were observed in 6 patients (1.3% per procedure), persistent phrenic nerve palsy occurred in 2 (0.4%), and transient ischemic attacks in 1 (0.2%). In both groups, the incidence of major complications was similar (group I [VKAs]: 7 patients [2.4%] vs group II [NOACs]: 2 patients [1.2%]; p = 0.5). In conclusion, CB ablation is a safe procedure for PV isolation and is associated with low complication rates. The incidence of adverse events in PV isolation using the second-generation CB with the periprocedural administration of NOACs is not significantly different than VKA treatment.


Asunto(s)
Técnicas de Ablación/efectos adversos , Anticoagulantes/administración & dosificación , Fibrilación Atrial/terapia , Criocirugía/efectos adversos , Complicaciones Posoperatorias/epidemiología , Accidente Cerebrovascular/prevención & control , Vitamina K/antagonistas & inhibidores , Administración Oral , Antitrombinas/administración & dosificación , Fibrilación Atrial/complicaciones , Bélgica/epidemiología , Dabigatrán/administración & dosificación , Relación Dosis-Respuesta a Droga , Quimioterapia Combinada , Inhibidores del Factor Xa/administración & dosificación , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Periodo Intraoperatorio , Italia/epidemiología , Masculino , Persona de Mediana Edad , Pronóstico , Pirazoles/administración & dosificación , Piridinas/administración & dosificación , Piridonas/administración & dosificación , Estudios Retrospectivos , Rivaroxabán/administración & dosificación , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Tasa de Supervivencia/tendencias , Tiazoles/administración & dosificación , Factores de Tiempo
6.
Heart Rhythm ; 14(3): 322-328, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27871986

RESUMEN

BACKGROUND: The achievement of -40°C within the first 60 seconds during cryoenergy applications has proven to independently predict durable pulmonary vein (PV) isolation in the setting of second-generation cryoballoon (CB-A; Medtronic, Minneapolis, MN) ablation. OBJECTIVE: We sought to evaluate a strategy based on the attainment of the specific parameter of -40°C within the first 60 seconds during cryoenergy applications in the setting of CB-A ablation without the use of an inner lumen mapping catheter (Achieve, Medtronic) for the visualization of real-time recordings. METHODS: A total of 52 patients having undergone CB ablation for paroxysmal atrial fibrillation (AF) between 1 February 2015 and 30 June 2015 who underwent a temperature-guided approach based on achieving -40°C within 60 seconds without real-time recordings (wire group) were compared with a cohort of 52 propensity score-matched patients having undergone CB ablation performed with an inner lumen mapping catheter (Achieve group). All PVs were checked for electrical isolation at the end of the procedure with a circular mapping catheter in the wire group. RESULTS: Electrical isolation could be obtained in all patients in the Achieve group and in 99% of PVs in the wire group. Freedom from AF without antiarrhythmic drugs at a mean follow-up of 12.4 ± 3.0 months did not significantly differ between both groups (85% vs 88%, respectively; P = .56). CONCLUSION: A temperature-guided approach based on achieving -40°C within 60 seconds is effective in producing PV isolation and affords freedom from AF at 12-month follow-up in 85% of patients affected by paroxysmal AF after a 3-month blanking period.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/tratamiento farmacológico , Bélgica , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Frío , Criocirugía/instrumentación , Criocirugía/métodos , Resistencia a Medicamentos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Cirugía Asistida por Computador/métodos
7.
Am Heart J ; 155(4): 648-53, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18371471

RESUMEN

BACKGROUND: Late thrombosis is the major safety concern of drug-eluting stents, but its incidence in common clinical practice remains controversial to date, especially beyond the first year after stent implantation. We sought to investigate the incidence, clinical consequences, and risk factors of late thrombosis after drug-eluting stent implantation. METHODS: Consecutive patients (N = 604) who received > or = 1 paclitaxel-eluting stent(s) (PES) between June 2003 and February 2005 at our institution were enrolled. Clinical characteristics and major outcomes were reviewed to detect cases and predictors of late and very late definite PES thrombosis (LDT) of PES, as currently defined by the Academic Research Council. RESULTS: During long-term follow-up (median 34.3 months, IQR 8.6), 17 cases of LDT were noted (cumulative incidence 2.8%, 95% CI 1.7%-4.5%). Most of LDT were very late thromboses (14 cases, 82%). Late and very late definite PES thrombosis appeared at a steady rate (incidence density 1.1% patient-years). Late and very late definite PES thrombosis was related to a high risk of all-cause death (HR 3.2, 95% CI 1.3-7.9) and cardiac death (HR 6.0, 95% CI 2.3-15.6). Withdrawal of antiplatelet therapy, left ventricular ejection fraction, and average stent diameter per patient were independent predictors of LDT in multivariate analysis. CONCLUSIONS: Late and very late definite PES thrombosis may be more frequent in a real setting than anticipated by initial experimental and observational studies but is keeping with more recent scientific evidence. It seems to occur at a constant rate during long-term follow-up and is associated with a high risk of overall and cardiac death.


Asunto(s)
Enfermedad Coronaria/terapia , Trombosis Coronaria/epidemiología , Stents Liberadores de Fármacos/efectos adversos , Paclitaxel/administración & dosificación , Anciano , Enfermedad Coronaria/mortalidad , Reestenosis Coronaria/epidemiología , Esquema de Medicación , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Factores de Riesgo , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...