Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Anaesthesiol ; 30(11): 658-63, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23812621

RESUMEN

BACKGROUND: Implantation of cardiovascular implantable electronic devices (CIEDs) has greatly increased during the last decade and anaesthetic management of these patients remains an open question. OBJECTIVE: This study describes anaesthetic management and risk factors associated with complications occurring during these procedures. DESIGN: A single-centre prospective observational study. SETTING: Grenoble University Hospital, France, from May 2010 to October 2010. PATIENTS: All patients admitted to the cardiac electrophysiology laboratory were included. INTERVENTION: None. MAIN OUTCOME MEASURES: Clinical data, anaesthetic and medical characteristics as well as complications (respiratory or cardiovascular) and treatment were recorded by the anaesthetic nurse at the end of each procedure. RESULTS: Two hundred and sixty-nine patients were included, 229 (85%) with an American Society of Anaesthesiologists (ASA) status of 3 or 4, 103 (38%) with a New York Heart Association (NYHA) functional class of 3 or 4 and 136 (51%) with a left ventricular ejection fraction of less than 40%. Two hundred and forty-seven (92%) of the patients underwent deep sedation and 12 (8%) general anaesthesia. Seventy-eight (29%) patients had at least one complication, among whom 21 (27%) had at least one considered as severe. Fifty (19%) of the patients had a respiratory complication and 46 (17%) a cardiovascular complication; the latter was more frequently severe (41 vs. 12%; P=0.001). Lead extraction [odds ratio (OR) 13.7, 95% confidence interval (CI) 3.5 to 53.3; P<0.001], NYHA status of 4 (OR 11.8, 95% CI 1.8 to 74.8; P<0.001), implantable cardioverter-defibrillator (ICD) testing by T-wave shock (OR 3.9, 95% CI 1.53 to 10.2; P=0.005) and length of procedure (OR 1.01, 95% CI 1.004 to 1.031; P=0.013) were identified as independent risk factors for cardiovascular complications. CONCLUSION: Patients requiring cardiovascular implantable electronic device (CIED) implantation were fragile with a high complication rate and a high rate of severe complications even with anaesthesiological support. These complications, as well as the need for deep sedation or general anaesthesia, clearly justify the involvement of a qualified anaesthesiologist.


Asunto(s)
Anestesiología/métodos , Electrofisiología Cardíaca/métodos , Desfibriladores Implantables/efectos adversos , Anciano , Anestesia/métodos , Estudios de Cohortes , Muerte Súbita Cardíaca/etiología , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA