Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Pharmacol ; 63(6): 520-7, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24477045

RESUMEN

P2Y(12) receptor antagonism inhibits platelet aggregation by preventing adenosine diphosphate (ADP)-mediated amplification of activation pathways downstream of primary agonists, such as thrombin and collagen. However, the role of ADP signaling in maintaining aggregate stability and the effects of P2Y(12) antagonists on preestablished aggregates in vitro and arterial thrombus in vivo are not well understood. This study evaluated the impact of P2Y(12) signaling on platelet aggregate stability and early thrombotic occlusion using a reversible P2Y(12) antagonist, ticagrelor. There were 2 study objectives: (1) to determine if there was a time-dependent factor on the capacity of a P2Y(12) antagonist to affect human platelet aggregate stability in vitro using light transmission aggregometry and (2) to evaluate the extent of arterial thrombus reversal in a preclinical model upon administration of ticagrelor in vivo. Platelet aggregates were exposed to ticagrelor after ADP or collagen activation, monitored for stability by aggregometry, and visualized by microscopy. Freshly formed ADP- and collagen-induced platelet aggregates were more rapidly dispersed by a P2Y(12) antagonist than drug carrier control at clinically relevant concentrations (P < 0.05). However, stable aggregates were not noticeably affected. A murine arterial thrombosis model was used to evaluate thrombus stability in an in vivo mouse model. Thrombotic occlusion was induced by FeCl(3), followed by a bolus intravenous administration of ticagrelor or vehicle control. Doppler blood flow was monitored before injury and 30 minutes after bolus administration. Arteries were retrieved for inspection for residual thrombus. Early arterial thrombotic occlusion in vivo was partially reversed by ticagrelor administration. Blood flow through the injured artery increased, and thrombus size within the artery decreased (P < 0.05, n = 3). In conclusion, P2Y(12) antagonism disrupts the stability of newly formed platelet aggregates, promoting disaggregation, and reverses thrombotic vascular occlusion. Thus, in addition to activating platelets, signaling via P2Y(12) seems to be required for stabilizing platelet thrombi.


Asunto(s)
Agregación Plaquetaria/fisiología , Antagonistas del Receptor Purinérgico P2Y/farmacología , Receptores Purinérgicos P2Y12/metabolismo , Transducción de Señal/fisiología , Adenosina/análogos & derivados , Adenosina/farmacología , Adenosina/uso terapéutico , Animales , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Agregación Plaquetaria/efectos de los fármacos , Antagonistas del Receptor Purinérgico P2Y/uso terapéutico , Transducción de Señal/efectos de los fármacos , Trombosis/tratamiento farmacológico , Trombosis/metabolismo , Ticagrelor , Factores de Tiempo
2.
Biomarkers ; 14(8): 572-86, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19780643

RESUMEN

Ximelagatran was developed for the prevention and treatment of thromboembolic conditions. However, in long-term clinical trials with ximelagatran, the liver injury marker, alanine aminotransferase (ALT) increased in some patients. Analysis of plasma samples from 134 patients was carried out using proteomic and metabolomic platforms, with the aim of finding predictive biomarkers to explain the ALT elevation. Analytes that were changed after ximelagatran treatment included 3-hydroxybutyrate, pyruvic acid, CSF1R, Gc-globulin, L-glutamine, protein S and alanine, etc. Two of these analytes (pyruvic acid and CSF1R) were studied further in human cell cultures in vitro with ximelagatran. A systems biology approach applied in this study proved to be successful in generating new hypotheses for an unknown mechanism of toxicity.


Asunto(s)
Alanina Transaminasa/sangre , Azetidinas/efectos adversos , Bencilaminas/efectos adversos , Biomarcadores/análisis , Enfermedad Hepática Inducida por Sustancias y Drogas/etiología , Adenosina Trifosfato/metabolismo , Proteínas Sanguíneas/metabolismo , Células Cultivadas , Ensayos Clínicos como Asunto , Proteína de Unión al Complemento C4b , Femenino , Hepatocitos/efectos de los fármacos , Hepatocitos/metabolismo , Antígenos de Histocompatibilidad/sangre , Humanos , Macrófagos/fisiología , Masculino , Metabolómica/métodos , Proteína S , Proteómica/métodos , Ácido Pirúvico/metabolismo , Receptor de Factor Estimulante de Colonias de Macrófagos/sangre , Biología de Sistemas , Células Tumorales Cultivadas , Proteína de Unión a Vitamina D/sangre
3.
J Chromatogr B Analyt Technol Biomed Life Sci ; 852(1-2): 317-24, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17296338

RESUMEN

An analytical method was developed for the determination of ximelagatran, an oral direct thrombin inhibitor, its active metabolite melagatran, and the two intermediate metabolites, OH-melagatran and ethyl-melagatran in human plasma. Extraction of plasma was carried out on a mixed mode bonded sorbent material (C8/SO(3)(-)). All four analytes, including their isotope-labelled internal standards, were eluted at high ionic strength with a mixture of 50% methanol and 50% buffer (0.25 M ammonium acetate and 0.05 M formic acid, pH 5.3) with an extraction recovery above 80%. The extracts were demonstrated to be clean in terms of a low concentration of albumin and lysoPC. The sample extraction was fully automated and performed in 96-well plates using a Tecan Genesis pipetting robot. Analysis of the extracts were performed with liquid chromatography followed by positive electrospray ionization mass spectrometry. The low organic content and the low pH of the extracts allowed for, after dilution 1:3 with buffer, direct injection onto the LC-column. The four analytes were separated on a C18 analytical LC-column using gradient elution with the acetonitrile concentration varying from 10 to 30% (v/v) and the ammonium acetate and acetic acid concentration kept constant at 10 and 5 mmol/L, respectively, at a flow rate of 0.75 mL/min. Linearity was achieved over the calibrated range 0.010-4.0 micromol/L with accuracy and relative standard deviation in the range 96.9-101.2% and 6.6-17.1%, respectively at LLOQ, and in the range 94.7-102.6% and 2.7-6.8%, respectively at concentrations above 3 x LLOQ. The method replaces a manual method, and displays the advantages of having a fully automated sample clean-up, no evaporation/reconstitution step, high recovery, and complete LC-separation of all four analytes.


Asunto(s)
Anticoagulantes/sangre , Antitrombinas/metabolismo , Azetidinas/sangre , Bencilaminas/sangre , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Calibración , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA