Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 87: 95-100, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24296069

RESUMEN

During reactor operation (148g)Pm and (148m)Pm are formed in large quantities from thermal neutron capture on the fission product (147)Pm. Subsequent neutron capture reactions, on the (148)Pm ground state and isomer, have cross sections differing by a factor of 5 and so precise knowledge of their decay properties is vitally important. New decay scheme evaluations using the DDEP methodology for (148g)Pm and (148m)Pm are presented. The complete data tables and detailed evaluator comments are available through the DDEP website.

2.
Appl Radiat Isot ; 87: 101-6, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24369893

RESUMEN

This study focuses on two radioisotopes of silver, (108m)Ag and (110m)Ag, characterized by a complex decay scheme. Each isotope has two disintegration modes, the isomeric transition leading to the daughter isotope ((108)Ag and (110)Ag, respectively) with a short half-life. The radioactive solution was obtained by neutron activation on silver powder enriched in (109)Ag. Gamma-spectrometry was carried out using a calibrated high purity germanium detector. The main relative photon emission intensities for both radionuclides were obtained and compared with previously published values.

3.
Appl Radiat Isot ; 87: 342-7, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24360861

RESUMEN

Xenon-127 was standardized by internal gas counting using three proportional counters in a differential arrangement to eliminate edge effects. The detection efficiency of the proportional counters was calculated by considering the cascade of events following the electron capture and associated gamma transitions. Activity per unit volume was measured with 0.7% relative standard uncertainty. Gamma-ray spectrometry was performed and absolute photon emission intensities were derived. This study shows that (127)Xe could be a surrogate for (133)Xe for the calibration of remote radio-xenon monitoring stations.

4.
Appl Radiat Isot ; 70(9): 1894-9, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22406222

RESUMEN

The purposes of this study were to create national activity standards of (64)Cu, to make possible the definition of an international key comparison reference value and to determine the decay data in order to improve the decay scheme. Four laboratories measured the activity of a (64)Cu solution; these results were compared through the International Reference System. Moreover, the laboratories carried out new measurements of the photon emission intensities and of the half-life. A new decay scheme was derived from these new values and the previously published ones.


Asunto(s)
Radioisótopos de Cobre/análisis , Radioisótopos de Cobre/química , Radiometría/normas , Semivida , Internacionalidad , Dosis de Radiación , Estándares de Referencia , Valores de Referencia
5.
Appl Radiat Isot ; 68(7-8): 1571-7; discussion 1577, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20116267

RESUMEN

To study the decay scheme of (126)Sn, two samples of a purified solution were measured by gamma-ray spectrometry and the relative photon emission intensities were determined. The (126)Sb(m) isomeric branching ratio was derived to be 18.6 (6) %. The maximum beta energy of the (126)Sn decay was checked by liquid scintillation. The Kbeta/Kalpha intensity ratio of Sb was determined being 0.226 (11). These new experimental results were used to re-examine the whole decay scheme of (126)Sn and its daughters.

6.
Appl Radiat Isot ; 68(7-8): 1207-10, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20153206

RESUMEN

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.


Asunto(s)
Antimonio/análisis , Antimonio/normas , Cooperación Internacional , Fotones , Valores de Referencia , Reproducibilidad de los Resultados , Conteo por Cintilación , Soluciones , Pesos y Medidas
7.
Appl Radiat Isot ; 68(10): 2026-30, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20171111

RESUMEN

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories, six of which sent results for photon emission intensities both in absolute and in relative terms. From these results and including previous published values, a consistent decay scheme was worked out, proving that problems in activity measurements have not been due to decay scheme data.

8.
Appl Radiat Isot ; 68(1): 122-30, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19734052

RESUMEN

This study describes a new determination of the decay scheme and half-life of (93)Zr. A pure (93)Zr solution was obtained after chemical separation from the dissolution of an irradiated zircaloy sample. The concentration of (93)Zr in the solution was measured by mass spectrometry, with an isotopic dilution technique. The activity of the solution was measured by liquid scintillation counting, using an efficiency tracing method. The measurement of the activity concentration of (93)Nb(m) by X-ray spectrometry, allowed the determination of the (93)Zr decay scheme and the calculation of the (93)Zr detection efficiency. This leads to the calculation of the decay probability of (93)Zr toward (93)Nb(m) of (0.73+/-0.06) and to a half-life of (93)Zr of (1.64+/-0.06)x10(6) years. These values are discussed in comparison with the evaluated values available in the literature.

9.
Appl Radiat Isot ; 66(6-7): 722-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18378152

RESUMEN

Sound quantitative knowledge of internal conversion coefficients (ICCs) is important when establishing decay schemes. ICCs are normally derived from efficiency tables and calculation, but for anomalous transitions and some electric dipole transitions (E1) in particular, theoretical values can differ considerably from the few available measured values. Experimentally measured ICCs and their ratios have been compiled, and these data have been used to propose a method based on the existence of measured ratios to determine the total ICC for such transitions. Comparisons have been made with the existing measured values, and good agreement was observed within the uncertainty limits.

10.
Appl Radiat Isot ; 62(1): 11-5, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15498679

RESUMEN

Half-life measurements have been carried out at LNHB for 88Y using a 4pi gamma-ionisation chamber and for 89Sr using a proportional counter. The determined half-life values and associated standard uncertainties are 106.63 +/- 0.05 d for 88Y and 50.65 +/- 0.05 d for 89Sr, being consistent with relevant values reported in literature. Based on the present results and relevant literature values revised recommended half-life values and associated standard uncertainties are proposed, viz. 106.626 +/- 0.021 d for 88Y and 50.57 +/- 0.03 d for 89Sr.


Asunto(s)
Radiometría/métodos , Radiometría/normas , Estándares de Referencia , Radioisótopos de Estroncio/análisis , Radioisótopos de Estroncio/normas , Radioisótopos de Itrio/análisis , Radioisótopos de Itrio/normas , Francia , Semivida
11.
Appl Radiat Isot ; 60(2-4): 439-45, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-14987682

RESUMEN

Palladium 103 is a radionuclide used in brachytherapy sources for the treatment of prostate cancers and also for other medical applications. It decays through electron capture to excited levels of 103Rh. This paper describes the calculation method used to compute the detection efficiency in the framework of the triple to double coincidence ratio model. The calculation of the energy transferred to the scintillator is made by considering the various atomic events following the electron capture and the electron conversion. The energy deposited in the scintillator after the absorption of X-rays is calculated using the PENELOPE stochastic calculation code. The main contributors to the final uncertainty and their covariance matrix are discussed. As the calculation method cannot be reduced to an explicit function, this paper describes the Monte Carlo method used for the evaluation of uncertainties.


Asunto(s)
Braquiterapia/normas , Calibración/normas , Paladio/análisis , Paladio/normas , Radioisótopos/análisis , Radioisótopos/normas , Conteo por Cintilación/métodos , Conteo por Cintilación/normas , Algoritmos , Partículas beta , Diseño de Equipo , Análisis de Falla de Equipo , Francia , Radiofármacos/análisis , Radiofármacos/normas , Estándares de Referencia , Reproducibilidad de los Resultados , Conteo por Cintilación/instrumentación , Sensibilidad y Especificidad , Soluciones , Espectrometría gamma/instrumentación , Espectrometría gamma/métodos , Espectrometría gamma/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...