Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
J Clin Med ; 13(8)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38673468

RESUMEN

Background: One way to treat atrial fibrillation is through surgical ablation. However, the literature only provides information on patient follow-up results for up to 5 years. Methods: In order to assess long-term monitoring data over ten years, this retrospective study included 58 patients with paroxysmal or persistent atrial fibrillation who underwent Mini Maze surgical ablation at Santaros Clinics between 1 February 2009 and 1 June 2014. The follow-up time after surgery was 144 ± 48 months. We evaluated the absence of atrial fibrillation, echocardiographic and clinical parameters, and EHRA score. Results: Sinus rhythm remained in 69.4%, 75.5%, 55.6%, and 44.1% of patients with paroxysmal AF, and 68,2%, 59.1%, 50%, and 41.9% of patients with persistent AF (p = 0.681). In the post-operative period, one patient (1.7%) had a transient ischemic attack, and another patient (1.7%) had a thoracotomy for post-operative bleeding. A total of 20% of patients were diagnosed with a post-operative respiratory tract infection. EHRA scores showed that patients' quality of life improved after they underwent Mini Maze surgical ablation. Conclusions: Despite AF recurrences after surgery, quality of life remains better than before surgery, showing that Mini Maze surgery is an effective and safe second-line treatment method for atrial fibrillation.

2.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584468

RESUMEN

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Asunto(s)
Fibrilación Atrial , Catéteres Cardíacos , Ablación por Catéter , Venas Pulmonares , Recurrencia , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Diseño de Equipo , Técnicas Electrofisiológicas Cardíacas , Factores de Tiempo , Frecuencia Cardíaca , Potenciales de Acción
3.
Medicina (Kaunas) ; 59(11)2023 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-38004085

RESUMEN

Background and Objectives: Cryoablation is an established treatment method for atrial fibrillation (AF). We present the long-term results of cryoablation in 94 patients with paroxysmal and persistent AF treated in our center. Materials and Methods: This was an observational, retrospective study of 94 patients who underwent a cryoablation procedure for paroxysmal or persistent AF from 2015 to 2017. The follow up was 51 ± 3 months. The absence of arrhythmia was checked at 6, 12, 24, and 48 months after the procedure with 24 h Holter monitoring. We evaluated echocardiography parameters before and 48 months after cryoablation. The quality of life was assessed by calculating EHRA scores at each visit. Results: The mean history of pre-procedural AF duration was 55.3 ± 8.6 months. Paroxysmal AF was present in 42% of patients and persistent AF in 58%. Comparing the EHRA classes, a statistically significant difference was observed between the score assessed before the procedure and the score after one year, as well as when comparing the rates before the procedure and four years after the procedure (p < 0.000). The recurrence of AF was observed in 22.3% of patients 1 year after the procedure, in 26.6% of patients 2 years after the procedure, and in 34% of patients 4 years after the procedure; 9.3% of them were left in permanent AF. During the observation period, 28% of patients underwent a repeated pulmonary vein isolation procedure, and 6% of patients had a permanent pacemaker implanted. Five hematomas (5%) and one instance of phrenic nerve palsy (1%) were observed during the procedure. Conclusions: The rate of arrhythmia recurrence increased every year after cryoablation. Quality of life improved after the procedure, despite the recurrence of AF. A quarter of patients had to undergo a repeat pulmonary vein isolation procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Estudios de Seguimiento , Resultado del Tratamiento , Criocirugía/efectos adversos , Criocirugía/métodos , Calidad de Vida , Estudios Retrospectivos , Ablación por Catéter/métodos , Recurrencia
4.
Circ Arrhythm Electrophysiol ; 16(10): e012018, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37727989

RESUMEN

BACKGROUND: During electrophysiological mapping of tachycardias, putative target sites are often only truly confirmed to be vital after observing the effect of ablation. This lack of mapping specificity potentiates inadvertent ablation of innocent cardiac tissue not relevant to the arrhythmia. But if myocardial excitability could be transiently suppressed at critical regions, their suitability as targets could be conclusively determined before delivering tissue-destructive ablation lesions. We studied whether reversible pulsed electric fields (PFREV) could transiently suppress electrical conduction, thereby providing a means to dissect tachycardia circuits in vivo. METHODS: PFREV energy was delivered from a 9-mm lattice-tip catheter to the atria of 12 swine and 9 patients, followed by serial electrogram assessments. The effects on electrical conduction were explored in 5 additional animals by applying PFREV to the atrioventricular node: 17 low-dose (PFREV-LOW) and 10 high-dose (PFREV-HIGH) applications. Finally, in 3 patients manifesting spontaneous tachycardias, PFREV was applied at putative critical sites. RESULTS: In animals, the immediate post-PFREV electrogram amplitudes diminished by 74%, followed by 78% recovery by 5 minutes. Similarly, in patients, a 69.9% amplitude reduction was followed by 84% recovery by 3 minutes. Histology revealed only minimal to no focal, superficial fibrosis. PFREV-LOW at the atrioventricular node resulted in transient PR prolongation and transient AV block in 59% and 6%, while PFREV-HIGH caused transient PR prolongation and transient AV block in 30% and 50%, respectively. The 3 tachycardia patients had atypical atrial flutters (n=2) and atrioventricular nodal reentrant tachycardia. PFREV at putative critical sites reproducibly terminated the tachycardias; ablation rendered the tachycardias noninducible and without recurrence during 1-year follow-up. CONCLUSIONS: Reversible electroporation pulses can be applied to myocardial tissue to transiently block electrical conduction. This technique of pulsed field mapping may represent a novel electrophysiological tool to help identify the critical isthmus of tachycardia circuits.


Asunto(s)
Bloqueo Atrioventricular , Ablación por Catéter , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Animales , Porcinos , Técnicas Electrofisiológicas Cardíacas , Electrocardiografía , Nodo Atrioventricular , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
5.
Front Cardiovasc Med ; 10: 1160242, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37363094

RESUMEN

Background: Smartwatches are commonly capable to record a lead-I-like electrocardiogram (ECG) and perform a photoplethysmography (PPG)-based atrial fibrillation (AF) detection. Wearable technologies repeatedly face the challenge of frequent premature beats, particularly in target populations for screening of AF. Objective: To investigate the potential diagnostic benefit of six-lead ECG compared to single-lead ECG and PPG-based algorithm for AF detection of the wrist-worn device. Methods and results: From the database of DoubleCheck-AF 249 adults were enrolled in AF group (n = 121) or control group of SR with frequent premature ventricular (PVCs) or atrial (PACs) contractions (n = 128). Cardiac rhythm was monitored using a wrist-worn device capable of recording continuous PPG and simultaneous intermittent six-lead standard-limb-like ECG. To display a single-lead ECG, the six-lead ECGs were trimmed to lead-I-like ECGs. Two diagnosis-blinded cardiologists evaluated reference, six-lead and single-lead ECGs as "AF", "SR", or "Cannot be concluded". AF detection based on six-lead ECG, single-lead ECG, and PPG yielded a sensitivity of 99.2%, 95.7%, and 94.2%, respectively. The higher number of premature beats per minute was associated with false positive outcomes of single-lead ECG (18.80 vs. 5.40 beats/min, P < 0.01), six-lead ECG (64.3 vs. 5.8 beats/min, P = 0.018), and PPG-based detector (13.20 vs. 5.60 beats/min, P = 0.05). Single-lead ECG required 3.4 times fewer extrasystoles than six-lead ECG to result in a false positive outcome. In a control subgroup of PACs, the specificity of six-lead ECG, single-lead ECG, and PPG dropped to 95%, 83.8%, and 90%, respectively. The diagnostic value of single-lead ECG (AUC 0.898) was inferior to six-lead ECG (AUC 0.971) and PPG-based detector (AUC 0.921). In a control subgroup of PVCs, the specificity of six-lead ECG, single-lead ECG, and PPG was 100%, 96.4%, and 96.6%, respectively. The diagnostic value of single-lead ECG (AUC 0.961) was inferior to six-lead ECG (AUC 0.996) and non-inferior to PPG-based detector (AUC 0.954). Conclusions: A six-lead wearable-recorded ECG demonstrated the superior diagnostic value of AF detection compared to a single-lead ECG and PPG-based AF detection. The risk of type I error due to the widespread use of smartwatch-enabled single-lead ECGs in populations with frequent premature beats is significant.

6.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1786-1801, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37227340

RESUMEN

BACKGROUND: Because of its safety, "single-shot" pulsed field ablation (PFA) catheters have been developed for pulmonary vein isolation (PVI). However, most atrial fibrillation (AF) ablation procedures are performed with focal catheters to permit flexibility of lesion sets beyond PVI. OBJECTIVES: This study sought to determine the safety and efficacy of a focal ablation catheter able to toggle between radiofrequency ablation (RFA) or PFA to treat paroxysmal or persistent AF. METHODS: In a first-in-human study, a focal 9-mm lattice tip catheter was used for PFA posteriorly and either irrigated RFA (RF/PF) or PFA (PF/PF) anteriorly. Protocol-driven remapping was at ∼3 months postablation. The remapping data prompted PFA waveform evolution: PULSE1 (n = 76), PULSE2 (n = 47), and the optimized PULSE3 (n = 55). RESULTS: The study included 178 patients (paroxysmal/persistent AF = 70/108). Linear lesions, either PFA or RFA, included 78 mitral, 121 cavotricuspid isthmus, and 130 left atrial roof lines. All lesion sets (100%) were acutely successful. Invasive remapping of 122 patients revealed improvement of PVI durability with waveform evolution: PULSE1: 51%; PULSE2: 87%; and PULSE3: 97%. After 348 ± 652 days of follow-up, the 1-year Kaplan-Meier estimates for freedom from atrial arrhythmias were 78.3% ± 5.0% and 77.9% ± 4.1% for paroxysmal and persistent AF, respectively, and 84.8% ± 4.9% for the subset of persistent AF patients receiving the PULSE3 waveform. There was 1 primary adverse event-inflammatory pericardial effusion not requiring intervention. CONCLUSIONS: AF ablation with a focal RF/PF catheter allows efficient procedures, chronic lesion durability, and good freedom from atrial arrhythmias-for both paroxysmal and persistent AF. (Safety and Performance Assessment of the Sphere-9 Catheter and the Affera Mapping and RF/PF Ablation System to Treat Atrial Fibrillation; NCT04141007 and NCT04194307).


Asunto(s)
Técnicas de Ablación , Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía
7.
Front Cardiovasc Med ; 9: 869730, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35463751

RESUMEN

Background: Consumer smartwatches have gained attention as mobile health (mHealth) tools able to detect atrial fibrillation (AF) using photoplethysmography (PPG) or a short strip of electrocardiogram (ECG). PPG has limited accuracy due to the movement artifacts, whereas ECG cannot be used continuously, is usually displayed as a single-lead signal and is limited in asymptomatic cases. Objective: DoubleCheck-AF is a validation study of a wrist-worn device dedicated to providing both continuous PPG-based rhythm monitoring and instant 6-lead ECG with no wires. We evaluated its ability to differentiate between AF and sinus rhythm (SR) with particular emphasis on the challenge of frequent premature beats. Methods and Results: We performed a prospective, non-randomized study of 344 participants including 121 patients in AF. To challenge the specificity of the device two control groups were selected: 95 patients in stable SR and 128 patients in SR with frequent premature ventricular or atrial contractions (PVCs/PACs). All ECG tracings were labeled by two independent diagnosis-blinded cardiologists as "AF," "SR" or "Cannot be concluded." In case of disagreement, a third cardiologist was consulted. A simultaneously recorded ECG of Holter monitor served as a reference. It revealed a high burden of ectopy in the corresponding control group: 6.2 PVCs/PACs per minute, bigeminy/trigeminy episodes in 24.2% (31/128) and runs of ≥3 beats in 9.4% (12/128) of patients. AF detection with PPG-based algorithm, ECG of the wearable and combination of both yielded sensitivity and specificity of 94.2 and 96.9%; 99.2 and 99.1%; 94.2 and 99.6%, respectively. All seven false-positive PPG-based cases were from the frequent PVCs/PACs group compared to none from the stable SR group (P < 0.001). In the majority of these cases (6/7) cardiologists were able to correct the diagnosis to SR with the help of the ECG of the device (P = 0.012). Conclusions: This is the first wearable combining PPG-based AF detection algorithm for screening of AF together with an instant 6-lead ECG with no wires for manual rhythm confirmation. The system maintained high specificity despite a remarkable amount of frequent single or multiple premature contractions.

8.
Heart Rhythm O2 ; 3(1): 15-22, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35243431

RESUMEN

BACKGROUND: Early experience with a novel multielectrode saline-irrigated radiofrequency balloon (RFB) catheter with an integrated camera system found that it was safe and effective in performing single-shot pulmonary vein isolation (PVI) for atrial fibrillation. OBJECTIVE: The purpose of this study was to further assess potential treatment risks by looking for subclinical events. METHODS: The study was performed at 2 sites. Patients underwent PVI by RFB. A control group underwent conventional point-by-point radiofrequency ablation. Stroke scale questionnaire and brain magnetic resonance imaging (MRI) were performed before and after the ablation procedure, and esophageal endoscopy was performed after the procedure in RFB patients only. RESULTS: We enrolled 27 patients in the RFB group and 15 patients in the control group. The RFB and control groups were well matched [predominantly male: 62% vs 53%; CHA2DS2-VASc score: 1.9 ± 1.3 vs 1.5 ± 1.6; mean age 60 years in both groups]. All patients underwent successful ablation and completed study assessments. Clinically silent, new MRI diffusion weighted imaging cerebral lesions were observed in 8 patients (30%) in the RFB group and 1 patient (7%) in the control group, and 11 susceptibility weighted imaging lesions in the RFB group and 1 in the control group. Endoscopy showed a minor thermal injury in 1 patient in the RFB group. CONCLUSION: An increased rate of clinically silent cerebral events was seen in the RFB group. A low rate of esophageal thermal injury was observed.

9.
Artículo en Inglés | MEDLINE | ID: mdl-35239067

RESUMEN

Myocardial fibrosis in aortic stenosis is associated with worse survival following aortic valve replacement. We assessed myocardial fibrosis in severe AS patients, integrating echocardiographic, cardiovascular magnetic resonance (CMR) and histological data. A total of 83 severe AS patients (age 66.4 ± 8.3, 42% male) who were scheduled for surgical AVR underwent CMR with late gadolinium enhancement and T1 mapping and global longitudinal strain analysis. Collagen volume fraction was measured in myocardial biopsies (71) that were sampled at the time of AVR. Results. CVF correlated with imaging and serum biomarkers of LV systolic dysfunction and left side chamber enlargement and was higher in the sub-endocardium compared with midmyocardium (p<0.001). CVF median values were higher in LGE-positive versus LGE-negative patients [28.7% (19-33) vs 20.7% (15-30), respectively, p=0.040]. GLS was associated with invasively (CVF; r=-0.303, p=0.013) and non-invasively (native T1; r=-0.321, p<0.05) measured myocardial fibrosis. GLS and native T1 correlated with parameters of adverse LV remodelling, systolic and diastolic dysfunction and serum biomarkers of heart failure and myocardial injury. Conclusion. Our data highlight the role of myocardial fibrosis in adverse cardiac remodelling in AS. GLS has potential as a surrogate marker of myocardial fibrosis, and high native T1 and low GLS values differentiated patients with more advanced cardiac remodelling.

10.
JACC Cardiovasc Interv ; 15(1): 93-104, 2022 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-34991828

RESUMEN

OBJECTIVES: This study sought to evaluate the 30-day and 1-year safety and performance of the Hydra transcatheter aortic valve (THV) (in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk. BACKGROUND: The Hydra THV is a novel repositionable self-expanding system with supra-annular bovine pericardial leaflets. METHODS: The Hydra CE study was a premarket, prospective, multicenter, single-arm study conducted across 18 study centers in Europe and Asia-Pacific countries. The primary endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee. RESULTS: A total of 157 patients (79.2 ± 7.1 years of age, 58.6% female; Society of Thoracic Surgeons score 4.7 ± 3.4%) were enrolled. Successful implantation was achieved in 94.3% cases. At 30 days, there were 11 (7.0%) deaths, including 9 (5.7%) cardiovascular deaths, of which 5 (3.2%) were device related. At 1 year, there were 23 (14.6%) deaths, including 13 (8.3%) cardiovascular deaths. At 30 days, there were significant improvement of effective orifice area (from 0.7 ± 0.2 cm2 to 1.9 ± 0.6 cm2) and mean aortic valve gradient (from 49.5 ± 18.5 mm Hg to 8.1 ± 3.7 mm Hg), which were sustained up to 1 year. Moderate or severe paravalvular leak was observed in 6.3% of patients at 30 days and 6.9% of patients at 1 year. The rate of new permanent pacemaker implantation was 11.7% at 30 days and 12.4% at 1 year. CONCLUSIONS: The Hydra CE study demonstrated that transcatheter aortic valve replacement with Hydra THV offered favorable efficacy at 1 year, providing large effective orifice area and low transvalvular gradient as well as acceptable complication rates with regard to new permanent pacemaker and paravalvular leak. (A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve; NCT02434263).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bovinos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
12.
Medicina (Kaunas) ; 57(7)2021 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-34357002

RESUMEN

Congenital long QT syndrome (LQTS) is a hereditary ion channelopathy associated with ventricular arrhythmia and sudden cardiac death starting from young age due to prolonged cardiac repolarization, which is represented by QT interval changes in electrocardiogram (ECG). Mutations in human ether-à-go-go related gene (KCNH2 (7q36.1), formerly named hERG) are responsible for Long QT syndrome type 2 (LQT2). LQT2 is the second most common type of LQTS. A resuscitated 31-year-old male with the diagnosis of LQT2 and his family are described. Sequencing analysis of their genomic DNA was performed. Amino acid alteration p.(Ser631Pro) in KCNH2 gene was found. This variant had not been previously described in literature, and it was found in three nuclear family members with different clinical course of the disease. Better understanding of genetic alterations and genotype-phenotype correlations aids in risk stratification and more effective management of these patients, especially when employing a trigger-specific approach to risk-assessment and individually tailored therapy.


Asunto(s)
Paro Cardíaco , Síndrome de QT Prolongado , Adulto , Muerte Súbita Cardíaca/etiología , Canal de Potasio ERG1/genética , Canales de Potasio Éter-A-Go-Go/genética , Paro Cardíaco/genética , Humanos , Síndrome de QT Prolongado/complicaciones , Síndrome de QT Prolongado/genética , Masculino , Mutación
13.
Acta Med Litu ; 28(1): 127-135, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34393635

RESUMEN

SUMMARY BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a heritable cardiomyopathy, characterized by fibrofatty replacement of myocytes in the right ventricular, left ventricular or both ventricles. It is caused by pathogenic variants of genes encoding desmosomal (JUP, DSP, PKP2, DSG2, DSC2) and non-desmosomal proteins, and is one of the most common causes of sudden cardiac death in young athletes. Therefore, early identification, correct prevention and treatment can prevent adverse outcomes. CASE REPORT: Our case presents a 65-years-old man with recurrent ventricular tachycardia. The ischemic cause was the first to rule out. Echocardiography revealed right ventricular structural and functional abnormalities. After suspicion of ARVC, magnetic resonance imaging was performed showing reduced right ventricular ejection fraction with local aneurysms, structural changes ir the right and left myocardium. Subsequently performed genetic testing identified a novel ARVC likely pathogenic variant in DSC2 gene and variant of uncertain significance in RYR2 gene. CONCLUSIONS: Diagnostic evaluation of ARVC is challenging and requires multidisciplinary team collaboration. Further functional tests for elucidation of the clinical significance of the two novel variants of ARVC-associated genes could be suggested.

14.
JTCVS Tech ; 10: 231-242, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34977729

RESUMEN

BACKGROUND: We report 3 cases of rescue transventricular off-pump mitral valve (MV) repair in high-risk patients with acute mitral regurgitation (MR) due to post-myocardial infarction (MI) papillary muscle rupture (PMR). METHODS: The 3 patients presented with acute inferior ST elevation myocardial infarction, cardiogenic shock, and pulmonary edema. Their preoperative peak troponin I levels were 1909 ng/L, 16,963 ng/L, and 8299 ng/L. All 3 patients underwent successful percutaneous intervention to the culprit coronary artery, and antiplatelet therapy was initiated. All patients required inotropic support and had an intra-aortic balloon pump inserted preoperatively. Transesophageal echocardiography (TEE) demonstrated severe eccentric MR due to the leaflet prolapse secondary to PMR. The patients' estimated EuroSCORE II scores were 16.03%, 16.68%, and 7.81%, and their Society of Thoracic Surgeons scores were 14.77%, 18.24%, and 9.8%, respectively. All 3 patients underwent urgent transventricular off-pump MV repair using artificial chords, with 2 or 3 three neochords implanted. The duration of operation was <2 hours, and intraoperative and postoperative drainage was minimal in all cases. MV function was assessed by qualitative and semiquantitative TEE. RESULTS: Intraoperative MR reduction to a mild level was achieved in all 3 patients. All patients had moderate MR at discharge, likely due to left ventricular remodeling. Severe MR recurred in all patients, at 5, 4, and 2 months of follow-up, respectively. All 3 patients underwent an elective MV reoperation via conventional approach. CONCLUSIONS: Off-pump transventricular MV repair may offer a safe and feasible alternative to stabilize high-risk patients with acute MR due to post-MI PMR. Although early MR recurrence is concerning, urgent transventricular MV repair may serve as a bridge to conventional surgery in such unstable patients.

15.
BMC Cardiovasc Disord ; 20(1): 275, 2020 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-32513178

RESUMEN

BACKGROUND: Adverse cardiac remodeling with a myocardial fibrosis as a key pathophysiologic component may be associated to worse survival in aortic stenosis (AS) patients. Therefore, with the application of advanced cardiac imaging we aim to investigate left ventricular myocardial fibrosis in severe AS patients undergoing aortic valve replacement (AVR) and determine its impact with post-intervention clinical outcomes. METHODS: In a prospective, observational, cohort study patients with severe AS scheduled either for surgical or transcatheter AVR will be recruited from two tertiary heart centers in Denmark and Lithuania. All patients will receive standard of care in accordance with the current guidelines and will undergo additional imaging testing before and after AVR: echocardiography with deformation analysis and cardiovascular magnetic resonance (CMR) with T1 parametric mapping. Those undergoing surgical AVR will also have a myocardial biopsy sampled at the time of a surgery for histological validation. Patients will be recruited over a 2-year period and followed up to 2 years to ascertain clinical outcomes. Follow-up CMR will be performed 12 months following AVR, and echocardiography with deformation analysis will be performed 3, 12, and 24 months following AVR. The study primary outcome is a composite of all-cause mortality and major adverse cardiovascular events. DISCUSSION: Despite continuous effort of research community there is still a lack of early predictors of left ventricular decompensation in AS, which could improve patient risk stratification and guide the optimal timing for aortic valve intervention, before irreversible left ventricular damage occurs. Advanced cardiac imaging and CMR derived markers of diffuse myocardial fibrosis could be utilized for this purpose. FIB-AS study is intended to invasively and non-invasively assess diffuse myocardial fibrosis in AS patients and investigate its prognostic significance in post-interventional outcomes. The results of the study will expand the current knowledge of cardiac remodeling in AS and will bring additional data on myocardial fibrosis and its clinical implications following AVR. ETHICS/DISSEMINATION: The study has full ethical approval and is actively recruiting patients. The results will be disseminated through scientific journals and conference presentations. TRIAL REGISTRATION: ClinicalTrials.govNCT03585933. Registered on 02 July 2018.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Imagen por Resonancia Cinemagnética , Miocardio/patología , Función Ventricular Izquierda , Remodelación Ventricular , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Biopsia , Dinamarca , Femenino , Fibrosis , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Lituania , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recuperación de la Función , Proyectos de Investigación , Factores de Tiempo , Resultado del Tratamiento
16.
JACC Clin Electrophysiol ; 6(6): 623-635, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32553211

RESUMEN

OBJECTIVES: This study was designed to evaluate lesion durability on invasive electrophysiologic remapping. BACKGROUND: The lattice-tip catheter generates a large thermal footprint during temperature-controlled irrigated radiofrequency ablation. In a first-in-human study, this catheter performed rapid point-by-point pulmonary vein isolation (PVI) and other linear atrial ablations. METHODS: In a prospective 3-center single-arm study, paroxysmal or persistent atrial fibrillation patients underwent PVI and, as needed, linear ablation at the cavotricuspid isthmus (CTI), mitral isthmus (MI), and/or left atrial roof; no other atrial substrate was ablated. Using the lattice catheter and a custom electroanatomic mapping system, temperature-controlled (Tmax 73° to 80°C; 2 to 7 s) point-by-point ablation was performed. Patients were followed for 12 months. RESULTS: A total of 65 patients (61.5% paroxysmal/38.5% persistent) underwent ablation: PVI in 65, MI in 22, left atrial roof in 24, and CTI in 48 patients. At a median of 108 days after the index procedure, protocol-mandated remapping was performed in 27 patients. The pulmonary veins (PVs) remained durably isolated in all but 1 reconnected PV-translating to durable isolation in 99.1% of PVs, or 96.3% of patients with all PVs isolated. Of 47 linear atrial lesions initially placed during the index procedure, durability was observed in 10 of 11 (90.9%) MI lines, all 11 (100%) roof lines, and all 25 (100%) CTI lines. After a median follow-up of 270 days, the 12-month Kaplan-Meier estimate for freedom from atrial arrhythmias was 94.4 ± 3.2%. CONCLUSIONS: Temperature-controlled lattice-tip point-by-point ablation showed not only highly durable PVI lesion sets, but also durable contiguity of linear atrial lesions.


Asunto(s)
Ablación por Catéter , Venas Pulmonares , Catéteres , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Temperatura
17.
JACC Clin Electrophysiol ; 6(5): 507-519, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32439034

RESUMEN

OBJECTIVES: This study sought to evaluate the safety and acute performance of the lattice tip for the treatment of atrial flutter and fibrillation (AF). BACKGROUND: A novel catheter using an expandable lattice structure with a wide thermal footprint incorporating multiple surface thermocouples/mini-electrodes has been designed for high-resolution mapping and high-current, temperature-controlled radiofrequency ablation (RFA). METHODS: Patients with typical right atrial flutter or AF were prospectively enrolled in a single-arm study at 3 centers. Patients with atrial flutter underwent cavotricuspid isthmus (CTI) ablation. Patients with paroxysmal AF underwent pulmonary vein isolation (PVI) and CTI if desired, and for patients with persistent AF, mitral isthmus and left atrial roof lines were also permitted. Mapping was performed with the lattice (Sphere-9) catheter and a novel compatible electroanatomic mapping system (Prism-1). RFA was performed in a point-by-point fashion (Tmax, 73°C to 80°C; range 2 to 7 s). Patients were followed for 3 months. RESULTS: A total of 71 patients underwent ablation: 65 PVI (38% with persistent AF) and 22 mitral isthmus, 24 roof, and 48 CTI lines. PVI was achieved in 64 of 65 (98.5%) by using the lattice alone and required a mean of 2.7 ± 0.70 RFA min. Mitral block was achieved in 100% by using 11.5 ± 10.7 applications and 1.0 ± 0.92 RFA min; only 1 patient required adjunctive epicardial coronary sinus ablation. Roof line and CTI block were achieved in 95.8% and 100% of patients, using 4.9 ± 1.9 and 5.9 ± 3.1 applications for 0.4 ± 0.16 and 0.5 ± 0.24 RFA min, respectively. At 3 months, there were no deaths, strokes, tamponade, or atrioesophageal fistula. CONCLUSIONS: This first-in-human study demonstrated clinical feasibility and safety for rapid high-current, temperature-controlled point-by-point PVI and linear ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Catéteres , Humanos , Venas Pulmonares/cirugía , Temperatura
18.
Circ Arrhythm Electrophysiol ; 13(6): e008718, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32383391

RESUMEN

BACKGROUND: The tissue selectivity of pulsed field ablation (PFA) provides safety advantages over radiofrequency ablation in treating atrial fibrillation. One-shot PFA catheters have been shown capable of performing pulmonary vein isolation, but not flexible lesion sets such as linear lesions. A novel lattice-tip ablation catheter with a compressible 9-mm nitinol tip is able to deliver either focal radiofrequency ablation or PFA lesions, each in 2 to 5 s. METHODS: In a 3-center, single-arm, first-in-human trial, the 7.5F lattice catheter was used with a custom mapping system to treat paroxysmal or persistent atrial fibrillation. Toggling between energy sources, point-by-point pulmonary vein encirclement was performed using biphasic PFA posteriorly and either temperature-controlled irrigated radiofrequency ablation or PFA anteriorly (RF/PF or PF/PF, respectively). Linear lesions were created using either PFA or radiofrequency ablation. RESULTS: The 76-patient cohort included 55 paroxysmal and 21 persistent atrial fibrillation patients undergoing either RF/PF (40 patients) or PF/PF (36 patients) ablation. The pulmonary vein isolation therapy duration time (transpiring from first to last lesion) was 22.6±8.3 min/patient, with a mean of 50.1 RF/PF lesions/patient. Linear lesions included 14 mitral (4 RF/2 RF+PF/8 PF), 34 left atrium roof (12 RF/22 PF), and 44 cavotricuspid isthmus (36 RF/8 PF) lines, with therapy duration times of 5.1±3.5, 1.8±2.3, and 2.4±2.1 min/patient, respectively. All lesion sets were acutely successful, using 4.7±3.5 minutes of fluoroscopy. There were no device-related complications, including no strokes. Postprocedure esophagogastroduodenoscopy revealed minor mucosal thermal injury in 2 of 36 RF/PF and 0 of 24 PF/PF patients. Postprocedure brain magnetic resonance imaging revealed diffusion-weighted imaging+/fluid-attenuated inversion recovery- and diffusion-weighted imaging+/fluid-attenuated inversion recovery+ asymptomatic lesions in 5 and 3 of 51 patients, respectively. CONCLUSIONS: A novel lattice-tip catheter could safely and rapidly ablate atrial fibrillation using either a combined RF/PF approach (capitalizing on the safety of PFA and the years of experience with radiofrequency energy) or an entirely PF approach. Registration: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT04141007 and NCT04194307.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Venas Pulmonares/cirugía , Irrigación Terapéutica/instrumentación , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ablación por Catéter/efectos adversos , República Checa , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Lituania , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Irrigación Terapéutica/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
19.
Eur J Cardiothorac Surg ; 58(3): 648-650, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32268363

RESUMEN

Transapical mitral valve repair with NeoChord implantation is effective and safe to replace ruptured chordae due to degenerative disease. Redo transapical neochordae implantation has never been reported in the literature. We present a case report of a 53-year-old man who underwent a reoperative neochord implantation for recurrent severe mitral regurgitation, resulting from degenerative disease progression with a new native chordal rupture. We report the midterm durability of reoperative Neochord repair.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Cuerdas Tendinosas/diagnóstico por imagen , Cuerdas Tendinosas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/cirugía , Reoperación , Resultado del Tratamiento
20.
Eur Radiol ; 30(9): 5222, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32291500

RESUMEN

The original version of this article, published on 12 August 2019, unfortunately contained a mistake. The funding note was incorrect; the correct funding note is given below.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA