Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Gan To Kagaku Ryoho ; 50(3): 333-335, 2023 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-36927902

RESUMEN

The patient was a 69-year-old man. He visited our hospital with a complaint of right back pain. An abdominal CT scan confirmed a hypovascular mass 35 mm in diameter in the pancreatic head. He was diagnosed with pancreatic head cancer (cT3, cN0, cM0, cStage ⅡA, borderline resectable-A). Gemcitabine plus S-1(GS)-based chemoradiation therapy(CRT) was performed, followed by 6 courses of GS therapy. Tumor markers were almost normalized, and subtotal stomach-preserving pancreaticoduodenectomy was performed. Histopathological examination of the resected specimen revealed highly atrophic pancreatic tissue with fibrosis and no evidence of residual cancer cells (pathological complete response). The patient remains disease-free 36 months after surgery. There are few reports of pancreatic cancer with pCR after GS-based chemoradiation therapy and subsequent GS therapy. We therefore report this case together with a review of the literature.


Asunto(s)
Gemcitabina , Neoplasias Pancreáticas , Masculino , Humanos , Anciano , Desoxicitidina/uso terapéutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Terapia Combinada , Terapia Neoadyuvante , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas
2.
Cardiovasc Intervent Radiol ; 40(4): 609-615, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28194507

RESUMEN

PURPOSE: To demonstrate the use of "Smart Puncture," a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application. MATERIALS AND METHODS: A puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone's liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured. RESULTS: The mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased. CONCLUSION: This application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.


Asunto(s)
Absceso/diagnóstico por imagen , Absceso/terapia , Drenaje/métodos , Radiografía Intervencional/métodos , Teléfono Inteligente , Tomografía Computarizada por Rayos X/métodos , Adulto , Drenaje/instrumentación , Femenino , Humanos , Movimiento (Física) , Agujas , Punciones/métodos
3.
Jpn J Radiol ; 31(9): 633-6, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23729367

RESUMEN

We present a case of multifocal micronodular pneumocyte hyperplasia (MMPH), lymphangiomyomatosis (LAM) and angiomyolipoma (AML) in a 33-year-old woman with tuberous sclerosis complex referred to us during her first pregnancy. Computed tomography of the chest showed diffuse micronodules and cysts in both lungs. Compared to those before pregnancy, the number of micronodules increased evidently. We hypothesized the micronodules in both lungs were either LAM, MMPH, or a combination of the two. Bilateral renal AML also intensified. About one month after childbirth, LAM and renal AML decreased without treatment. Therefore, we observed that LAM and AML were affected by the pregnancy. To the best of our knowledge, this is the first case report regarding the reversible alteration of LAM without treatment.


Asunto(s)
Angiomiolipoma/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Linfangioleiomiomatosis/diagnóstico por imagen , Regresión Neoplásica Espontánea , Complicaciones Neoplásicas del Embarazo/diagnóstico por imagen , Adulto , Angiomiolipoma/complicaciones , Diagnóstico Diferencial , Femenino , Humanos , Hiperplasia/complicaciones , Hiperplasia/diagnóstico por imagen , Riñón/diagnóstico por imagen , Neoplasias Renales/complicaciones , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/complicaciones , Linfangioleiomiomatosis/complicaciones , Parto , Periodo Posparto , Embarazo , Tomografía Computarizada por Rayos X/métodos , Esclerosis Tuberosa/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA