Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Behav Med ; 2023 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-37759043

RESUMEN

BACKGROUND: Because of the health issues associated with high stress levels, it is important to find new strategies to regulate stress response. Previous research has examined the separate effects of fitness level and stress reappraisal on the stress response, but the combination of both factors is unknown. The goal of the study was to examine the combined effects of fitness and stress appraisal on stress responses and cognitive performance following a stressful event. METHOD: On 2 separate days, 24 highly and poorly fit young men (Mage = 22.33, SD = 3.33) were exposed to a validated stress test and were induced to view their stress as facilitative or debilitative. Objective and subjective stress responses along with cognitive performance were evaluated before and immediately after the stress test. RESULTS: Participants in the high-fit/negative appraisal condition reported lower anxiety scores than participants in the low-fit/negative appraisal condition (d = 1.04). Participants had higher levels of cortisol after the stress test (d = 0.31), but no difference in heart rate, cortisol, or cognitive performance emerged among the conditions. CONCLUSION: Fitness level might have a larger impact on stress response than stress appraisal, and stress reappraisal manipulations require more than just reading a note and a self-talk statement.

2.
Osteoporos Int ; 34(6): 1093-1099, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37000208

RESUMEN

This study evaluated the intraoperative physician assessment (IPA) of bone status at time of total knee arthroplasty. IPA was highly correlated with distal femur and overall bone mineral density. When IPA identifies poor bone status, formal bone health assessment is indicated. PURPOSE: Intuitively, intraoperative physician assessment (IPA) would be an excellent measure of bone status gained through haptic feedback during bone preparation. However, no studies have evaluated the orthopedic surgeon's ability to do so. This study's purpose, in patients undergoing total knee arthroplasty (TKA), was to relate IPA with (1) the lowest bone mineral density (BMD) T-score at routine clinical sites; and (2) with distal femur BMD. METHODS: Seventy patients undergoing TKA by 3 surgeons received pre-operative DXA. Intraoperatively, bone quality was assessed on a 5-point scale (1 excellent to 5 poor) based on tactile feedback to preparation. Demographic data, DXA results, and IPA score between surgeons were compared by factorial ANOVA. Lowest T-score and distal femur BMD were associated with IPA using Spearman's correlation. RESULTS: The mean (SD) age and BMI were 65.8 (7.6) years and 31.4 (5.1) kg/m2, respectively. Patient demographic data, BMD, and IPA (mean [SD] = 2.74 [1.2]) did not differ between surgeons. IPA correlated with the lowest T-score (R = 0.511) and distal femur BMD (R = 0.603-0.661). Based on the lowest T-score, no osteoporotic patients had an IPA above average, and none with normal BMD was classified as having poor bone. CONCLUSIONS: IPA is highly correlated with local (distal femur) and overall BMD. This study supports the International Society for Clinical Densitometry position that surgeon concern regarding bone quality should lead to bone health assessment. As IPA is comparable between surgeons, it is logical this can be widely applied by experienced orthopedic surgeons. Future studies evaluating IPA at other anatomic sites are indicated.


Asunto(s)
Densidad Ósea , Médicos , Humanos , Absorciometría de Fotón/métodos , Fémur/diagnóstico por imagen , Fémur/cirugía , Persona de Mediana Edad , Anciano
4.
J Clin Densitom ; 25(4): 448-455, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36114106

RESUMEN

BACKGROUND: As arthroplasty leads to bone loss, we hypothesized that humeral bone mineral density (BMD) is lower after total shoulder arthroplasty (TSA) in the operative versus non-operative arm. However, there is no clinical approach to measure humeral BMD with dual-energy x-ray absorptiometry (DXA). The purposes of this pilot study were to develop DXA methodology to measure humerus BMD, propose humerus regions of interest (ROIs), compare TSA BMD to the non-operative arm, correlate humeral BMD with standard sites, and evaluate measurement reproducibility. METHODOLOGY: Thirty-eight adults 1-5 years post-TSA had standard clinical DXA scans plus full humerus scans using the atypical femur fracture feature; precision was assessed in a subset (n = 32). Six custom ROIs were used to measure BMD throughout the humerus. Radius and humeral BMD were compared between arms by paired t-test and correlated ipsilaterally using Pearson's Correlation. Custom ROI BMD precision was assessed using the International Society for Clinical Densitometry (ISCD) advanced precision calculator. RESULTS: Study included 38 subjects (24M/14F), with mean (SD) age and time post-surgery of 69.6 (7.7) years and 2.5 (1.3) years respectively. BMD was lower (p < 0.01) at all custom humerus sites (3.8% to 8.2%) on the surgical side but not different at radius sites. Humeral BMD correlated positively with ipsilateral ultra-distal and 1/3 radius (r = 0.54 to 0.86; p < 0.05). Custom BMD precision (%CV) ranged from 6.0-16.0%. CONCLUSIONS: Humerus BMD can be measured using DXA and is lower in the TSA arm. Radius BMD correlated with humeral BMD but was not lower in the surgical arm. BMD precision was worse than usual clinical sites; use of software optimized for the femur is a notable limitation and likely contributes to suboptimal precision. Further study to assess the clinical utility of humeral BMD is needed. Automation and optimization of these measurements should improve precision.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Densidad Ósea , Adulto , Humanos , Absorciometría de Fotón/métodos , Brazo , Húmero/diagnóstico por imagen , Proyectos Piloto , Reproducibilidad de los Resultados
5.
J Clin Densitom ; 25(3): 319-327, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35210129

RESUMEN

Distal femur BMD declines ∼20% following total knee arthroplasty (TKA) potentially leading to adverse outcomes. BMD knowledge before and following TKA might allow interventions to optimize outcomes. We hypothesized that distal femur and proximal tibial BMD could be reproducibly measured with existing DXA technology. Elective TKA candidates were enrolled and standard clinical DXA plus bilateral PA and lateral knee scans acquired. Manual regions of interest (ROIs) were placed at distal femur and proximal tibia sites based on required TKA machining and periprosthetic fracture location. Intra- and inter-rater BMD reliability was assessed by intra-class correlation (ICC). Custom and standard proximal femur BMD were correlated by linear regression and paired t test evaluated BMD differences between planned surgical and contralateral side. One hundred subjects (68F/32M), mean (SD) age and BMI of 67.2 (7.7) yr and 30.8 (4.8) kg/m2 were enrolled. Lowest clinical BMD T-score was < -1.0 in 65% and ≤ -2.5 in 16%; 34 had prior fracture. BMD reproducibility at all custom ROIs was excellent; ICC > 0.96. Mean BMD at custom ROIs ranged from 0.903 to 1.346 g/cm2 in the PA projection and 0.891 to 1.429 g/cm2 in the lateral. Lower BMD values were observed at the proximal tibia, while the higher measurements were at the femur condyle. Custom knee ROI BMD was highly correlated (p < 0.0001) with total and femur neck with better correlation at ROIs adjacent to the joint (R2 = 0.62-0.67, 0.49-0.55 respectively). In those without prior TKA (n = 76), mean BMD was lower (2.8%-6.6%; p < 0.05) in the planned surgical leg at all custom ROIs except the PA tibial regions. Individual variability was present with 82% having a custom ROI with lower BMD (up to 53%) in the planned operative leg. Distal femur and proximal tibial BMD can be measured using custom ROIs with good reproducibility. Suboptimal bone status is common in TKA candidates and distal femur/proximal tibia BMD is often lower on the planned operative side. Routine distal femur/proximal tibial BMD measurement might assist pre-operative interventions, surgical decision-making, subsequent care and outcomes. Studies to evaluate these possibilities are indicated.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Tibia , Absorciometría de Fotón , Densidad Ósea , Fémur/diagnóstico por imagen , Fémur/cirugía , Humanos , Reproducibilidad de los Resultados , Tibia/diagnóstico por imagen , Tibia/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA