Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 5 de 5
1.
Radiol Case Rep ; 18(12): 4389-4392, 2023 Dec.
Article En | MEDLINE | ID: mdl-37929049

Intercostal lipomas are rare benign tumors that predominantly occur in the subcutaneous tissue. However, intramuscular intercostal lipomas are exceedingly uncommon and pose diagnostic challenges due to their atypical presentation. Here, we present a case report of an intramuscular intercostal lipoma located in the left axillary tail, along with a comprehensive discussion of its clinical features, diagnostic evaluation, and management options.

2.
Cureus ; 15(5): e39585, 2023 May.
Article En | MEDLINE | ID: mdl-37250604

Granulomatous mastitis (GM) is a rare disease that occurs in young premenopausal women, is mostly idiopathic, and is less likely to be caused by infection and trauma. It is also strongly associated with pregnancy, lactation, and hyperprolactinemia. GM superimposed by infection with abscess formation caused by Salmonella is extremely rare. Upon reviewing the literature, our case is considered to be the first reported case globally. Most breast abscesses are caused by Staphylococcus aureus.

3.
Cureus ; 12(11): e11480, 2020 Nov 14.
Article En | MEDLINE | ID: mdl-33329976

Background Chorionic bump is a rare condition defined as a bulge or protrusion from the choriodecidual surface into the gestational sac. The limited literature on this infrequent entity suggests that the pregnancies with multiple chorionic bumps mostly result in fetal demise. Aims To review the available literature and the patients from our institute having sonographic findings of chorionic bump and making the sonographers and radiologists aware of this known cause of first-trimester pregnancy loss. Study design A retrospective review of the cases diagnosed at our institute during the last four years. Methods and materials Single-center institutional data for four years (January 2016-December 2019) was accessed using ICD codes. IRB approval was waived owing to the anonymized use of patient data. Results Six female patients diagnosed with chorionic bump were included, with a mean age of 29.83±12 years. The average gestational age at the time of diagnosis was 8.16±3 weeks. The most common sonographic findings were a protrusion from the chorionic wall into the gestational sac cavity, having a central hypoechoic region with peripheral hyperechoic rim (isoechoic to the chorion) and having no vascularity (n=5), and the less common finding was a hyperechoic protrusion with no vascularity (n=1). n=5 had a single lesion, and n=1 had two lesions. The average diameter of the lesion in the largest dimension was 18±11 mm. n=3 pregnancies resulted in a first-trimester miscarriage, and n=3 pregnancies delivered healthy babies at term.  Conclusions A chorionic bump significantly increases the risk of a first-trimester miscarriage.

4.
Eur J Radiol Open ; 7: 100282, 2020.
Article En | MEDLINE | ID: mdl-33145375

OBJECTIVES: The objectives of this study were to: 1) evaluate patient radiation exposure in CT and 2) establish CT Diagnostic Reference Levels (DRL)s based on clinical indication (CI) in Qatar. MATERIALS AND METHODS: Patient data for 13 CIs were collected using specially designed collection forms from the dose management software (DMS) of Hamad Medical Corporation (HMC), the main Qatar healthcare provider. The methodology described in the International Commission on Radiological Protection (ICRP) Report 135 was followed to establish national clinical DRLs in terms of Volumetric Computed Tomography Dose Index (CTDIvol) and total Dose Length Product (DLPt). Effective dose (Ef) was estimated by DMS using DLPt and appropriate conversion factors and was analyzed for comparison purposes. RESULTS: Data were retrospectively collected for 896 adult patients undergoing CT examinations in 4 hospitals and 7 CT scanners. CT for Diffuse infiltrative lung disease imparted the lowest radiation in terms of CTDIvol (5 mGy), DLPt (181 mGy.cm) and Ef (3.6 mSv). Total body CT for severe trauma imparted the highest DLPt (3137 mGy.cm) and Ef (38.6 mSv) of all CIs with a CTDIvol of 15 mGy. Rounded Third quartile CTDIvol and DLPt values were defined as the Qatar CT clinical DRLs. Comparison was limited due to sparse international literature. When this was possible data were lower or comparable with other studies. CONCLUSIONS: This is the first study reporting national clinical DRLs in Asia and second one internationally after UK. For accurate comparison between studies, systemized CI nomenclature must be followed by researchers.

5.
Radiat Prot Dosimetry ; 189(3): 354-361, 2020 Jul 17.
Article En | MEDLINE | ID: mdl-32342104

In the absence of information on radiation doses in mammography in the Gulf countries, this study was designed to assess patient dose in terms of entrance surface air kerma and average glandular dose (AGD) in three mammography units in Qatar that covers 21% of all mammography systems in the country. The study of 150 patients involving 600 projections indicated that the average value of AGD in patients was 2.2 mGy for cranio-caudal and 2.5 mGy for mediolateral-oblique views, respectively. Dose assessment was also performed for polymethyl methacrylate phantoms of thicknesses, ranging from 20 to 80 mm. Comparing the patient dose values with several other publications in literature for full-field digital mammography, our values are typically higher, which can be likely attributed to the larger compressed breast thickness.


Mammography , Radiographic Image Enhancement , Breast/diagnostic imaging , Humans , Phantoms, Imaging , Qatar , Radiation Dosage
...