Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Photodiagnosis Photodyn Ther ; 44: 103879, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37923284

RESUMEN

AIMS: To evaluate the impact of conditioning protocols, aluminum trioxide (Al2O3), Er:YAG laser (EYL), and Rosebengal (RB), on the surface roughness (Ra) and shear bond strength (SBS) of polyetheretherketone (PEEK) attached to composite restorations. METHOD: Eighty PEEK discs in total were produced and then divided into four groups (n = 20). Group1:Sulfuric acid (SA), Group 2: PDT (RB), Group 3: Al2O3, Group 4 EYL, respectively. The Ra of PEEK discs was evaluated using the surface profilometer. After being luted, the discs were attached to composite resin discs. After that, samples were put to SBS testing on a Universal testing apparatus. A stereo microscope was also used to evaluate the type of breakdown. The data were analyzed using Tukey's test and one-way analysis of variance. RESULTS: The SA treated group exhibited the highest Ra. Nevertheless, the RB specimens activated by PDT treatment had the lowest mean Ra score. The group that received the treatment of SA exhibited the highest average score of SBS. In contrast, specimens treated with PDT and activated by RB exhibited the lowest levels of bond fidelity. Cohesive failure emerges as the prevailing kind of fracture within the various groups subjected to testing. CONCLUSION: The utilization of Al2O3, RB activated by PDT, and EYL shows promise as a viable substitute for Sulfuric acid in enhancing the bond integrity of composite cement and surface roughness in PEEK materials.


Asunto(s)
Benzofenonas , Láseres de Estado Sólido , Fotoquimioterapia , Polímeros , Ácidos Sulfúricos , Resinas Compuestas/química , Aluminio , Ensayo de Materiales , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Polietilenglicoles , Cetonas
2.
Photodiagnosis Photodyn Ther ; 43: 103689, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37414110

RESUMEN

AIM: The chief aim of the study was to determine/equate the surface roughness (SRa) and shear bond strength (BS) of pretreated PEEK discs with contemporary air abrasion techniques, photodynamic (PD) therapy by curcumin photosensitizer (PS) and conventional diamond grit straight fissure bur adhered to the composite resin discs. MATERIAL AND METHOD: Two hundred discs of PEEK were prepared of 6 mm × 2 mm × 10 mm dimension. The discs were randomly divided into five groups (n = 40) for treatment, Group I: treatment with deionized distilled water (control group); Group II: PD therapy using curcumin PS; Group III: discs treated and abraded with air-borne particles (ABP) silica (30 µm particle size) modified alumina (Al); Group IV: ABP of alumina (110 µm particle size); and Group V: The PEEK were finished with 600-µm grit size straight diamond cutting bur installed in high speed hand-piece. The surface profilometer was used to evaluate the values of surface roughness (SRa) of pretreated PEEK discs. The discs were luted and bonded to discs of composite resin. The bonded PEEK samples were placed in Universal testing machine to evaluate shear BS. The type of BS failure for PEEK discs pre-treated with five regimes respectively was evaluated under stereo-microscope. The data was statistically analyzed using one-way ANOVA and the comparisons between mean values of shear BS were evaluated by Tukey's test (ρ≤0.05). RESULTS: The PEEK samples pre-treated with diamond cutting straight fissure burs displayed statistically significant highest value of SRa values (3.258± 0.785 µm). Similarly, the shear BS was observed to be higher for the PEEK discs pre-treated with straight fissure bur (22.37±0.78 MPa). A comparable difference but not statistically significant difference was observed between PEEK discs pre-treated by curcumin PS and ABP-silica modified alumina (ρ ≥ 0.05). CONCLUSION: PEEK discs pre-treated with diamond grit straight fissure bur displayed highest values of SRa and shear BS. It was trailed by ABP-Al pre-treated discs; whereas the SRa and shear BS values for the discs pre-treated with ABP-silica modified Al and curcumin PS did not show competitive difference.


Asunto(s)
Curcumina , Fotoquimioterapia , Resinas Compuestas/química , Propiedades de Superficie , Ensayo de Materiales , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Diamante/química , Óxido de Aluminio/química , Dióxido de Silicio/química
3.
Photodiagnosis Photodyn Ther ; 43: 103605, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37187269

RESUMEN

AIM: Evaluation of the push-out bond strength (PBS) of zirconia post-bonded to radicular dentin after using different final irrigants (MTAD, Malachite green (MG), Ti-sapphire laser and Salvadora persica (S.persica). MATERIAL AND METHOD: Forty human permanent single-rooted were decoronated above the cement-enamel junction. An experienced endodontist performed all the root canal instrumentation using ProTaper universal rotary files. Canals were irrigated using 5.25% NaOCl solution followed by EDTA as a final sterilant. Obturation with gutta-percha using AH Plus sealer was performed. Post-space preparation was completed using Gates Glidden and specimens were randomly assigned to four groups based on the final disinfectant received (n=10). Group 1: 5.25% NaOCl + MTAD, group 2: 5.25% NaOCl + MG, group 3: 5.25% NaOCl +Ti-sapphire laser, and group 4: 5.25% NaOCl + S. persica. The chemically polymerized resin was used to lute zirconia posts. PBS and failure mode analysis were performed using a universal testing machine and stereomicroscope at 40X magnification. Data were compared between the two groups with 95% CI using one-way analysis of variance (ANOVA) with the Tukey post hoc test. p=0.05. RESULTS: Group4(5.25% NaOCl+ S.persica) specimens demonstrated the maximum (8.94±0.14 MPa) bond strength. Conversely, the apical third of Group 2 (5.25% NaOCl+ MG) (2.87±0.15 MPa) samples revealed the minimum bond strength scores. Intergroup comparison exposed that Group 1 (1.3% NaOCl+ MTAD), Group 3 (5.25% NaOCl+Ti-sapphire laser), and Group 4 (5.25% NaOCl+ S. persica) at all three-thirds unveiled no significant difference in PBS (p<0.05). CONCLUSION: Ti-sapphire laser and Salvedora Persica possess the potential to be used as a final root canal irrigant to improve the push-out bond strength of zirconia post-to-root dentin.


Asunto(s)
Fotoquimioterapia , Materiales de Obturación del Conducto Radicular , Humanos , Resinas Epoxi , Óxido de Aluminio , Ácido Edético , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes , Titanio , Rayos Láser , Dentina , Irrigantes del Conducto Radicular , Ensayo de Materiales , Cavidad Pulpar , Preparación del Conducto Radicular
4.
Polymers (Basel) ; 15(4)2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36850239

RESUMEN

BACKGROUND: Polyetheretherketone (PEEK) has provided the option to fabricate RPDs with aesthetics unlike metal RPDs, but little attention has been paid to its suitability, especially towards the retentive forces and deformation of the clasp. This study aimed to examine the retentive forces and the fitting surface (inner surface) deformation of clasps made from PEEK and compare it with cobalt-chromium (Co-Cr) clasp. METHODS: Forty-two circumferential clasps (14 Co-Cr and 28 PEEK) were fabricated and divided into two groups with clasp undercuts (0.25 mm and 0.5 mm) with thicknesses of 1 mm and 1.5 mm. Each was examined for retentive forces after cycle test on its abutment for 360 cycles. Initial and final retentive forces were recorded. The fitting surface deformation was determined using 3-Matic research analysis software. RESULTS: The results revealed that highest mean initial retentive force was of Co-Cr clasps with 0.50 mm undercut 22.26 N (±10.15 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 3.35 N (±0.72 N) and highest mean final retentive force was the Co-Cr clasps with 0.50 mm undercut 21.40 N (±9.66 N), and the lowest was the 1 mm PEEK clasps with 0.25 mm undercut 2.71 N (±0.47 N). PEEK clasps had a lower retentive force than Co-Cr clasps with 0.50 undercut. PEEK clasps (1.5 mm) at 0.25 mm undercut had the least deformation (35.3 µm). PEEK showed significantly less deformation (p ≤ 0.014) than Co-Cr. CONCLUSION: The deformation of PEEK clasps fitting surface was lower than Co-Cr clasps and retentive forces were close to the Co-Cr clasps, suggesting the use of PEEK as an aesthetic clasp option for RPD framework.

5.
Polymers (Basel) ; 15(3)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36772044

RESUMEN

An accurate and dimensionally stable trial denture base is required for a successful denture. The aim of this in vitro study was to assess the dimensional stability of a light-activated urethane dimethacrylate (UDMA) visible light cure (VLC) denture base with three fabrication techniques and different curing cycles. Forty-five VLC denture base samples were divided evenly into three groups. Group A used a conventional fabrication technique with a curing cycle of 5 min. Group B used a modified fabrication technique with two 4-min curing cycles. Group C used a multi-step fabrication technique with three curing cycles (4 min, plus 4 min, plus 2 min). The samples were sectioned and observed under a stereomicroscope to measure the discrepancy between the sample and the master cast. The mean dimensional discrepancy (mm) at the molar region at mid-palate, after 24 h in Group A, B and C was 0.790 mm, 0.741 mm and 0.379 mm, respectively; at the right ridge crest, it was 0.567, 0.408 and 0.185, while at the left ridge crest it was 0.475, 0.331 and 0.125, respectively. Statistical analysis showed significantly different dimensional discrepancies among the groups at all three sites; right ridge crest (F = 93.54, p < 0.001), left ridge crest (F = 105.96, p < 0.001) and mid-palate (F = 125.53, p < 0.001). Within the limitations of this laboratory study, it can be concluded that the denture base using a multi-step fabrication technique with three curing cycles provides better adaptation than the conventional technique. The significance of the study is that clinicians should consider performing denture base fabrication using a multi-step technique to enhance adaptation and hence the stability of the dentures for patients.

6.
Photodiagnosis Photodyn Ther ; 42: 103326, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36773753

RESUMEN

BACKGROUND: The present report assessed the efficacy of curcumin-mediated photodynamic therapy (CUR-mediated PDT) as an adjunct to antifungal gel treatment by evaluating the salivary interleukin-6 (IL-6) and matrix metalloproteinases-8 (MMP-8) levels together with Candida species counts in denture stomatitis (DS) patients. METHODS: In total, 50 DS subjects were randomly categorized into 2 groups: Group-1: subjects who received the antifungal gel treatment and Group-2: participants who received CUR-mediated PDT. The Sabourad Dextrose Agar and CHROMAgar were utilized for evaluating Candida species counts, while the Enzyme-Linked Immunosorbent Assay was employed to estimate the salivary levels of IL-6 and MMP-8. All clinical evaluations were performed at the baseline, 1 month, and 2 months. RESULTS: In total, group-2 subjects showed a significant decrease in Candida albicans (C. albicans) counts on both follow-ups (i.e., 1-month and 2-month) than group-1 participants. C. krusei count also reduced in group-2 subejcts than group-1 participants at the 2nd follow-up as compared to the baseline, nevertheless, a slight increase in C. krusei count was noticed in group-2 subjects at the 2nd follow-up than the 1st follow-up. The salivary IL-6 and MMP-8 levels in both groups reduced significantly at both follow-ups than the baseline. According to the stepwise logistic regression analysis, no statistically significant correlation was observed between Candida species count and other parameters such as age and gender of the patient, duration of DS, and frequency of treatment(s). CONCLUSION: CUR-mediated PDT is an efficaciousness therapeutic modality for alleviating Candida species counts on the surface of denture and the palatal mucosa, as well as improving the salivary IL-6 and MMP-8 levels in DS patients.


Asunto(s)
Fotoquimioterapia , Estomatitis Subprotética , Humanos , Antifúngicos/uso terapéutico , Estomatitis Subprotética/tratamiento farmacológico , Estomatitis Subprotética/microbiología , Interleucina-6 , Metaloproteinasa 8 de la Matriz/uso terapéutico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Candida , Candida albicans
7.
Eur J Dent ; 15(1): 77-83, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33003242

RESUMEN

OBJECTIVE: To study the effect of using different cement types under pediatric stainless-steel crown (SSC) around mandibular second primary molar using three-dimensional (3D) finite element analysis. MATERIALS AND METHODS: A 3D finite element model was built for pediatric mandibular molar by laser scanning of natural extracted tooth. Four types of cement (zinc phosphate, glass ionomer, resin-modified glass ionomer, and resin) of 200 µm layers thickness were tested under a stainless-steel crown of 130-µm thickness. Twelve case studies were reported within this research, as the applied load of 330 N was tested with three angulations: vertical, oblique at 45°, and laterally. RESULTS: Linear static stress analysis was performed. The resultant stresses and deformations' distribution patterns did not change with cement type, while the values were altered. All deformations and stresses were found within the normal range. CONCLUSIONS: Analysis results indicated that using stiffer cement material increases tooth structure stresses and reduces crown body stresses and deformations, while bone was nearly insensitive to cement type.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...