Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biomed Microdevices ; 21(1): 12, 2019 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-30725201

RESUMEN

Steady state crossflow microfiltration (CMF) is an important and often necessary means of particle separation and concentration for both industrial and biomedical processes. The factors controlling the performance of CMF have been extensively reviewed. A major factor is transmembrane pressure (TMP). Because microchannels have small height, they tend to have high pressure gradients in the feed-flow direction. In the extreme, these gradients may even reverse the pressure across the membrane (inciting backflow). It is therefore desirable to compensate for the effect of feed-flow on the TMP, aiming at constant transmembrane pressure (cTMP) at a value which maximizes filtrate flux. This is especially critical during filtration of deformable particles (e.g. erythrocytes) through low intrinsic resistance membranes. Filtration flux is generally taken to be directly proportional to TMP, with pressure drop along the channel decreasing in the flow direction. A co-current flow of filtrate in a suitably designed filtrate collecting channel is shown to allow the TMP to remain constant and permit the sieving surface to perform optimally, permitting up to twice as much filtration over that of a naïve configuration. Manipulation of the filtrate channel may be even more beneficial if it prevents backflow that might otherwise occur at the end of a sufficiently long channel. Experiments with erythrocyte suspensions, reported here, validate these concepts.


Asunto(s)
Filtración , Membranas Artificiales , Modelos Teóricos , Diseño de Equipo , Filtración/instrumentación , Filtración/métodos , Presión , Agua
2.
Biomed Microdevices ; 20(3): 55, 2018 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-29971550

RESUMEN

Crossflow microfiltration of plasma from blood through microsieves in a microchannel is potentially useful in many biomedical applications, including clinically as a wearable water removal device under development by the authors. We report experiments that correlate filtration rates, transmembrane pressures (TMP) and shear rates during filtration through a microscopically high channel bounded by a low intrinsic resistance photolithographically-produced porous semiconductor membrane. These experiments allowed observation of erythrocyte behavior at the filtering surface and showed how their unique deformability properties dominated filtration resistance. At low filtration rates (corresponding to low TMP), they rolled along the filter surface, but at higher filtration rates (corresponding to higher TMP), they anchored themselves to the filter membrane, forming a self-assembled, incomplete monolayer. The incompleteness of the layer was an essential feature of the monolayer's ability to support sustainable filtration. Maximum steady-state filtration flux was a function of wall shear rate, as predicted by conventional crossflow filtration theory, but, contrary to theories based on convective diffusion, showed weak dependence of filtration on erythrocyte concentration. Post-filtration scanning electron micrographs revealed significant capture and deformation of erythrocytes in all filter pores in the range 0.25 to 2 µm diameter. We report filtration rates through these filters and describe a largely unrecognized mechanism that allows stable filtration in the presence of substantial cell layers.


Asunto(s)
Eritrocitos/citología , Membranas Artificiales , Diseño de Equipo , Filtración/instrumentación , Humanos , Dispositivos Laboratorio en un Chip , Porosidad , Presión , Agua/química
3.
Clin Nephrol ; 80(4): 301-5, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22762780

RESUMEN

Calciphylaxis, or calcific uremic arteriopathy (CUA), is characterized by metastatic calcification in the media of small arteries and arterioles leading to cutaneous necrosis. It is most commonly seen in patients with end stage renal disease who have elevated serum calcium × phosphorus (Ca × P) product. Normalization of Ca × P product is considered paramount in the prevention and treatment of CUA. We describe a novel presentation of CUA in which a Stage-5 CKD patient developed signs and symptoms of CUA immediately after initiation of hemodialysis (HD). We postulate that an influx of calcium from the dialysate into the patient's blood, in addition to correction of her acidosis, led to abundant substrate in a favorable milieu for Ca-P complex formation at the time of her first HD session. Our case is the first reported case of HD associated iatrogenic acute CUA. To avoid this complication, we should maintain adequate hydration,use lower calcium dialysate, and avoid vitamin D analogues and calcium-containing medications when initiating HD in patients with high Ca-P product. Since sodium thiosulfate is known to prevent precipitation of Ca-P complexes, its empiric use during initial HD treatments may be effective in preventing CUA, a potentially fatal disease.


Asunto(s)
Calcifilaxia/etiología , Fallo Renal Crónico/terapia , Diálisis Renal/efectos adversos , Piel/patología , Enfermedad Aguda , Biopsia , Calcifilaxia/patología , Diagnóstico Diferencial , Femenino , Humanos , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA