Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Leg Med (Tokyo) ; 47: 101787, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32992157

RESUMEN

This study was aimed at investigating and comparing exposure dose of workers and the surrounding workers. In addition, worker's exposure was also measure about lens and finger. Four intraoral portable X-ray units were evaluated. The stray radiations were measured using Pitman 37D and ionization chamber (Pitman). MyDosemini (ALOKA) was used for measurement of the finger exposure dose. Without the shield became high in anterior 0.5 m. Comparing the air dose for the four models used in this study showed a high tendency for the two NOMAD models. And using the shields, the images could be taken 4.6 times of the baseline at a maximum and 3.6 times on average. The finger radiation exposure dose was low with both of the NOMAD models, with no significant difference found. By setting the baseline value without a shield, finger radiation exposure when using a shield was lower than the detection limit for the D3000, and was reduced by approximately 94-96% for other three models. All models can photograph around 100 bodies, so it is considered that it is not necessary to switch out the operator considering the operation limit. But even if it does not reach the operation limit, the stochastic effects of radiation exposure can be increased as well as the deterministic effects of the operation limit. The operator and the surrounding workers seek to protect themselves. It is important to perform exposure management that takes into account the stochastic effects to the operator and the surrounding workers.


Asunto(s)
Exposición Profesional/efectos adversos , Exposición Profesional/análisis , Dosis de Radiación , Radiografía/efectos adversos , Radiografía/instrumentación , Dedos , Humanos , Cristalino , Exposición Profesional/prevención & control , Fantasmas de Imagen , Equipos de Seguridad , Radiografía Dental
2.
Leg Med (Tokyo) ; 37: 18-24, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30597413

RESUMEN

Age is often estimated using teeth because numerous external and internal changes appear due to aging. The purpose of this study was to investigate an age estimation method based on the volume ratio of the internal structure of the crown. 61 maxillary first premolars and 50 maxillary second premolars from subjects aged 20-79 years old were used. Micro CT, which can be used to analyze teeth in a non-destructive manner with high sensitivity, was employed in the present study. In consideration of individual differences among subjects, the volume ratio was calculated for the following four items: The pulp chamber was calculated separately based on the presence of enamel.In order to estimate age, regression analysis was conducted with the actual age as the dependent variable and each volume ratio as the independent variable. As a result, the highest correlation was found with PVR (E-) for each measurement item. Therefore, the regression equation using the volume change of the maxillary premolar crown as an index was as follows: Age = -12.43 × 4: PVR (E-) + 69.85. Age = -12.94 × 5: PVR (E-) + 72.54.


Asunto(s)
Determinación de la Edad por los Dientes/métodos , Envejecimiento/patología , Diente Premolar/diagnóstico por imagen , Odontología Forense/métodos , Maxilar , Corona del Diente/diagnóstico por imagen , Microtomografía por Rayos X , Adulto , Anciano , Diente Premolar/patología , Esmalte Dental/diagnóstico por imagen , Esmalte Dental/patología , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Corona del Diente/patología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA