Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Adv Mater Technol ; 9(8)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-39247925

RESUMEN

The rise in additive manufacturing (AM) offers myriad opportunities for 3D-printed polymeric vascular scaffolds, such as customization and on-the-spot manufacturing, in vivo biodegradation, incorporation of drugs to prevent restenosis, and visibility under X-ray. To maximize these benefits, informed scaffold design is critical. Polymeric bioresorbable vascular scaffolds (BVS) must undergo significant deformation prior to implantation in a diameter-reduction process known as crimping which enables minimally invasive surgery. Understanding the behavior of vascular scaffolds in this step provides twofold benefits: first, it ensures the BVS is able to accommodate stresses occurring during this process to prevent failure, and further, it provides information on the radial strength of the BVS, a key metric to understanding its post-implant performance in the artery. To capitalize on the fast manufacturing speed AM provides, a low time cost solution for understanding scaffold performance during this step is necessary. Through simulation of the BVS crimping process in ABAQUS using experimentally obtained bulk material properties, we have developed a qualitative analysis tool which is capable of accurately comparing relative performance trends of varying BVS designs during crimping in a fraction of the time of experimental testing, thereby assisting in the integration of informed design into the additive manufacturing process.

2.
Bioact Mater ; 41: 553-563, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39246838

RESUMEN

Chronic bladder dysfunction due to bladder disease or trauma is detrimental to affected patients as it can lead to increased risk of upper urinary tract dysfunction. Current treatment options include surgical interventions that enlarge the bladder with autologous bowel tissue to alleviate pressure on the upper urinary tract. This highly invasive procedure, termed bladder augmentation enterocystoplasty (BAE), significantly increases the risk of patient morbidity and mortality due to the incompatibility between bowel and bladder tissue. Therefore, patients would significantly benefit from an alternative treatment strategy that can regenerate healthy tissue and restore overall bladder function. Previous research has demonstrated the potential of citrate-based scaffolds co-seeded with bone marrow-derived stem/progenitor cells as an alternative graft for bladder augmentation. Recognizing that contact guidance can potentially influence tissue regeneration, we hypothesized that microtopographically patterned scaffolds would modulate cell responses and improve overall quality of the regenerated bladder tissue. We fabricated microgrooved (MG) scaffolds using the citrate-based biomaterial poly (1,8-octamethylene-citrate-co-octanol) (POCO) and co-seeded them with human bone marrow-derived mesenchymal stromal cells (MSCs) and CD34+ hematopoietic stem/progenitor cells (HSPCs). MG POCO scaffolds supported MSC and HSPC attachment, and MSC alignment within the microgrooves. All scaffolds were characterized and assessed for bladder tissue regeneration in an established nude rat bladder augmentation model. In all cases, normal physiological function was maintained post-augmentation, even without the presence of stem/progenitor cells. Urodynamic testing at 4-weeks post-augmentation for all experimental groups demonstrated that bladder capacity increased and bladder compliance was normal. Histological evaluation of the regenerated tissue revealed that cell-seeded scaffolds restored normal bladder smooth muscle content and resulted in increased revascularization and peripheral nerve regeneration. The presence of microgrooves on the cell-seeded scaffolds increased microvasculature formation by 20 % and urothelial layer thickness by 25 % in the regenerating tissue. Thus, this work demonstrates that microtopography engineering can influence bladder tissue regeneration to improve overall anatomical structure and re-establish bladder physiology.

3.
Res Sq ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39108474

RESUMEN

Composite cranial defects have individual functional and aesthetic ramifications, as well as societal burden, while posing significant challenges for reconstructive surgeons. Single-stage composite reconstruction of these deformities entail complex surgeries that bear many short- and long-term risks and complications. Current research on composite scalp-cranial defects is sparse and one-dimensional, often focusing solely on bone or skin. Thus, there is an unmet need for a simple, clinically relevant composite defect model in rodents, where there is a challenge in averting healing of the skin component via secondary intention. By utilizing a customizable (3D-printed) wound obturator, the scalp wound can be rendered non-healing for a long period (more than 6 weeks), with the cranial defect patent. The wound obturator shows minimal biotoxicity and will not cause severe endocranium-granulation adhesion. This composite defect model effectively slowed the scalp healing process and preserved the cranial defect, embodying the characteristics of a "chronic composite defect". In parallel, an autologous reconstruction model was established as the positive control. This positive control exhibited reproducible healing of the skin within 3 weeks with variable degrees of osseointegration, consistent with clinical practice. Both models provide a stable platform for subsequent research not only for composite tissue engineering and scaffold design but also for mechanistic studies of composite tissue healing.

4.
Bioact Mater ; 41: 427-439, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39188380

RESUMEN

Approaches to regenerating bone often rely on integrating biomaterials and biological signals in the form of cells or cytokines. However, from a translational point of view, these approaches are challenging due to the sourcing and quality of the biologic, unpredictable immune responses, complex regulatory paths, and high costs. We describe a simple manufacturing process and a material-centric 3D-printed composite scaffold system (CSS) that offers distinct advantages for clinical translation. The CSS comprises a 3D-printed porous polydiolcitrate-hydroxyapatite composite elastomer infused with a polydiolcitrate-graphene oxide hydrogel composite. Using a micro-continuous liquid interface production 3D printer, we fabricate a precise porous ceramic scaffold with 60 wt% hydroxyapatite resembling natural bone. The resulting scaffold integrates with a thermoresponsive hydrogel composite in situ to fit the defect, which is expected to enhance surface contact with surrounding tissue and facilitate biointegration. The antioxidative properties of citrate polymers prevent long-term inflammatory responses. The CSS stimulates osteogenesis in vitro and in vivo. Within 4 weeks in a calvarial critical-sized bone defect model, the CSS accelerated ECM deposition (8-fold) and mineralized osteoid (69-fold) compared to the untreated. Through spatial transcriptomics, we demonstrated the comprehensive biological processes of CSS for prompt osseointegration. Our material-centric approach delivers impressive osteogenic properties and streamlined manufacturing advantages, potentially expediting clinical application for bone reconstruction surgeries.

5.
ACS Appl Mater Interfaces ; 16(34): 45422-45432, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39102678

RESUMEN

Implantable polymeric biodegradable devices, such as biodegradable vascular scaffolds, cannot be fully visualized using standard X-ray-based techniques, compromising their performance due to malposition after deployment. To address this challenge, we describe a new radiopaque and photocurable liquid polymer-ceramic composite (mPDC-MoS2) consisting of methacrylated poly(1,12 dodecamethylene citrate) (mPDC) and molybdenum disulfide (MoS2) nanosheets. The composite was used as an ink with microcontinuous liquid interface production (µCLIP) to fabricate bioresorbable vascular scaffolds (BVS). Prints exhibited excellent crimping and expansion mechanics without strut failures and, importantly, with X-ray visibility in air and muscle tissue. Notably, MoS2 nanosheets displayed physical degradation over time in phosphate-buffered saline solution, suggesting the potential for producing radiopaque, fully bioresorbable devices. mPDC-MoS2 is a promising bioresorbable X-ray-visible composite material suitable for 3D printing medical devices, such as vascular scaffolds, that require noninvasive X-ray-based monitoring techniques for implantation and evaluation. This innovative biomaterial composite system holds significant promise for the development of biocompatible, fluoroscopically visible medical implants, potentially enhancing patient outcomes and reducing medical complications.


Asunto(s)
Citratos , Disulfuros , Procedimientos Endovasculares , Molibdeno , Nanoestructuras , Andamios del Tejido , Molibdeno/química , Molibdeno/metabolismo , Disulfuros/química , Disulfuros/metabolismo , Impresión Tridimensional , Citratos/química , Nanoestructuras/química , Materiales Biocompatibles/química , Materiales Biocompatibles/metabolismo , Polímeros/química
6.
Sci Adv ; 10(23): eadk3081, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38848367

RESUMEN

Clinical outcomes for total-pancreatectomy followed by intraportal islet autotransplantation (TP-IAT) to treat chronic pancreatitis (CP) are suboptimal due to pancreas inflammation, oxidative stress during islet isolation, and harsh engraftment conditions in the liver's vasculature. We describe a thermoresponsive, antioxidant macromolecule poly(polyethylene glycol citrate-co-N-isopropylacrylamide) (PPCN) to protect islet redox status and function and to enable extrahepatic omentum islet engraftment. PPCN solution transitions from a liquid to a hydrogel at body temperature. Islets entrapped in PPCN and exposed to oxidative stress remain functional and support long-term euglycemia, in contrast to islets entrapped in a plasma-thrombin biologic scaffold. In the nonhuman primate (NHP) omentum, PPCN is well-tolerated and mostly resorbed without fibrosis at 3 months after implantation. In NHPs, autologous omentum islet transplantation using PPCN restores normoglycemia with minimal exogenous insulin requirements for >100 days. This preclinical study supports TP-IAT with PPCN in patients with CP and highlights antioxidant properties as a mechanism for islet function preservation.


Asunto(s)
Trasplante de Islotes Pancreáticos , Islotes Pancreáticos , Epiplón , Estrés Oxidativo , Trasplante de Islotes Pancreáticos/métodos , Epiplón/metabolismo , Animales , Islotes Pancreáticos/metabolismo , Islotes Pancreáticos/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Ácido Cítrico/farmacología , Humanos , Antioxidantes/farmacología , Pancreatitis Crónica/metabolismo , Pancreatitis Crónica/cirugía , Pancreatitis Crónica/patología , Polietilenglicoles/química , Polietilenglicoles/farmacología , Masculino , Transición de Fase
7.
Bioact Mater ; 38: 195-206, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38756202

RESUMEN

Fully bioresorbable vascular scaffolds (BVSs) aim to overcome the limitations of metallic drug-eluting stents (DESs). However, polymer-based BVSs, such as Abbott's Absorb, the only US FDA-approved BVS, have had limited use due to increased strut thickness (157 µm for Absorb), exacerbated tissue inflammation, and increased risk of major cardiac events leading to inferior clinical performance when compared to metallic DESs. Herein we report the development of a drug-eluting BVS (DE-BVS) through the innovative use of a photopolymerizable, citrate-based biomaterial and a high-precision additive manufacturing process. BVS with a clinically relevant strut thickness of 62 µm can be produced in a high-throughput manner, i.e. one BVS per minute, and controlled release of the anti-restenosis drug everolimus can be achieved by engineering the structure of polymer coatings to fabricate drug-eluting BVS. We achieved the successful deployment of BVSs and DE-BVSs in swine coronary arteries using a custom-built balloon catheter and BVS delivery system and confirmed BVS safety and efficacy regarding maintenance of vessel patency for 28 days, observing an inflammation profile for BVS and DE-BVS that was comparable to the commercial XIENCE™ DES (Abbott Vascular).

8.
Adv Mater ; 36(32): e2402871, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38801111

RESUMEN

Citrate-based biodegradable polymers have emerged as a distinctive biomaterial platform with tremendous potential for diverse medical applications. By harnessing their versatile chemistry, these polymers exhibit a wide range of material and bioactive properties, enabling them to regulate cell metabolism and stem cell differentiation through energy metabolism, metabonegenesis, angiogenesis, and immunomodulation. Moreover, the recent US Food and Drug Administration (FDA) clearance of the biodegradable poly(octamethylene citrate) (POC)/hydroxyapatite-based orthopedic fixation devices represents a translational research milestone for biomaterial science. POC joins a short list of biodegradable synthetic polymers that have ever been authorized by the FDA for use in humans. The clinical success of POC has sparked enthusiasm and accelerated the development of next-generation citrate-based biomaterials. This review presents a comprehensive, forward-thinking discussion on the pivotal role of citrate chemistry and metabolism in various tissue regeneration and on the development of functional citrate-based metabotissugenic biomaterials for regenerative engineering applications.


Asunto(s)
Materiales Biocompatibles , Ácido Cítrico , Humanos , Ácido Cítrico/química , Materiales Biocompatibles/química , Animales , Ingeniería de Tejidos/métodos , Polímeros/química , Durapatita/química , Durapatita/metabolismo
9.
Artículo en Inglés | MEDLINE | ID: mdl-38653931

RESUMEN

PURPOSE: The absence of clinically applicable imaging techniques for continuous monitoring of transplanted cells poses a significant obstacle to the clinical translation of stem cell-based therapies for vascular regeneration. This study aims to optimize a clinically applicable, non-invasive imaging technique to longitudinally monitor vascular endothelial cells (ECs) for vascular regeneration in peripheral artery disease (PAD). METHODS: Human induced pluripotent stem cells (HiPSCs) were employed to generate ECs (HiPSC-ECs). Lentiviral vectors encoding human sodium iodide symporter (hNIS) and enhanced green fluorescent protein (eGFP) genes were introduced to HiPSCs and HiPSC-ECs at varying multiplicities of infection (MOI). Through a combination of fluorescence microscopy and flow cytometry, an optimized transduction technique for introducing hNIS-eGFP into HiPSC-ECs was established. Subsequently, single-photon emission computed tomography (SPECT) was utilized for imaging of the transduced cells in vitro and in vivo after transplantation into the gastrocnemius muscle of nude mice. RESULTS: Lentiviral transduction resulted in sustained co-expression of hNIS and eGFP in HiPSC-ECs when transduced post-endothelial differentiation. An optimal MOI of five yielded over 90% hNIS-eGFP expression efficiency without compromising cell viability. hNIS-eGFP+ HiPSC-ECs exhibited 99mTc uptake and were detectable through SPECT in vitro. Additionally, intramuscular injection of hNIS-eGFP+ HiPSC-ECs with MatrigelTM into the hindlimbs of nude mice enabled real-time SPECT/CT tracking, from which a reduction in signal exceeding 80% was observed within 7 days. CONCLUSIONS: This study establishes an optimized cell modification and imaging protocol for tracking transplanted cells. Future efforts will focus on enhancing cell survival and integration via improved delivery systems, thereby advancing the potential of cell-based therapies for PAD.

10.
Proc Natl Acad Sci U S A ; 121(14): e2400868121, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38547066

RESUMEN

Partial cystectomy procedures for urinary bladder-related dysfunction involve long recovery periods, during which urodynamic studies (UDS) intermittently assess lower urinary tract function. However, UDS are not patient-friendly, they exhibit user-to-user variability, and they amount to snapshots in time, limiting the ability to collect continuous, longitudinal data. These procedures also pose the risk of catheter-associated urinary tract infections, which can progress to ascending pyelonephritis due to prolonged lower tract manipulation in high-risk patients. Here, we introduce a fully bladder-implantable platform that allows for continuous, real-time measurements of changes in mechanical strain associated with bladder filling and emptying via wireless telemetry, including a wireless bioresorbable strain gauge validated in a benchtop partial cystectomy model. We demonstrate that this system can reproducibly measure real-time changes in a rodent model up to 30 d postimplantation with minimal foreign body response. Studies in a nonhuman primate partial cystectomy model demonstrate concordance of pressure measurements up to 8 wk compared with traditional UDS. These results suggest that our system can be used as a suitable alternative to UDS for long-term postoperative bladder recovery monitoring.


Asunto(s)
Vejiga Urinaria , Infecciones Urinarias , Animales , Humanos , Vejiga Urinaria/cirugía , Urodinámica/fisiología , Prótesis e Implantes , Cistectomía
11.
Adv Sci (Weinh) ; 11(27): e2305562, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38350724

RESUMEN

Conductive polymers (CPs) are widely studied for their ability to influence a myriad of tissue systems. While their mixed ionic/electronic conductivity is commonly considered the primary driver of these benefits, the mechanisms by which CPs influence cell fate remain unclear. In this study, CP-biomaterial interactions are investigated using collagen, due to its widespread prevalence throughout the body and in tissue engineering constructs. Collagen is functionalized with both electrostatically and covalently bound derivatives of the CP poly(3,4-ethylenedioxythiophene) (PEDOT) doped via backbone-tethered sulfonate groups, which enable high solubility and loading to the collagen biomatrix. Intrinsically doped scaffolds are compared to those incorporated with a commercially available PEDOT formulation, which is complexed with polyanionic polystyrene sulfonate (PSS). Low loadings of intrinsically doped PEDOT do not increase substrate conductivity compared to collagen alone, enabling separate investigation into CP loading and conductivity. Interestingly, higher PEDOT loading bolsters human mesenchymal stromal (hMSC) cell gene expression of Oct-4 and NANOG, which are key transcription factors regulating cell stemness. Conductive collagen composites with commercial PEDOT:PSS do not significantly affect the expression of these transcription factors in hMSCs. Furthermore, it is demonstrated that PEDOT regulates cellular fate independently from physical changes to the material but directly to the loading of the polymer.


Asunto(s)
Compuestos Bicíclicos Heterocíclicos con Puentes , Colágeno , Polímeros , Compuestos Bicíclicos Heterocíclicos con Puentes/farmacología , Compuestos Bicíclicos Heterocíclicos con Puentes/química , Polímeros/química , Colágeno/metabolismo , Colágeno/química , Humanos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Poliestirenos/química , Células Madre Mesenquimatosas/efectos de los fármacos , Células Madre Mesenquimatosas/metabolismo , Conductividad Eléctrica
12.
bioRxiv ; 2024 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-38405945

RESUMEN

Chronic bladder dysfunction due to bladder disease or trauma is detrimental to affected patients as it can lead to increased risk of upper urinary tract dysfunction. Current treatment options include surgical intervention that enlarge the bladder with autologous bowel tissue to alleviate pressure on the upper urinary tract. This highly invasive procedure, termed bladder augmentation enterocystoplasty (BAE), significantly increases risk of patient morbidity and mortality due to the incompatibility between the bowel and bladder tissue. Therefore, patients would significantly benefit from an alternative treatment strategy that can regenerate healthy tissue and restore overall bladder function. Previous research has demonstrated the potential of citrate-based scaffolds co-seeded with bone marrow-derived stem/progenitor cells as an alternative graft for bladder augmentation. Recognizing that contact guidance is known to influence tissue regeneration, we hypothesized that patterned scaffolds would modulate cell responses and improve overall quality of the regenerated bladder tissue. We fabricated microgrooved (MG) scaffolds using citrate-based biomaterial poly(1,8-octamethylene-citrate-co-octanol) (POCO) and co-seeded them with human bone marrow derived mesenchymal stem cells (MSCs) and CD34+ hematopoietic stem/progenitor cells (HSPCs). Microgrooved POCO scaffolds supported MSC and HSPC attachment, and MSC alignment within the microgrooves. All scaffolds were characterized and assessed for bladder tissue regeneration in an established nude rat bladder augmentation model. In all cases, normal physiological function was maintained post-augmentation, even without the presence of stem/progenitor cells. Urodynamic testing at 4-weeks post-augmentation for all experimental groups demonstrated that capacity increased and compliance was normal. Histological evaluation of the regenerated tissue revealed that cell-seeded scaffolds restored normal bladder smooth muscle content and resulted in increased revascularization and peripheral nerve regeneration. The presence of microgrooves on the cell-seeded scaffolds increased microvasculature formation by 20% and urothelium layer thickness by 25% in the regenerating tissue. Thus, this work demonstrates that micropatterning affects bladder regeneration to improve overall anatomical structure and re-establish bladder physiology.

13.
Res Sq ; 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38352487

RESUMEN

Tissue engineering heavily relies on cell-seeded scaffolds to support the complex biological and mechanical requirements of a target organ. However, in addition to safety and efficacy, translation of tissue engineering technology will depend on manufacturability, affordability, and ease of adoption. Therefore, there is a need to develop scalable biomaterial scaffolds with sufficient bioactivity to eliminate the need for exogenous cell seeding. Herein, we describe synthesis, characterization, and implementation of an electroactive biodegradable elastomer for urinary bladder tissue engineering. To create an electrically conductive and mechanically robust scaffold to support bladder tissue regeneration, we developed a phase-compatible functionalization method wherein the hydrophobic conductive polymer poly(3,4-ethylenedioxythiophene) (PEDOT) was polymerized in situ within a similarly hydrophobic citrate-based elastomer poly(octamethylene-citrate-co-octanol) (POCO) film. We demonstrate the efficacy of this film as a scaffold for bladder augmentation in athymic rats, comparing PEDOT-POCO scaffolds to mesenchymal stromal cell-seeded POCO scaffolds. PEDOT-POCO recovered bladder function and anatomical structure comparably to the cell-seeded POCO scaffolds and significantly better than non-cell seeded POCO scaffolds. This manuscript reports: (1) a new phase-compatible functionalization method that confers electroactivity to a biodegradable elastic scaffold, and (2) the successful restoration of the anatomy and function of an organ using a cell-free electroactive scaffold.

14.
PNAS Nexus ; 3(2): pgae038, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38344009

RESUMEN

To date, there are no efficacious translational solutions for end-stage urinary bladder dysfunction. Current surgical strategies, including urinary diversion and bladder augmentation enterocystoplasty (BAE), utilize autologous intestinal segments (e.g. ileum) to increase bladder capacity to protect renal function. Considered the standard of care, BAE is fraught with numerous short- and long-term clinical complications. Previous clinical trials employing tissue engineering approaches for bladder tissue regeneration have also been unable to translate bench-top findings into clinical practice. Major obstacles still persist that need to be overcome in order to advance tissue-engineered products into the clinical arena. These include scaffold/bladder incongruencies, the acquisition and utility of appropriate cells for anatomic and physiologic tissue recapitulation, and the choice of an appropriate animal model for testing. In this study, we demonstrate that the elastomeric, bladder biomechanocompatible poly(1,8-octamethylene-citrate-co-octanol) (PRS; synthetic) scaffold coseeded with autologous bone marrow-derived mesenchymal stem cells and CD34+ hematopoietic stem/progenitor cells support robust long-term, functional bladder tissue regeneration within the context of a clinically relevant baboon bladder augmentation model simulating bladder trauma. Partially cystectomized baboons were independently augmented with either autologous ileum or stem-cell-seeded small-intestinal submucosa (SIS; a commercially available biological scaffold) or PRS grafts. Stem-cell synergism promoted functional trilayer bladder tissue regeneration, including whole-graft neurovascularization, in both cell-seeded grafts. However, PRS-augmented animals demonstrated fewer clinical complications and more advantageous tissue characterization metrics compared to ileum and SIS-augmented animals. Two-year study data demonstrate that PRS/stem-cell-seeded grafts drive bladder tissue regeneration and are a suitable alternative to BAE.

15.
Adv Healthc Mater ; 13(5): e2302797, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37983897

RESUMEN

Chronic wounds represent a major health risk for diabetic patients. Regeneration of such wounds requires regular medical treatments over periods that can extend for several months or more. Schemes for monitoring the healing process can provide important feedback to the patient and caregiver. Although qualitative indicators such as malodor or fever can provide some indirect information, quantitative measurements of the wound bed have the potential to yield important insights. The work presented here introduces materials and engineering designs for a wireless system that captures spatio-temporal temperature and thermal transport information across the wound continuously throughout the healing process. Systematic experimental and computational studies establish the materials aspects and basic capabilities of this technology. In vivo studies reveal that both the temperature and the changes in this quantity offer information on wound status, with indications of initial exothermic reactions and mechanisms of scar tissue formation. Bioresorbable materials serve as the foundations for versions of this device that create possibilities for monitoring on and within the wound site, in a way that bypasses the risks of physical removal.


Asunto(s)
Cicatriz , Cicatrización de Heridas , Humanos , Temperatura , Diseño de Equipo
16.
Adv Mater ; 36(6): e2306326, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38043945

RESUMEN

Regenerative medicine aims to restore tissue and organ function without the use of prosthetics and permanent implants. However, achieving this goal has been elusive, and the field remains mostly an academic discipline with few products widely used in clinical practice. From a materials science perspective, barriers include the lack of proregenerative biomaterials, a complex regulatory process to demonstrate safety and efficacy, and user adoption challenges. Although biomaterials, particularly biodegradable polymers, can play a major role in regenerative medicine, their suboptimal mechanical and degradation properties often limit their use, and they do not support inherent biological processes that facilitate tissue regeneration. As of 2020, nine synthetic biodegradable polymers used in medical devices are cleared or approved for use in the United States of America. Despite the limitations in the design, production, and marketing of these devices, this small number of biodegradable polymers has dominated the resorbable medical device market for the past 50 years. This perspective will review the history and applications of biodegradable polymers used in medical devices, highlight the need and requirements for regenerative biomaterials, and discuss the path behind the recent successful introduction of citrate-based biomaterials for manufacturing innovative medical products aimed at improving the outcome of musculoskeletal surgeries.


Asunto(s)
Materiales Biocompatibles , Ingeniería de Tejidos , Materiales Biocompatibles/farmacología , Ácido Cítrico , Medicina Regenerativa , Polímeros , Citratos
17.
bioRxiv ; 2023 Oct 30.
Artículo en Inglés | MEDLINE | ID: mdl-37961598

RESUMEN

The rise in additive manufacturing (AM) offers myriad opportunities for 3D-printed polymeric vascular scaffolds, such as customization and on-the-spot manufacturing, in vivo biodegradation, incorporation of drugs to prevent restenosis, and visibility under X-ray. To maximize these benefits, informed scaffold design is critical. Polymeric bioresorbable vascular scaffolds (BVS) must undergo significant deformation prior to implantation in a diameter-reduction process known as crimping which enables minimally invasive surgery. Understanding the behavior of vascular scaffolds in this step provides twofold benefits: first, it ensures the BVS is able to accommodate stresses occurring during this process to prevent failure, and further, it provides information on the radial strength of the BVS, a key metric to understanding its post-implant performance in the artery. To capitalize on the fast manufacturing speed AM provides, a low time cost solution for understanding scaffold performance during this step is necessary. Through simulation of the BVS crimping process in ABAQUS using experimentally obtained bulk material properties, we have developed a qualitative analysis tool which is capable of accurately comparing relative performance trends of varying BVS designs during crimping in a fraction of the time of experimental testing, thereby assisting in the integration of informed design into the additive manufacturing process.

18.
bioRxiv ; 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-37961681

RESUMEN

Implantable polymeric biodegradable devices, such as biodegradable vascular stents or scaffolds, cannot be fully visualized using standard X-ray-based techniques, compromising their performance due to malposition after deployment. To address this challenge, we describe composites of methacrylated poly(1,12 dodecamethylene citrate) (mPDC) and MoS2 nanosheets to fabricate novel X-ray visible radiopaque and photocurable liquid polymer-ceramic composite (mPDC-MoS2). The composite was used as an ink with micro continuous liquid interface production (µCLIP) to fabricate bioresorbable vascular scaffolds (BVS). Prints exhibited excellent crimping and expansion mechanics without strut failures and, importantly, required X-ray visibility in air and muscle tissue. Notably, MoS2 nanosheets displayed physical degradation over time in a PBS environment, indicating the potential for producing bioresorbable devices. mPDC-MoS2 is a promising bioresorbable X-ray-visible composite material suitable for 3D printing medical devices, particularly vascular scaffolds or stents, that require non-invasive X-ray-based monitoring techniques for implantation and evaluation. This innovative composite system holds significant promise for the development of biocompatible and highly visible medical implants, potentially enhancing patient outcomes and reducing medical complications.

19.
Bioeng Transl Med ; 8(6): e10592, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38023728

RESUMEN

Diabetes is a known risk factor for various cardiovascular complications, mediated by endothelial dysfunction. Despite the high prevalence of this metabolic disorder, there is a lack of in vitro models that recapitulate the complexity of genetic and environmental factors associated with diabetic endothelial dysfunction. Here, we utilized human induced pluripotent stem cell (iPSC)-derived endothelial cells (ECs) to develop in vitro models of diabetic endothelial dysfunction. We found that the diabetic phenotype was recapitulated in diabetic patient-derived iPSC-ECs, even in the absence of a diabetogenic environment. Subsequent exposure to culture conditions that mimic the diabetic clinical chemistry induced a diabetic phenotype in healthy iPSC-ECs but did not affect the already dysfunctional diabetic iPSC-ECs. RNA-seq analysis revealed extensive transcriptome-wide differences between cells derived from healthy individuals and diabetic patients. The in vitro disease models were used as a screening platform which identified angiotensin receptor blockers (ARBs) that improved endothelial function in vitro for each patient. In summary, we present in vitro models of diabetic endothelial dysfunction using iPSC technology, taking into account the complexity of genetic and environmental factors in the metabolic disorder. Our study provides novel insights into the pathophysiology of diabetic endothelial dysfunction and highlights the potential of iPSC-based models for drug discovery and personalized medicine.

20.
Artículo en Inglés | MEDLINE | ID: mdl-37861912

RESUMEN

Peripheral artery disease (PAD) is a prevalent cardiovascular disease with risks of limb loss. Our objective is to establish an autologous cell source for vascular regeneration to achieve limb salvage in PAD. Six PAD patients (age 50-80) were enrolled with their peripheral blood collected to derive vascular endothelial cells (ECs) with two different approaches: (1) endothelial progenitor cell (EPC) approach and (2) induced pluripotent stem cell (iPSC) approach. The iPSC approach successfully generated patient-specific ECs for all PAD patients, while the EPC approach did not yield any colony-forming ECs in any of the patients. The patient-derived iPSC-ECs expressed endothelial markers and exhibited endothelial functions. However, elevated inflammatory status with VCAM-1 expression was observed in the patient-derived cells. Pharmacological treatment with resveratrol resulted in patient-specific responses in cell viability and VCAM-1 expression. Our study demonstrates the potential of iPSC-ECs for autologous regenerative therapy in PAD, offering promise for personalized treatments for ischemic PAD. Our study establishes autologous endothelial cells from induced pluripotent stem cells as a cellular resource for regenerative treatments in peripheral artery disease.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA