Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Soft Matter ; 12(46): 9355-9363, 2016 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-27830218

RESUMEN

We study the formation of yield-stress fluid foams in millifluidic flow-focusing and T-junction devices. First, we provide a phase diagram for the unsteady operating regimes of bubble production when the gas pressure and the yield-stress fluid flow rate are imposed. Three regimes are identified: a co-flow of gas and yield-stress fluid, a transient production of bubble and a flow of yield-stress fluid only. Taking wall slip into account, we provide a model for the pressure at the onset of bubble formation. Then, we detail and compare two simple methods to ensure steady bubble production: regulation of the gas pressure or flow-rate. These techniques, which are easy to implement, thus open pathways for controlled production of dry yield-stress fluid foams as shown at the end of this article.

2.
Phys Rev Lett ; 114(20): 204501, 2015 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-26047231

RESUMEN

We study the production of bubbles inside yield stress fluids (YSFs) in axisymmetric T-junction and flow-focusing devices. Taking advantage of yield stress over capillary stress, we exhibit a robust break-up mechanism reminiscent of the geometrical operating regime in 2D flow-focusing devices for Newtonian fluids. We report that when the gas is pressure driven, the dynamics is unsteady due to hydrodynamic feedback and YSF deposition on the walls of the channels. However, the present study also identifies pathways for potential steady-state production of bubbly YSFs at large scale.

3.
Anal Chem ; 87(11): 5620-5, 2015 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-25940094

RESUMEN

We present for the first time a proof-of-concept system implementing the stochastic injection techniques within a silicon-based microgas chromatograph (µGC) which differs from standard laboratory chromatographs by its small size, shorter column and corresponding elution times, and potential low cost when batch manufactured in high volumes. We demonstrate that stochastic injection techniques can enable the continuous detection of pollutants or toxic gases, with high temporal resolution (5 s) and order-of-magnitude improvements in limit of detection compared to a standard single-injection technique, thus greatly improving performance of air quality monitoring devices. Since micro-GC systems have the potential to 1 day become ubiquitous in indoor environments, such stochastic injection techniques could enable faster detection of toxic compounds at lower concentrations in both industrial and residential settings.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Cromatografía de Gases , Monitoreo del Ambiente/métodos , Monitoreo del Ambiente/instrumentación , Factores de Tiempo
4.
Lab Chip ; 14(13): 2259-65, 2014 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-24816268

RESUMEN

In this article, microparticles are manipulated inside an optofluidic Fabry-Pérot cylindrical cavity embedding a fluidic capillary tube, taking advantage of field enhancement and multiple reflections within the optically-resonant cavity. This enables trapping of suspended particles with single-side injection of light and with low optical power. A Hermite-Gaussian standing wave is developed inside the cavity, forming trapping spots at the locations of the electromagnetic field maxima with a strong intensity gradient. The particles get arranged in a pattern related to the mechanism affecting them: either optical trapping or optical binding. This is proven to eventually translate into either an axial one dimensional (1D) particle array or a cluster of particles. Numerical simulations are performed to model the field distributions inside the cavity allowing a behavioral understanding of the phenomena involved in each case.

5.
Phys Rev Lett ; 113(26): 265502, 2014 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-25615352

RESUMEN

We present a combination of experimental data and modeling that explains some of the important characteristics of black silicon (BSi) developed in cryogenic reactive ion etching (RIE) processes, including static properties (dependence of resulting topography on process parameters) and dynamic aspects (evolution of topography with process time). We generate a phase diagram predicting the RIE parameter combinations giving rise to different BSi geometries and show that the topographic details of BSi explain the metamaterial characteristics that are responsible for its low reflectivity. In particular, the unique combination of needle and hole features of various heights and depths, which is captured by our model and confirmed by focused ion beam nanotomography, creates a uniquely smooth transition in refractive index. The model also correctly describes dynamical characteristics, such as the dependence of aspect ratio on process time, and the prediction of new etching fronts appearing at topographical saddle points during the incipient stages of BSi development--a phenomenon reported here for the first time.

6.
Lab Chip ; 13(14): 2682-5, 2013 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-23649405

RESUMEN

We present a novel optical technique for simultaneously measuring the absorbance and the refractive index of a thin film using an infrared optofluidic probe. Experiments were carried on two different liquids and the results agree with the bibliographical data. The ultimate goal is to achieve a multi-functional micro-optical device for analytical applications.

7.
Lab Chip ; 13(5): 826-33, 2013 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-23295776

RESUMEN

In this paper, light coupling into droplet optical resonators by means of a free-space Gaussian beam (GB) is investigated through numerical simulations and experiments. This method is introduced as an alternative to previously reported methods based on coupling through tapered fibers or prisms. Though applicable to solid-state optical resonators, this method is investigated here in the context of optofluidics for preserving the integrity of the droplet shape and for facilitating the steps of alignment and light coupling. The glycerol droplet under study is supported by a super-hydrophobic surface, which consists of Teflon-coated nanostructured silicon, to provide the advantage of keeping the droplet at a specific location, while maintaining a nearly spherical shape. The effectiveness of this method is tested with millimeter-sized droplets through measurements of their spectral responses. Quality factors Q in excess of 6 × 10(3) have been recorded. An analytical model for the external quality factor associated with this coupling technique has been derived, and the effect of the coupling parameters is demonstrated, allowing discussion about the scaling effects.

8.
Nanoscale Res Lett ; 6(1): 288, 2011 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-21711805

RESUMEN

: We present a fabrication process of low-cost superlattices and simulations related with the heat dissipation on them. The influence of the interfacial roughness on the thermal conductivity of semiconductor/semiconductor superlattices was studied by equilibrium and non-equilibrium molecular dynamics and on the Kapitza resistance of superlattice's interfaces by equilibrium molecular dynamics. The non-equilibrium method was the tool used for the prediction of the Kapitza resistance for a binary semiconductor/metal system. Physical explanations are provided for rationalizing the simulation results. PACS: 68.65.Cd, 66.70.Df, 81.16.-c, 65.80.-g, 31.12.xv.

9.
Lab Chip ; 11(2): 215-23, 2011 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-21072440

RESUMEN

We describe a thermal microflowrate sensor for measuring liquid flow velocity in microfluidic channels, which is capable of providing a highly accurate response independent of the thermal and physical properties of the working liquid. The sensor consists of a rectangular channel containing a heater and several temperature detectors microfabricated on suspended silicon bridges. Heat pulses created by the heater are advected downstream by the flow and are detected using the temperature detector bridges. By injecting a pseudo-stochastic thermal signal at the heater and performing a cross correlation between the detected and the injected signals, we can measure the single-pulse response of the system with excellent signal-to-noise ratio and hence deduce the thermal signal time-of-flight from heater to detector. Combining results from several detector bridges allows us to eliminate diffusion effects, and thus calculate the flow velocity with excellent accuracy and linearity over more than two orders of magnitude. The experimental results obtained with several test fluids closely agree with data from finite element analysis. We developed a phenomenological model which supports and explains the observed sensor response. Several fully functional sensor prototypes were built and characterized, proving the feasibility and providing a critical component to microfluidic lab-on-chip applications where accurate flow measurements are of importance.


Asunto(s)
Hidrodinámica , Técnicas Analíticas Microfluídicas/instrumentación , Simulación por Computador , Diseño de Equipo , Técnicas Analíticas Microfluídicas/métodos , Modelos Químicos , Temperatura
10.
Phys Rev E Stat Nonlin Soft Matter Phys ; 71(6 Pt 1): 061803, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16089757

RESUMEN

We study the coarsening dynamics of two-dimensional hexagonal patterns formed by single microdomain layers of block copolymers, using numerical simulations. Our study is focused on the temporal evolution of the orientational correlation length, the interactions between topological defects, and the mechanisms of coarsening. We find no free disclinations in the system; rather, they are located on large-angle grain boundaries, commonly where such boundaries bifurcate. The correlation lengths determined from the scattering function, from the density of dislocations, and from the density of disclinations exhibit similar behavior and grow with time according to a power law. The orientational correlation length also grows following a power law, but with a higher exponent than the other correlation lengths. The orientational correlation length grows via annihilation of dislocations, through preferential annihilation of small-angle grain boundaries due to poor screening of the strain field around dislocations located on small-angle grain boundaries. Consequently, the patterns are characterized by large-angle grain boundaries. The most commonly observed mechanism of coarsening is the collapse of smaller grains residing on the boundary of two larger grains delimited by large-angle grain boundaries. Simulations agree remarkably well with experimental results recently obtained.

11.
Scanning ; 25(1): 25-33, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12627895

RESUMEN

We describe a method for using polynomial mapping to correct scanning probe microscope images for distortion due to piezoelectric creep. Because such distortion varies from image to image, this method can be used when the actual locations of some features within an image are known absolutely, or in a series of images in which the actual locations of some features are known not to vary. While the general case of polynomial mapping of degree N requires the determination of 2(N+ 1)2 matrix elements by regression, we find that by understanding the mechanism by which piezoelectric creep distorts scanning probe microscope images, we can fix most of these coefficients at 0 or 1 a priori, leaving only 2(N+ 1) coefficients to be determined by regression. We describe our implementation of this strategy using the Interactive Data Language (IDL) programming language, and demonstrate our technique on a series of atomic force microscopy (AFM) images of diblock copolymer microdomains. Using our simplified scheme, we are able to reduce the effects of distortion in an AFM image from 5% of the scan width to a single pixel, using only five reference points.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...