Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Radiother Oncol ; 195: 110230, 2024 Jun.
Article En | MEDLINE | ID: mdl-38503355

BACKGROUND AND PURPOSE: Given the substantial lack of knowledge, we aimed to assess clinical/dosimetry predictors of late hematological toxicity on patients undergoing pelvic-nodes irradiation (PNI) for prostate cancer (PCa) within a prospective multi-institute study. MATERIALS AND METHODS: Clinical/dosimetry/blood test data were prospectively collected including lymphocytes count (ALC) at baseline, mid/end-PNI, 3/6 months and every 6 months up to 5-year after PNI. DVHs of the Body, ileum (BMILEUM), lumbosacral spine (BMLS), lower pelvis (BMPELVIS), and whole pelvis (BMTOT) were extracted. Current analysis focused on 2-year CTCAEv4.03 Grade ≥ 2 (G2+) lymphopenia (ALC < 800/µL). DVH parameters that better discriminate patients with/without toxicity were first identified. After data pre-processing to limit overfitting, a multi-variable logistic regression model combining DVH and clinical information was identified and internally validated by bootstrap. RESULTS: Complete data of 499 patients were available: 46 patients (9.2 %) experienced late G2+ lymphopenia. DVH parameters of BMLS/BMPELVIS/BMTOT and Body were associated to increased G2+ lymphopenia. The variables retained in the resulting model were ALC at baseline [HR = 0.997, 95 %CI 0.996-0.998, p < 0.0001], smoke (yes/no) [HR = 2.9, 95 %CI 1.25-6.76, p = 0.013] and BMLS-V ≥ 24 Gy (cc) [HR = 1.006, 95 %CI 1.002-1.011, p = 0.003]. When acute G3+ lymphopenia (yes/no) was considered, it was retained in the model [HR = 4.517, 95 %CI 1.954-10.441, p = 0.0004]. Performances of the models were relatively high (AUC = 0.87/0.88) and confirmed by validation. CONCLUSIONS: Two-year lymphopenia after PNI for PCa is largely modulated by baseline ALC, with an independent role of acute G3+ lymphopenia. BMLS-V24 was the best dosimetry predictor: constraints for BMTOT (V10Gy < 1520 cc, V20Gy < 1250 cc, V30Gy < 850 cc), and BMLS (V24y < 307 cc) were suggested to potentially reduce the risk.


Bone Marrow , Lymphopenia , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/pathology , Lymphopenia/etiology , Prospective Studies , Aged , Bone Marrow/radiation effects , Middle Aged , Pelvis/radiation effects , Radiotherapy Dosage , Lymphatic Irradiation/adverse effects , Lymphatic Irradiation/methods , Aged, 80 and over
2.
Phys Imaging Radiat Oncol ; 28: 100488, 2023 Oct.
Article En | MEDLINE | ID: mdl-37694264

Background and Purpose: The association between dose to selected bladder and rectum symptom-related sub-regions (SRS) and late toxicity after prostate cancer radiotherapy has been evidenced by voxel-wise analyses. The aim of the current study was to explore the feasibility of combining knowledge-based (KB) and multi-criteria optimization (MCO) to spare SRSs without compromising planning target volume (PTV) dose delivery, including pelvic-node irradiation. Materials and Methods: Forty-five previously treated patients (74.2 Gy/28fr) were selected and SRSs (in the bladder, associated with late dysuria/hematuria/retention; in the rectum, associated with bleeding) were generated using deformable registration. A KB model was used to obtain clinically suitable plans (KB-plan). KB-plans were further optimized using MCO, aiming to reduce dose to the SRSs while safeguarding target dose coverage, homogeneity and avoiding worsening dose volume histograms of the whole bladder, rectum and other organs at risk. The resulting MCO-generated plans were examined to identify the best-compromise plan (KB + MCO-plan). Results: The mean SRS dose decreased in almost all patients for each SRS. D1% also decreased in the large majority, less frequently for dysuria/bleeding SRS. Mean differences were statistically significant (p < 0.05) and ranged between 1.3 and 2.2 Gy with maximum reduction of mean dose up to 3-5 Gy for the four SRSs. The better sparing of SRSs was obtained without compromising PTVs coverage. Conclusions: Selectively sparing SRSs without compromising PTV coverage is feasible and has the potential to reduce toxicities in prostate cancer radiotherapy. Further investigation to better quantify the expected risk reduction of late toxicities is warranted.

3.
Phys Med ; 100: 142-152, 2022 Aug.
Article En | MEDLINE | ID: mdl-35839667

PURPOSE: To develop and validate an automated segmentation tool for COVID-19 lung CTs. To combine it with densitometry information in identifying Aerated, Intermediate and Consolidated Volumes in admission (CT1) and follow up CT (CT3). MATERIALS AND METHODS: An Atlas was trained on manually segmented CT1 of 250 patients and validated on 10 CT1 of the training group, 10 new CT1 and 10 CT3, by comparing DICE index between automatic (AUTO), automatic-corrected (AUTOMAN) and manual (MAN) contours. A previously developed automatic method was applied on HU lung density histograms to quantify Aerated, Intermediate and Consolidated Volumes. Volumes of subregions in validation CT1 and CT3 were quantified for each method. RESULTS: In validation CT1/CT3, manual correction of automatic contours was not necessary in 40% of cases. Mean DICE values for both lungs were 0.94 for AUTOVsMAN and 0.96 for AUTOMANVsMAN. Differences between Aerated and Intermediate Volumes quantified with AUTOVsMAN contours were always < 6%. Consolidated Volumes showed larger differences (mean: -95 ± 72 cc). If considering AUTOMANVsMAN volumes, differences got further smaller for Aerated and Intermediate, and were drastically reduced for consolidated Volumes (mean: -36 ± 25 cc). The average time for manual correction of automatic lungs contours on CT1 was 5 ± 2 min. CONCLUSIONS: An Atlas for automatic segmentation of lungs in COVID-19 patients was developed and validated. Combined with a previously developed method for lung densitometry characterization, it provides a fast, operator-independent way to extract relevant quantitative parameters with minimal manual intervention.


COVID-19 , COVID-19/diagnostic imaging , Densitometry , Humans , Longitudinal Studies , Lung/diagnostic imaging
...