1.
J Healthc Eng ; 2018: 4038034, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29666670

RESUMEN

Background: Heart rate variability (HRV) provides information about the activity of the autonomic nervous system. Because of the small amount of data collected, the importance of HRV has not yet been proven in clinical practice. To collect population-level data, smartphone applications leveraging photoplethysmography (PPG) and some medical knowledge could provide the means for it. Objective: To assess the capabilities of our smartphone application, we compared PPG (pulse rate variability (PRV)) with ECG (HRV). To have a baseline, we also compared the differences among ECG channels. Method: We took fifty parallel measurements using iPhone 6 at a 240 Hz sampling frequency and Cardiax PC-ECG devices. The correspondence between the PRV and HRV indices was investigated using correlation, linear regression, and Bland-Altman analysis. Results: High PPG accuracy: the deviation of PPG-ECG is comparable to that of ECG channels. Mean deviation between PPG-ECG and two ECG channels: RR: 0.01 ms-0.06 ms, SDNN: 0.78 ms-0.46 ms, RMSSD: 1.79 ms-1.21 ms, and pNN50: 2.43%-1.63%. Conclusions: Our iPhone application yielded good results on PPG-based PRV indices compared to ECG-based HRV indices and to differences among ECG channels. We plan to extend our results on the PPG-ECG correspondence with a deeper analysis of the different ECG channels.


Asunto(s)
Frecuencia Cardíaca/fisiología , Pulso Arterial/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Teléfono Inteligente , Adulto , Electrocardiografía/instrumentación , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Fotopletismografía/instrumentación , Fotopletismografía/métodos , Pulso Arterial/métodos
2.
Stud Health Technol Inform ; 169: 671-5, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21893832

RESUMEN

Prevention and rehabilitation efficiency can greatly benefit from the application of intelligent, 24 hour tele-diagnostics and tele-care information systems. Tele-monitoring also supports a new level of medical supervision over the patient's lifestyle. In this paper we briefly present the architecture and development phase results of the Alpha remote monitoring system. The novelty of the system is the unified and flexible processing of various signals retrieved from modern, unobtrusive devices in an efficient signal abstraction framework. The signals include PIR motion sensors that record patient movement in the home, physiological signals and also patient responses in various tests performed on the GUI of the central home unit. We have developed and tested the prototype system with promising results.


Asunto(s)
Monitoreo Ambulatorio/instrumentación , Cognición , Comunicación , Redes de Comunicación de Computadores , Sistemas de Computación , Computadores , Diseño de Equipo , Servicios de Atención de Salud a Domicilio , Humanos , Sistemas de Registros Médicos Computarizados , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Movimiento (Física) , Enfermedades del Sistema Nervioso/diagnóstico , Enfermedades del Sistema Nervioso/terapia , Consulta Remota , Telemedicina/instrumentación , Telemedicina/métodos , Interfaz Usuario-Computador