Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
1.
Eur Radiol ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38900281

RESUMEN

OBJECTIVES: Artificial intelligence (AI) tools are becoming more available in modern healthcare, particularly in radiology, although less attention has been paid to applications for children and young people. In the development of these, it is critical their views are heard. MATERIALS AND METHODS: A national, online survey was publicised to UK schools, universities and charity partners encouraging any child or young adult to participate. The survey was "live" for one year (June 2022 to 2023). Questions about views of AI in general, and in specific circumstances (e.g. bone fractures) were asked. RESULTS: One hundred and seventy-one eligible responses were received, with a mean age of 19 years (6-23 years) with representation across all 4 UK nations. Most respondents agreed or strongly agreed they wanted to know the accuracy of an AI tool that was being used (122/171, 71.3%), that accuracy was more important than speed (113/171, 66.1%), and that AI should be used with human oversight (110/171, 64.3%). Many respondents (73/171, 42.7%) felt AI would be more accurate at finding problems on bone X-rays than humans, with almost all respondents who had sustained a missed fracture strongly agreeing with that sentiment (12/14, 85.7%). CONCLUSIONS: Children and young people in our survey had positive views regarding AI, and felt it should be integrated into modern healthcare, but expressed a preference for a "medical professional in the loop" and accuracy of findings over speed. Key themes regarding information on AI performance and governance were raised and should be considered prior to future AI implementation for paediatric healthcare. CLINICAL RELEVANCE STATEMENT: Artificial intelligence (AI) integration into clinical practice must consider all stakeholders, especially paediatric patients who have largely been ignored. Children and young people favour AI involvement with human oversight, seek assurances for safety, accuracy, and clear accountability in case of failures. KEY POINTS: Paediatric patient's needs and voices are often overlooked in AI tool design and deployment. Children and young people approved of AI, if paired with human oversight and reliability. Children and young people are stakeholders for developing and deploying AI tools in paediatrics.

2.
Insights Imaging ; 15(1): 129, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38816589

RESUMEN

Postmortem CT (PMCT) has become increasingly accepted alongside skeletal surveys as a critical part of investigation in childhood deaths, either as part of a suite of non-invasive investigations through parental choice, or comprehensive evaluation in a forensic setting. Whilst CT image acquisition and protocols have been published and are relatively standardised, CT imaging reporting remains highly variable, largely dependent upon reporter experience and expertise. The main "risk" in PMCT is the over-interpretation of normal physiological changes on imaging as pathological, potentially leading to misdiagnosis or overdiagnosis of the disease. In this article, we present a pragmatic standardised reporting framework, developed over a decade of PMCT reporting in children in our institution, with examples of positive and negative findings, so that it may aid in the interpretation of PMCT images with those less experienced in paediatric findings and postmortem imaging. CRITICAL RELEVANCE STATEMENT: Standardised reporting using a common framework with a sound understanding of normal postmortem changes that occur in children are crucial in avoiding common reporting errors at postmortem CT. KEY POINTS: Familiarity with postmortem imaging is required for useful image reporting, and reporting standards vary. Understanding normal postmortem change from significant abnormalities requires training and experience. Following a template may remind reporters what to include and help improve performance.

4.
Eur Radiol ; 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38459348

RESUMEN

OBJECTIVES: Corner metaphyseal lesions (CMLs) are specific for child abuse but challenging to detect on radiographs. The accuracy of CT for CML detection is unknown. Our aim was to compare diagnostic accuracy for CML detection on post-mortem skeletal surveys (PMSS, plain radiography) versus post-mortem CT (PMCT). METHODS: A 10-year retrospective review was performed at a children's hospital for patients having PMSS, PMCT and histopathological correlation (reference standard) for suspected CMLs. Twenty-four radiologists independently reported the presence or absence of CMLs in all cases in a blinded randomised cross-over design across two rounds. Logistic regression models were used to compare accuracy between modalities. RESULTS: Twenty CMLs were reviewed for each of the 10 subjects (200 metaphyses in all). Among them, 20 CMLs were confirmed by bone histopathology. Sensitivity for these CMLs was significantly higher for PMSS (69.6%, 95% CI 61.7 to 76.7) than PMCT (60.5%, 95% CI 51.9 to 68.6). Using PMSS for detection of CMLs would yield one extra correct diagnosis for every 11.1 (95% CI 6.6 to 37.0) fractured bones. In contrast, specificity was higher on PMCT (92.7%, 95% CI 90.3 to 94.5) than PMSS (90.5%, 95% CI 87.6 to 92.8) with an absolute difference of 2.2% (95% CI 1.0 to 3.4, p < 0.001). More fractures were reported collectively by readers on PMSS (785) than on PMCT (640). CONCLUSION: PMSS remains preferable to PMCT for CML evaluation. Any investigation of suspected abuse or unexplained deaths should include radiographs of the limbs to exclude CMLs. CLINICAL RELEVANCE STATEMENT: In order to avoid missing evidence that could indicate child abuse as a contributory cause for death in children, radiographs of the limbs should be performed to exclude CMLs, even if a PMCT is being acquired. KEY POINTS: • Corner metaphyseal lesions (CMLs) are indicative for abuse, but challenging to detect. Skeletal surveys (i.e. radiographs) are standard practice; however, accuracy of CT is unknown. • Sensitivity for CML detection on radiographs is significantly higher than CT. • Investigation of unexplained paediatric deaths should include radiographs to exclude CMLs even if CT is also being performed.

5.
Prenat Diagn ; 44(5): 572-579, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38367004

RESUMEN

OBJECTIVE: To compare the diagnostic performance of postmortem ultrasound (PMUS), 9.4 T magnetic resonance imaging (MRI) and microfocus computed tomography (micro-CT) for the examination of early gestation fetuses. METHOD: Eight unselected fetuses (10-15 weeks gestational age) underwent at least 2 of the 3 listed imaging examinations. Six fetuses underwent 9.4 T MRI, four underwent micro-CT and six underwent PMUS. All operators were blinded to clinical history. All imaging was reported according to a prespecified template assessing 36 anatomical structures, later grouped into five regions: brain, thorax, heart, abdomen and genito-urinary. RESULTS: More anatomical structures were seen on 9.4 T MRI and micro-CT than with PMUS, with a combined frequency of identified structures of 91.9% and 69.7% versus 54.5% and 59.6 (p < 0.001; p < 0.05) respectively according to comparison groups. In comparison with 9.4 T MRI, more structures were seen on micro-CT (90.2% vs. 83.3%, p < 0.05). Anatomical structures were described as abnormal on PMUS in 2.7%, 9.4 T MRI in 6.1% and micro-CT 7.7% of all structures observed. However, the accuracy test could not be calculated because conventional autopsy was performed on 6 fetuses of that only one structure was abnormal. CONCLUSION: Micro-CT appears to offer the greatest potential as an imaging adjunct or non-invasive alternative for conventional autopsies in early gestation fetuses.


Asunto(s)
Autopsia , Feto , Edad Gestacional , Imagen por Resonancia Magnética , Humanos , Femenino , Embarazo , Imagen por Resonancia Magnética/métodos , Autopsia/métodos , Feto/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Ultrasonografía Prenatal/métodos , Adulto , Imágenes Post Mortem
6.
BJR Open ; 6(1): tzad005, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38352182

RESUMEN

Missed fractures are a costly healthcare issue, not only negatively impacting patient lives, leading to potential long-term disability and time off work, but also responsible for high medicolegal disbursements that could otherwise be used to improve other healthcare services. When fractures are overlooked in children, they are particularly concerning as opportunities for safeguarding may be missed. Assistance from artificial intelligence (AI) in interpreting medical images may offer a possible solution for improving patient care, and several commercial AI tools are now available for radiology workflow implementation. However, information regarding their development, evidence for performance and validation as well as the intended target population is not always clear, but vital when evaluating a potential AI solution for implementation. In this article, we review the range of available products utilizing AI for fracture detection (in both adults and children) and summarize the evidence, or lack thereof, behind their performance. This will allow others to make better informed decisions when deciding which product to procure for their specific clinical requirements.

7.
BJR Open ; 6(1): tzad006, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38352185

RESUMEN

Objectives: The aim of this study was to evaluate the length of time required to achieve full iodination using potassium tri-iodide as a contrast agent, prior to human fetal postmortem microfocus computed tomography (micro-CT) imaging. Methods: Prospective assessment of optimal contrast iodination was conducted across 157 human fetuses (postmortem weight range 2-298 g; gestational age range 12-37 weeks), following micro-CT imaging. Simple linear regression was conducted to analyse which fetal demographic factors could produce the most accurate estimate for optimal iodination time. Results: Postmortem body weight (r2 = 0.6435) was better correlated with iodination time than gestational age (r2 = 0.1384), producing a line of best fit, y = [0.0304 × body weight (g)] - 2.2103. This can be simplified for clinical use whereby immersion time (days) = [0.03 × body weight (g)] - 2.2. Using this formula, for example, a 100-g fetus would take 5.2 days to reach optimal contrast enhancement. Conclusions: The simplified equation can now be used to provide estimation times for fetal contrast preparation time prior to micro-CT imaging and can be used to manage service throughput and parental expectation for return of their fetus. Advances in knowledge: A simple equation from empirical data can now be used to estimate preparation time for human fetal postmortem micro-CT imaging.

8.
HSS J ; 19(4): 418-427, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37937091

RESUMEN

Background: Abnormal prenatal hip joint loading can lead to compromised hip joint function. Early intervention is crucial for favorable outcomes. Purpose: This study investigates the impact of treatment timing (initiation and duration) on cartilage growth and ossification in the proximal femur of infants with developmental dysplasia of the hip, a condition affecting newborns. Methods: We used a mechanobiological model to simulate proximal femur growth during treatment durations of 3 months, 6 months, and a late-start treatment. Results: The findings indicate that the timing of treatment initiation is crucial, while a longer treatment duration does not contribute to improved morphological development of the hip joint. Conclusions: Mechanobiological models of growth can be used to develop treatments and therapies that correct loading conditions. Growing bone is particularly sensitive to loading conditions, and altered loading during growth can affect bone shape and functionality.

9.
Pediatr Radiol ; 53(12): 2323-2344, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37674051

RESUMEN

Children living with achondroplasia are at an increased risk of developing neurological complications, which may be associated with acute and life-altering events. To remediate this risk, the timely acquisition of effective neuroimaging that can help to guide clinical management is essential. We propose imaging protocols and follow-up strategies for evaluating the neuroanatomy of these children and to effectively identify potential neurological complications, including compression at the cervicomedullary junction secondary to foramen magnum stenosis, spinal deformity and spinal canal stenosis. When compiling these recommendations, emphasis has been placed on reducing scan times and avoiding unnecessary radiation exposure. Standardized imaging protocols are important to ensure that clinically useful neuroimaging is performed in children living with achondroplasia and to ensure reproducibility in future clinical trials. The members of the European Society of Pediatric Radiology (ESPR) Neuroradiology Taskforce and European Society of Neuroradiology pediatric subcommittee, together with clinicians and surgeons with specific expertise in achondroplasia, wrote this opinion paper. The research committee of the ESPR also endorsed the final draft. The rationale for these recommendations is based on currently available literature, supplemented by best practice opinion from radiologists and clinicians with subject-specific expertise.


Asunto(s)
Acondroplasia , Radiología , Niño , Humanos , Lactante , Foramen Magno/cirugía , Reproducibilidad de los Resultados , Constricción Patológica , Acondroplasia/diagnóstico por imagen
10.
JCI Insight ; 8(14)2023 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-37440461

RESUMEN

The adrenal glands synthesize and release essential steroid hormones such as cortisol and aldosterone, but many aspects of human adrenal gland development are not well understood. Here, we combined single-cell and bulk RNA sequencing, spatial transcriptomics, IHC, and micro-focus computed tomography to investigate key aspects of adrenal development in the first 20 weeks of gestation. We demonstrate rapid adrenal growth and vascularization, with more cell division in the outer definitive zone (DZ). Steroidogenic pathways favored androgen synthesis in the central fetal zone, but DZ capacity to synthesize cortisol and aldosterone developed with time. Core transcriptional regulators were identified, with localized expression of HOPX (also known as Hop homeobox/homeobox-only protein) in the DZ. Potential ligand-receptor interactions between mesenchyme and adrenal cortex were seen (e.g., RSPO3/LGR4). Growth-promoting imprinted genes were enriched in the developing cortex (e.g., IGF2, PEG3). These findings reveal aspects of human adrenal development and have clinical implications for understanding primary adrenal insufficiency and related postnatal adrenal disorders, such as adrenal tumor development, steroid disorders, and neonatal stress.


Asunto(s)
Corteza Suprarrenal , Aldosterona , Recién Nacido , Humanos , Aldosterona/metabolismo , Hidrocortisona/metabolismo , Glándulas Suprarrenales/metabolismo , Esteroides , Proteínas de Homeodominio/metabolismo
11.
Biomaterials ; 301: 122203, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37515903

RESUMEN

Lung infections are one of the leading causes of death worldwide, and this situation has been exacerbated by the emergence of COVID-19. Pre-clinical modelling of viral infections has relied on cell cultures that lack 3D structure and the context of lung extracellular matrices. Here, we propose a bioreactor-based, whole-organ lung model of viral infection. The bioreactor takes advantage of an automated system to achieve efficient decellularization of a whole rat lung, and recellularization of the scaffold using primary human bronchial cells. Automatization allowed for the dynamic culture of airway epithelial cells in a breathing-mimicking setup that led to an even distribution of lung epithelial cells throughout the distal regions. In the sealed bioreactor system, we demonstrate proof-of-concept for viral infection within the epithelialized lung by infecting primary human airway epithelial cells and subsequently injecting neutrophils. Moreover, to assess the possibility of drug screening in this model, we demonstrate the efficacy of the broad-spectrum antiviral remdesivir. This whole-organ scale lung infection model represents a step towards modelling viral infection of human cells in a 3D context, providing a powerful tool to investigate the mechanisms of the early stages of pathogenic infections and the development of effective treatment strategies for respiratory diseases.


Asunto(s)
COVID-19 , Neumonía , Virosis , Ratas , Humanos , Animales , Pulmón , Células Epiteliales , Andamios del Tejido/química
12.
Prenat Diagn ; 43(7): 937-949, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37127547

RESUMEN

Autopsy investigations provide valuable information regarding fetal death that can assist in the parental bereavement process, and influence future pregnancies, but conventional autopsy is often declined by parents because of its invasive approach. This has led to the development of less-invasive autopsy investigations based on imaging technology to provide a more accessible and acceptable choice for parents when investigating their loss. Whilst the development and use of more conventional clinical imaging techniques (radiographs, CT, MRI, US) are well described in the literature for fetuses over 20 weeks of gestational age, these investigations have limited diagnostic accuracy in imaging smaller fetuses. Techniques such as ultra-high-field MRI (>3T) and micro-focus computed tomography have been shown to have higher diagnostic accuracy whilst still being acceptable to parents. By further developing and increasing the availability of these more innovative imaging techniques, parents will be provided with a greater choice of acceptable options to investigate their loss, which may in turn increase their uptake. We provide a narrative review focussing on the development of high-resolution, non-invasive imaging techniques to evaluate early gestational pregnancy loss.


Asunto(s)
Aborto Espontáneo , Autopsia , Muerte Fetal , Humanos , Femenino , Embarazo , Adulto , Imagen por Resonancia Magnética , Aborto Espontáneo/diagnóstico por imagen , Aborto Espontáneo/etiología , Edad Gestacional , Muerte Fetal/etiología
13.
Pediatr Radiol ; 53(6): 1135-1143, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36729184

RESUMEN

BACKGROUND: Postmortem imaging is used more widely as the number of conventional autopsies has decreased over the last several decades. It is widely accepted in Europe, Asia and Oceania, but there has been a delay in acceptance in North America. Education, scanning protocols, resourcing and clinical incentives are needed to support this emerging field. OBJECTIVE: To determine the use of postmortem imaging and define perceived barriers to its implementation with the goal of expanding postmortem imaging in the United States and Canada. MATERIALS AND METHODS: We sent an online survey to active members of the Society for Pediatric Radiology (SPR) addressing the use of postmortem imaging, indications, readers, practical aspects, anticipated barriers and potential solutions to more widespread use. RESULTS: More than 50% of the 50 institutions that returned surveys used postmortem computed tomography; 24% used postmortem magnetic resonance imaging. Most postmortem imaging cases were read by radiologists. Fewer than 50% had formal correlation with autopsy results or an established relationship with the local medical examiner. Seven institutions reported reimbursement for postmortem imaging. Major barriers to postmortem imaging included lack of funding and lack of interest among clinicians. Funding and education were seen as important issues requiring attention. CONCLUSION: While most responding institutions provide pediatric postmortem imaging, the modalities, protocols, reporting procedures and clinical correlation vary widely. A lack of funding and few opportunities for education are limiting factors. Attention to these issues along with active support from the SPR are seen as potential solutions to recognize the value and promote widespread acceptance of postmortem imaging.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Humanos , Niño , Autopsia/métodos , América del Norte , Imagen por Resonancia Magnética/métodos , Encuestas y Cuestionarios
14.
Br J Radiol ; 96(1147): 20211078, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35451852

RESUMEN

Post-mortem imaging for the investigation of perinatal deaths is an acceptable tool amongst parents and religious groups, enabling a less invasive autopsy examination. Nevertheless, availability is scarce nationwide, and there is some debate amongst radiologists regarding the best practice and optimal protocols for performing such studies. Much of the published literature to date focusses on single centre experiences or interesting case reports. Diagnostic accuracy studies are available for a variety of individual imaging modalities (e.g. post-mortem CT, MRI, ultrasound and micro-CT), however, assimilating this information is important when attempting to start a local service.In this article, we present a comprehensive review summarising the latest research, recently published international guidelines, and describe which imaging modalities are best suited for specific indications. When the antenatal clinical findings are not supported by the post-mortem imaging, we also suggest how and when an invasive autopsy may be considered. In general, a collaborative working relationship within a multidisciplinary team (consisting of radiologists, radiographers, the local pathology department, mortuary staff, foetal medicine specialists, obstetricians and bereavement midwives) is vital for a successful service.


Asunto(s)
Imagen por Resonancia Magnética , Muerte Perinatal , Humanos , Embarazo , Femenino , Autopsia/métodos , Ultrasonografía , Radiólogos
15.
Pediatr Radiol ; 53(4): 632-639, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36169668

RESUMEN

Over the last few years, fetal postmortem microfocus computed tomography (micro-CT) imaging has increased in popularity for both diagnostic and research purposes. Micro-CT imaging could be a substitute for autopsy, particularly in very early gestation fetuses for whom autopsy can be technically challenging and is often unaccepted by parents. This article provides an overview of the latest research in fetal postmortem micro-CT imaging with a focus on diagnostic accuracy, endovascular staining approaches, placental studies and the reversibility of staining. It also discusses new methods that could prove helpful for micro-CT of larger fetuses. While more research is needed, contrast-enhanced micro-CT has the potential to become a suitable alternative to fetal autopsy. Further research using this novel imaging tool could yield wider applications, such as its practise in imaging rare museum specimens.


Asunto(s)
Feto , Placenta , Femenino , Embarazo , Humanos , Autopsia/métodos , Edad Gestacional , Placenta/diagnóstico por imagen , Feto/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Imagen por Resonancia Magnética/métodos
16.
Pediatr Radiol ; 53(2): 273-281, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36097227

RESUMEN

BACKGROUND: Perinatal and childhood postmortem imaging has been accepted as a noninvasive alternative or adjunct to autopsy. However, the variation in funding models from institution to institution is a major factor prohibiting uniform provision of this service. OBJECTIVE: To describe current funding models employed in European and non-European institutions offering paediatric postmortem imaging services and to discuss the perceived barriers to future postmortem imaging service provision. MATERIALS AND METHODS: A web-based 16-question survey was distributed to members of the European Society of Paediatric Radiology (ESPR) and ESPR postmortem imaging task force over a 6-month period (March-August 2021). Survey questions related to the radiologic and autopsy services being offered and how each was funded within the respondent's institute. RESULTS: Eighteen individual responses were received (13/18, 72.2% from Europe). Only one-third of the institutions (6/18, 33.3%) have fully funded postmortem imaging services, with the remainder receiving partial (6/18, 33.3%) or no funding (5/18, 27.8%). Funding (full or partial) was more commonly available for forensic work (13/18, 72%), particularly where this was nationally provided. Where funding was not provided, the imaging and reporting costs were absorbed by the institute. CONCLUSION: Increased access is required for the expansion of postmortem imaging into routine clinical use. This can only be achieved with formal funding on a national level, potentially through health care commissioning and acknowledgement by health care policy makers and pathology services of the value the service provides following the death of a fetus or child. Funding should include the costs involved in training, equipment, reporting and image acquisition.


Asunto(s)
Diagnóstico por Imagen , Radiología , Embarazo , Femenino , Niño , Humanos , Autopsia/métodos , Diagnóstico por Imagen/métodos , Medicina Legal , Encuestas y Cuestionarios
17.
iScience ; 25(10): 105174, 2022 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-36217545

RESUMEN

Decellularization of esophagi from several species for tissue engineering is well described, but successful implantation in animal models of esophageal replacement has been challenging. The purpose of this study was to assess feasibility and applicability of esophageal replacement using decellularized porcine esophageal scaffolds in a new pre-clinical model. Following surgical replacement in rabbits with a vascularizing muscle flap, we observed successful anastomoses of decellularized scaffolds, cues of early neovascularization, and prevention of luminal collapse by the use of biodegradable stents. However, despite the success of the surgical procedure, the long-term survival was limited by the fragility of the animal model. Our results indicate that transplantation of a decellularized porcine scaffold is possible and vascular flaps may be useful to provide a vascular supply, but long-term outcomes require further pre-clinical testing in a different large animal model.

18.
Evol Med Public Health ; 10(1): 316-324, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35903461

RESUMEN

Background and objectives: Several studies have linked longer legs with favorable adult metabolic health outcomes and greater offspring birth weight. A recent Mendelian randomization study suggested a causal link between height and cardiometabolic risk; however, the underlying reasons remain poorly understood. Methodology: Using a cross-sectional design, we tested in a convenience sample of 70 healthy young women whether birth weight and tibia length as markers of early-life conditions associated more strongly with metabolically beneficial traits like organ size and skeletal muscle mass (SMM) than a statistically derived height-residual variable indexing later, more canalized growth. Results: Consistent with the 'developmental origins of health and disease' hypothesis, we found relatively strong associations of tibia length-but not birth weight-with adult organ size, brain size, SMM and resting energy expenditure measured by magnetic resonance imaging (MRI), dual-energy X-ray absorptiometry and indirect calorimetry, respectively. Conclusions and implications: Building on prior work, these results suggest that leg length is a sensitive marker of traits directly impacting metabolic and reproductive health. Alongside findings in the same sample relating tibia length and height-residual to MRI-measured pelvic dimensions, we suggest there may exist a degree of coordination in the development of long bone, lean mass and pelvic traits, possibly centered on early, pre-pubertal growth periods. Such phenotypic coordination has important implications for fitness, serving to benefit both adult health and the health of offspring in subsequent generations.

19.
Pediatr Radiol ; 52(13): 2538-2548, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35666285

RESUMEN

BACKGROUND: More than half of paediatric radiology research presented at annual conference meetings between 2010-2012 remains unpublished. It is unclear if there are any improvements in this statistic despite some initiatives to improve awareness of the importance of evidence-based medicine. OBJECTIVES: To determine the abstract to publication rates (APRs) originating from recent paediatric radiology meetings, trends in research topics and factors associated with publication success. MATERIALS AND METHODS: All PubMed cited articles originating from oral presentations at European Society of Paediatric Radiology, Society for Paediatric Radiology or International Paediatric Radiology conferences between 2013-2016 were evaluated, and compared to those from previously published data from the same conferences dated 2010-2012. Publication rates, study design and topic as well as characteristics of the research group (e.g., author affiliations and number) were evaluated and compared between published and unpublished groups. RESULTS: The APR increased to 433/937 (46%) for abstracts presented between 2013-2016, compared to 300/715 (42%) in 2010-2012 (P=0.094). The largest proportion of publications comes from academic and tertiary centres (324/433 [75%]). International collaboration increased to 49/433 (11%) from 18/300 (6%) in 2010-2012 (P=0.018). A greater proportion of work was published within 12 months of conference: 41% in 2013-2016, compared to 29% in 2010-2012 (P=0.02). Paediatric Radiology remained the most popular destination journal, publishing 167/433 (39%) articles. CONCLUSION: There was a slight increase over time in the proportion of abstracts that resulted in publication, yet more than half of abstracts still do not reach publication status. Further work should identify how radiologists (particularly those outside tertiary and academic centres) can be supported to share their research.


Asunto(s)
Indización y Redacción de Resúmenes , Radiología , Niño , Humanos , Sociedades Médicas , Radiografía , Proyectos de Investigación
20.
Insights Imaging ; 13(1): 94, 2022 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-35657439

RESUMEN

BACKGROUND: Majority of research and commercial efforts have focussed on use of artificial intelligence (AI) for fracture detection in adults, despite the greater long-term clinical and medicolegal implications of missed fractures in children. The objective of this study was to assess the available literature regarding diagnostic performance of AI tools for paediatric fracture assessment on imaging, and where available, how this compares with the performance of human readers. MATERIALS AND METHODS: MEDLINE, Embase and Cochrane Library databases were queried for studies published between 1 January 2011 and 2021 using terms related to 'fracture', 'artificial intelligence', 'imaging' and 'children'. Risk of bias was assessed using a modified QUADAS-2 tool. Descriptive statistics for diagnostic accuracies were collated. RESULTS: Nine eligible articles from 362 publications were included, with most (8/9) evaluating fracture detection on radiographs, with the elbow being the most common body part. Nearly all articles used data derived from a single institution, and used deep learning methodology with only a few (2/9) performing external validation. Accuracy rates generated by AI ranged from 88.8 to 97.9%. In two of the three articles where AI performance was compared to human readers, sensitivity rates for AI were marginally higher, but this was not statistically significant. CONCLUSIONS: Wide heterogeneity in the literature with limited information on algorithm performance on external datasets makes it difficult to understand how such tools may generalise to a wider paediatric population. Further research using a multicentric dataset with real-world evaluation would help to better understand the impact of these tools.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...